Loading…
Loading…
Tender Value
₹105.1 Cr
EMD Value
₹52.5 L
Closing Date
12 Feb 2026, 3:00 pmClosed
Yes (up to 4 members)
Two Packet System
EPC [ Single Stage ]
Yes
19/01/2026 11:00
Lowest to Highest
180 days
Expenditure
Capital (Works)
WORKS
13 conditions · 2 needing a document upload
Please refer EPC Bid Documents
Please refer EPC Bid Documents
15 conditions · 4 needing a document upload
Please refer EPC Bid Documents
Please refer EPC Bid Documents
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Comprehensive Signalling and Telecommunication Works for Provision of Automatic Block Signalling System in Singarayakonda (SKM)- Chinnaganjam (CJM) Section of Vijayawada Division in South Central Railway
B-SG-P-E-08-SKM-CJM-25-26~SCR
B-SG-P-E-08-SKM-CJM-25-26
Open
Works - General
480 Days
Krishna, Andhra Pradesh
₹0
₹52.5 L
12 Feb 2026
1 Jan 2026
29 Jan 2026
19 Jan 2026
13 items across 1 schedule · ₹12,89,655.07 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.1X7.2X1.5=10.8, 1X5.00X1.5=7.50. | Sqm | 73.20 | 262.7 | 19,229.64 |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:3:6 (1 cement :3coarse sand(zone-III): 6 graded stone aggregate 20mm nominal size).1x7.2x9.85x0.15=10.64 | cum | 42.56 | 7,294.7 | 3,10,462.43 |
| 3 | "Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 15.2.1 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) L C 1 2 5 1x7.2x9.5x0.1=6.84, 4.55x0.45x0.15=0.31, 2.13x0.45x0.35=0.33, 1.25x0.40x0.15=0.08, 7.20x0.40x0.35=1.01, 6.80x0.45x0.15=0.46" | cum | 38.96 | 2,434.25 | 94,838.38 |
| 4 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.: 2x7.2x0.18x3.46=8.97,deduct 2x1.2x0.18x2.00=0.86(-) | cum | 32.44 | 2,060.7 | 66,849.11 |
| 5 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer- in-charge. Pre-laminated particle board with decorative lamination on both sides 2x6x1x0.55 = 6.6, 2x1x0.88x0.55 = 0.97, 2x6x1x1 = 12.00 | Sqm | 78.28 | 1,115.4 | 87,313.51 |
| 6 | With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) | Sqm | 4.80 | 1,176.8 | 5,648.64 |
| 7 | Providing and laying vitrified floor tiles in different sizes (thickness to b e specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm LC125 1X7.2X9.85=70.92 | Sqm | 283.68 | 1,553.45 | 4,40,682.7 |
| 8 | " Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour Old work (one or more coats) 2x7.2x3.75 = 54, 2x9.85x3.75 = 73.875" | Sqm | 511.50 | 62.7 | 32,071.05 |
| 9 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. One coat.@LC No.125- 2X2X9.85X3.7=72.89, 2X7.2X3.7=53.28. DED-D- 1X2.00X1.00=2, W- 8X1.5X1.2=14.4 | Sqm | 439.08 | 92 | 40,395.36 |
| 10 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : doors=3no.s,windows=2no.s | Each | 12.00 | 367.2 | 4,406.4 |
| 11 | "Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 15.23.1 For thickness of tiles 10 mm to 25 mm. LCNO.125 1X7.2X0.44=3.17, 1X6.78X0.42=2.85, 2X1.2X0.44=1.06, 1X4.6X0.44=2.02, 1X4.6X0.42=1.93, 1X2.2X0.86=1.89, 1X6.34X1.20=7.61, 1X7.2X0.18=1.29, 1X6.78X0.18=1.22, 2X4.6X0.18=1.65, 2X1.2X0.17=0.41, 1X2.97X7.2=21@ 46&44@ 1X3.57X7.2=25.70, 1X6.80X0.32=2.18, 1X6.34X0.17=1.08, 1X1.65X0.32=0.53, 1X1.20X0.17=0.20, 1X4.1X0.32=1.31, 1X3.7X0.17=0.63" | Sqm | 312.44 | 73.4 | 22,933.1 |
| 12 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling. C.P. brass/stainless steel screws, all complete Powder coated aluminium (minimum thickness of powder coating 50 micron) V - 7x3.3x1.2 = 27.72, T - 1x7.2x1.2 = 8.64, B - 1x6.28x1.2 = 7.54, H - 2x7x1x1.2 = 16.8, H - 1x6x1x1.2 = 7.2 | Kg | 271.60 | 530.9 | 1,44,192.44 |
| 13 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling. C.P. brass/stainless steel screws, all complete For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) Room partician. Door V - 2x1.95x1.2 = 4 . 6 8 , T&B - 2x0.88x1.2 = 2.11, Middle - 1x0.88x1.2 = 1.05, 2x2x1.95x0.02 = 0.15, 2x4x0.88x0.02 = 0.14 | Kg | 32.52 | 634.45 | 20,632.31 |
| Schedule total | ₹12,89,655.07 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
DraftEPC_Agreement_Revision_I_ABS_SKM-CJM_26012026.pdf
ATTACHMENT
Reply_for_Prebid_Queries_of_SKM-CJM_26012026.pdf
ATTACHMENT
1_Main_Signal_Foundation_in_Between_Tracks_RDSO_M_00011_R4_31_01_2025.pdf
ATTACHMENT
2_5772_MAIN_SIGNAL_FOUNDATION_31_01_2025.pdf
ATTACHMENT
3_CABLE_LAYING_300_DRG_15_D2_OF_IRSEM_31_01_2025.pdf
ATTACHMENT
4_CABLE_LAYING_400_DRG_15_D2_OF_IRSEM_31_01_2025.pdf
ATTACHMENT
5_CABLE_LAYING_600_DRG_15_D2_OF_IRSEM_31_01_2025.pdf
ATTACHMENT
6_CABLE_LAYING_DRG_15_D7_OF_IRSEM_31_01_2025.pdf
ATTACHMENT
7_C_CHANNEL_ST_RE_78_2_76_31_01_2025.pdf
ATTACHMENT
8_5774_GLAND_PLATE_FOR_FULL_LOCATION_BOX_31_01_2025.pdf
ATTACHMENT
9_5777A_CLASS_A_LIGHTING_PROTECTION_31_01_2025.pdf
ATTACHMENT
10_RDSO_Drg_GIRDER_BRACKET_ARRANGEMENTS_CBS_0039_R3.pdf
ATTACHMENT
11_RDSO_Drg_clamping_nad_try_arrgmts_CBS_0038_R3_A.pdf
ATTACHMENT
12_5775_EARTHING_ARRANGEMENT_FOR_SIGNALS_AND_LOCATION_BOXES_31_01_2025.pdf
ATTACHMENT
13_EOLB_FOUNDATION_MFT_6099_31_01_2025.pdf
ATTACHMENT
14_5781_FOUNDATION_FOR_LOCATION_BOX_FULLBOX_31_01_2025.pdf
ATTACHMENT
15_ETI_C_0186_SH1.pdf
ATTACHMENT
15_ETI_C_0186_SH_2.pdf
ATTACHMENT
16_5770_HORIZONTAL_BORING_MICRO_TUNNELING_31_01_2025.pdf
ATTACHMENT
17_5778C_RCC_Cable_duct_REF5778A_01_02_2025.pdf
ATTACHMENT
18_5767_RE_PROTECTIVE_SCREEN_31_01_2025.pdf
ATTACHMENT
19_SLIDING_BOOM_TYPE_LC_GATE_31_01_2025_A.pdf
ATTACHMENT
Corrigendum-1_ABS_SKM-CJM_26012026signed.pdf
ATTACHMENT
20_5768A_Track_Road_crossings.pdf
ATTACHMENT
21_Typical_power_supply_LC_gate_Signed_modified_Drg_No22_02_25.pdf
ATTACHMENT
22_LADDER_31_01_2025.pdf
ATTACHMENT
23_PROTECTION_ARRANGEMENT_FOR_CABLES_AT_LESS_DEPTH_31_01_2025.pdf
ATTACHMENT
24_MANUAL_CROSSING_TRACK_CROSSING_DRG_15_D5_OF_IRSEM_31_01_2025.pdf
ATTACHMENT
25_CABLE_TROUGH_DRG_15_D6_OF_IRSEM_31_01_2025.pdf
ATTACHMENT
26_CABLE_LAYING_DRG_15_D8_OF_IRSEM_31_01_2025.pdf
ATTACHMENT
27_Signalling_legend_boards_Drg_Updated_31_01_2025.pdf
ATTACHMENT
28_5766_CABLE_CHAMBER_31_01_2025.pdf
ATTACHMENT
29_Telecom_Circuits_Channelling_Plan_GSU_07_2022.pdf
ATTACHMENT
30_Telecom_Circuits_Connectivity_Diagram_Updated_on_16_09_2025.pdf
ATTACHMENT
31_Scheme_for_Approach_Warning_System_at_Mid_Section_LC_Gate_31012025_B_P_MISC_02_2025.pdf
ATTACHMENT
32_Tie_bar_fenching_MFT.pdf
ATTACHMENT
33_SHED_for_EOLB_LC_operating_panel_at_LC_gates_GSU_08_2022_31_01_2025.pdf
ATTACHMENT
34_INDICATION_PANEL_AT_ABS_HUT_3RD_LINE_Modified_31_01_2025.pdf
ATTACHMENT
35_ABS_VDU_LAYOUT_AT_STATION_3RD_LINE_A.pdf
ATTACHMENT
36_Typical_schematic_of_Input_output_Multiplexer_31_01_2025_B_P_MISC_5_2025.pdf
ATTACHMENT
37_TYPICAL_CABLE_DISTIBUTION_FOR_EXISTING_SIG_ABS_WORK_3RD_LINEB_GSU_MISC_11_2023.pdf
ATTACHMENT
38_5782_RELAY_RACK_ASSEMBLY.pdf
ATTACHMENT
39_Indication_Panel_at_LC_gate_ON_ABS_3RD_LINE.pdf
ATTACHMENT
40_FULL_LOCATION_BOX_MFT_2378_31_01_2025.pdf
ATTACHMENT
41_RCC_CABLE_MARKER_Drg_No_15_D1.pdf
ATTACHMENT
42_Typical_IPS_Scheme_for_triple_line_updated_16_09_25_signed.pdf
ATTACHMENT
43_Typical_VDU_layout_at_UGD_station.pdf
ATTACHMENT
Annexure_1_SYSTEM_CONFIGURATION_FOR_AUTO_SIGNALLING_TRIPLELINE_01_02_2025.pdf
ATTACHMENT
Annexure_2_1_APPROVED_SCHEME_PLAN_FOR_ABS_SKM_TNR_STATIONS.pdf
ATTACHMENT
Annexure_2_2APPROVED_SCHEME_PLAN_FOR_ABS_TNR_SDM_STATIONS.pdf
ATTACHMENT
Annexure_2_3_APPROVED_SCHEME_PLAN_FOR_ABS_SDM_OGL_STATIONS.pdf
ATTACHMENT
Annexure_2_4_APPROVED_SCHEME_PLAN_FOR_ABS_OGL_KRV_STATIONS.pdf
ATTACHMENT
Annexure_2_5_APPROVED_SCHEME_PLAN_FOR_ABS_KRV_ANB_STATIONS.pdf
ATTACHMENT
Annexure_2_6_APPROVED_SCHEME_PLAN_FOR_ABS_ANB_UGD_STATIONS.pdf
ATTACHMENT
Annexure_2_7_APPROVED_SCHEME_PLAN_FOR_ABS_UGD_CJM_STATIONS.pdf
ATTACHMENT
Annexure_4A_ABS_HUT_LAY_OUT_PLAN_REF_C5757_01_02_2025.pdf
ATTACHMENT
Annexure_4B_ABS_HUT_ELECTRICAL_arrangement_for_hut_3rd_line_31_01_2025.pdf
ATTACHMENT
Annexure_4C_ABS_EQUIPMENT_HUT_LAYOUT_STATION_3RD_LINE.pdf
ATTACHMENT
Annexure_4D_Automatic_Block_Signalling_Equipment_Hut_Electrical_Layout_Plan.pdf
ATTACHMENT
Annexure_4E_TYPICAL_GL_BUILDING_AT_LC_GATES.pdf
ATTACHMENT
Annexure_4F_TYPICAL_ELEC_LAYOUT_AT_GL.pdf
ATTACHMENT
Annexure_13_Standard_Operating_Procedure_for_Stores_management.pdf
ATTACHMENT
Annexure_14_Functional_Requirements_of_Networking_of_MSDAC.pdf
ATTACHMENT
Annexure_15_Technical_Specifications_for_illuminating_A__AG_marker.pdf
ATTACHMENT
Annexure_16_Technical_Specifications_of_FXSgateway_24Ports.pdf
ATTACHMENT
Annexure_17_Scheme_plan_for_MSDAC_in_parallel_with_Track_Circuit_at_UGD_station_1.pdf
ATTACHMENT
RequestforProposal_ABS_SKM-CJM_01012026.pdf
ATTACHMENT
Feasibility_Report_ABS_SKM-CJM_01012026.pdf
ATTACHMENT
Corrigendum-1_ABS_SKM-CJM_26012026signed.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .