Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance B 10 KRISHNA IND ESTATE BIDC GORWA VADODARA 390016 | VADODARA | VADODARA | GUJARAT | 390016 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance FAC 560B EAST CHAWLA COLONY BALLABGARH 121004 FARIDABAD HARYANA | BALLABGARH | FARIDABAD | HARYANA | 121004 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹66,000
Closing Date
16 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Bareilly
HQ CWE (AF) Bareilly
Provn of civilian community hall cum recreation centre and guard room at MES complex at AF Stn Bhowali and Construction of SATCOM Earth Station at AF Stn Bhowali
2022_MES_511043_1
30034/JO/13/E3
Limited
Consultancy Services
Item Rate
45 days
Bhowali
As per NIT
2 documents required · 2 mandatory
₹0
Exempted
18 Mar 2022
28 Feb 2022
18 Mar 2022
2 Mar 2022
16 Mar 2022
2 Mar 2022
2 Mar 2022 - 9 Mar 2022
30 days
Amount
Drilling of 150 mm diameter bore hole in all types of soils as per depth indicated below or refusal strata which ever is earlier as per instructions of the Engineer-in-Charge. Refusal defined as and when ‘N’ value is 100 or more for 30 cm or part penetration.
A) Conducting standard penetration test (SPT) in the boreholes at 1.0m intervals in depth or every change of strata which ever is earlier as per IS 2131-1981. a) For Depth up to 10 Mtr (For small Bldg with shallow foundation) B) Collecting disturbed soil sample from the location of conducting the SPT/DCPT C) Collecting undisturbed samples at 1.50m intervals or change of strata which ever occurs earlier. D) Analysis for liquefaction potential for Earthquake as per Zone – IV of IS :1893-2016 (Part-1) E) Recording the Ground Water Table if observed upto exploration depth, as per IS : 6395:1973. F) Conducting all necessary laboratory tests on samples collected for their different engineering properties. Following tests will be carried out.
I) Dry density and moisture content (IS 2720 Part – 2 & 29) II) Atterberg’s limit – (IS 2720 Part – 5 1985) III) Particle size analysis – (IS 2720 Part-4 1985) & IS Classification of the soil. IV) Specific gravity – (IS 2720 Part – 3/sec 2 1980) V) Consolidation test – (IS 2720 Part – 15 1986) and compressed value index. VI) Free sweel and Swell pressure test – (IS 2720 Part – 40 1977, Part – 41 1977) VII) Bulk Density. VIII) Organic matter in soil if any. IX) Triaxial compression test and determination of (C&ø Value) shear parameters as per relevant IS. X) Harmful salt.
1.2 Submission of Four copies of ink signed test reports. The report should include the following: a. Detailed description of field investigation, soil classification and general nature of soil strata, water table, interpretation of test results, grains size distribution curves, compressive index curves, site plan etc, stress-strain modulus (by stress-strain curves from triaxial tests), Foundation analysis & recommendations with supporting calculations regarding foundation system, depth of foundation. b. The SBC of the soil is required to be given as per following table, calculation of bearing capacity will be goverened generally as per IS 8009 (Part-i) 1976, IS 2720 (P-II) 1980, IS 6403-1980, IS 1904-1986 & 1080-1985 and other relevant IS codes and detailed calculations duly showing the various soil parameters / indices shall be given in the soil report :-
Description of foundation Safe bearing capacity of soil in T/M2 for footing size Strip footing 1.2mx 1.2m 1.5mx 1.5m 2m x 2m 2.5m x 2.5m Remarks 1 m 1.5 m 2.0 m 2.5 m
d. Plotting of a compiled sub-surface profile along the depth in both plan directions. e. Estimation of safe side slopes for excavation. f. Suitability of excavated material as back fill. g. To check for liquefaction potential. h. Any other pertinent information relating of foundation design considered necessary. j. Soil investigation report shall include a detailed site plan showing the approx location of each bore duly numbered as per log of the bore holes should be enclosed. Location of foundation of adjacent structures, especially those that might be impact by the proposed construction should be indicated with details in site plan. k. Photographic record of ge-explorations as well as testing shall also form part of the report. l. Every page of the soil investigation report should have the Name of the Job which soil investigation is being carried out. In case of multiple sites of a single job are being investigated name of each site shall be put on each page of report pertaining to the site. m. All pages of the Soil Investigation Report shall be serially numbered, stamped and signed by the Agency carrying out the Soil Investigation Report should be scrutinized by GE & CWE for correctness & endorsed. n. The GE shall intimate the approximate type of construction, utilization and dimensions of proposed building to the consultant, who based on geotechnical investigation, should recommend type of foundation (viz isolated/combined footing, raft, pile etc). o. In case of underground building basement construction, or if requirement of temporary / permanent deep excavation support measures during construction of building are envisaged necessary excavation support measures to be given by the consultant based on geotechnical investigations.
Drilling of 150 mm diameter bore hole in all types of soils as per depth indicated below or refusal strata which ever is earlier as per instructions of the Engineer-in-Charge. Refusal defined as and when ‘N’ value is 100 or more for 30 cm or part penetration.
A) Conducting standard penetration test (SPT) in the boreholes at 1.0m intervals in depth or every change of strata which ever is earlier as per IS 2131-1981. a) For Depth up to 10 Mtr (For small Bldg with shallow foundation) B) Collecting disturbed soil sample from the location of conducting the SPT/DCPT C) Collecting undisturbed samples at 1.50m intervals or change of strata which ever occurs earlier. D) Analysis for liquefaction potential for Earthquake as per Zone – IV of IS :1893-2016 (Part-1) E) Recording the Ground Water Table if observed upto exploration depth, as per IS : 6395:1973.
F) Conducting all necessary laboratory tests on samples collected for their different engineering properties. Following tests will be carried out. I Dry density and moisture content (IS 2720 Part – 2 & 29) II Atterberg’s limit – (IS 2720 Part – 5 1985) III Particle size analysis – (IS 2720 Part-4 1985) & IS Classification of the soil. IV Specific gravity – (IS 2720 Part – 3/sec 2 1980) V Consolidation test – (IS 2720 Part – 15 1986) and compressed value index. VI Free sweel and Swell pressure test – (IS 2720 Part – 40 1977, Part – 41 1977) VII Bulk Density. VIII Organic matter in soil if any. IX Triaxial compression test and determination of (C&ø Value) shear parameters as per relevant IS. X Harmful salt.
1.2 Submission of Four copies of ink signed test reports. The report should include the following: a. Detailed description of field investigation, soil classification and general nature of soil strata, water table, interpretation of test results, grains size distribution curves, compressive index curves, site plan etc, stress-strain modulus (by stress-strain curves from triaxial tests), Foundation analysis & recommendations with supporting calculations regarding foundation system, depth of foundation. b. The SBC of the soil is required to be given as per following table, calculation of bearing capacity will be goverened generally as per IS 8009 (Part-i) 1976, IS 2720 (P-II) 1980, IS 6403-1980, IS 1904-1986 & 1080-1985 and other relevant IS codes and detailed calculations duly showing the various soil parameters / indices shall be given in the soil report :-
Description of foundation Safe bearing capacity of soil in T/M2 for footing size Strip footing 1.2mx 1.2m 1.5mx 1.5m 2m x 2m 2.5m x 2.5m Remarks 1 m 1.5 m 2.0 m 2.5 m
d. Plotting of a compiled sub-surface profile along the depth in both plan directions. e. Estimation of safe side slopes for excavation. f. Suitability of excavated material as back fill. g. To check for liquefaction potential. h. Any other pertinent information relating of foundation design considered necessary. j. Soil investigation report shall include a detailed site plan showing the approx location of each bore duly numbered as per log of the bore holes should be enclosed. Location of foundation of adjacent structures, especially those that might be impact by the proposed construction should be indicated with details in site plan. k. Photographic record of ge-explorations as well as testing shall also form part of the report. l. Every page of the soil investigation report should have the Name of the Job which soil investigation is being carried out. In case of multiple sites of a single job are being investigated name of each site shall be put on each page of report pertaining to the site. m. All pages of the Soil Investigation Report shall be serially numbered, stamped and signed by the Agency carrying out the Soil Investigation Report should be scrutinized by GE & CWE for correctness & endorsed. n. The GE shall intimate the approximate type of construction, utilization and dimensions of proposed building to the consultant, who based on geotechnical investigation, should recommend type of foundation (viz isolated/combined footing, raft, pile etc).
In case of underground building basement construction, or if requirement of temporary / permanent deep excavation support measures during construction of building are envisaged necessary excavation support measures to be given by the consultant based on geotechnical investigations.
GEO DESIGNS AND RESEARCH PVT LTD
stage.html
html • 0.02 MB
finance_571159.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .