| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.9 LAccepted-AOC ROOM NO 262 PART II NEAR SANKER MANDIR GANESH MURTHI NAGAR COLABA MUMBAI 05 | MUMBAI | 1 | Accepted-AOC Being the Lowest Bidder | |
| 2 | 2₹9.4 L+₹46,664.20 (5.23%)Rejected-AOC | 2 | Rejected-AOC Being other than the Lowest Bidder | |
| 3 | 3₹10.5 L+₹1.6 L (18.0%)Rejected-AOC | 3 | Rejected-AOC Being other than the Lowest Bidder | |
| 4 | 4₹10.6 L+₹1.7 L (19.1%)Rejected-AOC | 4 | Rejected-AOC Being other than the Lowest Bidder | |
| 5 | 5₹12.1 L+₹3.2 L (35.7%)Rejected-AOC VILL MANKAR NORTH RAIPUR PO MANKAR DISTT PURBA BARDHAMAN PIN 713144 WB | MANKAR | PURBA BARDHAMAN | WB | 713144 | 5 | Rejected-AOC Being other than the Lowest Bidder |
Tender Value
₹13 L
EMD Value
₹26,000
Closing Date
24 Mar 2025, 6:00 pmClosed
CWE PANAGARH
HQ CWE PANAGARH, MES, PO - PANAGARH, DIST - BURDWAN, WB, PIN - 713420
REPAIR / MAINT OF PUMPS, AIR COMPRESSORS AND OTHER E/M EQUIPMENTS AT PUMP HOUSE AND CLEANING OF UG SUMP, OH TANK AND SERVICE TANK AND REPAIR / REPLACEMENT OF DG SETS, SEWAGE PUMPS AND OTHER ALLIED WORKS STP AT NMS UNDER AGE (I) NABAGRAM
2025_MES_699005_1
8980/E8
Open Tender
Miscellaneous Services
Item Rate
180 days
NABAGRAM
Pls refer Tender Documents
7 documents required · 7 mandatory
₹500
AGE (I) NABAGRAM
₹26,000
Yes
23 May 2025
22 Feb 2025
1 Apr 2025
22 Feb 2025
24 Mar 2025
10 Mar 2025
Amount
Part-I : REPAIR / MAINT OF PUMPS, AIR COMPRESSORS AND OTHER E/M EQUIPMENTS AT PUMP HOUSE AND CLEANING OF UG SUMP, OH TANK AND SERVICE TANK AT NMS UNDER AGE (I) NABAGRAM
Repairing of sluice valve 150/100 mm dia incl replacement of GI Spindle, CI Gate Mechanical sealing complete all as specified and directed.
Replacement existing unserviceable foundation MS bolt with nuts and washers of various sizes with provision of new one complete all as specified and directed.
S&F rubber packing sheet sluice valve joint 6 mm thick complete all as specified and directed.
Replacement of old unserviceable cast iron hand wheel with provision of new one for sluice valve 80/100/150 mm complete all as specified and directed.
Cleaning of RCC under ground sump of capacity 60000 Ltr by removing sludge, mud or any other foreign material from the bottom and internal surface of the tank by wire brushing, cleaning with fresh water bailing out complete water with pump sets, washing internal surface with sufficient quantity of water and bleaching powder (0.10 Kg of bleaching powder will be mixed in 1 ltr of water) finally applying two coats of lime washing on entire internal surface, writing the date of cleaning and capacity of the tank with white synthetic enamel paint on black background with synthetic enamel paint complete all as specified and directed.
Cleaning of over head water tank of capacity 100000 Ltr at 12 mtr height by removing sludge, mud or any other foreign material from the bottom and internal surface of the tank by wire brushing, cleaning with fresh water bailing out complete water with pump sets, washing internal surface with sufficient quantity of water and bleaching powder (0.10 Kg of bleaching powder will be mixed in 1 ltr of water) finally applying two coats of lime washing on entire internal surface, writing the date of cleaning and capacity of the tank with white synthetic enamel paint on black background with synthetic enamel paint complete all as specified and directed.
M&L two coats of synthetic enamel paint after preparation of surface of external side of iron removal plant of capacity 8000 GPH & all as specified and directed.
Supply only bleaching powder of grade confirming to IS-1065-1989 (2nd Revision) minimum markable chlorine 33.5% by mass packed in HDPE bag of 25 Kg capacity ISI marked complete all as specified and directed. Make: E-in-C's approved make/ Eastern Command approved make. Note: (Applicable for all items of this BOQ) (a) The contractor shall produce manufacturers "Certificate of Compliance" indicating date of manufacturer in original alongwith every consignment of supply. (b) Test certificate from Govt approved Test Laboratory shall accompany with every consignment of supply to ensure that the materials supplied are in with conformity with relevant IS. (c) Independent test shall be carried out by Engr-in-charge before incorporation in work.
Disconnecting all cable/wiring from Chemical dosing pump & transporting the same to workshop & repair & servicing of chemical dosing pump by completly removing of unsericeable parts of following & S&F of new one of following spare parts & repair/ servicing testing complete all as specified and directed: (a) Oil ring - 2 Nos (b) Copper winding - 1 HP motor - 01 Nos. (c) Copper winding - 0.5 HP motor - 01 Nos. (d) Bearing - 04 Nos. [Note : Spare parts and other related item are included in quoted rate. Make of Dosing Pump : King & Make of motor : ABB]
Disconnecting all cable/wiring from air compressor after that Repairing/serviceing of air compressor complete, removing of unserviceable spare parts & replacing the same with new one of following spare parts, change air filters, alignment of pully, change V belt of motors, clean the cooling system, lubricate all moving part like bearing, piston and replace piston ring if required, remove compressor motor, transport to workshop for rewinding and after winding fixed with compressor and testing complete all as specified and directed. (a) Bearing : 4 Nos (b) Piston Ring - 06 Nos (c) Winding of Motor - 01 Nos (d) 'V' belt - 02 Nos (e) Air filter - 01 Nos [Note :Spare parts and of air filter, 'V' belt, lubricant, piston ring, winding wire & other related item are included in quoted rate.] Make of Compressor : Crompton Greaves with 200 litre capacity air tank & 5 HP motor
Supply only Potash Alum (non ferric Alum) IS :258 (2000) of 50 Kg packet to purify the raw water at the pump house complete all as specified and directed.
M&L Construction of brick massonry valve pit chamber of inner dimension 100x100x100 cms suitable for sluice valves upto 100mm size, with PCC (1:4:8) type D-2 for foundation, brick work in cm (1:6) rendering (1:4), 15mm plastering, coping in PCC (1:2:4) type B-1, incl necessary earth work, including MS sheet cover of thickness 2 mm on 50x50x6.0 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement including demolished old valve pit and including earth work, excavation removing the debris from the site or all as specified and directed.
M&L Construction of brick massonry valve pit chamber of inner dimension 50x50x50 cms suitable for sluice valves upto 100mm size, with PCC (1:4:8) type D-2 for foundation, brick work in cm (1:6) rendering (1:4), 15mm plastering, coping in PCC (1:2:4) type B-1, incl necessary earth work, including MS sheet cover of thickness 02 mm on 50x50x6.0 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement including demolished old valve pit including excavation removing etc complete from the site or all as specified and directed.
S&F brass ball valve with steel handle, high pressure, with polythene float and flynut complete,screwed for iron pipe ISI Marked, as per IS: 778 of size 20 mm bore including taking out unsv gate valves complete all as specified and directed.
All As per Srl Item No 1.16 above but of size 25 mm bore complete all as specified and directed.
S&F Aviation obstruction light red colour, non metal material, 25W, lux level-110 Lum/W integral led aviation layout comprising of aluminium with poly carbonate enclosure LED type including mounting arrangement complete all as specified and directed .
Cleaning of PVC/RCC water tank upto 500Ltr capacity by mud or any other foreign material from the bottom and clean internal surface of the tank with hard rough cloth after that cleaning with bleaching powder mixed water (0.10 Kg of bleaching powder will be mixed in 1 ltr of water) , writing the date of cleaning with synthetic enamel paint complete all as specified and directed.
All As per Srl Item No 1.20 above but of size 1000Ltr capacity tank complete all as specified and directed.
Supply only Sodium Hypochlorite of purity : 12.0%, packed in 40 Kgs plastic drums in powder form for water treatment chemical each all as specified and directed. [NOTE :- (i) Approval of chemical (Sodium Hypochlorite) shall be given after verifaction of test certificates of chemical of various manufactures and other factures like chemical and safety and health hazard aspects of usage of chlorination (ii) the branch / make of the chlorination of chemical must be stated in production and certified by govt laboratory. (iii) Materials shall be incorporated after independent testing by Engr-in-charge.]
Supply, fixing, jointing & testing Cast Iron Sluice Valve size of 100 mm bore ISI Marked, flanged ends drilled pressure rating PN-1.6, PD Short body, confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top including taking out unsv sluice valve complete all as specified and directed. [Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.]
All As per Srl Item No1.23 above but of size 150 mm bore complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks capasity of 500Ltr (cylindrical vertical with closed top) with virgin polymer granular, food grade polymer with FDA approved, phthalate free polymer granular & additives, UV stabilized lid, minimum 3 layered (outer-aesthetic looks, Middle -UV protection, Inner - to see water level), antibacterial, antimicrobial hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed
All As per Srl Item No 1.25 above but of size 1000Ltr complete all as specified and directed.
Part-II : REPAIR/ REPLACEMENT OF DG SETS, SEWAGE PUMPS AND OTHER ALLIED WORKS STP AT NMS UNDER AGE (I) NABAGRAM
Maint and servicing of DG sets consisting normal repairs, including replacement of defective/burn out parts by new spares such as oil/diesel filters, gaskets,V belts, Engine oil all as specified,coolent & media, rubber hoses, wornout, clamps, nut and bolts and cleaning of alternator with vaccum cleaner and including greassing of bearing etc and made serviceable complete for upto 30 KVA capacity, complete all as specified and directed. Make : Kirloskar/ Koel Green/CG. [Note : (i) Checking engine oil level and topping up as and when required . (ii) Oil shall be measures and paid separately (iii) Checking and adjusting the belt for tension and replacement of belt. (iv) Belt shall be measured and paid seperately (v)Checking of air filter element (vi) Checking of exhaust system for leakage (vii) Draining of sediment from fuel filter and fuel tank (viii) Cleaning of air cleaner element (ix) Checking engine alternator coupling, mounting bolts and alignment
Item No 2.01 Contd…. (x) Tighting all nuts, bolts, in altenator terminal block (xi) Checking of alternator carbon brush and connections in alternator (xii) Checking and tighting of all connection in DC control wiring. (xiii) Trouble shooting of any type of fault in DG set through out the contract. Clearing of fault and testing complete. [Note : (a) Supply only the spares required incorporation of repairs of item No 1 (a) to (e) above and respective items for DG upto 30 KVA as mentioned under item No. 2.04 to 2.23 herein after shall be measured and paid seperately under respective items of schedule as "Supply only". (b) Work shall be executed through OEM/ OEM authorized agency/ reputed company who have sufficient technical experience in the field as approved by AGE (I) Nabagram.]
All same as per Item No. 2.01 above but for capacity 30KVA to 63KVA, complete all as specified and directed. Make : Kirloskar/ Koel Green/CG. [Note : (a) Supply only the spares required incorporation of repairs of item No 1 (a) to (e) above and respective items for DG 30 KVA to 63KVA as mentioned under item No. 2.04 to 2.23 herein after shall be measured and paid seperately under respective items of schedule as "Supply only". (b) Work shall be executed through OEM/ OEM authorized agency/ reputed company who have sufficient technical experience in the field as approved by AGE (I) Nabagram.]
Supply only diesel filter (Primary and baby) element as per existing make and size with O Ring for upto 30KVA capacity DG set, complete all as specified and directed.
All as per Item No. 2.04 above but for 30KVA to 63KVA capacity DG set, complete all as specified and directed.
Supply only engine oil filter element as per existing make and size with O Ring for upto 30KVA capacity DG set, complete all as specified and directed.
All as per Item No. 2.06 above but for 30KVA to 63KVA capacity DG set, complete all as specified and directed.
Supply only air filter element for upto 30KVA capacity DG set, complete all as specified and directed.
All as per Item No. 2.08 above but for 30KVA to 63KVA capacity DG set, complete all as specified and directed.
Supply only fan belt of alternator/radiator for upto 30KVA capacity DG set, complete all as specified and directed.
All as per Item No. 2.10 above but for 30KVA to 63KVA capacity DG set, complete all as specified and directed.
Supply only rubber hose pipe set suitable upto 01 mtr long for water line circuit complete with clamps, for capacity of DG set upto 30 KVA against item No. 2.01 herein before complete all as specified and directed.
All as per Item No. 2.12 above but for 30KVA to 63KVA capacity DG set, complete all as specified and directed.
S&F in repairs new PVC insulated multistranded, copper conductor 70 sqmm multistranded of 1.25 mtr long each duly fixed with brass clamps, copper lugs suitable for DG sets installed at different locations from battery to starter as battery leads, complete all as specified and directed.
Supply only engine oil, multi grade 15W40 for topping up OR pouring in engine of DG sets against item No. 2.02 herein before in which labour portion of fixing the item is included draining out the existing old unserviceable oil, complete all as specified and directed.
Supply only Petroleum jelly in 01 kg sealed plastic containers of 1kg each and applying in the battery terminals of the DG sets, complete all as specified & directed.
Supply only distilled water for topping up in the batteries all as directed against item No. 2.01 or 2.02 herein before in which labour portion of fixing the item is included, complete all as specified and directed.
M&L for in replacement Rubber Coupling with nut bolt & washer in between Alternator and Engine & upto 63 KVA DG set, complete all as specified and directed.
Labour for strip opening carefully of the existing FIP and injectors and transporting to an service centre for servicing / calibrating including petty repairs to make the FIP functional for capacity of DG set upto 30KVA including necessary spares required for smooth functioning of FIP, complete all as specified and directed.
All as per Item No. 2.19 above but for 30KVA to 63KVA capacity DG set, complete all as specified and directed.
M&L earthing complete with galvanized steel plate electrode of size 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs deep below normal ground level, connected to galvanised earth, lead wire 4.0 mm dia by means of bolts, nuts, and washers of galvanised iron or steel all as shown in earth plate No 3 in MES schedule Part I of 2009 connected to machinery/ equipment for Time Panel etc. as required 32 x 6 mm dia galvanized iron with 40 mm GI light Grade pipe for protection including necessary excavation and earth work, concrete pit & chamber in PCC 1:2:4 type B1 (using 20 mm graded stone aggregrate) & pit cover 75mm thick in RCC 1:2:4 type B1 (using 20 mm graded stone aggregrate) duly reinforced with 6mm dia bar @ 150 c/c both ways including with lifting handle and Earth lead and 20 mm bore GI watering pipe medium grade, funnels, charcoal, salt etc testing resistance on completion, complete all as specified and directed.
Repairing to the broken door of the DG set of any capacity with necessary works such as welding hinges fitting, locking and painting to existing match where required complete all as specified and directed.
Supply only coolent media for radiator assembly of specified grade, complete all as specified and directed.
S&F in replacement change over (Off Load/On Load type) switch 4 pole, 415 V, 100 Amp complete all as specified and directed.
S&F in replacement change over (Off Load/On Load type) switch 4 pole, 415 V, 200 Amp complete all as specified and directed.
S&F in replacement start/stoping solenoid of the DG set of capacity up to 63 KVA complete all as specified and directed.
S&F in replacement emergency switch of DG set of any capacity complete all as specified and directed.
S&F in replacement start key/ignition switch/emergency switch of DG set of any capacity complete all as specified and directed.
S&F in repair diesel pipe of any DG set upto 1meter complete all as specified and directed.
Labour charges for draining out the Water from engine of radiator , dis-mantling the leaking radiator assembly from the engine body of 63 KVA DG set, transporting to workshop, cutting the bottom chambers, repairing the damaged pipes, brazing the leaking portions ,descaling / clearing all the blocked pipes including repairing the fins, brazing the bottom chambers, testing the radiator for leakages, transporting the same to the site and re-fixing and testing complete all as specified and directed.
Labour charges for cleaning for fuel tank both internally and externally by removing all the dust/sediments etc. and M&L for painting of tank, writing of tank capacity, date of cleaning and next due date for tank to be cleaned for capacity of DG set upto 30KVA, including necessary repair works if leackage of oil noticed, complete all as specified and directed.
All as per Item No. 2.31 above but for 63KVA capacity DG set, complete all as specified and directed.
Dismantling the existing unserviceable battery, supply and fix new lead acid battery 12 Volts 100 AH ( heavy duty with electrolyte indicator float including initial charging of the battery connecting up) complete all as specified and directed.
Labour only for attending breakdowns of DG sets through skilled technician from reputed service centre of DG sets with necessary tool kits, checking Engine and alternator for defects, carryout necessary repairs works to rectify the defects without major overhauling/opening of Engine or Alternators, replace of external spare to repair/rectify the defects and testing DG set for its smooth functioning on full load complete all as specified and directed. [Note : (i) Necessary spares required to rectify the defects shall be measured and paid separately under relavant items. (ii) The complaint shall be attended and rectifed within 24 hrs form time of reporting by Engr-in-Charge or his auth representative. (iii) Any Major defects shall be reported on Priority to Engr-in-charge to avoid undue delay in fuctioning of installation."
S&F in replacement digital Ammeter/volt meter complete all as specified and directed.
Taking out burnt out winding and S&F and rewinding the Self startor coil, of any type with copper enameled wire including other minor repairs replacement of solenoid field coils and testing and refixing the Self startor after repair with alignment rotor with shaft and coupling, Copper enameled wire, lumex paper, glass wire varnish and cotton tape etc with all required accessories for 320/250 /125 KVA DG sets including necessary electrical and earthing connections complete all as specified and directed.
S&F fuel pipes with benjo bolt and washers for fuel pipe up to capacity 63 KVA DG set complete all as specified and directed.
S&F replacement of automatic voltage regulator for rating 0-90 V for the DG set KVA up to 63 KVA complete all as specified and directed.
S&F in replacement Power contactor 3 phase, 4 pole 32 Amp , complete all as specified and directed.
S&F in replacement Power contactor 3 phase, 4 pole 25 Amp complete all as specified and directed.
S&F in replacement battery charger 12 V with all accsories 5 Amp connected and testing complete all as specified and directed.
Servicing of AMF Panel suitable for 5 KVA DG Set to 63 KVA DG Set including cleaning properly with blower, checking of control wiring , replacement of burnt out / damaged wiring connections, calibration of control relay, replacement of control fuses / MCBs complete all as specified and directed. [Note : S&F of spare parts as mentioned under item No. 2.43 to 2.47 shall be measured and paid separately in respective item of this schedule if required.]
S&F in repairs MCCB 63 Amp 3 phase, 4 pole, 25 KA (adjustable thermal setting & fixed magnetic setting, 415 V) complete all as specified and directed.
S&F in repairs MCCB 100 Amp 3 phase, 3 pole, 16 KA (fixed thermal & fixed magnetic setting, 415V) complete all as specified and directed.
S&F in repairs MCCB 160 Amp 3 phase, 4 pole, 36 KA (adjustable thermal & fixed magnetic setting, 415V) complete all as specified and directed.
S&F in repairs MCCB 200 Amp 3 phase, 4 pole, 36 KA (adjustable thermal & fixed magnetic setting, 415V) complete all as specified and directed.
S&F in replacement PLC type controller for AMF panel model no PROCOM ECON-M-322 or equivalent complete all as specified and directed.
Supply and laying galvanised iron pipe of size 80 mm bore of medium grade with all tube fittings (such as bends, elbows, tees, short pieces of medium grade , connectors, back-nuts, caps, plugs and unions etc.) laying in trenches/ floors/ ducts and also cutting pipes, screwing, and for making forged bends on piping as required including and complete all as specified and directed.
Supply & laying in repair in trenches of XLPE UG cable insulated aluminium stranded conductor served with an inner sheathing or PVC tape armoured GI steel strip and overall PVC sheathed nominal cross sectional area 70 sqmm 4 core and testing complete all as specified and directed.
Making all arrangement for dismantling of Submersible pump set of 2 HP capacity after disconnecting the complete electrical connection and dismantling complete pipes and taking out for workshop for repair/rewinding with suitable size of copper wire, complete all as specified and directed.
Making all arrangement for dismantling of air blower for STP of 5 HP capacity after disconnecting the complete electrical connection and dismantling complete pipes and taking out for workshop for repair /rewinding with suitable size of copper wire/fill of suitable compessor oil and refixing on same place, complete all as specified and directed. Make of Air Compressor : Air Inductor Make of Air Compressor Motor : Crompton Greaves
Repairs to pump impeller for 2-5 HP motor, complete all as specified and directed. Make of Pump : Crompton Greaves
Replacement of pump ball bearing for 2-5 HP pump matching to the existing one, complete all as specified and directed. Make of Pump : Crompton Greaves
Supply only Sodium Hypochlorite (NaOCL), Grade - 2 keeping quality & as per IS : 11673 : 1992 & comply the test result as per 5.3 of IS : 11673 : 1992 with available chlorine 15% with packed in 45 Kgs plastic drums for sewage treatment chemical each, complete all as specified and directed. [Note : (a) The contractor shall produce manufacturers "Certificate of Compliance" indicating date of manufacturer in original alongwith every consignment of supply. (b) Test certificate from Govt approved Test Laboratory shall accompany with every consignment of supply to ensure that the materials supplied are in with conformity with relevant IS. (c) Necessary RV to be prepared & entered in MB for payment. (d) Payment shall be made after satisfying independent test report conducted by AGE (I) Nabagram and submission of manufacturer's test certificate]
Supply only bleaching powder of grade confirming to IS-1065-1989 (2nd Revision) minimum markable chlorine 33.5% by mass packed in HDPE bag of 25 Kg capacity ISI marked, complete all as specified and directed. [Note : (a) The contractor shall produce manufacturers "Certificate of Compliance" indicating date of manufacturer in original alongwith every consignment of supply. (b) Test certificate from Govt approved Test Laboratory shall accompany with every consignment of supply to ensure that the materials supplied are in with conformity with relevant IS. (c) Necessary RV to be prepared & entered in MB for payment. (d) Payment shall be made after satisfying independent test report conducted by AGE (I) Nabagram and submission of manufacturer's test certificate]
Supply and replacing of PVC insulated and PVC sheathed submersible cable of 6 Sqmm 3 core multi stranded copper conductor, complete all as specified and directed.
Excavation in trenches in soft/ loose soil n.exc 1.5mtr wide and not exc 1.5mtr in depth and getting out complete all as specified and directed.
M&L Sand cushioning with dry, dirtless, clear, washed river sand (Sand covering using Tibba sand) for underground cable protection complete all as specified and directed. [Note :- For the purpose of payment, only punned thickness which required to be comes out 18 cm will be measured and paid as per site measurement.]
Supply and laying Sub Class "B" Bricks Designation 75 as in cable Protection of size 250mmx125mmx50mm complete all as specified and directed.
Returning, filling, in including spreading, leveling , watering and well ramming in layers n.exc 25 cm in soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtrs above the starting point complete all as specified and directed.
Note: The abstract for the pricing of work shall be prepared separately for different part of Sch A BOQ item for payment in RAR/ final bill.
M/S ABHINABA ENTERPRISE (BID ID -3263209)
SAI ENGINEERING (BID ID -3269010)
M.SK CONTRACTOR (BID ID -3267376)
ANSH CONSTRUCTION (BID ID -3269808)
Abida Enterprises (BID ID -3270021)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .