Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance 502 31 45 15 41 JAYANTHI JACINTH APARTMENT PHASE 2 PRASANTHI NAGAR KURAMANNAPALEM VISAKHAPATNAM ANDHRA PRADESH 530046 UDYAM AP 10 0014243 | VISAKHAPATANAM | ANDHRA PRADESH | 530046 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance DOOR NO 50 13 27 14 FLAT NO 14 PADMAJA APARTMENTS SEETHAMMAPETA VISAKHAPATNAM 530016 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530016 | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
Closing Date
6 Jan 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Azmat arshi
GE(P)(N) Kalinga
Provision of Deficient Magazines for MIG 29 K at NAD Bheemunipatnam
2022_MES_572082_1
GE(P)/N/K/JOB /25 of 2022-23
Limited
Miscellaneous Services
Item Rate
90 days
Garrison Engineer P Navy Kalinga Visakhapatnam
Provision of Deficient Magazines for MIG 29 K at NAD Bheemunipatnam
1 document required · 1 mandatory
₹0
Exempted
7 Jan 2023
30 Dec 2022
7 Jan 2023
31 Dec 2022
6 Jan 2023
31 Dec 2022
Amount
Mobilization of equipment for detailed soil Investigation and shifiting them location to location of bore holes and for in-situ tests.
Boring holes 150mm dia in any types of soil but exclding any type of rock up to a depth minimum 15m in cse of good soils I which open/ raft foundation is anticipated to be sufficient, in case of meeting rook strata within 15m or meeting weak soils in top in which case pile foundation is anticipated minimum 6.5m below the rock strata for conducting following activities: (a) Conduct of SPT at every 1.5 m interva or change of strata whicheven occur earlier. (b) Collection of undisturbed soil sample (UDS) at every 1.5 m interval or change strata whichever occurs earlier (a minimu gap of 500mm shall be ensured between SPT and collection of UDS. Note: (i) Writen permission of CWE shall be obtained for deep borehole when pile foundation is contemlated. (ii) incase of deep bore holes anticipating pile foundation at least boreholes in all 4 corner of the building shall go upto 6.5m below rock strata.
Drilling holes in any type of rock (Soft/Hard) using hydraulic drilling machine within the borehole for cutting cores in rock and collection of cores of requites size and length as per relevant IS standards. Logging core Recovery. Drilling shall continue till minimum 5m into hard rock strata. Conduct of following laboratory tests on rock sample/ cores collected from boreholes as per relevant Indian Standerd(( see IS 2720( all Parts) and IS 1498, IS 9143, IS 13030, IS 9221, IS 8764, IS 9179, IS IS 10050, IS 10082, IS 10782, IS 12608, IS 13047, IS 3025)) (II)(a) Visual Classification. (b) Density (c) Specific Gravity (d) Hardness (e) Slake durability/ degree of weathering (f) Uniaxial compression test ( crushing strength) ( both saturated and unsaturated) (g) Point load strength index (h) RQD ( Rock Quality Designation) Note : Item to be operated only incase of encountering rock in borehole with the written permission of GE
(a) Visual Classification. (b) Density (c) Specific Gravity (d) Hardness (e) Slake durability/ degree of weathering (f) Uniaxial compression test ( crushing strength) ( both saturated and unsaturated) (g) Point load strength index (h) RQD ( Rock Quality Designation) Note : Item to be operated only incase of encountering rock in borehole with the written permission of GE
Conduct of following laboratory tests as per relevant indian standards IS 2720 (all parts) IS 1498 and IS 3025 of soil samples collected. (a) Test on disturbed/undistubed samples:- (i) Visual and engineering classification. (ii) Sieve analysis and hydrometer analysis. (iii) Atterberg limits (liquid limit, plastic limit and shrinkage limit). (iv) Specific gravity. (v) Free swell index. (b) Test as on Undisturbed samples. (i) Bulk density and moisture content. (II) Unconfined compression test (on remoulded undisturbed sample). (iii) Swelling Pressure (on remoulded undisturbed sample) (iv) Determination of C&O valvues using direct shear (drained/undrained)(on remoulded or undisturbed or remoulded sample) or vane shear test
Chemical analysis of ground water sample collected at bottom of one bore hole.
Chemical analysis of soil samples one each from each strata in respect of one bore hole if different strata (s) encountered in any other borehole additionals soils samples to be analysed
Conduct of california bearing ration (CBR) Test in accordance with IS 2720 (Part 16) on soil sample collected at subgrade level for road with flexible wearing course
Conduct of plate load test to detemine " subgrade modulus " in accordance with IS 9214 at subgrade level for road with Rigid wearing course. Note: Composition of subsurface Investigation report 1. General On completion of the in-site and laboratory tests, subsurface investigation report shall be prepared which should include geological information, procedure adopted for investigation, field observations, laboratory or test data, analysis, interpretation, recommendations etc.1.2 Information to be provided: The report shall include but not be limited to the following: a) Dimensioned Plan showing location and depth of in-situ tests; the co-ordinates of bore hole locations with reference to prominent permanent features of the site duly signed by GE and Geo consultant; b) Geological information of the area; c) General topography of the site, duly marking RL of the location of bore holes with reference to RL of nearby permanent features available at site duly signed by GE and Geo Consultant; d) Past usage and historical data of the site, if available. Information regarding flooding of the site in the past, High flood level etc. e) Borelog and trial pit log duly signed by GE and Geo Consultant. f) In-situ test results; g) Plot of standard penetration test (N values both uncorrected and corrected) with depth for identified areas; h) Laboratory test results i) Summary of strata profile and j) In case of pressure meter tests the following should be furnished: 1) Calibration record including, description of membrane and sheath on probes, dimension of thick walled cylinder, length of flexible tubing, calibration curves/chart, temperature, etc. 2) Drilling record including, borehole number, method of making borehole, log of soil type and condition, depth of water in borehole, weather and temperature. 3) Test Record: Type of test, date and time, depth of centre point of probe, volume readings at 30 s and 60 s elapsed time and corresponding pressure readings, notes on any deviation from standard test procedure. Field pressure mater, creep and air calibration curves indicating P0, Pf and PI, corrected pressure meter and creep curves indicating P0, Pf & PI along with calculation for the corrections. 1.2.1 Reporting of in-situ and laboratory test results should be in accordance with relevant Indian Standards. 1.3.1 Analysis and Interpretation of Results. The following shall be included in the report: a) Analysis of test results. b) Discussion and interpretation of results analyzed including basis of adopting design parameters for the substrata, c) For shallow foundations 1) Net allowable bearing pressure considering shear, settlement criteria as well as SPT value for isolated footing, continuous strip footing and raft foundation at depth 1.5 m, 2.0 m, 2.5 m and 3.00 m. For calculations IS: 6403 shall be used. 2) Modulus of subgrade reaction and modulus of elasticity of substrata. 3) In case of UG Sumps/ Swimming pools K value from 0.5m to 5.0m depth. d) For pile foundations: Safe load carrying capacity (compression, pull out and horizontal with free head as well as supported head pile load capacities shall be worked out for 300,400,450 & 500 for under reamed piles and for 450, 500, 600, 750 dia for end bearing piles. e) If weak soil with lesser N value as specified in table-1 of IS 1893 (part-1) 2016 is encountered then evaluation of liquefaction potential shall be assessed and remedial actions to be adopted shall be specified. f) Suitability of the soil for backfilling around foundations/ filling under floors. g) Susceptibility of sub-soil strata to liquefaction, if any, in the event of dynamic loading h) Remedial measures against the presence of harmful chemicals in the sub-soil/ground water j) Remedial measures for foundation footings, plinth beams and filling under floors in case of meeting expansive 2. The soil investyigation report should be vtted by any IIT/NIT/Andhra University. 3. CD Containing video evidence of depth of each bore hole & machinery deployed at site by kept in record. Undisturbed samples shall also be colected @ 1.5 m interval or change of strata. However there shall be minimum gap of 500mm between SPT and collection UDS,
SRIVALLI ENGINEERS
ROHANPUSAN AUTO POWER LINE
SRI SRK ENGINEERS
HUSSAIN ENGINEERING WORKS
Grace Info Systems
stage.html
html • 0.03 MB
finance_640822.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .