Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.5 LAccepted-AOC FIRST FLOOR PLOT NO 440 SECTOR NO 1 GAYATRI MANDIR ROAD GANDHIDHAM KACHCH GUJARAT 370201 | KACHCHH | GUJARAT | 370201 | 1 | Accepted-AOC AOC | |
| 2 | 2₹7.2 L+₹47,775 (7.14%)Rejected-Finance LESUWA BHACHABHAR RAMSAR | RAMSAR | BARMER | RAJASTHAN | 2 | Rejected-Finance not lowest | |
| 3 | 3₹7.6 L+₹95,440 (14.3%)Rejected-Finance | 3 | Rejected-Finance not lowest |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
4 Jun 2022, 6:00 pmClosed
GE ARMY BHUJ
GE ARMY BHUJ
CLEANING AND REPAIRS TO SEWAGE LINE, SEPTIC TANK, SOAK PIT AND AREA DRAINAGE AT MIL STN GANDHIDHAM
2022_MES_515148_2
8891
Open Tender
Civil Works
Item Rate
180 days
ARMY AREA GANDHDHAM
REFER TENDER
6 documents required · 6 mandatory
₹500
GE ARMY BHUJ
₹16,000
Yes
14 Sept 2023
14 May 2022
6 Jun 2022
14 May 2022
4 Jun 2022
23 May 2022
Amount
Taking out liquid sludge including floating sludge contents from septic tank of any description and in any position and cleaning septic tank up to bottom including walls to any depth from ground level by pumping through sewage disposal pump / honey sucker pump (as directed by the Engr-in-charge and as on requirement basis) and removing the liquid sludge outside of the MD land or nearer man hole of civil sewage line in such a manner that there shall be no nuisance and no unhygienic environment complete all as specified and directed. Note: Pump, honey sucker pump and sludge removal van / vehicles shall be arranged by contractor at his own cost and nothing extra shall be governed by the Deptt.
Dewatering complete filter bed of any description, in any position by pumping through sewage disposal pump / honey sucker pump (as directed by the Engr-in-charge and as on requirement basis) up to the bottom / bed outlet of dewatering at least 50 mtr away as and when required and removing in such a manner that there shall be no nuisance and no unhygienic environment complete all as specified and directed. The following user capacity (a) Upto 20 User
(b) 21 to 50 User
(c) 51 to100 User
(c) 101 to 300 User
Taking out sedimented sludge left out after taking out and removing liquid sludge / effluent from septic tank of any description, in any position and of any depth and removing the sludge depositions as directed, cleaning septic tank up to bottom, including walls and removing and disposal of the sedimented / solid sludge outside the cantonment being contractor's property as per Sch of credit and removing in such a manner that there shall be no nuisance and no unhygienic environment complete all as specified and directed. Note: Pump, honey sucker pump and sludge removal van / vehicles shall be arranged by contractor at his own cost and nothing extra shall be governed by the Deptt.
Cleaning of existing chocked / blocked sewage lines of any description and in any position by taking out loose sediment sand, girt, ash, sludge water, rags, fibre or vegetation from the sewage line of 150 mm bore buried in ground to any depth from GL including removal of sludge / debris outside the cantonment area in such a manner that there shall be no nuisance and no unhygienic environment at the place of disposal also complete all as specified and directed. Note: Pump, honey sucker pump and sludge removal van / vehicles shall be arranged by contractor at his own cost and nothing extra shall be governed by the Deptt.
Cleaning of existing chocked / blocked sewage lines of any description and in any position by taking out loose sediment sand, girt, ash, sludge water, rags, fibre or vegetation from the sewage line of 200 mm bore buried in ground to any depth from GL including removal of sludge / debris outside the cantonment area in such a manner that there shall be no nuisance and no unhygienic environment at the place of disposal also complete all as specified and directed. Note: Pump, honey sucker pump and sludge removal van / vehicles shall be arranged by contractor at his own cost and nothing extra shall be governed by the Deptt.
Opening and cleaning of blockage of kitchen / bath traps or WC any pattern and in any position by rodding, manually or mechanically (as directed by Engr-in-charge and as on requirement basis) upto 1st manholes complete all as specified and directed.
Cleaning of blocked man hole of any description and in any position depth not exc 1.5 m deep mechanically or manually by taking off sludge waste / night soil and silted soil from the existing manhole of any size collecting and removal of sludge in sealed container out of the cantonment area in such a manner that there shall be no nuisance and no unhygienic environment at the place of disposal also complete all as specified and directed.
Cleaning of blocked man hole of any description and in any position depth exc 1.5 m but not exc 3 m deep mechanically or manually by taking off sludge waste / night soil and silted soil from the existing manhole of any size collecting and removal of sludge in sealed container out of the cantonment area in such a manner that there shall be no nuisance and no unhygienic environment at the place of disposal also complete all as specified and directed.
Cleaning of open drains completely removing silt, soil, mud sludge, vegetation growth etc. and removing the same to out side MoD land all as directed by Engr-in-Charge for width of drains exc. 30cm and n exc 60cm complete all as specified and directed.
Cleaning of open drains completely removing silt, soil, mud sludge, vegetation growth etc. and removing the same to out side MoD land all as directed by Engr-in-Charge for width of drains exc. 60 cm but n.exc. 100 cm complete all as specified and directed.
Demolition of cement concrete of any description and in any position (unreinforced) in ground floors/ paving not exceeding 15 cm thick (below or above GL) and disposing off rubbish off the premises of cantonment complete all as specified and directed.
M & L for PCC 1:4:8 type D-2 (using 40 mm graded stone aggregates) as in foundation of manholes, mass concrete etc. complete all as specified and directed.
Demolition of precast concrete block walling and similar items i.e. ashlar facing dressing stone work, precast concrete articles etc of any description and in any position built in cement mortar including all quoins, arches and pillars etc and disposing off rubbish) off the premises of cantonment
M & L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in Modular bricks in cement mortar 1:6 including curing,racking of joints etc. complete all as specified & as directed.
M & L for PCC 1:3:6 type C-1 (using 20 mm graded stone aggregates) as in coping and finishing the exposed surfaces even and smooth by using extra cement including necessary form work complete all as specified and directed.
M&L for PCC 1:2:4 type B2 (using 40mm graded aggregate) as in benching of surface channels/manholes including fair finishes of surfaces chamfering, throating and weathering and necessary form work complete as specified and directed.
M & L for rendering 15 mm thick in CM 1:4 on concrete / fair surfaces of block masonary and including mixing water proofing compound as per manufactureres instructions complete all as specified and directed. Note :- Water proofing compound shall be measured and paid for seperately under appropriate item of Sch "A' as supply only
Supply only liquid water proofing compound complete all as specified and directed.
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 m in depth for foundation, for laying / taking down sewage / water supply lines, forming bottom surfaces to required slope & gradient and not exc 10 sqm on plan and not exc 1.5 m in depth and getting out in soft/loose type of soil complete all as specified and directed.
Excavation in trenches not exc. 1.5 m wide and depth exc 1.5 m deep but not exc 3 mtr deep for foundation, for laying / taking down sewage / water supply lines, forming bottom surfaces to required slope & gradient and not exc 10 sqm on plan and getting out in soft/loose type of soil complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed stone ware, AC or reinforced concrete) 150 mm dia pipe of any description and in any position set and jointed in cement mortar and Supplying, fixing, jointing and testing reinforced concrete drain pipes 150 mm bore, class NP-2, laid and jointed with collar in CM 1:1 complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed stone ware, AC or reinforced concrete) 200 mm dia pipe of any description and in any position set and jointed in cement mortar and Supplying, fixing, jointing and testing reinforced concrete drain pipes 200 mm bore, class NP-2, laid and jointed with collar in CM 1:1 complete all as specified and directed.
M & L for concrete bed to drain pipes in PCC 1:4:8 type D-2 (using 40 mm graded stone aggregates) including packing under and haunching against the side of the pipes after they are laid tested for pipes of 150 mm dia complete all as specified and directed
M & L for concrete bed to drain pipes in PCC 1:4:8 type D-2 (using 40 mm graded stone aggregates) including packing under and haunching against the side of the pipes after they are laid tested for pipes of 200 mm dia complete all as specified and directed
Demolition of Reinforced Concrete of any description and in any position not otherwise specifically provided and M & L for pre-cast cement concrete in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces in RCC 1:2:4 Type B-1 (using 20 mm graded stone aggregates) and placing in position and set in CM 1:4 complete all as specified and directed.
M & L for mild steel TMT bar 10 mm dia and over as in reinforcement cut to length bent to shape required including cranking, bending etc and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M & L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC 1:2:4 type B-2 (using 40 mm graded stone aggregates ) smooth finished, and reforming benching as required for 150mm dia of pipe complete all as specified and directed.
M & L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC 1:2:4 type B-2 (using 40 mm graded stone aggregates ) smooth finished, and reforming benching as required for 200mm dia of pipe complete all as specified and directed.
Returning, filling in the any type of soil including spreading, levelling. Watering and well ramming in layers not exceeding 25 cm thick each layer complete all as specified and directed.
Removing the excavated soil to a distance not exceeding 50 metres away depositing where directed at a level not exceeding 1.50 metres above the starting point complete all as specified and directed.
M/s Naganaray construction Company
Sai Ram Electricals and Refrigeration Works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .