| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.7 LAccepted-Finance | 1 | Accepted-Finance Low Rate | |
| 2 | Rejected-Technical THAYYILTHAZHAM KONOTT P O KOZHIKODE 673 571 | KOZHIKODE | KOZHIKODE | KERALA | 673571 | - | Rejected-Technical High Rate | |
| 3 | Rejected-Technical | - | Rejected-Technical High Rate |
| Sl No | Description | Qty | Unit | SREELESH P G L3 | BABU VALLIL L1 | K MANOHARAN L2 |
|---|---|---|---|---|---|---|
| 1.00Electrification | ||||||
| 1.00 | 1.11:Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. | 1 | point | 1,652 ₹1,652 | 1,500 ₹1,500 | 1,444.26 ₹1,444.26 Lowest |
| 1.00 | 1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire | 220 | metre | 246 ₹54,120 | 130 ₹28,600 Lowest | 214.97 ₹47,293.4 |
| 1.00 | 1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 35 | metre | 291 ₹10,185 | 150 ₹5,250 Lowest | 253.84 ₹8,884.4 |
| 1.00 | 1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire | 55 | metre | 353 ₹19,415 | 190 ₹10,450 Lowest | 308.26 ₹16,954.3 |
| 1.00 | 1.14.4:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire | 7 | metre | 464 ₹3,248 | 350 ₹2,450 Lowest | 404.96 ₹2,834.72 |
| 1.01 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm | 101 | metre | 100 ₹10,100 | 50 ₹5,050 Lowest | 87.74 ₹8,861.74 |
| 1.01 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm | 35 | metre | 135 ₹4,725 | 50 ₹1,750 Lowest | 118.35 ₹4,142.25 |
| 1.01 | 1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm | 3 | metre | 194 ₹582 | 150 ₹450 Lowest | 169.84 ₹509.52 |
| 1.01 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch | 10 | each | 108 ₹1,080 | 50 ₹500 Lowest | 94.84 ₹948.4 |
Tender Value
₹4 L
EMD Value
₹10,000
Closing Date
13 Feb 2026, 6:00 pmClosed
Secretary
Secretary Unnikulam Grama Panchayat Ekarool PO673574
Annual Plan-UNNIKULAM GP -IYYAD SUBCENTRE ELECTRIFICATION-Project No S0341-25 Iyyad Subcentre Electrification- General Electrical Work
2026_DP_832967_1
No- LSGD-CELSGD-124537-2025-2026
Open Tender
Loading Works/ Services
Supply and Service
30 days
Unnikulam
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Yes
₹10,000
Yes
9 Oct 2026
3 Feb 2026
16 Feb 2026
3 Feb 2026
13 Feb 2026
3 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Electrification | |||||
| 1.001 | 1.11:Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. | 1 | point | - | - |
| 1.002 | 1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire | 220 | metre | - | - |
| 1.003 | 1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 35 | metre | - | - |
| 1.004 | 1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire | 55 | metre | - | - |
| 1.005 | 1.14.4:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire | 7 | metre | - | - |
| 1.006 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm | 101 | metre | - | - |
| 1.007 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm | 35 | metre | - | - |
| 1.008 | 1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm | 3 | metre | - | - |
| 1.009 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch | 10 | each | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
finance_1400523.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
Agreement.pdf
Additional Documents • 0.19 MB
BOQ_1400523.xls
BOQ • 0.35 MB
SBDIYYADSUBCENTREELECTRIFICATION.pdf
Additional Documents • 1.92 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .