Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
8 Jun 2024, 6:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Exe Eng Jal Shakti (PHE) Mech Div North Sopore
Exe Eng Jal Shakti (PHE) Mech Div North Sopore
Rate contract
2024_PHE_249072_1
PHE/MDNS/NIT/JJM/E-03 of 2024-25
Open Tender
Repair and Maintenance Services
Item Rate
3 days
North Kashmir
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
Yes
Exe Eng Jal Shakti (PHE) Mech Div North Sopore
₹90,000
Yes
24 Jun 2024
3 Jun 2024
10 Jun 2024
3 Jun 2024
8 Jun 2024
3 Jun 2024
Providing, fitting and testing of Copper thimbles at site
Providing, fitting and testing of Aluminum thimbles at site
Providing, fitting of below mentioned item for repairs to 25KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Copper wire of specific gauge for fabrication of primary / secondary coil
Bush rod with porcelain insulator and packing
Re-taping /re-insulation of coils
Copper strip
Filtration / dehydration of T-oil
Cost of damaged lamination
Providing, fitting of below mentioned item for repairs to 30KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Copper wire of specific gauge for fabrication of primary / secondary coil
Bush rod with porcelain insulator and packing
Re-taping /re-insulation of coils
Copper strip
Filtration / dehydration of T-oil
Cost of damaged lamination
Providing, fitting of below mentioned item for repairs to 35KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Copper wire of specific gauge for fabrication of primary / secondary coil
Bush rod with porcelain insulator and packing
Re-taping /re-insulation of coils
Copper strip
Filtration / dehydration of T-oil
Cost of damaged lamination
Providing, fitting of below mentioned item for repairs to 40KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Copper wire of specific gauge for fabrication of primary / secondary coil
Bush rod with porcelain insulator and packing
Re-taping /re-insulation of coils
Copper strip
Filtration / dehydration of T-oil
Cost of damaged lamination
Providing, fitting of below mentioned item for repairs to 50KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Copper wire of specific gauge for fabrication of primary / secondary coil
Bush rod with porcelain insulator and packing
Re-taping /re-insulation of coils
Copper strip
Filtration / dehydration of T-oil
Cost of damaged lamination
Providing, fitting of below mentioned item for repairs to 75KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Copper wire of specific gauge for fabrication of primary / secondary coil
Bush rod with porcelain insulator and packing
Re-taping /re-insulation of coils
Copper strip
Filtration / dehydration of T-oil
Cost of damaged lamination
Providing, fitting of below mentioned item for repairs to 100KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Copper wire of specific gauge for fabrication of primary / secondary coil
Bush rod with porcelain insulator and packing
Re-taping /re-insulation of coils
Copper strip
Filtration / dehydration of T-oil
Cost of damaged lamination
Providing, fitting of below mentioned item for repairs to 150KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Copper wire of specific gauge for fabrication of primary / secondary coil
Bush rod with porcelain insulator and packing
Re-taping /re-insulation of coils
Copper strip
Filtration / dehydration of T-oil
Cost of damaged lamination
Providing, fitting of below mentioned item for repairs to 250KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Copper wire of specific gauge for fabrication of primary / secondary coil
Bush rod with porcelain insulator and packing
Re-taping /re-insulation of coils
Copper strip
Filtration / dehydration of T-oil
Cost of damaged lamination
Providing, fitting of below mentioned item for repairs to 400KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Copper wire of specific gauge for fabrication of primary / secondary coil
Bush rod with porcelain insulator and packing
Re-taping /re-insulation of coils
Copper strip
Filtration / dehydration of T-oil
Cost of damaged lamination
Providing, fitting of below mentioned item for repairs to 450KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Copper wire of specific gauge for fabrication of primary / secondary coil
Bush rod with porcelain insulator and packing
Re-taping /re-insulation of coils
Copper strip
Filtration / dehydration of T-oil
Cost of damaged lamination
Providing, fitting of below mentioned item for repairs to 600KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Copper wire of specific gauge for fabrication of primary / secondary coil
Bush rod with porcelain insulator and packing
Re-taping /re-insulation of coils
Copper strip
Filtration / dehydration of T-oil
Cost of damaged lamination
Providing and fitting of single plate type Voltage regulator including extraction of damaged one, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
150mmx150mm
225mm x 225mm
200mm x 200mm
250mm x 250mm
450 mm x 450 mm
375mmx 375mm
600 mm x 600 mm
Providing and fitting of type Voltage regulator including extraction of damaged one, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
450 mm x 450 mm (Single Plate)
600 mm x 600 mm (Single Plate)
450 mm x 450 mm (Double Plate)
600 mm x 600 mm (Double Plate)
Providing and fitting of drum type Voltage regulator including extraction of damaged one, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Providing, fitting and testing of Voltmeters at site
Providing, fitting and testing of Ammeters at site
0-50A with CT ratio of 5/50
0-100A with CT ratio of 5/100
0-150A with CT ratio of 5/150
0-200A with CT ratio of 5/200
0-300A with CT ratio of 5/300
0-400A with CT ratio of 5/400
Providing, fitting and testing of post type drop out set including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Suitable for 25KVA Sub-station
Suitable for 63KVA Sub-station
Suitable for 100KVA Sub-station
Suitable for 250KVA Sub-station
Suitable for 630KVA Sub-station
Suitable for 33KV, 630KVA Sub-station (Heavy duty)
Providing, fitting and testing of link set including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Suitable for 25KVA Sub-station
Suitable for 63KVA Sub-station
Suitable for 100KVA Sub-station
Suitable for 250KVA Sub-station
Suitable for 630KVA Sub-station
Suitable for 33KV, 630KVA Sub-station (Heavy duty)
Providing, fitting and testing of polymer type pin insulator including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Suitable for 11 KV HT line
Suitable for 33 KV HT line
Providing, fitting and testing of heavy duty 33 KV isolator (complete assembly) including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Replacement of damaged knives of isolator including greasing and alignment. The job includes extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Replacement of damaged grip assembly of isolator including greasing and alignment. The job includes extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Providing, fitting and testing of submersible copper cables of below mentioned specifications including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Providing, fitting and testing of copper cables of below mentioned specifications including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Providing, fitting and testing of 3.5 core XLPE aluminum conductor of below mentioned specifications including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Providing, fitting and testing of 11KV post type lightening arrestor including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Providing, fitting and testing of 33KV post type lightening arrestor (heavy duty) including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Providing, fitting and testing of G.O.D set including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Providing, fitting and testing of Cross arms including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Channels 75x40
Angle iron support
U Clamps
Guy-wire with turn buckle
Guy-Insulator
Providing, fitting and testing of ACSR Conductor including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Providing, fitting and testing of MCCBs (04 Pole) with breaking capacity of 35KA of approved make as per damaged MCCB at site including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Providing, fitting and testing of MCCBs (04 Pole) with breaking capacity of 50KA of approved make as per damaged MCCB at site including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Providing, fitting and testing of MCCBs (03 Pole) with breaking capacity of 35KA of approved make as per damaged MCCB at site including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Providing, fitting and testing of MCCBs (03 Pole) with breaking capacity of 50KA of approved make as per damaged MCCB at site including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Providing, fitting and testing of on load 04 pole Change over switch of approved make as per damaged change over switch at site including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Providing, fitting and testing of Combined volt-ammeter for MU-G starters
Providing, fitting and testing of 415V Indicating lamps
Yellow
Green
Providing, fitting and testing of 415V Single phase preventor
Providing, fitting and testing of ML contactors for starters
Providing, fitting and testing of Power contactors for FASD starters
Providing, fitting and testing of ML relays
ML1 range 4-6.5
ML1 range 6-10
ML1 range 10-16
Providing, fitting and testing of FASD Panel accessories
Electronic timer 0- 30Sec
Electronic timer 0- 60Sec
Single Phase Preventer (Three phase type )
Overload relay 4A-6A
Overload relay 5A-8A
Overload relay 6A-9A
Overload relay 7A-10A
Overload relay 9A-13A
Overload relay 12A-16A
Overload relay 14A-22A
Overload relay 17A-25A
Overload relay 23A-32A
Overload relay 30A-40A
Overload relay 37A-50A
Overload relay 48A-65A
Overload relay 55A-70A
Overload relay 63A-80A
Overload relay 80A-93A
Overload relay 85A- 105A
Overload relay 80A- 115A
Overload relay 125A- 200A
Overload relay 160A- 250A
Overload relay 200A- 315A
Overload relay 250A- 400A
Overload relay 315A- 500A
Overload relay 400A- 630A
Overload relay 500A- 800A
Overload relay 630A- 1000A
Replacement of damaged 1 Sq mm copper power wiring
Providing, fitting and testing of ATS star Delta starter
Pneumatic timer (on delay/off delay)
Electromagnetic power contactor assembly (10A-250A)
Providing, fitting and testing of Contact points of contactors for star/delta starters
Providing, fitting and testing of Terminal block
Providing, fitting and testing of Power contactor for MU-G starters
Providing, fitting and testing of controller for MU-G starters
Providing, fitting and testing of Overload relay/under voltage relay for MU-G starters
Providing and fitting of Air Circuit breaker 630 amp Manual Draw out type
Providing and fitting of Air Circuit breaker 800 amp Manual Draw out type
Providing and fitting of GSM based remote access motor control module complete replacement. Model MPU-LCD
Providing, fitting and testing of Motor protection circuit breakers with thermal adjustable ranges from 0-100 amp
0-32 Amp (16 steps)
28-63 Amp (03 steps)
55-100 Amp (03 steps)
Providing and fitting of Water level control relay with capsule modules and wiring 1 Sq mm copper minimum 90 Meters
Nuts and bolts of different size
Providing, fitting of below mentioned item for repairs to 10KVA to 50KVA Servo Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Replacement of digital micro controlled processor based control card
Replacement of AC syncronous servo motor
Replacement of copper wound motorized auto transformer
Replacement of buck and boost series transformer
Providing, fitting of below mentioned item for repairs to 50KVA to 100KVA Servo Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Replacement of digital micro controlled processor based control card
Replacement of AC syncronous servo motor
Replacement of copper wound motorized auto transformer
Replacement of buck and boost series transformer
Providing and fitting of LED Lamps with angle/straight holders with backlite plate at site
Erection of MS tubular 9m/11m tilted pole by way of excavation of new trench and concrete bottoming including fitting/fixing of Departmental ACSR conductor on the insulators
Repairs to VT Motor with rating from 10HP to 50HP Dismantling of the VT motor at site, shifting to the workshop, repairing, shifting back to site, re-fitting and successfull testing on full load. Job includes repairing / fabrication and providing / replacement of following items.
Copper wire used in rewinding the motor.
Associated/consumable items like crimpled paper, sleeves, PVC paper, bamboo sticks, thread, varnish etc.
Repairs to VT Motor with rating above 50HP to 150HP) Dismantling of the VT motor at site, shifting to the workshop, repairing, shifting back to site, re-fitting and successfull testing on full load. Job includes repairing / fabrication and providing / replacement of following items.
Copper wire used in rewinding the motor.
Associated/consumable items like crimpled paper, sleeves, PVC paper, bamboo sticks, thread, varnish etc.
Repairs to VT Motor with rating above 150HP to 270HP) Dismantling of the VT motor at site, shifting to the workshop, repairing, shifting back to site, re-fitting and successfull testing on full load. Job includes repairing / fabrication and providing / replacement of following items.
Copper wire used in rewinding the motor.
Associated/consumable items like crimpled paper, sleeves, PVC paper, bamboo sticks, thread, varnish etc.
Repairs to horizontal Motor with rating from 5HP to 50HP Dismantling of the horizontal motor at site, shifting to the workshop, repairing, shifting back to site, re-fitting and successfull testing on full load. Job includes repairing / fabrication and providing / replacement of following items.
Copper wire used in rewinding the motor.
Associated/consumable items like crimpled paper, sleeves, PVC paper, bamboo sticks, thread, varnish etc.
Repairs to horizontal Motor with rating above 50HP to 100HP Dismantling of the horiontal motor at site, shifting to the workshop, repairing, shifting back to site, re-fitting and successfull testing on full load. Job includes repairing / fabrication and providing / replacement of following items.
Copper wire used in rewinding the motor.
Associated/consumable items like crimpled paper, sleeves, PVC paper, bamboo sticks, thread, varnish etc.
Repairs to horizontal Motor with rating above 100HP to 200HP Dismantling of the horiontal motor at site, shifting to the workshop, repairing, shifting back to site, re-fitting and successfull testing on full load. Job includes repairing / fabrication and providing / replacement of following items.
Copper wire used in rewinding the motor.
Associated/consumable items like crimpled paper, sleeves, PVC paper, bamboo sticks, thread, varnish etc.
Repairs to submersible Motor with rating from 2HP to 50HP Dismantling of the submersible motor at site, shifting to the workshop, repairing, shifting back to site, re-fitting and successfull testing on full load. Job includes repairing / fabrication and providing / replacement of following items.
Copper wire used in rewinding the motor.
Gun metal bushes
Ratchet racer assembly
Associated/consumable items like crimpled paper, sleeves, PVC paper, bamboo sticks, thread, varnish etc.
Repairs to submersible Motor with rating from and above 50HP to 75HP Dismantling of the submersible motor at site, shifting to the workshop, repairing, shifting back to site, re-fitting and successfull testing on full load. Job includes repairing / fabrication and providing / replacement of following items.
Copper wire used in rewinding the motor.
Gun metal bushes
Ratchet racer assembly
Associated/consumable items like crimpled paper, sleeves, PVC paper, bamboo sticks, thread, varnish etc.
Repairs to submersible Motor with rating from and above 75HP to 100HP Dismantling of the submersible motor at site, shifting to the workshop, repairing, shifting back to site, re-fitting and successfull testing on full load. Job includes repairing / fabrication and providing / replacement of following items.
Copper wire used in rewinding the motor.
Gun metal bushes
Ratchet racer assembly
Associated/consumable items like crimpled paper, sleeves, PVC paper, bamboo sticks, thread, varnish etc.
Replacing of damages illumination single core multistranded copper wiring
Providing and fitting of bimetallic tube terminals Al-Cu for cable thicknesses
Providing, fitting and testing of AC power monitor Proton make after extraction of damaged one
Providing, fitting and testing of VAF Meter, Model 39A, after extraction of damaged one
Providing, fitting and testing of motor protection unit MPU-12, Proton make, after extraction of damaged one
Fabrication, providing, fitting and testing of GM bushes to the submersible motors (finished)
Providing and fitting of aluminium bus bar of various sizes
Providing and fitting of copper bus bar of various sizes
Providing and fiting of PVC fans for horizontal motors
7.50HP to 10HP
12.50HP to 25HP
30HP to 60HP
60HP onwards
Providing and fiting of PVC fans for VT motors
7.50HP to 10HP
12.50HP to 25HP
30HP to 60HP
60HP onwards
Providing, fitting and testing of contactor coils after dismantling of old damamged one
Providing, fitting and testing of tripping coil to handle type starter
Upto 30HP
From 40HP to 150HP
150HP onwards
Providing, fitting and testing of Controller for MU-G starters (single phase preventer/Timer with manual, automatic, byepass function)
Repairs to open well submersible Pumping Unit with discharge from 3000GPH to 10000 GPH, head from and above 10M but less than 52M with motor rating as 1HP to 7.5HP
Dismantling of the open well submersible pumping unit at site, shifting to workshop, repairing, shifting back to site, re-fitting and successful testing on full load
Complete rewinding of the stator assembly by appropriate gauged copper wire
Cost on account of labour, insulted paper, sleeves etc., used during rewinding with testing
Cost on account of associated consumeable items like crimped paper, sleeves, PVC pipes, bamboo sticks, thread etc.
Replacement of Stain less steel shaft
Replacement of cast iron impeller
Replacement of cast iron volute casing
Providing and fitting of rubber oil seal
Providing and fitting of bronze bushes
Providing and fitting of water oil seal
Providing and fitting of stainless steel thrust pad
Providing and fitting of threaded plastic strainer
Repairs to open well submersible Pumping Unit with discharge from and above 10000GPH to 20000 GPH, head from and above 10M but less than 52M with motor rating from and above 7.5HP to 15HP
Dismantling of the open well submersible pumping unit at site, shifting to workshop, repairing, shifting back to site, re-fitting and successful testing on full load
Complete rewinding of the stator assembly by appropriate gauged copper wire
Cost on account of labour, insulted paper, sleeves etc., used during rewinding with testing
Cost on account of associated consumeable items like crimped paper, sleeves, PVC pipes, bamboo sticks, thread etc.
Replacement of Stain less steel shaft
Replacement of cast iron impeller
Replacement of cast iron volute casing
Providing and fitting of rubber oil seal
Providing and fitting of bronze bushes
Providing and fitting of water oil seal
Providing and fitting of stainless steel thrust pad
Providing and fitting of threaded plastic strainer
Repairs to ATS Starter Coil Dismantling of the ATS Starter at site, shifting to the workshop, repairing, shifting back to site, re-fitting and successfull testing on full load. Job includes repairing / fabrication and providing / replacement of following items.
Copper wire used in rewinding
Associated/consumable items like crimpled paper, sleeves, PVC paper, thread, varnish etc.
Providing and fitting of Ball/Thrust bearing (DE & NDE) for different capacity motors and pumps
No. 3206 double groove
No. 5206 double groove
No. 7220BECB
No 29330 E thrust bearing
No. 29322 E thrust bearing
No 29416 E Thrust bearing
No. NU318c3
Cost on account of copper scrap (To be deducted in allotment)
Providing, fitting and testing of 6A Switch with box
Providing, fitting of below mentioned item for repairs to 50/100KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Aluminium wire of specific gauge for fabrication of primary / secondary coil
Bush rod with porcelain insulator and packing
Re-taping /re-insulation of coils
Aluminium strip
Filtration / dehydration of T-oil
Cost of damaged lamination
Providing, fitting of below mentioned item for repairs to up to 1KVA Single Phase Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Replacement of complete coil and core
Copper rewinding of coil
Set of relays with complete wiring
Cut plate 3 in one
12-0-12 Transformer
Digital Voltmeter
Neon switches
Regulator for manual stabilizer
Providing, fitting of below mentioned item for repairs to up to 2KVA Single Phase Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Replacement of complete coil and core
Copper rewinding of coil
Set of relays with complete wiring
Cut plate 3 in one
12-0-12 Transformer
Digital Voltmeter
Neon switches
Regulator for manual stabilizer
Providing, fitting of below mentioned item for repairs to up to 5KVA Single Phase Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Replacement of complete coil and core
Copper rewinding of coil
Set of relays with complete wiring
Cut plate 3 in one
12-0-12 Transformer
Digital Voltmeter
Neon switches
Regulator for manual stabilizer
Providing, fitting of below mentioned item for repairs to up to 10KVA Single Phase Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Replacement of complete coil and core
Copper rewinding of coil
Set of relays with complete wiring
Cut plate 3 in one
12-0-12 Transformer
Digital Voltmeter
Neon switches
Regulator for manual stabilizer
CT type overload relay L&T 400-550
Complete Auxiliary wiring of control panel for single starter unit capacity
10 HP to 50 HP
60 HP to 100 HP
100 HP to 300 HP
Providing, fitting and testing of Push buttons start and stop to FASD Starter
Providing, fitting and testing of Add-On Block to FASD Starter
Providing, fitting and testing of Auxiliary Control Wiring to FASD Starter, Auto Transformer Starter
Providing, fitting and testing of 415Volt Coil/Tripping Coil to Star Delta Starter
Providing, fitting and testing of Contactor Field Coils For ML Series Power Contactor
ML 1.5 380V Ac to 415V Ac
ML-2W 380V Ac to 415V Ac
ML-3W 380VAc To 415V Ac
ML-4W 380V Ac to 415V Ac
ML-6 380V Ac To 415 v Ac
ML-10 380V Ac To 415 V Ac
ML-12 380V Ac To 415 V Ac
Providing, fitting and testing of Contactor Field Coils For ML Series Power Contactor
Providing, fitting and testing of Contactor Field Coils For AC3-LC1F Power Contactor.
Ac3-25A 220V AC To 240 V Ac
Ac3-25A 380V AC To 415 V Ac
Ac3-32A 220V AC To 240 V Ac
Ac3-32A 380V AC To 415 V Ac
Ac3-40A 220V AC To 240 V Ac
Ac3-40A 380V AC To 415 V Ac
Ac3-50A 220V AC To 240 V Ac
Ac3-50A 380V AC To 415 V Ac
Ac3 60A 220V AC To 240 V Ac
Ac3-60A 380V AC To 415 V Ac
Ac3-63A 220V AC To 240 V Ac
Ac3-63A 380V AC To 415 V Ac
Ac3-70A 220V AC To 240 V Ac
Ac3-70A 380V AC To 415 V Ac
Ac3-80A 220V AC To 240 V Ac
Ac3-80A 380VAC To 415 V Ac
Ac3-100A 220V AC To 240V Ac
Ac3-100A 380V Ac To 415 V Ac
Ac3-110A 220V AC To 240 V Ac
Ac3-110A 380V AC To 415 V Ac
Ac3-115A 220V Ac to 240 V Ac
Ac3-115A 380V Ac To 415 V Ac.
Ac3-125A 220V Ac To 240 VAc
Ac3-125A 380V Ac To 415 VAc
Ac3-150A 220V Ac To 240V Ac
Ac3-150A 380V Ac To 415 V Ac.
Ac3-185A 220V Ac To 240 V Ac
Ac3-185A 380 V Ac To 415 V Ac
Ac3-200A 220V Ac To 240V Ac
Ac3-200A 380V Ac To 415 V Ac
Ac3-250A 220V Ac To 240V Ac
Ac3-250A 380V Ac To 415 V Ac
Ac3-265A 220 V ac to 240V Ac
Ac3-265A 380V Ac to 415V Ac
Ac3-350A 220V Ac To 240V Ac
Ac3-350A 380V Ac to 415 v Ac
Ac3-400A 220 V Ac to 240 V Ac
Ac3-400A 380V Ac to 415 V Ac
Ac3-500A 220V Ac To 240V Ac
Ac3-500A 380V Ac To 415 V Ac
AC3-550A 220V Ac To 240 V ac
Ac3-550A 380V Ac To 415 V Ac
Providing, fitting and testing of Contactor Field Coils for MNX Series Power Contactor.
MNX-32A 220V Ac To 240V Ac 50Hz
MNX-32A 380V Ac To 415 V Ac 50Hz
MNX-40A 220V Ac To 240V Ac 50Hz
MNX-40A 380V Ac To 415 V Ac 50Hz
MNX-50A 220V Ac To 240V Ac 50Hz
MNX-50A 380V Ac To 415 V Ac 50Hz
MNX-60A 220V Ac To 240V Ac 50Hz
MNX-60A 380V Ac To 415 V Ac 50Hz
MNX-63A 220V Ac To 240V Ac 50Hz
MNX-63A 380V Ac To 415V Ac 50Hz
MNX-70A 220V Ac to 240 V Ac 50Hz
MNX-70A 380V Ac To 415 V Ac 50Hz
MNX-80A 220V Ac To 240V Ac 50Hz
MNX-80A 380V Ac To 415V Ac 50Hz
MNX-100A 220V Ac To 240V Ac 50Hz
MNX-100A 380V Ac To 415V Ac 50Hz
MNX-110A 220V Ac To 240V Ac 50Hz
MNX-110A 380V Ac To 415V Ac 50Hz
MNX-115A 220V Ac To 240V Ac 50Hz
MNX-115A 380V Ac To 415 V Ac 50Hz
MNX-125A 220V Ac To 240V Ac 50Hz
MNX-125A 380V Ac To 415V Ac 50Hz
MNX-130A 220V Ac To 240V Ac 50Hz
MNX-130A 380V Ac To 415 V Ac 50Hz
MNX-150A 220V Ac To 240V Ac 50Hz
MNX-150A 380V Ac To 415 V Ac 50Hz
MNX-185A 220V Ac To 240V Ac 50Hz
MNX-185A 380V Ac To 415V Ac 50Hz
MNX-200A 220V Ac To 240V Ac 50Hz
MNX-200A 380V Ac To 415V Ac 50Hz
MNX-250A 220V Ac To 240V Ac 50 Hz
MNX-250A 380 V Ac To 415 V Ac 50 Hz
MNX-265A 220V Ac To 240V Ac 50Hz
MNX-265A 380V Ac To 415V Ac 50Hz
MNX-350A 220 V Ac To 240V Ac 50Hz
MNX-350A 380V Ac To 415 V Ac 50 Hz
MNX-400A 110 V Ac 50 Hz
MNX-400A 220 V Ac To 240 V Ac 50 Hz
MNX-400A 380v Ac To 415V Ac 50 Hz
MNX-500A 220V Ac To 240V Ac 50
MNX-500A 380V Ac To 415V Ac 50Hz
MNX-550A 220V Ac To 240 V Ac 50 hz
MNX-550A 380V Ac To 415V Ac 50 hz
Providing, fitting and testing of MNX Series Power Contactor.
Providing, fitting and testing of Contact Points sets for Ac3 Power Contactors.
Providing, fitting and testing of Contact points to MNX Contactors.
Providing, fitting and testing of Over-Load Relay to MU-G Starters.
MU-G 10Hp
MU-G 20Hp
MU-G 30Hp
MU-G 50Hp
Mu-G 75Hp
MU-G 100Hp
Providing, fitting and testing of Controller/Timer
MU-G 10Hp
MU-G 20Hp
MU-G 30Hp
Mu-G 50Hp
MU-G 75Hp
MU-G 100Hp
M/s SAJID ENGINEERING WORKS
M/S ADIL ENGINEERING WORKS
M/S AHANGER ENGINEERING WORKS
M/S EURO LIGHT ENTERPRISES
NEW AHANGER ENGINEERING WORKS
M/S JAY DEE ENTERPRISES
M/S M A ELECTRONICS
M/s Sana Electrical Engineering Works Sopore
M/S FANCY ELECTRIC AND STEEL FABRICATORS
M/s SAJID ENGINEERING WORKS
M/S FANCY ELECTRIC AND STEEL FABRICATORS
M/S ADIL ENGINEERING WORKS
NEW AHANGER ENGINEERING WORKS
M/S EURO LIGHT ENTERPRISES
M/S AHANGER ENGINEERING WORKS
M/S JAY DEE ENTERPRISES
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .