The Admiral Superintendent (for MYP) Naval Dockyard Visakhapatnam 530014
E tender for AMC for 02 in nos.1200KW and 01 in no. 1520KW Mobile Mounted Battery Charger Cum Rectifiers for NDV
2022_NAVY_518812_1
RPYP/AMC/19-20/224(A)
Open Tender
Miscellaneous Services
Supply
365 days
Naval Dockyard at Visakhapatnam
Pre bid meeting on dated 28 Apr 22 at 1030Hrs in MYU department at NDV. Contact details.0891-2816444
4 documents required · 4 mandatory
₹0
Exempted
MYU department at NDV
4 Jul 2022
19 Apr 2022
16 May 2022
19 Apr 2022
14 May 2022
29 Apr 2022
28 Apr 2022
Laying and Jointing PVC Pipe. Heading
AMC for 02 in Nos. 1200KW mobile trailer mounted battery charger cum rectifiers for MYU department at ND(V) for a period of one year as per scope of work placed at Encl 1 to Part II of RFP
AMC for 01 in No. 1520 KW mobile trailer mounted battery charger cum rectifiers for MYU department at ND(V) for a period of one year as per scope of work placed at Encl 1 to Part II of RFP
List of mandatory spares for 1200KW mobile battery charger cum rectifier, Make: statcon (T-4) SCR Capsule 1800A, 1600V (N-600CH15-1403)
Semiconductor Fuse, Fuse Link 800A/690V, Semiconductor Type (Ferraz)
Filter Capacitor, PG CAP.4700MF/450V (Alcon)
Filter Fuse, 63A/63A TIA (Bussmann)
U/V Release Coil Fuse, Fuse Link 4A/32A, NS Type (Bussmann)
Sync. Fuse, Card SPCL 458 (0.5A)(Statcon)
RFI Capacitor, Card RFI-02( 0.1MFD/2KV X2) (Statcon)
Snubber Capacitor, Card SNB-01 0.47MFD/2KV (Statcon)
Accessory Fuse Link, 25A/32A TIA HRC (Bussman)
Service Socket, 6A/5 Pin, Socket + Switch
Space Heater, 230V AC, 1000W Strip (24’’)
Space Heater, 230V AC, 500W Strip (24’’)
Thermostat 300 C – 1100 C (ANCO)
Mains “On”,DC ‘’ON’’ Lamp (R -Y-B Phases),230V AC, Type LED 22.5 MM, colours Red, Blue, Yellow, green (Vaishno)
Main “On” Lamp Bleeder, Card SPCL422 (Drop Resistance Card for Mains indication) 3K3/2WX3
Lamp snubber or Lamp Bleeder DC On Battery OK Reverse Card SPCL 422 (22K/2Wx4)
Diode Card, Card SPCL 422 (4007x4) Statcon
Amplifier Card, Card SPCL-434 (STATCON)
Control Supply MCB 10A, 415V AC TP, Make:ABB
Control Supply MCB 16A, 415V AC TP, Make:ABB
Device Cooling Fan, Fan 220V, AC 6 In (A2175-HBL), 3 Pin CNG Male / Female (SUNON)
SPP Interface Card, Card SPCL-173 (Statcon)
Power Supply Card, Card SPCL-148V3 (220V/12DC)
Power Supply Card, Card SPCL-148V3 (400V:0-12VDC)
Accept Push button P.B 22.4MM, Colours Green, yellow, red, Make: Teknic/vaishno
Alarm Hooter, 12VDC, 96x96
Temperature Sensor , Thermal protector, type:7M, tripping Temp:110+5degC
Control Transformer, 415/230V, 500VA
Lamp Switch, Toggle Switch, 6A, On/Off (Gilard)
PTX Card SPCL 263V1
Reverse Battery Protection Diode, Bridge Diode 35A,/1000V (MIC MB3510 296)
Lamp Push Buttons, 13MM 2C/O, (Vaishno)
Blower Fail Limit Switch, Limit Switch (BCH PSSIL-L)
Firing pulse belt cable
Main Control Card, SPCL 441V2 (Statcon)
Heat shinks for SCRs
List of mandatory spares for 1200KW mobile battery charger cum rectifier, make: Rachyem (T-8) Semi conductor Bushmann Fuses, 0-1600A/ 1000VAC
Voltage transducer LEM VDC
Large axial fan 3 phase 3 wire 415VAC , Model No. 4D-450 size 18”, current 0.6A, 5200M3/HR Make: HICOOL
Snubber card (R-C card)
SCR for Stacks
firing pulse card
Potentiometer, 2KOhm, 1W, 10turn, Type: Servo
Servo Potentiometer, 2KOhm, 1W, 1turn, Type: Servo
18 Channel Annunciator window Minilec AN1
VMR D2 AC under/over voltage relay Single phase prevention
thermo Temperature sensor
Emergency Stop button
Trans 3 Meter card 0-600V to 0-10V
Trans 1 feed back 0-75mV to 0-20mA
Trans 2 feed back 0-75mV to 0-20mA
Trans 4 Meter card 0-600V to 0-20mA
Power supply Control card SMPS CM2 +12, +5V
Power supply Control card SMPS1 24V DC
Power supply Control card SMPS 230VAC/ 15 &-15VDC
List of mandatory spares for 1520kw mobile battery charger cum rectifier, Make: statcon (T-7) SCR Capsule 1800A, 1600V (N-600CH15-1403)
Semiconductor Fuse, Fuse Link 800A/690V, Semiconductor Type (Ferraz)
Filter Capacitor, PG CAP.4700MF/450V (Alcon)
Filter Fuse, 63A/63A TIA (Bussmann)
U/V Release Coil Fuse, Fuse Link 4A/32A, NS Type (Bussmann)
Sync. Fuse, Card SPCL 458 (0.5A)(Statcon)
RFI Capacitor, Card RFI-02( 0.1MFD/2KV X2) (Statcon)
Snubber Capacitor, Card SNB-01 0.47MFD/2KV (Statcon)
AC Contactor, AC Contactor 25A, 220V AC (A09-30-10) ABB
Toggle Switch, 6A, 1P, ON-OFF (Gilard)
AC Voltmeter, Digital Meter 0-500V AC, 96 x 96, CL 1.0 (Aux. 86-270V AC/DC)(ESSEN)
Bleeder Resistance, W/W/R 20E/750W (STEAD)
Snubber Resistance, W/W/R 16E/120W With Clamp (STEAD)
Battery Reverse Contactor, DC Contactor 25A, TP, 220V DC, 250-500V+AUX 3NC (AF-09-30-10) ABB
DC Voltage Resistance Card, Card SPCL236 (220V Drop Ress. Card) Statcon
DC Over Voltage Drop Resistance Card (380V DC), SPCL236 (3K9/2W x 6 Nos) (Statcon)
Feeder Back Card (220V DC), SPCL 236 (15K/2W x 2 Nos + 22K/2Wx4 Nos)
Feedback Card SPCL236 (380V DC Feed Back Card) Statcon
Control Supply MCB 10A, 415V AC TP, Make:ABB
Control Supply MCB 16A, 415V AC TP, Make:ABB
Device Cooling Fan, Fan 220V, AC 6 In (A2175-HBL), 3 Pin CNG Male / Female (SUNON)
SPP Interface Card, Card SPCL-173 (Statcon)
Power Supply Card, Card SPCL-148V3 (220V/12DC)
Power Supply Card, Card SPCL-148V3 (400V:0-12VDC)
Accept Push button P.B 22.4MM, Colours Green, yellow, red, Make: Teknic/vaishno
Alarm Hooter, 12VDC, 96x96
Temperature Sensor , Thermal protector, type:7M, tripping Temp:110+5degC
DC Under Voltage Trip Bypass, Toggle 6A, 2P, 2W
Emergency Stop Push Button, Mushroom Type (22.5 mm NC) (VASHNO)
Annunciation Facia, 24V DC, 8 Windows (MINILEC)
AC U/V Coil (E3N2500MDOPR121) For Input ACB, ACB 2500A/3 Pole/MDO + 230V
230VAC U/V Coil For Output ACB, ACB 2000A/4 Pole 400V (ISDA064631R1) (E3N2000 PR122DC AC MDO
Blower MPCB,19-25A, 3P with Aux. (GPS1BSAP, GE)
Temperature Meter Digital, 0-3000 C, M96, Aux. 230V AC with 8 Mt Probe (Selec)(PT100)
Voltage/Current Set Pot, Fine, 1K, 4 Ganged, 3W (Potel)
Voltage/Current Set Pot Course, 10K, 4 Ganged, 3W (Potel)
Relay 12V, 4C/O, 5A,Type: Plug, (OMRON)
AC/DC U/V, O/V, C/L Relay , Relay MY4N, 4C/O, 24V DC Plug-in Type
UVR Fuse Link, Fuse Link 4A NS Type (Bussman)
UVR Fuses with Base 32A, NS Type (Bussman)
Heater Fuse Link, Fuse Link 20A/20A NS (Bussman)
AC Voltmeter Fuse, Fuse Link 2A NS Type (Bussman)
Control Fuse, Fuse Link 6A, NS Type (Bussman)
DC U/V Drop Card, SPCL-236 Drop Card(2K2/2WX5Nos)
Single Phase Card, SPCL-129V3 Card
AC UV/OV Card
Rectifier Fuse Fail, Card SPCL 139V1-A (Statcon)
Main Control Card, SPCL 441V2 (Statcon)
Anticipatory sapres list of anticipatory spares for 1200kw mobile battery charger cum rectifier, Make: statcon (T-4) Output Current Shunt 3500A/75mV
Output Current Shunt, 800A/75MV (Nikita)
1HP/1440 RPM Motor with impeller blades, Fan Tube Axial of Capacity 4000 M3/HR, 500mm
Trolley Wheels (7.50x15-32) omega wide wall, Recap dam with bearing inner and outer cover side
Blocking Diode , Blocking Diode 1400A/1600V (R1 400E16C)
AC Ammeter, Digital 0-3000/5A, AC, M96, CL1.0, 4.5D, Aux-86-270V AC (MECO)
DC Ammeter, Digital 0-3500A/75MV, DC, M96, CL, 1.0, 4.5D, Aux-86-270V DC/DC Meco
AH Meter, Digital 0-9999AH, ,M96, 230V AC) Model:800ah (COUNTRON)
PF meter, Analog, single coil, M96, CL-1.5 (Rishabh)
Input Current CT 3000/5A, CL -1.0, 15VA, AE
Repair/ replacement of Main Step down transformer Delta /Delta,rating:490KVA
Repair/ replacement of Main Step down transformer Delta /Star, rating:490KVA
Repair/ replacement of IPT -1500A
Repair/ replacement of Choke -1500A
Input ACB 3500A/3 Pole/415VAC with 2NO+2NC with shunt, over current, earth fault, with motorized operated mechanism
Output ACB 2000A/4 Pole/380VDC with 2NO+2NC with shunt, over current, earth fault, with motorized operated mechanism
Repair/ replacement entire thyristor bridge unit set (06 SCRs, 02 firing cards, 02 fuse fail cards, 06 Nos Snubber cards and other fasteners and cables)
LIST OF ANTICIPATORY SPARES FOR 1200KW MOBILE BATTERY CHARGER CUM RECTIFIER, MAKE: Rachyem (T-8) Digital AC Voltmeter 0-500V, Size:96X96mm
Digital AC Ammeter 0-3000A, Size:96X96mm,
Digital DC Voltmeter 0-500V, Size:96X96mm,
Digital DC Ammeter 0-3500A, Size:96X96mm,
Digital Display unit
Trailer wheel with bearing set
Main control card DSP CM 1 with loaded program
Relay Card CM5
Input ACB 3500A/3 Pole/415VAC 2NO+2NC shunt, over current, earth fault, with motorized operated mechanism
Output ACB 2000A/4 Pole/380VDC 2NO+2NC shunt, over current, earth fault, with motorized operated mechanism
Repair/ replacement of Main Step down transformer Delta /Delta,rating:490KVA
Repair/ replacement of Main Step down transformer Delta /Star,rating:490KVA
Repair/ replacement of IPT -1500A
Repair/ replacement of Choke -1500A
Repair/ replacement entire thyristor bridge stack set (06 SCRs, 02 firing cards, 02 fuse fail cards, 06 Nos Snubber cards and other fasteners and cables)
LIST OF ANTICIPATORY SPARES FOR 1520KW MOBILE BATTERY CHARGER CUM RECTIFIER, MAKE: Statcon (T-7) Output Current Shunt 4500A/75mV
Output Current Shunt, 1100A/75MV (Nikita)
Panel Cooling Fan with impeller blades, Fan Tube Axial of Capacity 4000 M3/HR, 500mm with 1HP/1440 RPM Motor (Duly painted and flanged connection) (Astha)
Trolley Wheels (7.50x15-32) omega wide wall, Recap dam with bearing inner and outer cover side
Blocking Diode , Blocking Diode 1400A/1600V (R1 400E16C)
AC Ammeter, Digital 0-3000/5A, AC, M96, CL1.0, 4.5D, Aux-86-270V AC (MECO)
DC Ammeter, Digital 0-4500A/75MV, DC, M96, CL, 1.0, 4.5D, Aux-86-270V DC/DC Meco
AH Meter, Digital 0-9999AH, ,M96, 230V AC) Model:800ah (COUNTRON)
PF meter, Analog, single coil, M96, CL-1.5 (Rishabh)
Input Current CT 3000/5A, CL -1.0, 15VA, AE
Repair/ replacement of Main Step down transformer Delta /Delta, rating:490KVA
Repair/ replacement of Main Step down transformer Delta /Star, rating:490KVA
Repair/ replacement of IPT -2000A
Repair/ replacement of Choke -2000A
Input ACB 3200A/3 Pole/415VAC with 2NO+2NC with shunt, over current, earth fault, with motorized operated mechanism
Output ACB 2500A/4 Pole/380VDC with 2NO+2NC with shunt, over current, earth fault, with motorized operated mechanism
Repair/ replacement entire thyristor bridge unit set (06 SCRs, 02 firing cards, 02 fuse fail cards, 06 Nos Snubber cards and other fasteners and cables)
statcon energiaa pvt ltd
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .