Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 LAccepted-AOC SHOP NO 04 KRISHNA COMPLEX BEHIND UMA COMPLEX MADHAPAR HIGHWAY OPP BANK OF BARODA BHUJ KUTCH GJ 370002 | BHUJ | KUTCH | GUJARAT | 370002 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹3.8 L+₹12,549.71 (3.40%)Rejected-Finance GEETA COTTAGE NO 03 HOUSE NO 11 OPP CIVIL AIR PORT BHUJ KUTCH 370001 GUJARAT | KACHCHH | GUJARAT | 370001 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹4.0 L+₹28,326.71 (7.68%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹4.2 L+₹51,020.71 (13.8%)Rejected-Finance SHOP NO 02 DADA COMPLEX NEAR DENA BANK NALIYA TAL ABDASA KUTCH GUJRAT 370 655 | KACHCHH | GUJARAT | 370655 | L4 | Rejected-Finance Being L4 |
| Sl No | Description | Qty | Unit | AARTI ENTERPRISES L2 | NEELKANTHA ASSOCIATE L4 | GUDDI ENTERPRISE L1 | MAA PUNAGRI ENTERPRISE L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out hard and dense soil complete all as specified and directed. | 48 | CUBIC METRE | 250 ₹12,000 Lowest | 300 ₹14,400 | 383.7 ₹18,417.6 | 350 ₹16,800 |
| 2.00 | M&L for dry sand filling in cable trenches for protection of cables with two layers(ie. 8mm and 15mm thick) below and above cable and punned down to speicified thickness complete all as specified and as directed.
Note: Punned down thickness shall only be measured for payment. | 14 | CUBIC METRE | 2,500 ₹35,000 | 3,000 ₹42,000 | 1,974.9 ₹27,648.6 | 1,200 ₹16,800 Lowest |
| 3.00 | Returning, filling in, including spreading, levelling watering and well ramming in layers n.exc 25cm in Soft/loose soil complete all as specified and directed. | 29.2 | CUBIC METRE | 60 ₹1,752 Lowest | 75 ₹2,190 | 139.1 ₹4,061.72 | 100 ₹2,920 |
| 4.00 | Removing excavated material (soils) distance n.exc 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. | 18.8 | CUBIC METRE | 325 ₹6,110 | 410 ₹7,708 | 320.4 ₹6,023.52 | 100 ₹1,880 Lowest |
| 5.00 | Supplying & laying factory made unreinforced Precast concrete cover of class LV, type 1, flat, size 250 mm x 150 mm x40mm for protection for cable all as specified. | 800 | Each | 55 ₹44,000 | 60 ₹48,000 | 44.2 ₹35,360 | 30 ₹24,000 Lowest |
| 6.00 | Supply and laying of GI tubing light grade for cable protection of size 40 mm dia complete all as specified and directed. | 9 | RUNNING METRE | 420 ₹3,780 | 450 ₹4,050 | 427.2 ₹3,844.8 | 350 ₹3,150 Lowest |
| 7.00 | Supply, laying & testing of XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables(heavy duty) with stranded aluminium conductor, 1100 volts, grade cross setional area 50 sq mm, 4 core complete all as specified and as directed. | 152 | RUNNING METRE | 215 ₹32,680 Lowest | 230 ₹34,960 | 337.52 ₹51,303.04 | 525 ₹79,800 |
| 8.00 | Material and labour for earthing complete with galvanized earth plate electrode in 60 cm x 60 cmx 6 mm thick buried directly in ground vertically at a depth not less than 2.25 meter below ground level with top edge of earth plate at depth not less than 1.5 mtr below ground level connecting to and including GI wire 4.00 mm dia mm by means of GI bolts, nuts, check nuts and washer light grade, 15 mm dia GI protection pipe and connected to equipment, GI pipe medium grade 20 mm dia for watering and including funnel wire mesh, RCC pit cover and PCC 1:3:6 type C-2 including Rocksalt, charcoal, excavation and earth work disposal of surplus soil shown as plate No 3 of SSR Part - I 2009 and all as specified complete.
Note : The unit rate quoted shall deemed to have included for GI protection pipe, GI earth wire up to 7.5 mtr, GI water pipe, wire mesh , funnel , excavation, RCC pit cover complete. | 1 | Each | 7,400 ₹7,400 | 7,500 ₹7,500 | 6,688.4 ₹6,688.4 Lowest | 7,500 ₹7,500 |
| 9.00 | Supply, laying & testing of XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables(heavy duty) with stranded aluminium conductor, 1100 volts, grade cross setional area 10 sq mm, 4 core complete all as specified and as directed. | 72 | RUNNING METRE | 200 ₹14,400 | 230 ₹16,560 | 196 ₹14,112 Lowest | 250 ₹18,000 |
| 10.00 | Material and labour for Industrial plug and socket panel with 32A MCB, 3 phase complete all as specified and as directed. | 2 | Each | 3,500 ₹7,000 | 3,600 ₹7,200 | 2,800 ₹5,600 | 1,400 ₹2,800 Lowest |
Tender Value
₹3.7 L
EMD Value
₹7,350
Closing Date
28 Mar 2026, 6:00 pmClosed
GE (I) (CG) Gandhinagar
GE (I) (CG) Gandhinagar, G-252, Sector-09, Gandhinagar-382007
PROVN OF 03 PHASE POWER SUPPLY TO CERTAIN KITCHEN EQUIPMENT AND PROVN OF STANDBY CENTRALISED RO PLANT AT ICGS JAKHAU UNDER GE (I) (CG) GANDHINAGAR
2025_MES_743548_2
8169/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
ICGS Jakhau
As per NIT
7 documents required · 7 mandatory
₹500
GE (I) CG Gandhinagar
₹7,350
Yes
18 Jun 2026
14 Mar 2026
30 Mar 2026
14 Mar 2026
28 Mar 2026
21 Mar 2026
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out hard and dense soil complete all as specified and directed.
M&L for dry sand filling in cable trenches for protection of cables with two layers(ie. 8mm and 15mm thick) below and above cable and punned down to speicified thickness complete all as specified and as directed. Note: Punned down thickness shall only be measured for payment.
Returning, filling in, including spreading, levelling watering and well ramming in layers n.exc 25cm in Soft/loose soil complete all as specified and directed.
Removing excavated material (soils) distance n.exc 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Supplying & laying factory made unreinforced Precast concrete cover of class LV, type 1, flat, size 250 mm x 150 mm x40mm for protection for cable all as specified.
Supply and laying of GI tubing light grade for cable protection of size 40 mm dia complete all as specified and directed.
Supply, laying & testing of XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables(heavy duty) with stranded aluminium conductor, 1100 volts, grade cross setional area 50 sq mm, 4 core complete all as specified and as directed.
Material and labour for earthing complete with galvanized earth plate electrode in 60 cm x 60 cmx 6 mm thick buried directly in ground vertically at a depth not less than 2.25 meter below ground level with top edge of earth plate at depth not less than 1.5 mtr below ground level connecting to and including GI wire 4.00 mm dia mm by means of GI bolts, nuts, check nuts and washer light grade, 15 mm dia GI protection pipe and connected to equipment, GI pipe medium grade 20 mm dia for watering and including funnel wire mesh, RCC pit cover and PCC 1:3:6 type C-2 including Rocksalt, charcoal, excavation and earth work disposal of surplus soil shown as plate No 3 of SSR Part - I 2009 and all as specified complete. Note : The unit rate quoted shall deemed to have included for GI protection pipe, GI earth wire up to 7.5 mtr, GI water pipe, wire mesh , funnel , excavation, RCC pit cover complete.
Supply, laying & testing of XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables(heavy duty) with stranded aluminium conductor, 1100 volts, grade cross setional area 10 sq mm, 4 core complete all as specified and as directed.
Material and labour for Industrial plug and socket panel with 32A MCB, 3 phase complete all as specified and as directed.
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker(MCB) of four poles and current carrying capacity TPN 40 to 100 AMP in the DB complete with connection testing and commissioning all as specified and as directed.
Supply and fixing sheet metal enclosure for single door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted TP & N 8 ways, 415volts, ISI marked, 200 Amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed.
Supply, install, commission and testing of RO plant system of capacity 500Ltr per hour with equipment like dual media filter, antiscalant dosing, micron filtration unit, osmotic pressure vessel with modules, conductivity meter, rotameter, pre filter pump, high pressure pump, pressure gauge, control pannel, senser, UPVC pipe lines etc complete including starter panel, cable all as specified and directed. Note: TDS for RO Water should be less than 150PPM, Antiscalant 100Ltrs provided with the plant, minor spares required at siite deemed to be included in quoted rates. Make: Thermax limited, Optimus enviro Pvt Ltd or Jeel aqua.
Material and labour for screwing existing steel/ PVC tubing for alterations or additions of size 50mm (or lengthening screw on pipe to form connector) in position complete all as specified and as directed.
Supply and laying in on wall Unplasticised PVC pipes 25mm bore of pressure rating 10 Kgf/sq cm water tubing, including necessary fittings such as bends,Tees, Union etc complete and connecting to water supply pipe line and connections including removing / taking down the old pipe line complete all as specified and directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
BOQ_847250.xls
BOQ • 0.30 MB
8169ps.pdf
Tender Documents • 1.00 MB
amdt002.pdf
PDF • 0.19 MB
amdt02.pdf
PDF • 0.19 MB
amdt.pdf
PDF • 0.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .