Manager SRC-OS
Hindustan Shipyard Limited Gandhigram SR Complex Visakhapatnam 530 005
ROUTINES ON MAIN SWITCH BOARD, CLAIBRATION OF BEAKERS AND SWITCH BOARD SAFETIES ON INS JAMUNA
2025_HSL_97196_2
20 / 22040 / 057 / SWITCHBOARS/BREAKERS/ 2025-26
Open Limited
Miscellaneous Services
Service
60 days
HSL Visakhapatnam
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
Exempted
12 May 2025
24 Apr 2025
3 May 2025
24 Apr 2025
3 May 2025
24 Apr 2025
Amount
VESSEL : INS JAMUNA WO.NO:22040 DL NOS : DL NO : 30019 SUB:Routines on Main Switch Board, Calibration of Breakers & Switch Board safeties
SWITCH BOARDS, M/s MARINE ELECTRONICS AND NAVI PVT LTD(MAINTOP NO-53000) CARRY OUT FOLLOWING ROUTINES ON SWITCHBOARD AND BUSBARS: (A) INSPECT LUGS/ CONNECTORS/ CT/ PT AND OTHER COMPONENTS AND UNDERTAKE REPAIR DETERIORATION OF DAMAGED COMPONENTS. SERVACIBALITY CHECKS OF MSB CABLES/ WIRING RENEW DAMAGED CABLES. (B) SERVICEABILITY CHECKS OF BUSBAR INSULATORS, RENEW DAMAGED INSULATORS. (C) CLEAN AND DECARBONIZE THE BUSBARS. (D) CARRYOUT FUNCTIONAL CHECKS OF MSB AND PARALLELING TRIALS WITH ALL COMBINATIONS OF GENERATOR SUPPLY.
CARRY OUT IN-SITU SERVICEABILITY CHECKS AND CALIBRATION OF BREAKERS. (I)ACB (800 A) -06
CARRY OUT IN-SITU SERVICEABILITY CHECKS AND CALIBRATION OF BREAKERS. (II)INERCONNECTOR (630 A)- 04
CARRY OUT IN-SITU SERVICEABILITY CHECKS AND CALIBRATION OF BREAKERS. (III)BUS COUPLER(630 A)-05
CARRY OUT IN-SITU SERVICEABILITY CHECKS AND CALIBRATION OF BREAKERS. (IV)SHORE SUPPLY BREAKER (630 A)-02
DA MIMIC PANEL INDICATION: INDICATION LAMPS, WIRING AND DRAWING OF DA MIMIC PANEL PERISHED DUE TO FAIR WEAR AND TEAR. OVERHAULING OF DA MIMIC PANEL FITTED IN DCHQ IS REQUIRED WITH ALL REQUIRED MATERIALS AND CONSUMABLES.
MAIN SWITCHBOARD: VARIOUS COMPONENTS OF MAIN SWITCHBOARD MALFUNCTIONING. REPLACEMENT OF COMPONENTS MENTIONED BELOW IS REQUIRED: - (A) INSULATION MONITOR (T3200) ( INFINITY TO ZERO)
(B) TRANSDUCER (03P-3E-3W) (-40 to +325 KW)
(C)MCCB, 3Pole, 630A, 50KA
(D) MCCB, 250A, 50KA, 3 pole
(E) MCCB ,200A, 36 KA, 3 pole
(F) MCCB , 160A, 36 KA, 3 pole
(G) MCCB , 125A, 36 KA, 3 pole
(H) MCCB, 100A, 18 KA, 3 pole
(J) MCCB ,80A , 18 KA, 3 pole
(K) MCCB , 63A, 18 KA, 3 pole
(L) GENERATOR PROTECTION UNIT
(M) VOLTMETER (0-500VOLT)
(N) AMMETER (0-500AMPS)
(P) KW METER (-40 TO +325)
(Q) SYNCROSCOPE METER
SETTINGS OF THE GPU IS NOT CALIBRATED IN ACCORDANCE WITH ALTERNATOR. CALIBRATION OF GPU IS REQUIRED AND SATISFACTORY TRIALS TO BE OFFERED.
SRI VENKATA SAI CONSTRUCTION (BID ID -416426)
MANIKANTHA ELECTRICAL RE-WINDING WORKS (BID ID -416428)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Restricted Tender
This is a Open Limited tender. Documents are accessible only to bidders authorized by the issuing authority on the government portal.
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .