Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29,505Accepted-Finance | L1 | Accepted-Finance L1 for defect sl L 035 | |
| 2 | L1₹51,975Accepted-Finance MBPT PLOT 58 ANCHOR HOUSE 1ST MAGAZINE CROSS STREET DARUKHANA MUMBAI MAHARASHTRA 400010 | MUMBAI SUBURBAN | MAHARASHTRA | 400010 | L1 | Accepted-Finance L1 for Defect sl L 029 | |
| 3 | L1₹63,735Accepted-Finance | L1 | Accepted-Finance L1 for defect sl. L 032 L034 H 231 | |
| 4 | L1₹76,860Accepted-Finance | L1 | Accepted-Finance L1 for defect sl H 040 E 017 | |
| 5 | L1₹2.5 LAccepted-Finance | L1 | Accepted-Finance L1 for Defect Sl L 030 L 031 E 032 H 049 E 018 L 027 and E 045 |
Tender Value
Refer Docs
Closing Date
23 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Commandant B Sabarish
CGDHQ-1, PORBANDAR
DEFECT RECTIFICATION ON VARIOUS DEFECTS ONBOARD ICGS C-161, C-156, ACV H-198 AND C-445
2022_ICG_537955_1
344/C-161/C-156/ACV H-198/C-445/22-23
Limited
Miscellaneous Services
Turn-key
90 days
CGDHQ-1
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
26 Jul 2022
15 Jul 2022
25 Jul 2022
15 Jul 2022
23 Jul 2022
15 Jul 2022
L-029: Anemometer (Make : Furuno, Model : RD-33) true wind speed data are not showing in display. Suspect wind sensor defective. Defect to be rectified and proved for optimum performance. (ICGS C-161)
H-040: Wooden flooring of Captain’s Cabin deteriorated. Needs to be fabricated. Area 7.5 feet x 3.5 feet. Mat – Marine plywood/Wood. (ICGS C-161)
L-030: Lub oil pump is not working view motor showing low insulation. Defect rectification to be carried out for the same and system to be proved for satisfactory operation. (ICGS C-161)
L-031: Window wiper no. 01 is not working view defective motor. Defect rectification to be carried out for the same and system to be proved for satisfactory operation. (ICGS C-161)
L-032: 01 in no. Fan in SO’s cabin (Make: Havells, Swing) is not getting switch “ON”. However, power supply is available at PSU unit. DI/DR to be carried out and equipment to be proved for satisfactory operation. (ICGS C-161)
E-032 :AC plant No. 2 (Make: Carlyle, Type: 6DA 537) not giving desired cooling effect. During DI/DR found piston ring worn out. Plant to be overhauled and system to be proved for optimum performance. (ICGS C-161)
L-034 : 01 in no. Fan in dinning hall cum office (Make: Havells, Swing) is not getting switch “ON”. However, power supply is available at motor unit. DI/DR to be carried out and equipment to be proved for satisfactory operation. (ICGS C-161)
L-035 : Abnormal noise and overheating observed on AHU motor (415 V AC, 3 phase, 50 Hz, Capacity: 2.2kW) during operation of AC, power supply cable deteriorated v open circuit. Cable to be renewed as per cable schedule and to be proved for satisfactory operation. (Length : 14 Mtrs, Size: 3 x 1.5 sq mm & Type : MPRX) (ICGS C-161)
H-049 : One in no. 12.7 MM HMG cradle elevation/ depression handle teeth worn out due to non operational of over lapping handle. Same to be repaired as per sample. Mat : MS. (ICGS C-161)
H-231 : Canvas covers of superstructure, life fan bay, engine room and cockpit of ACV H-198 worn out. Canvas cover to be renewed as per sample 32 in nos. eyelets of crimped stainless steel rings to be provided at all sides for lashing with ropes (Mat : PVC coated canvas) (a) Superstructure, size approx. Length- 10 mtrs, Breadth- mtrs (b) Lift fan bay, size approx. Length-3 mtrs, Breadth-5 mtrs (c) Engine room, size approx. Length-5 mtrs, Breadth-5 mtrs (d) Cockpit, size approx. Length-2.5 mtrs, Breadth-5 mtrs (ACV H-198)
E-017 : Both AC plant tripped due to low Ref pressure indication. Suspect AC gas leakage from system. Defect to be rectified and proved for satisfactory operation. (ICGS C-156)
E-018 : Abnormal sound observed in AC condenser pump. Suspect mechanical seal damage. Defect to be rectified and proved for satisfactory performance. (ICGS C-156)
L-027: Port main engine and DA battery charger (Make: Marine Electricals) is not working. Suspect flatpack2 unit (SMPS) malfunctioning. The defect to be rectified and proved for satisfactory operation. (ICGS C-156)
E-045 : Exhaust gas leakage observed from port main engine exhaust due to bellow crack. New bellow to be fabricated as per sample. Inway job includes re-fitment of exhaust bellow with gasket on both end alongwith lagging (Approx area of 05 sq mtr). System to be proved for satisfactory function. (ICGS C-445)
Chamunda Fabrication
VYAS AND SONS ENTERPRISE
A S Moloobhoy Pvt Ltd
VARUN INFOTECH
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
finance_601287.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .