EE,NORTH 24 PARGANAS ELECTRICAL DIVISION,PWDte.
OFFICE OF THE EXECUTIVE ENGINEER NORTH 24 PARGANAS ELECTRICAL DIVISION, TOP FLOOR, MECHANICAL COMPLEX,BAGUIATI, KOLKATA 700 059.
Repair and Renovation of Compound lights Installation works for illumination of entire area insite of Bhatpara State Genaral Hospital under Barrackpore Electrical Sub Division, P.W.Dte.
2026_WBPWD_5079845_1
WBPWD/EE/N24/EL/e-NIQ- 78/26-27
Open Tender
ELECTRICAL WORKS ORG
Item Rate
7 days
Barrackpore
Please refer Tender documents.
4 documents required · 4 mandatory
₹16,870
15 Oct 2026
15 Oct 2026
27 Oct 2026
15 Oct 2026
23 Oct 2026
15 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying of 1.1 KV grade, XLPE/PVC Insulated, 2 core 10 sq. mm Al. armoured cable. (Make- RR/Mescab/Havells) | 675 | RM | 1 | ₹675 |
| 2 | Supplying & fixing 25 mm dia medium gauge GI Pipe ( ISI-Medium)Protection with necessary fittings and jointing metarials as required | 70 | RM | 2 | ₹140 |
| 3 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm | 70 | RM | 3 | ₹210 |
| 4 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm | 500 | RM | 4 | ₹2,000 |
| 5 | Laying and fixing of one number PVC insulated and
PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) | 105 | RM | 5 | ₹525 |
| 6 | Supplying and making end termination with brass
compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required. 2 X 10 sq. mm (19mm) | 36 | Each | 6 | ₹216 |
| 7 | 90 watt LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP 66,IK-10, CRI >70, under voltage and over voltage protection, EMI- EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall besubmitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | 22 | Each | 7 | ₹154 |
| 8 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 6.5 Meter and upto 8.0 Meter | 18 | Each | 8 | ₹144 |
| 9 | Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint. | 18 | Set | 9 | ₹162 |
| 10 | Supplying & fixing of 240 V time sensor switch consisting of the following accessories: A) 240 V, 40 A, DP MCB isolator of breaking capacity 10 KA & C characteristics - 01 no. (Make: L & T), B) 24 hour digital timer switch (Make: L & T) - 01 no., C) 240 V, 40 A, DP power contactor (Make: L & T) - 01 no., D) Auto manual toggle switch - 01 no., E) 240 V, 32 A, SP MCB of breaking capacity 10 KA & C characteristics (Make: L & T) - 01 no., F) LED indicator lamp - 01 no. red & 01 no. green in 2+10 way SPN MCB DB (Make: L & T, Enclosure: LTSD12N) incl. lock & key arrangement concealed in wall after cutting the wall & mending good the damages to original finish incl. interconnection with suitable size of Cu wire & provision for earthing attachment. (For outdoor light control) | 1 | Set | 10 | ₹10 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.65 MB
2911.pdf
Tender Documents • 0.43 MB
BOQ_5184711.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .