EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX RAJ BAGH
Development of Hazrat Baba Shukur ud Din RA at Watlab Sopore Baramulla by way of Electric work.
2026_PWDJK_317083_1
NIT No.86//2026-27 Dt/21/07/2026
Open Tender
Electrical Works
Percentage
Watlab Sopore
Please refer Tender documents.
4 documents required · 4 mandatory
₹800
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹39,032
21 Jul 2026
21 Jul 2026
6 Aug 2026
21 Jul 2026
5 Aug 2026
21 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply/errection of 7 Meters long Galvanized Iron octogonal poles poles with base plate size 225 x 225 mm and thickness 12 mm, hole PCD 225 mm with 04 No. of Holes, Hole Dia 24MM/Slotted, Size of Door Opening 250MM, Pole section thickness 3 mm, Bottom Dia (outer) 130 mm and top Dia (outer) 70 mm with single arm of Length 1000 mm, Arm Dia 42 mm, foundation bolt length 600 mm and dia 20 mm capable of bearing wind speed of 180 lm/hr Dimension Tolerance as Per BSEN 40, Material Tolerance as per IS 1852-1985, Shaft material type as per BSEN 10025 S 355 or Equivalent, base plate type as per IS 2062, hot dip galvanized with zinc coating thickness not below 65 Microns, galvanizing type as per ISO 1461:1999 and finishing type as per IS 11759-1985. The material is to be got inspected at the site of manufacturing by concerned SDO and Site Engineer In-Charge for which the expenses will be beared by the firm to whom the contract will be alloted. BPP/ Utkarsh/ Kasper/ Bajaj/ Equivalent make | 34 | No. | 18,000 | ₹6,12,000 |
| 2 | Providing and laying of concerete bottoming with pit size 0.5m x0.5x1.2m (Deep). In 1:1.5.3 (M20 grade) concerete with crusherd querry 15- 20 mm stone aggr. for all poles pit/foudation including t including form works, plastering, coring etc as required. | 34 | Job | 3,500 | ₹1,19,000 |
| 3 | Providing and fixing of MCB - 6 amps,240v, single pole; c-curve characteristic of Havels/Legrands/L&T Make | 34 | No. | 285 | ₹9,690 |
| 4 | Providing and fixing of connectors 60Amps,440v; 2x4 way/slots of Havels/Legrands/L&T Make | 34 | No. | 2,500 | ₹85,000 |
| 5 | SITC high quality integrated 60 watts LED street light with minimum system lumen of 15000lm and sysytem wattage not exceeding 60W with a nominal efficency 115-140 lumen/watt CCT of 5700k with SDCM of <5 and CRI: 70: PF> 0.95, lifetime of 50K hours @L70. The body/housing should be of non-corrosive high- pressure die-cast aluminum to with stand extreme environments . The Ingress rotection should be minimum IP 66 with an lK rating of 08. The Luminaire should have a 10 KV /10 KA SPD duly bolted in the Luminaire . The SPD should be able to sustain a minimuns 15 hits of 10KA raiting i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2 The luminaire should be capable of withstanding voltage stress of 440volt for 8 Hrs., should have an Auto Shutdown @ 325V and have an auto recovery feature. The Drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire.philips/Wipro/Havells/Halonix/Eq Make | 34 | No. | 7,500 | ₹2,55,000 |
| 6 | Supply and laying of DWC HDPE corrrigated pipe ISI Marked along with all accessories like socket,bends,coriplers , joints conforming to IS14930,part II complete with fitting
/cuttings,jointing etc. direct in ground(18 inhes below grounò tevel or as appoved excluding sand cushioning and proteczive cover etc complete asrequired 63 mm dia (OD-63mm & lD-51 mm nominal make approved REX /Duraline-duly ISI marked | 680 | Metre | 285 | ₹1,93,800 |
| 7 | Supply/Laying/Connecting and Commissioning of 16 sq.mm 2-Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havells/Polycab/Eq. Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench .(Material to be approved before execution) | 680 | Meter | 275 | ₹1,87,000 |
| 8 | Supply/Laying/Connecting and Commissioning of 50 sq.mm 2-Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havells/Polycab/Eq. Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench .(Material to be approved before execution) | 100 | Metre | 850 | ₹85,000 |
| 9 | Providing, laying and fixing of 2"dia G.I pipe class A for road/path crossings .surya/Tata/jindal make | 20 | Metre | 300 | ₹6,000 |
| 10 | Providing, and fixing of service wires 2x1.5+1x15 sqmm cu wire 1100V, PVC insulated for light fixure upto pole box, havel/RR/Polycab | 238 | Metre | 267 | ₹63,546 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.50 MB
BOQ_1037405.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].