Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 LAdmitted-Finance JL 103 SUTAHATA SRI KRISHNAPUR HALDIA EAST MEDINIPUR WEST BENGAL 721635 UDYAM WB 10 0002192 19AAACW6033G1ZC B R MSME STATUS AS NOT VERIFIED | MEDINIPUR EAST | WEST BENGAL | 721635 | ₹5.9 L | L1 | Admitted-Finance |
| 2 | L2₹6.4 LAdmitted-Finance 8 9 BENTINCK STREET KOLKATA 700001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | ₹6.4 L | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Techno-Commercially not qualified |
| Sl No | Description | Qty | Unit | R V BRIGGS AND COMPANY PVT LTD L2 | WEST BENGAL WASTE MANAGEMENT LIMITED L1 |
|---|---|---|---|---|---|
| 1.00Rate Contract for Environmental Monitoring | |||||
| 1.01 | Collection of sample for emission
Through stack/ stacks of the operating unit/units(as per availability
irrespective of the date for the particular month)of the power
station conducting analysis and submitting report etc. | 120 | Number | 1,650 ₹2.0 L | 1,193 ₹1.4 L |
| 1.02 | Collection of sample for ambient air
Collection of sample for ambient air From identified location
prevailing at the power station conducting analyzing &submitting
report containing relevant parameters including Pb&Co etc. all as
per guideline/stipulation of MOEF/WBPCB. No of sampling may
be different as per requirement of the
plant. | 72 | Number | 3,100 ₹2.2 L | 2,800 ₹2.0 L |
| 1.03 | Collection of sample of Dry ash Collection of sample of Dryash from Silo, analyzing &submitting
report all as per guideline/stipulation of MOEF/GOI/WBPCB/CEA
showing different parameters e.g geotechnical & engineering
properties, shear properties &Consolidation properties along with
physical &chemical properties. | 2 | Number | 2,700 ₹5,400 | 5,500 ₹11,000 |
| 1.04 | Effluent water sample from two Out fall locations & analyzing & submitting report as per
guideline/stipulation of MOEF/WBPCB. No of sampling maybe
different as per requirement of the plant | 48 | Number | 1,350 ₹64,800 | 1,800 ₹86,400 |
| 1.05 | Monitoring of Noise level at locations
locations not exceeding four(4)in number Analyzing, submitting
report as per Guidelines/stipulation of MOEF/WBPCB | 24 | Number | 400 ₹9,600 | 230 ₹5,520 |
| 1.06 | Collection & conducting analysis of
of Ground water samples during pre Monsoon & post Monsoon
period as may be collected from dug well/bore well/Tube well at
upstream &downstream of existing &proposed ash pond
andaround5km radius of Ash Pond. parameters including, pH,
TSS, Fluride, iron, nickel, arsenic, Hg, Pb, Cu, Zn, Cadmium,
Chromium compounds,sulphateasSO4,Nitrate as NO3. | 4 | Number | 2,550 ₹10,200 | 1,700 ₹6,800 |
| 1.07 | Collection & conducting bacteriological
(Total Coliform, E-Coli, pH, Dissolved
O2,BOD(5Daysat20DegC)Arsenic).Analysis of drinking/portable
water samples collected from plant & Township & submitting
report as per guidelines/stipulation of MOEF/WBPCB. | 16 | Number | 1,200 ₹19,200 | 2,300 ₹36,800 |
| 1.08 | Collection of samples for analysis
analysis Liquid effluent water from Boiler Blow down at out fall
location & submitting report etc. All as per guidelines/stipulation
of MOEF/GOI/WBPCB/CEA .Parameters to be tested are : oil&
grease, cu, Fe& TSS(all in mg/ltr). | 24 | Number | 900 ₹21,600 | 700 ₹16,800 |
| 1.09 | Collection of samples for analysising Liquid effluent water from ash pond &Plant effluents including
canteen and submitting report etc. All as per guidelines/stipulation
of MOEF/GOI/WBPCB/CEA. Parameters to be tested are oil
&grease, pH, TSS(all in mg/ltr),BOD(3Dayat27DegC),COD,
Arsenic | 24 | Number | 900 ₹21,600 | 1,100 ₹26,400 |
Tender Value
₹6.5 L
EMD Value
₹12,929
Closing Date
16 Feb 2026, 4:00 pmClosed
The General Manager STPS
Admin Building, STPS,Purulia,W.B., 723146
Rate Contract for Environmental Monitoring and submission of Statement for 2 X 250 MW STPS of WBPDCL for Two years
2026_WBPDC_993662_1
WBPDCL/STPS/NIT/E4297/25-26
Open Tender
Support/Maintenance Service
730 days
Admin. bldg, STPS, W.B.
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹12,929
Yes
16 Jun 2026
29 Jan 2026
18 Feb 2026
29 Jan 2026
16 Feb 2026
30 Jan 2026
Rate Contract for Environmental Monitoring
Collection of sample for emission Through stack/ stacks of the operating unit/units(as per availability irrespective of the date for the particular month)of the power station conducting analysis and submitting report etc.
Collection of sample for ambient air Collection of sample for ambient air From identified location prevailing at the power station conducting analyzing &submitting report containing relevant parameters including Pb&Co etc. all as per guideline/stipulation of MOEF/WBPCB. No of sampling may be different as per requirement of the plant.
Collection of sample of Dry ash Collection of sample of Dryash from Silo, analyzing &submitting report all as per guideline/stipulation of MOEF/GOI/WBPCB/CEA showing different parameters e.g geotechnical & engineering properties, shear properties &Consolidation properties along with physical &chemical properties.
Effluent water sample from two Out fall locations & analyzing & submitting report as per guideline/stipulation of MOEF/WBPCB. No of sampling maybe different as per requirement of the plant
Monitoring of Noise level at locations locations not exceeding four(4)in number Analyzing, submitting report as per Guidelines/stipulation of MOEF/WBPCB
Collection & conducting analysis of of Ground water samples during pre Monsoon & post Monsoon period as may be collected from dug well/bore well/Tube well at upstream &downstream of existing &proposed ash pond andaround5km radius of Ash Pond. parameters including, pH, TSS, Fluride, iron, nickel, arsenic, Hg, Pb, Cu, Zn, Cadmium, Chromium compounds,sulphateasSO4,Nitrate as NO3.
Collection & conducting bacteriological (Total Coliform, E-Coli, pH, Dissolved O2,BOD(5Daysat20DegC)Arsenic).Analysis of drinking/portable water samples collected from plant & Township & submitting report as per guidelines/stipulation of MOEF/WBPCB.
Collection of samples for analysis analysis Liquid effluent water from Boiler Blow down at out fall location & submitting report etc. All as per guidelines/stipulation of MOEF/GOI/WBPCB/CEA .Parameters to be tested are : oil& grease, cu, Fe& TSS(all in mg/ltr).
Collection of samples for analysising Liquid effluent water from ash pond &Plant effluents including canteen and submitting report etc. All as per guidelines/stipulation of MOEF/GOI/WBPCB/CEA. Parameters to be tested are oil &grease, pH, TSS(all in mg/ltr),BOD(3Dayat27DegC),COD, Arsenic
Collection of samples for analysising From condenser cooling water& submitting report etc. All as per guidelines/stipulation of MOEF/GOI/WBPCB/CEA. Parameters to be tested are pH, Temp, free chlorine.
Collection of samples for analysising analyzing &submitting report etc. All as per guidelines/stipulation of MOEF/GOI/WBPCB/CEA. Parameters to be tested are Free available chlorine, Zinc, Cr, Phosphate.
Collection of samples for fugitive air air For four(4)separate locations, analyzing & submitting report etc. All as per guidelines/stipulation of MOEF/GOI/WBPCB. Parameters to be tested are: PM10,PM2.5,SO2,NO2,O3,NH3,Pb,Benzene,Arsenic,BenzoPyrene,N i,Co.
Preparation of half yearly environment Statement as per guideline of MOEF/GOI/WBPCB comprising all above & necessary particulars.
Collection of sample of Pond ash From Ash pond, analyzing & submitting report all as per guideline/stipulation of MOEF/GOI/WBPCB/CEA showing different parameters e.g geotechnical & engineering properties, shear properties & consolidation properties along with physical & chemical properties.
Collection of water samples from Ash pond for analyzing &submitting report etc. All as per guidelines /stipulation of MOEF /GO I /WBPCB /CEA .Parameters to be tested Zn, Ag, Cd, Hg, Pb, As total, Cr total.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.98 MB
BOQ_2430714.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid