Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC NEHRUGRAM DEHRADUN DISTRICT | ₹1.6 Cr | L1 | Accepted-AOC L1 |
| 2 | Rejected-Technical | - | - | Rejected-Technical Technical Qualification is not Qualified as per NIT |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technical Qualification is not Qualified as per NIT |
| 4 | Rejected-Technical | - | - | Rejected-Technical Technical Qualification is not Qualified as per NIT |
Tender Value
₹1.7 Cr
EMD Value
₹3.3 L
Closing Date
26 Aug 2023, 12:30 pmClosed
S.E R.W.D Circle Pauri
Superintending Engineer Rural Works Department Circle Pauri Tehsil Road Near Gas agency Pauri
CONSTRUCTION OF MAIN BUILDING OF G.I.C. KHANKHARA BLOCK AUGUSTYAMUNI RUDRAPRAYAG
2023_RES_61883_1
746/RWD/T.I-02/2023-24
Open Tender
Civil Works - Buildings
Item Wise
450 days
Rudraprayag
Technical Qualification as per NIT
3 documents required · 3 mandatory
₹5,900
As per attached
₹3.3 L
S.E R.W.D Circle Pauri
26 Sept 2023
11 Aug 2023
26 Aug 2023
11 Aug 2023
26 Aug 2023
11 Aug 2023
21 Aug 2023
Amount
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. in all kind of soil
Filling available excavated earth (excluding rock) in trenches, plinthsides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, leadup to 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - -All work upto plinth level in 1:4:8 (1 Cement : 4 Fine sand : 8 graded stone aggregate 40 mm nominal size).
Providing and laying in position cement concrete of 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level withCement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth inCement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with F.P.S. bricks of class designation 75 in superstructure abov plinth level upto floor V level inCement mortar 1:4 (1 cement :4 coarse sand)
Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry (with F.P.S. bricks).
Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centring and shuttering including strutting,ropping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete.
Centring and shuttering including strutting,ropping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform.
Centring and shuttering including strutting,ropping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Centring and shuttering including strutting,ropping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts.
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Hot rolled twisted bars.
Steel work welded in built up section/framed work including cuttin in position and applying a priming coat of approved steel primer us required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and nuts as required including fixing of necessary butt hinges and screws and applyinFixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 ( 1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 10.30.1 4.0 mm thick glass panes
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:
12 mm cement plaster of mix. 1:6 cement and fine sand mortar.
15 mm cement plaster on rough side of single or half brick wall of mix1: 6 (1 cement: 6 fine sand)
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) decorative type, core of block board construction withframe of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces ofshutters. 9.20.1 35 mm thick including ISI marked Stainless Steel butt hingeswith necessary screws
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete :9.62.2 250x16 mm
9.63 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :9.63.2 200x10 mm
9.66 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 9.66.1 125 mm
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth
Brick edging 7cm wide 11.4cm. deep to plinth protection with bricks of class designation 75 including grouting with cement mortar 1:4 (1 cement : 4 fine sand)
Providing and fixing Ist quality ceramic glazed wall tiles conf IS : 15622 (thickness to be specified by the manufacture ) of appr make in all colours, shades except burgundy, bottle green, black of size as approved by Engineer-in-Charge in skirting, risers of ste dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 c sand) and jointing with grey cement slurry @ 3.3kg per sqm i pointing in white cement mixed with pigment of matching sh complete.
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm with top and bottom rail of T-iron 40x40x6mm with 40mm pulleys complete with bolts, nuts, locking arrangement, stopp handles, including applying a priming coat of approved steel prime
Providing and laying Ceramic glazed floor tiles 300x300 mm (thick to be specified by the manufacturer) of 1st quality conformin 15622 of approved make in colours such as White, Ivory, Grey, conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Ce Coarse sand) including pointing the joints with white cement matching pigment etc., complete.
Finishing walls with Acrylic Smooth exterior paint of required shade :13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqmover and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
13.42 Distempering with 1st quality acrylic distemper (ready mixed)having VOC content less than 50 gms/litre, of approvedmanufacturer, of required shade and colour complete, as permanufacturer’s specification.13.42.1 Two or more coats on new work
13.62 Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :13.62.1 Two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand and manufacture
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 , of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Iinternal work - Exposed on wall15 mm dia. nominal bore
Providing and fixing brass stop cock of approved quality15 mm nominal bore
Concealed pipe with anti corrosive bitumastic paint, cutting chases and making good the wall15 mm dia nominal bore
Providing and fixing ball valve (brass) of approved quality completeHigh or low pressure with plastic floats15 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene w tank ISI : 12701 marked with cover and suitable locking arrangem necessary holes for inlet, outlet and overflow pipes but without fitti base support for tank
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:893115 mm nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15mm nominal bore.
Providing and fixing mirror of superior glass (of approv quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. with plastic moulded frame of approved make and shades with 6 mm thick hard board backing:Rectangular shape 453x357mm
Constructing brick masonry chamber for underground C.I. inspecti and bends with 75 class designation bricks in cement mortar 1:4 ( coarse sand) C.I. cover with frame (light duty) 455x610 mm intern total weight of cover with frame to be not less than 38 kg (weight and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 ceme sand : 4 graded stone aggregate 20 mm nominal size) foundation (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nomin plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coar smooth with a floating coat of neat cement on walls and bed concr complete as per standard design :With F.P.S. bricksInside dimensions 455x610 mm and 45 cm deep for single pipe line :
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mmWhite Vitreous china Orissa pattern W.C. pan of size 580x440mm foot rests.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32White Vitreous China Flat back wash basin size 550x400 mm with brass pillar tap.
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively.
Providing and fixing on wall face unplasticised Rigid PVC rain water conforming to IS : 13592 Type A including jointing with seal ring c 5382 leaving 10 mm gap for thermal expansion, (i) Single sockete75 mm diameter
Providing and fixing on wall face unplasticised Rigid PVC rain water conforming to IS : 13592 Type A including jointing with seal ring c 5382 leaving 10 mm gap for thermal expansion, 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conformingto IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermal expansion. 12.42.1 Coupler 12.42.1.1 75 mm
Providing and fixing on wall face unplasticised - PVC moulded fittin for unplasticised Rigid PVC rain water pipes conforming to IS : 135 including jointing with seal ring conforming to IS : 5382 leaving 10 thermal expansion.Coupler110 mm
Providing and fixing on wall face unplasticised - PVC moulded fittin for unplasticised Rigid PVC rain water pipes conforming to IS : 135 including jointing with seal ring conforming to IS : 5382 leaving 10 thermal expansion.Single tee with door110x110x110 mm
Providing and fixing on wall face unplasticised - PVC moulded fittin for unplasticised Rigid PVC rain water pipes conforming to IS : 135 including jointing with seal ring conforming to IS : 5382 leaving 10 thermal expansion.Bend 87.5°,75 mm bend
Providing and fixing on wall face unplasticised - PVC moulded fittin for unplasticised Rigid PVC rain water pipes conforming to IS : 135 including jointing with seal ring conforming to IS : 5382 leaving 10 thermal expansion.Bend 87.5° ,110 mm bend
12 mm cement plaster finished with a floating coat of neat cement of mix1:3 (1 cement: 3 fine sand)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Smooth finishing of the exposed surface of R.C.C. work with 6 mm thickcement mortar 1:3 (1 Cement : 3 fine sand).
Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick.
Providing and fixing 2nd class teak wood plain lining tongued and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface.8.25.4 12 mm thick
Providing and fixing plain lining with necessary screws/nuts & bolts/ nails, including a coat of approved primer on one face, and fixed on wooden /steel frame work, complete as per direction of Engineer-incharge (Frame work shall be paid for separately). 9.140.1 12mm thick commercial ply conforming to IS : 1328 BWR type
French spirit polishing : 13.68.1 Two or more coats on new works including a coat of wood filler
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 9.40.1 2nd class teak wood 9.40.1.1 50x12 mm
Providing and fixing false ceiling at all height including providing andfixing of frame work made of special sections, power pressed fromM.S. sheets and galvanized with zinc coating of 120 gms/sqm (bothside inclusive) as per IS : 277 and consisting of angle cleats of size25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at1200 mm centre to centre, one flange fixed to the ceiling with dashfastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flangeof cleat fixed to the angle hangers of 25x10x0.50 mm of requiredlength with nuts & bolts of required size and other end of anglehanger fixed with intermediate G.I. channels 45x15x0.9 mm runningat the spacing of 1200 mm centre to centre, to which the ceilingsection 0.5 mm thick bottom wedge of 80 mm with tapered flangesof 26 mm each having lips of 10.5 mm, at 450 mm centre to centre,shall be fixed in a direction perpendicular to G.I. intermediate channewith connecting clips made out of 2.64 mm dia x 230 mm long G.I.wire at every junction, including fixing perimeter channels 0.5 mmthick 27 mm high having flanges of 20 mm and 30 mm long, theperimeter of ceiling fixed to wall/partition with the help of rawl plugsat 450 mm centre, with 25mm long dry wall screws @ 230 mminterval, including fixing of gypsum board to ceiling section andperimeter channel with the help of dry wall screws of size 3.5 x 25mm at 230 mm c/c, including jointing and finishing to a flush finishof tapered and square edges of the board with recommended jointingcompound , jointing tapes , finishing with jointing compound in 3layers covering upto 150 mm on both sides of joint and two coats ofprimer suitable for board, all as per manufacturer's specification andalso including the cost of making openings for light fittings, grills,diffusers, cutouts made with frame of perimeter channels suitablyfixed, all complete as per drawings, specification and direction ofthe Engineer in Charge but excluding the cost of painting with :12.45.4 Fully Perforated Gypsum Plaster Board of size 1200 x2400x12.5 mm having approx. 15 % perforated area withperforation size and pattern as approved by the Engineerin-charge and as per manufacturer's specification, with all 4 side tapered and backed by acoustical tissue withNRC value not less than
Providing and fixing thermal insulation with Resin Bonded Fibre glasswool conforming to IS: 8183 having density 24 kg/m3, 50 mm thick,wrapped in 200G Virgin Polythene Bags fixed to wall with screw,rawel plug & washers and held in position by criss crossing GI wire etc. complete as per directions of Engineer-in-Charge.
10.16 Steel work in built up tubular (round, square or rectangular hollow tubesetc.) trusses etc., including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer, including welding andbolted with special shaped washers etc. complete.10.16.1 Hot finished welded type tubes
Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as pproved by Engineer-in-charge)0.50 mm (+ 0.05 %) total coated thickness ith zinc coating 120grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 micronsepoxy primer on both side of the sheet ad polyester top coat 15-18 microns. Sheet should have protective guard film of 25 micronsminimum to avoid scratches during transportation and should besupplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 gramsper sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxyprimer on both side of the shee and polyester top coat 15-18 micronsusing self drilling/ self tapping screws complete : 12.51.1 Ridges plain (500 - 600mm)
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 gramsper sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxyprimer on both side of the shee and polyester top coat 15-18 micronsusing self drilling/ self tapping screws complete : 12.51.6 Gutter (600 mm over all girth)
Providing and Fixing 15 mm thick densified tegular edged eco friendlylight weight calcium silicate false ceiling tiles of approved texture ofsize 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising@ 120 grams per sqm including both side) consisting of main ‘T’runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced1200 mm centre to centre, and cross “T” of size 24x28 mm madeout of 0.33 mm (Minimum) sheet, 1200 mm long spaced betweenmain’T’ at 600 mm centre to centre to form a grid of 1200x600 mmand secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middleof the 1200x 600 mm panel to from grid of size 600x600 mm, restingon periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum)sheet with the help of rawl plugs at 450 mm centre to centre with 25mm long dry wall screws @ 230 mm interval and laying 15 mmthick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. sqm 1643.95 Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/ opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/ mK.
Stone tile (polished) work for wall lining over 12 mm thick bed of cementmortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqmincluding pointing in white cement complete. 8.9.1 8mm thick8.9.1.1 Raj nagar plain white marble/ Udaipur greenmarble/ Zebra black marble
Extra for plastering done on moulding, cornices or architraves including neat finish to line and level: 13.24.1 In one coat
Centering and shuttering including strutting, propping etc. and removal of form for :Cornices and mouldings
Excavation in soil in Hilly Area by mechanical means 1-1-1-A Excavation in soil in Hilly Area by mechanical means Withoutuseinng Dozer including cutting and trimming of side slopes anddisposing of excavated earth with a lift upto 1.5 m and a lead upto 20 m as per Technical Specification Clause 1603.1
Excavation in foundation for retaining & breast walls in all types of soils and rocks including lead, lift and disposal of surplus material as per direction of engineer - in - charge
Random Rubble Masonary laid dry in breast wall,retaining wall, parapets,scupper etc. Including supply of all materials,labour,t & p& royality etc,required for proper complition of work.(As per PWD Uttarakhand specifications)
Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, inbreast walls, retaining walls, parapets, scuppers, etc. including supply ofall material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction
Hand Packed stone filling in back of wallls including cost of all materials, royality, T&P etc. complete as per direction of Engineer-in- charge. (As per PWD Uttarakhand specifications)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .