Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹11.6 L
EMD Value
₹23,256
Closing Date
15 Dec 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX
Construction of Spawn Production Laboratory at Baramulla (Public Sector) under HADP B.W.O Electric work
2025_PWDJK_297183_1
NIT No.210/2025-26 Dt/03/12/2025
Open Tender
Electrical Works
Percentage
Baramulla
Please refer Tender documents.
4 documents required · 4 mandatory
₹600
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹23,256
3 Dec 2025
3 Dec 2025
16 Dec 2025
3 Dec 2025
15 Dec 2025
3 Dec 2025
Wiring for light point / exhaust /ceiling fan point with (P+N) 2X1.5 sq.mm FRLS-H ( Polycab/Havells/paraflex /Anchor eqt make as approved by site engineer),PVC insulated copper conductor single core cable in surface / recessed Conduits (Anchor/polycab/Ravindra/equivalent make as approved by site engineer) , with 6Amp .modular switch (Anchor roma urban/legrand Mylinc/SSK NV/equivalent make as approved by site engineer), modular plate, cover in front and suitable GI box etc of approved quality and make ISO/IEC Certified (quality of wire shall be approved before execution of wok by SITE In-charge Engineer strictly as required) job including cost of Circuit Wire in 2.5Sqmm Multi strand Copper wire from Switch board to D.B complete. including cost of Conduits
Supply and fixing of 6 amp/250 V A.C fan dimmer step type 2 module with cover plate Anchor Roma plus/SSK NV/ equivalent make as directed by engineer incharge.
Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Polycab/ Paraflex/Anchor / eq. make to be approved by EIC) (Including Cost of Conduit/Channel)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified Anchor roma urban/legrand Mylinc/SSK NV/equivalent make & shall be approved before execution of work.
Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Polycab/Anchor / eq. make to be approved by EIC) (Including Cost of Conduit/Channel)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Anchor roma urban/legrand Mylinc/SSK NV/ABB equivalent make & shall be approved before execution of work.
Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/ Recessed medium class PVC conduit as required. (wire shall be approved before execution of wok by SITE In-charge Engineer strictly .
2X 10sq. MM+ 1 X 10 sq. MM (Phase +N+E) Power point Sub main in One runFrom Main Panel to .Distribution boards(Polycab/Havells/Finolex/Parflex eqt make )
2 X 6SQ.MM + 1 X 6. SQ.MM [Phase +N+E) For Lighting and machine point Sub main in one run from Main Panel to Distribution board(Polycab/Havells/Finolex/ Paraflex eqt make)
2x4 sq.mm+ 1x4 sq.mm (P+N+E) for Inverter Sub main in One run from Main Panel to Distribution Boards.
4 X 6 sq. mm + 1 X 6 sq. mm earth wire for three phase machine points
SINGLE POLE (6-32Amp) Legrand /Havells or L&T /Schneider/ABB/ eq. make to be approved by EIC
Supplying and fixing following rating, Double pole, (P +N) 240 V, C* Curve (Miniature Circuit Breaker) MCB,having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as reqd.
40Amp. Legrand /Havells or L&T /Schneider/ABB/Siemens/ eq. make to be approved by EIC
63Amp. Legrand /Havells or L&T /Schneider/ABB/ Siemens/ eq. make to be approved by EIC
32 Amp. Legrand /Havells or L&T /Schneider/ABB/ Siemens/ eq. make to be approved by EIC
Supplying and fixing following way, Triple pole and neutral, sheet steel, MCB distribution board,( Havell/ legrand/ Shinider/SSK make) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. without MCB/RCCB/Isolator)
6 way (4 + 24), Double door
ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER Rod EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value .Supplying, Installation and Testing of 75 mm copper Pipe Filled with Crystallineconductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 2OMM Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through DWC High Density Poly ethylene Pipe having Corrugation complete job
Supply installation testing and commissioning of 18 W + LED Surface Mounted Panel light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India authorised lab . The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips or Havells or Halonix or Eq make
Supply, Installation, Testing and Commissioning of 1200 mm sweep, ceiling fan with 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase Supply, etc. complete as required. USHA/Havells/Polycab/ LUKER USA / eq. make to be approved by EIC duly approved by site Engineer (3 star)
Supply,Installation,Testing and Commissioning 320 Cu.m/Hr. AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37 dB of Following Sizes including connection etc. Compt 225-250mm Shutter Typed USHA/Havells/Polycab/ Eq Make
Providing & Fixing of IK08 IP-66 protected high power LED 50 Watt flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 Im/wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K 355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. Minimum lumen output 6200 Im of Havells/Crompton/Philips/Halonix Make as approved and to be installed on outside block including S/F of suitable size of Gyser bolt.The job further includes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning /handing over of site to intending department. Havells/Philips/HG/Eq make
Supply/Installation/Testing and Commissioning of 1 feet Long Mirror Light having Aluminium Body and having minimum system lumen efficacy of 100 lm/W of Havells/Philips/Wipro/Eq.Make
Supply/Laying/Connecting and Commissioning of 70 sq.mm 3.5-Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havells/RR / eq. make to be approved by EIC with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench .(Material to be approved before execution)
Supply/ installation/testing and commissioning of CPRI Approved (IS/IEC:61439) panel Wall nounted compartmentalized , Mian Distribution panels ,fabricated out of sheet steel of 16 gauge dust protected, painted incl earth terminal with all necessary accessories as required for panel with internal wiring of panel .The Panel is to provided and fitted with following adjustable type controlling /Protection switch gear devices (1) Normal Incoming 200 Amp TPN MCCB 35 kA with thermo magnetic adjustable based of Legrand / Siemens/ ABB /Schinder /L&T make = 1 no 300 Amp TPN Bus bar Al Strips = 1 Set Volt meter =1 no, Ammeter = 1 no ,phase indicators =1set 100 Amp 4 Pole change-over to switch from normal supply to DG supply Legrand/Havells/L&T/Schineider/ABB make Outgoing: 1) 40 Amp DP = 2 No. for Lighting Circuits 2) 63 Amp DP = 2 No. for Heating Circuits 3) 32 Amp DP = 2 No. for inverter Circuits of Legrand/Havells/L&T/Schineider/ABB / eq. make to be approved by EIC 4) 63 Amp TPN = 2 No. for three phase supply of Legrand/Havells/L&T/Schineider/ABB / eq. make to be approved by EIC
Supply ,installation ,testing , &commissioning of 15 KVA 3 -Phase SERVO controlled VOLTAGE Stabilizer of Approved brand with following SPECIFICATIONS : (1). INPUT VOLTAGE: 156 Volt -450 Volts P-P (90V-260V N-P) (2). OUT PUT VOLTAGE : 400Volts+ 1%(230VAC) (3).Winding Material Insulation : 99.97% PURE COPPER WOUND FIBER GLASS (4). IN DOOR TYPE (5). COOLING :OIL 1S 335 (6).MICRO CONTROLLED TRUE RMS Based LCD display (7). Protections are Over Load COPPER wound of Electric Field /Alba /AE /Cosco/ eq. make to be approved by EIC etc ISI/1SO certified for smooth functioning/ constant voltage supply having Technical Specifications : Input voltage= 90-260 volts & output voltage=220 volts+ - 2% Buck Boost Transformer Copper wound 99.9% ,OIL Immersed COOLING OIL ,High cut/Low Cut /Time delay / Over Cut through Micro Control and Spike Protection including ,Carriages ,installation charges , testing & taxes complete job alongwith servo bypass switch of adequate rating.
Supplying, Installation, Testing and Commissioning of ABC type Fire Extinguisher 4.Kg. Capacity ISI Mark(IS:15683) and dully certified
Supplying, Installation, Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark(IS:15683)suitable for 'B' and 'C' class fires - inflammable liquids, gaseous fires like L.P.G. and acetylene, and electrical fires
Supplying and fixing 63 A, 415 V, TPN Industrial type socket outlet,with 4 pole and earth, metal enclosed plug top alongwith 63 A "C"curve, TPN MCB, in sheet steel enclosure, on surface or in recess,with chained metal cover for the socket out let and complete with connections, testing and commissioning etc.for three phase machine points
Supply/Installation/Testing/Commissioning of Inverter 10 KVA/96 V Pure Sinewave Inverter With ISOT Technology, Intelligent Load Sharing & BIS Certified (with 2-Year Warranty), 08 No. of 200Ah,12V Tubular battery (with 60 Months Warranty) & Suitable Trolley Support for Inverter resting & resting of Tubular Battery etc /Luminious/EXIDE /AMRON/Eq. Make
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.92 MB
BOQ_963203.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .