| 1 | 3₹23.7 LAccepted-AOC | ₹23.7 L Quoted ₹24.3 L | 3 | Accepted-AOC AOC |
| 2 | 2₹28.8 LRejected-AOC B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | ₹28.8 L | 2 | Rejected-AOC NOT ACCEPTED |
| 3 | 3₹30.2 LRejected-AOC | ₹30.2 L | 3 | Rejected-AOC NOT ACCEPTED |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
19 Jun 2023, 6:00 pmClosed
GE ARMY BHUJ
GE ARMY BHUJ
CERTAIN REPAIR/ REPLACEMENT OF LT DISTRIBUTION LINES AND UNSV LT UG CABLE SWITCH GEAR AND OTHER CONNCTED WORKS UNDER AOR OF GE(A) BHUJ
2023_MES_597383_1
8121
Open Tender
Civil Works
Item Rate
270 days
ARMY AREA BHUJ
REFER TENDER
6 documents required · 6 mandatory
₹500
GE ARMY BHUJ
₹60,000
Yes
30 Jun 2023
22 May 2023
20 Jun 2023
22 May 2023
19 Jun 2023
7 Jun 2023
Amount
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc for laying of cables, erection of poles, struts/ stays etc not exceeding 10 sqm on plan and getting out in soft loose soil.
Returning, filling in, including spreading leveling watering and well ramming in layers not exceeding 25 cm in any type of soil.
Removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in soils.
M & L for sand filling in trenches for cushioning of LT cables punning after filling complete as specified and as directed. Note: Punned thickness shall only be measured and paid
Supply and lay un-reinforced precast concrete cable cover , class , LV , Type I flat size 250 x 150 x 40 mm laid dry in treches over under ground cables.
S & F GI pipe, light grade, of size 50 mm dia including necessary fittings laid in trenches/fixed on wall/pole for LT cable protection and taking down the old GI pipe, complete all as speicifed and directed for cable protection .
S & F GI pipe, light grade, of size 40 mm dia including necessary fittings laid in trenches/fixed on wall/pole for LT cable protection and taking down the old GI pipe, complete all as speicifed and directed for cable protection .
Disconnecting, taking out, removing old existing unserviceable LT underground cable and Supplying ,Laying, jointing and testing new XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed of size 2 core 6 sqmm
- do- as per Item 8 here in above but of size 2 core 10 sqmm
- do- as per Item 8 here in above but of size 3.5 core 25 Sqmm
- do- as per Item 8 here in above but of size 3.5 core 35 Sqmm
- do- as per Item 8 here in above but of size 3.5 core 50 Sqmm
- do- as per Item 8 here in above but of size 3.5 core 70 Sqmm
- do- as per Item 8 here in above but of size 3.5 core 95 Sqmm
- do- as per Item 8 here in above but of size 300 sqmm, 3.5 core.
- do- as per Item 8 here in above but of size 150 sqmm, 3.5 core.
- do- as per Item 8 here in above but of size 185 sqmm, 3.5 core.
M&L for refreshing of incomming and all outgoing XLPE cable at panels /DBs of any size,disconnection of cable , including excavation for taking out cable from loop, refreshing of exsiting all cables by removing damaged insulation portion, providing insulation using best quality insulation tape ,cleaning of panel inside and ouside using vaccum cleaner ,including removing old damaged lugs/thimble with new one as per existing size, MS nuts ,bolts,washer to all incomming and outgoing MCCB as sepcfied and directed by Engineer-in-charge.
M&L for repair of LT panel doors using 75 mm SS hinges, SS latch, including welding work all as specfied and directed by Enginner-in-charge.
M&L for spray painting of LT panel inside and outside surface, including surface prepration by scrubbing of existing paint, and applying two coat of synthtic enamel paint over one coat of red oxide, colour of paint & pattern as per exsiting all as specfied and directed by Enginner-in-charge.
Supply and fix in repiars the following items and disconnecting,taking out the old unserviceable one, including necessary replacemnet of lugs ,nuts,bolts lugs of any size and capacity wherever reqd :-
MCCB Thermal Magnetic release,Ics=100% of Icu, Adjustable over load 0.8 to 1 In,Adjustable Short circuit current 6-10 In , 4 pole 63 Amps 16 KA.
MCCB Thermal Magnetic release Ics=100% of Icu, Adjustable over load 0.8 to 1 In,Adjustable Short circuit current 6-10 In , 4 pole 100 Amps 16 KA.
MCCB Thermal Magnetic release Ics=100% of Icu, Adjustable over load 0.8 to 1 In,Adjustable Short circuit current 6-10 In , 4 pole 160 Amps 36 KA.
MCCB Thermal Magnetic release Ics=100% of Icu, Adjustable over load 0.8 to 1 In,Adjustable Short circuit current 6-10 In , 4 pole 250 Amps 36 KA.
MCCB Thermal Magnetic release Ics=100% of Icu, Adjustable over load 0.8 to 1 In,Adjustable Short circuit current 6-10 In , 4 pole 400 Amps 36 KA.
Cleaning of surrounding area of electric panel/transformer/starter panel/4pole structure , removing shurbs and creeper on electrical poles/chain link fencing all as specfied and directed by Enginner-in-charge
M&L for cable jointing kit LT 1.1KV straight through joint 185sqmm ,heat shrinkable type with all accessories all as specfied and directed by Enginnee-in-charge.
M&L for cable jointing kit LT 1.1KV straight through join 150 sqmm ,heat shrinkable type with all accessories all as specfied and directed by Enginnee-in-charge.
M&L for cable jointing kit LT 1.1KV straight through joint 120sqmm ,heat shrinkable type with all accessories all as specfied and directed by Enginnee-in-charge.
M&L for cable jointing kit LT 1.1KV straight through joint 95 sqmm ,heat shrinkable type with all accessories all as specfied and directed by Enginnee-in-charge.
M&L for cable jointing kit LT 1.1KV straight through joint 70 sqmm ,heat shrinkable type with all accessories all as specfied and directed by Enginnee-in-charge.
M&L for cable jointing kit LT 1.1KV straight through joint 50sqmm ,heat shrinkable type with all accessories all as specfied and directed by Enginnee-in-charge.
M&L for cable jointing kit LT 1.1KV straight through joint 35sqmm ,heat shrinkable type with all accessories all as specfied and directed by Enginnee-in-charge.
M&L for cable jointing kit LT 1.1KV straight through joint 25sqmm ,heat shrinkable type with all accessories all as specfied and directed by Enginnee-in-charge.
Fabricate, Supply, Install, Testing and Commissioning LT Panel Board outdoor type, double door, front & back openable, air vent, cable alley, locking arrangement with pad lock, factory made CPRI tested made out of CRCA sheet steel enclusure 3.15 mm thick outer & inner sheet 2mm thick, including copper bus bar 4 pole including wiring of rated capacity PVC insulated copper conductor cable, insulators, fasteners etc, MS Angle Frame of size 50x50x6 mm structure at bottom, PCC foundation 1:2:4 for foundation etc comprising for the following :- Note : Drawing of panel shall be submitted to gate the approval of Engineer -in Charge before placing of order..
Incoming
(a) Copper Bus Bar 375 A rating for 4 Pole including sleeves as per colour coding
(c) LED Indication Lamp for 3 Phase - 08 Sets( 3 in each set)
(f) MCCB 4 Pole 250 Amps 36 KA Adjustable overload settings: 0.8 - 1.0 x In l Adjustable short-circuit settings: 6 - 10 x In I- 01 Nos
(g) On load Manual Change over of capacity 250A ,415V
Outgoing
(a) MCCB 4 Pole 160 Amps 36 KA Adjustable overload settings: 0.8 - 1.0 x In l Adjustable short-circuit settings: 6 - 10 x In I- 01 Nos
(b) MCCB 4 Pole 100 Amps 36 KA Adjustable overload settings: 0.8 - 1.0 x In l Adjustable short-circuit settings: 6 - 10 x In I - 02 Nos
(c) MCCB 4 Pole 63 Amps 36 KA Adjustable overload settings: 0.8 - 1.0 x In l Adjustable short-circuit settings: 6 - 10 x In I - 01 No
Supply, erecting and fixing in true vertical position, Prestressed cement concrete pole 9 mtr long confirming to IS-1678 (latest) with minimum cross sectional area 102 mm x 152 mm at top and 102 mm x 289 mm at bottom , class - 10 with and Including all necessary excavation & earth work in any type of soil for foundation of poles, PCC 1:3:6 type (C-2) (using 40 mm graded stone aggregate ) in foundations of size 1.20 m X 0.60 m X 1.65 m below GL, PCC 1:2:4 type (B- 1 )(using 20 mm graded stone aggregate) in plinth block(coping) of size 600 X 600 X 300 mm above GL , removing surplus soil to a distance n. exc. 50 m & depositing where directed, including necessary form work and and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30cm in between 2 bands and numbering of poles, and numbering of the poles shall be done with synthetic enameled painted letter of shape & size complete( M&L)all as specified and directed. (Note -SSR part I clause No.19.5 & 19.52 and other relevant clauses of SSR refers for execution of work and poles shall be procured directly from the manufacturer mentioned in tender documents.)
S&F PVC insulated spacers, 12mm dia flexible type suitable for making / turning to any shape and size and suitable for 4 conductor runs including disconnecting, dismantling and taking down existing unserviceable spacers of any description and in any position from the LT electric overhead lines of any height complete all as specified and directed. NOTE : The spacer shall be of best quality and as per the sample kept in GE office.
Dismantling of old unserviceable stay assembly, and Supply and fix Stay assembly complete with all accessories as shown in electrical plate no. 1 of SSR Part - I ,1991, using stay rod 16 mm dla including stay wire. Note :- Excavation , earth work , foundation concrete ,loop insulator, stay clamps, for the new stay shall be measured and paid separately under respective item of schedule
Supply and fixing galvanized stay strand of 7/4mm
supply and fix loop insulator of size 65X90mm ,clerance hole 16mm brown colour all as specifed and directed
Supplying and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed round twin core cable of size 6 Sqmm.
Supplying and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed round twin core cable of size 10 Sqmm.
M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected tog galvanised iron strip 25×4mm as earthing lead , (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed. NOTE: Earth strip and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’ NOTE - (i) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, RCC 1:2:4 type B1 cover 50mm thick reinforced, funnel with watering pipe. (ii) A colour photographe of earthing pit and test report of earthing will be submmited alongwith RAR witout which the RAR shall not be permmited for that items.
Supply and fix Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of size 25 mm x 4mm aluminium strip all as specified and directed .
Supply and fix test point termination block of size 75 mm x 75 mm x 25 mm made of Gun Metal or phospherous bronze drilled and screwed including 3 Nos, 8 mm dia 25 mm long hex head screw and box of size 90 x 90 x 90 mm (Made out of 1.6 mm thickplain brass sheet) and screwed to wall for protection of test point complete all as specified and directed.
Supply and fix porcelain type, pin type insulator including one galvanised MS spindle,two galvanised iron washer and one one galavanised iron nut ,50mm height,65mm dia for 1100 volt grade
Supply and fix shakle insulator porcelain type for LT of 1100V grade all as specifed and directed
S & F MS Frame work for fixing insulators, supporting channel, including cutting, Jointing, welding & necessary fabrication including provn of MS angle iron of any description complete as specified and as directed.
(1) The contractor shall keep all items readily available at site, which is required for urgent repair works.
(2) Common miscellaneous material such as screws any type, nails, washers, insulation tapes, clamps, hooks, which are required for the work the cost of which is deemed to be included in quoted rate.
(3) All tools & tackles, plants, machineries, equipment and material to carry out the work at site which is to be decided by GE (A) Bhuj shall have to be provided by the contractor at his/ her own cost.
(4) Contractor’s supervisor (electrical engineer) should be available at the site to supervise the works and co-ordinate with the officials.
(5) The contractor shall ensure safety of his workers and other at site of work and shall be responsible for any consequence arising out of execution of the repair and maintenance works.
(6) The contractor shall ensure that his repair/ maintenance staff is qualified and licensed for their part of work. He shall be responsible for their conduct. The contractor shall be held responsible for any loss or damage to employees’ state insurance corporates property.
(7) It is responsibility of contractor to clean the area after repair work of appliances. Rates are deemed to be include in his quoted rates of respective items.
(9) Any person of contractor causes damage of equipment or property of Military station, the contactor will be solely held responsible for the cost of consequences thereof.
(10) Joint measurement shall be done weekly. The contractor should be available for joint measurement along with supervisior on every Wednesday from 15.00 hr to 17.00hr
Abhishek Enterprises
MAA PUNAGRI ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .