Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹42.5 LAccepted-AOC | 1 | Accepted-AOC AOC | |
| 2 | 2₹48.2 L+₹5.3 L (12.4%)Rejected-AOC GANDHI NAGARI AIRPORT ROAD BHUJ KUTCH PIN 370 001 GUJARAT | KACHCHH | GUJARAT | 370001 | 2 | Rejected-AOC NOT ACCEPTED | |
| 3 | 3₹49.7 L+₹6.7 L (15.7%)Rejected-AOC WANIAWAD BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | 3 | Rejected-AOC NOT ACCEPTED | |
| 4 | 4₹50.6 L+₹7.6 L (17.8%)Rejected-AOC PLOT NO 86 SHIVAM PARK 2 AIR PORT ROAD BEHIND SANATAN MANDIR BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | 4 | Rejected-AOC NOT ACCEPTED | |
| 5 | 5₹50.7 L+₹7.8 L (18.1%)Rejected-AOC | 5 | Rejected-AOC NOT ACCEPTEDNOT ACCEPTED |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
13 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(ARMY) BHUJ
GE(ARMY) BHUJ
SPL REPAIR FOR BLDG NO P34 P-100 T 292 T193 AND PROVN OF DEFICENT EQUIPMENT OF SIG COY AT MIL STN BHUJ UNDER GE (A) BHUJ
2023_MES_613628_1
8151
Open Tender
Civil Works
Item Rate
180 days
ARMY AREA BHUJ
REFER TENDER
6 documents required · 6 mandatory
₹500
GE(ARMY) BHUJ
₹96,000
Yes
12 Oct 2023
14 Aug 2023
14 Sept 2023
14 Aug 2023
13 Sept 2023
29 Aug 2023
Amount
Dismantling floor, hearth or wall tiling of any description and in any position including cement mortar bedding (but not backing) complete all as specified and directed.
Roughening surfaces of old concrete floor by picking , sweeping cleaning and washing down with water to remove dust etc. Complete all as specified and directed
M&L vitrified ,coloured and printed tiles of size 600 mmx600 mm x 9 to 10 mm thick as in flooring over and including 15 mm thick cement screed in (1:4 ) CM set and jointed in neat cement slurry set and pointed in white or coloured cement to match with the colour of tiles, with all possible design combination as specified by Engr-In-charge complete all as specified and directed.
M&L matt finish ,coloured and printed tiles of size 600 mmx600 mm x 9 to 10 mm thick as in flooring over and including 15 mm thick cement screed in (1:4 ) CM set and jointed in neat cement slurry set and pointed in white or coloured cement to match with the colour of tiles, with all possible design combination as specified by Engr-In-charge complete all as specified and directed.
M&L vitrified ,coloured and printed tiles of width as directed and 9 to 10 mm thick as in skirting fixed over and including 10 mm thick cement backing coat in (1:4 ) CM set and jointed in neat cement slurry set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles with all possible design combination as specified by Engr-In-charge complete all as specified and directed.
M&L Coloured Glazed Ceramic tiles (Digital Designer tiles) 300 x 450 and 6-7mm thick on vertical surfaces such as skirting, dados and risers to steps etc including 10mm thick backing coat in CM 1:4 with all possible design combination as specified by Engr-In-charge complete all as specified and directed by Engineer-in-Charge..
M&L non skid ceramic tiles(Coloured) 7 to 8mm thick (square/rectangular) area of each tile exc 0.06sqm but n.exc 0.11 sqm, in in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including screed bed 15mm thick in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
Demolition of precast concrete block walling and similar items i.e.. ashlar facing dressed stone work, precast concrete articles etc., of any description and in any position, built in cement mortar, including all quoins, arches and pillars etc. complete all as specified and directed.
M& for RCC TypeB0 1:2:4 (12.5mm graded aggregate) nominal mix for the First Floor and Second Floor Chajjas , slab ,Front Projections incl necessary Formwork and Complete all as specified and directed
M&L for precast cement concrete block masonry with solid blocks of PCC (1:3:6) (using 20mm and 12.5 mm graded stone aggregate in the proportion as directed) exc 10cm in width and set and jointed in Cement Mortar (1:6) complete all as specified and directed.
Taking down cement plaster of any description and in any position of brick/concrete surfaces on walls/celling etc. including racking out joints, hacking for key, scrubbing down with water etc & prepared to receive new plaster complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar on fair faces of brick work or concrete surfaces , applied in two layers i.e.. Ist layer of 10 mm thick rendering in cement mortar (1:6 ) and 2nd ( top ) layer of 5 mm thick rendering in cement mortar (1:4 )
M&L for rendering 10 mm thick in CM (1:4) on fair faces of brick work or concrete surfaces/stone masonry and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly/old plastered surfaces of walls & applying 2 coat of cement base paint over a coat of alkali resistance primer complete all as specified and directed.
Dismantling water tanks of any description and in any position , of capacity exceeding 500 litres but not exceeding 1000 litres complete all as specified and directed.
S & F Rotational moulded poly-ethylene multilayer water storage tanks (cylindrical vertical with closed top) 1000 litres capacity, white in colour hoisted and fixed in position with and including all fittings and fixtures in repairs complete all as specified and directed.
S&F Ball brass valves , high pressure , with polythene float and fly nut complete & high-density plastic ball , suitable for 20 mm bore pipe, screwed for iron pipe and fixed.
Demolition of cement concrete of any description and in any position (unreinforced) in ground floors/ paving not exceeding 15 cm thick (below or above GL) complete all as specified and directed.
Demolition of cement concrete of any description and in any position (reinforced) in slab etc complete all as specified and directed.
M&L for PCC (1:3:6) type C2, (using 40mm graded stone aggregate) as in plinth protection, 75 mm thick, finishing the surface even and smooth w/o using extra cement including forming & filling expansion joints 65 mm deep x 10 mm wide filled with sealing compound grade A complete all as specified and directed.
Taking down chowkat or frames n.exc 1.5 sqm with shutters without taking off shutters from the frame and removing to store
Taking down chowkat or frames exc 1.5 sqm & n exc 4 sqm with shutters without taking off shutters from the frame and removing to store
S & F powder coated anodised Aluminium alloy sections sliding windows with frames 92 X29.6 X1.10mm , 3 track sliding shutters wt not less than 0.55 kg/m duly fitted with neoprene beading, glazing clips, two shutters tinted glass panes 4.80 mm nominal thickness one shutter with stainless steel wire cloth 0.45mm dia and average width of aperture 1.4mm , aluminium alloy handles etc. complete all as specified and directed.Note : Making all edges i.e. cill and jamb good by cement mortar 1:3
S & F for anodised Aluminium partition/ door frame of size 100 x44 x 1.98mm thick with one or more rebates and shutters pull and push type or side hung type (with or without aluminium sash bars) comprising of top & lock rails of section 115 x 44 x 1.98mm thick, bottom rail of section 150 x 44 x 1.98mm thick and stiles of section 85 x 44 x1.98mm thick including necessary jointing cleat, glazing clip, rubber packing anodized aluminium beading, screws, anodized aluminium fittings such as floor spring or hinges 100mm size with hydraulic door closer, handles 'D' type 125mm, floor door stopper, tower bolts 200mm, sliding door bolt 300mm or mortice lock with 5mm thick tinted glass /pre laminated particle board (Novapan) panel and making good to the disturbed wall surfaces to match existing surface complete all as specified and directed.
M & L powder coated aluminium deco grill medium grade of mesh size 75mmx75mm with 6mm square anodised aluminium bars fixed with aluminium frame of size 9mmX9mmX1mm all as specified
S&F powder coated aluminium anodised ventilator with fixed aluminium frame of size 65 x 40 x 1.98mm thick fixed in vertical position with aluminium vertical members and half portion to be provided with 4mm thick pin head glass and remaining portion to be louvered using 4mm thick pin head glass and louvered portion covered with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm incl necessary channel frame work, including rubber gasket and aluminium beading complete all as specified.
S&F factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles & prelam both side colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail ; panelling of prelam colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading & jointed together with solvent cement, supply & fixing in the frame at site as per SSR specifications & diagram/product drawing shown on sl page NO 146 of SSR Part II with the size of door shutter as required & directed by the Engr-in-Charge.
S&F solid PVC door frame of size 50mmX47mm made out of 5mm one side prelam colour PVC sheet reinforced with MS square tube all as per specifications and as per drawing shown on sl page No 150 of SSR part II (for item-884)
S&F 30 mm thick factory made Flush shutters , solid core construction , with block board core and plywood face panels commenrcial face on bath sides with lipping/frame to match complete all as specified and directed.
M & L for 30 mm thick glazed and skeleton shutters of 2nd class Hard Wood(Not less than Hollock wood) local made shutter, open rebated and prepare to revive glass, gauge etc (without sash bars ) edges of framing plain chamfered or rounded, fitted with moulded beads both sides for securing glass etc, size of members of shutters as specified in SSR part I section 8 clause 8.24 (a) supplied and fitted to chowkat complete all as specified and directed.
M&L preparation of the new wooden surfaces exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S&F 100 mm long butt hinges stainless steel medium weight and fixed to wooden or PVC frame fixed in repairs by stainless steel screw as directed by Engr-in-Charge.
S&F aluminium handles cast type, anodized of 150 mm size complete all as specified and directed.
S&F 150 mm long aluminium anodised , barrel tower bolt of extruded section and fixed all as specified and directed.
S&F butt hinges 100mm long medium weight, cold rolled mild steel.
S&F Aluminium alloy, anodised, sliding door bolt 250mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
S&F vitreous china squatting pan, Orissa pattern, size 580 x 440 mm white with integral foot rests and connection to trap and to flushing pipe, anti siphonage pipe etc(including flushing cistern and flush pipe) complete with provision of lime concrete bedding including taking down existing unserviceable WC of any description and in any position & fixing new WC in repair and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed.
S&F Vitreous China, wash down water closet pan "Pedestal pattern" white including connection to drain and to flush pipe and anti syphonic pipe including all joints and making good the disturbed surfaces complete all as specified.
S&F PVC connections 15 mm dia and 450 mm long with brass nuts complete all as specified
S&F in repair sinks with drainage board made out of stainless steel 1 mm thick kitchen or laboratory with ;plugs, washers, and waste pipe including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets, and connecting union to pipe overall size 915 mm x 460 mm with bowl size 410 mm x 330 mm x 160 mm complete all as specified and directed .
S & F in repair vitreous china wash basin, white flat back , size 550mmx450mm with and including Waste fittings, brass, chromium plated for basins with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed with and including Supplying and fixing cast copper alloy chromium plated, fancy type, pillar tap, 15mm bore, screwed down high pressure with or without lettered hot or cold with long shanks, screwed for iron pipe complete all as specified and directed .
Dismantling of stone slabs and tiles (Kota stone etc.) of any description or any thickness in floors, aprons, skirting, dado etc. laid bedded and pointed in any mortar complete all as specified and directed.
M&L for machine cut kota stone slab 20-25 mm thick as in floor laid and jointed with grey cement slurry mixed with pigment to match with the shade including rubbing and polishing over and including 15 mm thick screed bed in CM (1:6) complete all as specified and directed.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in cooking platform, Jambs cill and like set in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match shade of granite including rounding of exposed edges of slab smoothly and polished complete all as specified and directed.
S&F in repair for shower rose brass chromium plated without swivel joints, 125 mm in size including fixing to steel pipe complete all as specified and directed fixed in repairs.
S&F in repair PVC (SWR) Nahni trap 75 mm bore, plain with grating including jointing with solvent cement complete all as specified and directed.
S&F in repair PVC (SWR) floor trap 75 mm bore, plain with grating including jointing with solvent cement complete all as specified and directed.
S&F in repair Bib taps , cast copper alloy screwed down high pressure with crutch or butter fly handle fancy type long body CP for 15mm dia bore GI Pipe or for brass ferrule and fixed complete all as specified .
S&F in repair Stop valves, fancy type chromium plated ISI marked , cast copper alloy, screwed down high pressure for 15 mm bore dia GI tubing pipe, high pressure, with crutch butter fly handle complete all as specified
Taking down eaves gutters and rain water pipes (any size 75mm to 110mm of any pattern) ,of any description and in any position, including all fittings , heads, shoes, bends, swan necks, etc., (measured overall as fixed along the centre line over fittings and accessories)complete all as specified.
S&F 110 mm bore PVC (SWR) pipes ISI marked Type B single socketed in any length with rubber ring joints fixed on walls complete all as specified and directed
S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed on walls complete all as specified and directed
S&F PVC (SWR) bends, 110 mm bore, any radius with access door complete all as specified and directed.
S&F PVC (SWR) bends, 75 mm bore, any radius with access door complete all as specified and directed.
S&F PVC (SWR) Junction, single, (single T) equal or unequal with access door, 110mm bore, complete all as specified and directed.
S&F PVC (SWR) Junction, single, (single T) equal or unequal with access door, 75 mm bore, complete all as specified and directed.
M&L for PVC (SWR) vent cowl, 110 mm bore complete all as specified and directed.
M&L for PVC (SWR) vent cowl, 75 mm bore complete all as specified and directed.
S&F (concealed / open) 16mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified complete with fitting including taking down existing GI tubing 15mm bore..
S&F (concealed / open) 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified complete with fitting including taking down existing GI tubing 20mm bore.
S&F (concealed / open) 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified complete with fitting including taking down existing GI tubing 25mm bore.
S&F (concealed / open) 40mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified complete with fitting including taking down existing GI tubing 40mm bore..
M& L for Complete removal of existing treatment on old plastered surface or new surface and applying two coat of acrylic weather proof paint (Exterior grade) over a coat of primer Complete as all specified and directed by Engineer-in-Charge
M & L for complete removal of existing treatment on walls on old plastered surface or new surface and applying two coat of distemper oil emulsion over a one coat Putty to to prepare the surface even and smooth complete all as specified and directed.by Engr-in-Charge
Preparation of old decorated surface of ceiling and including cornices plastered or unplastered surfaces by brooming down or steel wire brushing to remove all loose scales, and foreign materials scarping down , smoke soot moulds , moss and efflorescent salts treating oil and greasy spots and applying one coat of white wash complete all as specified and directed.by Engr-in-Charge
Preparation of old decorated surface of wall and including cornices plastered or unplastered surfaces by brooming down or steel wire brushing to remove all loose scales, and foreign materials scarping down , smoke soot moulds , moss and efflorescent salts treating oil and greasy spots and M&L applying one coat of white wash , complete all as specified and directed. by Engr-in-Charge
S&F in repair stainless steel grating 150 x150mm size over floor trap anti cockroach all as approved sample all as specified and directed by Engineer-in-Charge
S&F pillar taps in repair of cast copper alloy with capstan heads chromium plated fancy type screwed down high pressure with long swan shanks and fly nuts screwed for iron pipe, 15mm bore fancy type
Dismantling plain or corrugated A/C or steel sheeting, any guage of any description and in any position as in roof coverings and S &F for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550MPa as in roof covering / cladding to wall, fixed with L or J hooks all as specified and directed.
Dismantling plain or corrugated A/C or steel sheeting, any guage of any description and in any position as in roof coverings and S &F for pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550MPa as in ridge etc fixed with L or J hooks all as specified and directed.
Dismantling structural steel work of any description and in any position including doors, gates but excluding framed truss etc. complete all as specified and directed.
S&F Roof trusses (framed) trusses purlins and fastening (etc., angle, channel, tubular section, round pipe) or flat section including distance pieces, MS plates/ gusset plates, cleats, hold fast etc. conforming to Gde of steel Fe 410-0 or Fe 310-0 complete all as specified and directed.
M&L foe preparation of new steel surfaces exc 10 cm width or girth and applying two coat synthetic enamel paints on new steel surfaces over a coat of red oxide zinc chrome primer complete all as specified and directed.
M&L for chequered cement concrete tiles 250mm x 250mmx 25mm thick, set jointed and pointed in cement slurry in floors with grey cement and pigments including 15mm thick screed bed in CM 1:6 complete all as directed
M&L PCC 1:3:6 type C2 using 40mm graded stone aggregate as 75mm thick finished fair all as specified
S & F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. Health faucet fixing in pipe etc. complete
S & F Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden /plastic cleats(Minimum weight 190gms)
M&L for false ceiling work of powder coated aluminium ceiling grid system 'UNLOCK" comprising of main runner 38mmx24mmx0.35mm cross tee 4mmx24mmx0.40mm and GI suspenders 8mm dia fixed to ceiling with and including supply and fixing mineral fibres acoustic ceiling board of size 600x600x12mm thick complete all as specified and directed and fixed as per manufacturers instructions including taking down existing ceiling of any description and in any position and making good the disturb surfaces to match with the existing surfaces and finishes complete all as specified and directed.
S&F in repairs heavy duty Stainless steel (Grade 305) curtain rods 20 to 25mm dia.
S&F in repairs Stainless steel (Grade 305) brackets (Open ends) suitable for curtain rods of 20 to 25mm dia
S&F in repairs Stainless steel (Grade 305) brackets (Dead ends) suitable for curtain rods of 20 to 25mm dia
S&F in repairs Stainless steel (Grade 305) supports suitable for curtain rods of 20 to 25mm dia
Dismantling,repair and refixing of old steel locker all as specified and directed by engr-in-charge
Supply and Fix in repairs, seamless ceiling with using 12mm thick, factory made gypsum fibber board, fixed on GI frame work for seamless ceiling suitable for suspended system with and including applying two coats of oil bound distemper over a coat of primer to give even and smooth finish without showing any joints complete all as specified and directed.
S&F Solid PVC Wall Lining consisting of 5mm thick Plain wood grain printed PVC sheet inclusive of solvent cement and fixing at site on as per specification and drawing comlete all as specified and directed .
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling (At the spacing of 1 feet centre to centre) inclusive of fixing on to wall to make PVC Frame as per specification and drawing.
Taking out old existing roof treatment including pvc and Material and labour for water proofing treatment to roof slab by applying one coat of bituminous / polymerised primer confirming to IS 3384 @ 0.30 Ltr /sqm and laying grit finish Acetic Polypropylene (APP) modified membrane pre-fabricated , reinforced with non woven polyester of 3.50 kg / sqm (minimum) and 3mm thick minimum and making side lap of 75 mm and 100 mm end overlaps and inserting inside the parapet walls alround 15 cm to avoid any leakage from the walls and before apply of APP membrane first make surface smooth by pvc 1:2:4 (25mm) thick and plaster 1:4 (10mm )thick and then application of APP membrane ,complete all as specified and directed.
Dismantaling and taking down copper / aluminium point wiring any type / size complete with removing all connection and accessories such as switches , sockets, ceiling rose,pendent holder,fan regulator any type , all type of fitting , batten , steel or PVC conduit , casing caping etc compele and making good the disturbed surface.
Taking down old and unserviceable sub main wiring any size / type / core incl earth wire complete with batten/conduit etc and making good the disturbed surface to match the existing disturbed surface all as directed by Engr-in-charg.
Taking down old and unsrevicable sheet metal enclosure , switch fuse unit , distribution bord any type /way / capacity including fuses,MCB's , insulator etc complete after removing all connection and making good the disturbed surface all as directed by Engr-in-charg.
M&L for point wiring with using 1.5 Sqmm (nominal area) multi standard copper conductor, single core, FRLS PVC insulated & unsheathed cable, 1100 volts grade with and including PVC conduit pipe of adequate size concealed type on any type of wall / fixed to surface ceiling with PVC rawl plugs with sunken type pressed steel terminal box suitable for laminated board or Modular fititng board and junction boxes 1.6mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, FRLS PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed for following:- NOTE :- (i) Quoted rate shall be deemed to include the cost of cutting chases in walls / pillars /column etc. of any description for concealing the boxes to required depth & making good the disturbed surface in CM 1:4 including finishing the surface to match with the existing surface. (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'. (iii) The quoted rates shall be deemed to be inclusive for provision of concealed flush terminal metal box, any module white frame, top cover and connected accesories
(a) One light point controlled by one way one switch SP 5 Amps ,240 V.
(c) One ceiling/exhaust fan point controlled by one way one switch SP 5 Amps, 240 V.
(d) One switch socket outlet 3 Pin, 5 Amps, SP on independent board.
(e) One switch socket outlet 3 Pin, 5 Amps, SP on same board.
All as per the above item No 4 herein before but with 2.5 Sqmm cable for 3 Pin 5/15 Amps switch socket outlet.
S&F modular switch one way 6 Amps , 1 module type complete .
S& F modular socket , 6 Amps , 2/3 pin combined 2 module complete.
S& F modular switch 16 Amps , 1 module complete.
S& F modular socket combination, 6 Amps / 16 Amps , 2/3 pin combined 2 module complete.
S&F ceiling rose surface backlite 65 x 20mm size three terminal ISI marked complete
S&F Bell push 6 Amps 1 module complete
S&F bell Multi music type , 240 Volt , Single Pole ISI marked complete.
Supply and fixing LED lights fitting 1x 20 W, 220V,AC decorative box type with driver, holder including LED tube light connecting upto PVC insulated 3 core flexible cable from ceiling rose to fitting drawn through in PVC flexible conduit including as per site requirement and 2 Nos of round or square PVC bolck for fixing of FTL fitting complete all as per directed by Engr-in-charge.
Supply and fixing LED ceiling lights fitting 600mmx600mm, 36 watt complete with driver box type with driver, complete all as per directed by Engr-in-charge.
Supply and fixing of mirror light of capacity 1x10 Watt epoxy white powder coated CRCA sheet steel housing with acrylic diffuser gaskat with all fixing acessories complete all as specified and directed.
supply & fixing modular fan regulator step type , 2 module complete.
M&L for sub main wiring with four runs of 6 Sqmm (4x6 sqmm )1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductorcable confirming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia ISI marked with all conduit accessories concealed in walls/roofs/floors etc with one run of 6 Sqmm (1x6 sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire complete all as specified and directed. Note:- 4 runs of 6 Sqmm ,one run of 6 Sqmm ( 4x6 sqmm + 1x6 sqmm ) cable and one meter of conduit will be measured as one unit again.
M&L for sub main wiring with two runs of 6 Sqmm (2x6 sqmm )1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductorcable confirming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia ISI marked with all conduit accessories concealed in walls/roofs/floors etc with one run of 6 Sqmm (1x64 sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire complete all as specified and directed. Note:- 2 runs of 6 Sqmm ,one run of 6 Sqmm ( 2x6 sqmm + 1x6 sqmm ) cable and one meter of conduit will be measured as one unit again.
Supply & fixing MCB DBs TPN vertical, Double door, with provision of MCCB as incommer , 4 way, flush in wall, including civil work to match the disturbed surface with existing complete all as specified and directed by Engr-in-charge
S&F sheet metal enclosures for distribution board when MCB to be used TPN ( Triple pole and neutral ) 4 way, 415Volts, sheet metal powder coated, IP 42 protection with 200 Amps rated bus bar, double door type complete all as specified and directed.
S&F sheet metal enclosures for distribution board when MCB to be used SPN ( Single pole and neutral ) 12 way, 240 Volts, sheet metal powder coated, IP 42 protection with 200 Amps rated bus bar, double door type complete all as specified and directed.
S&F sheet metal enclosures for distribution board when MCB to be used SPN ( Single pole and neutral ) 8 way, 240 Volts, sheet metal powder coated, IP 42 protection with 200 Amps rated bus bar, double door type complete all as specified and directed.
S&F MCCB of capacity 100 Amps , 415 Volts, rupturing capacity 16 KA complete.
S&F MCB TP, 63 Amps, 415 Volts, rupturing capacity 10 KA."B" Series complete.
S&F MCB SPN, 63 Amps, 240 Volts, rupturing capacity 10 KA."B" Series complete.
S&F MCB SP, 5 to 32 Amps, 240 Volts, rupturing capacity 10 KA "C" Series complete.
Supply & fix RCBOs double pole 63 A for earth leakage, overload & short- circuit protection 30 mA complete.
supply and fix AC surge protection device, one pole & neutral, Voltage 240V DIN rail mounted,electrical conncetion with suitable rating copper wire complete all as specified and directed by Engr-in-charge.
supply and fixing under voltage & over voltage protection ,DIN rail mounted,single phase electrical conncetion with suitable rating copper wirecomplete all as specified and directed by Engr-in-charge.
M&L , earthing complete for machinary / Equipment installed at power house / sub station with galavanised steel earth plate electrode of size 60 cmx 60 cmx 6 mm thick buried directly in ground ( earth pit not less then 2.25 m deep below the normal ground level ) with top edge of the earth plate not less then 1.5m below normal Ground level connected galvanised earth lead wire 4.0mm dia by means of bolts, nuts, washerws and check nuts all shown in electrical plate No.5 of SSR Part- I connected to main board / disribution board complete .Earthing GI lead and GI protection pipe 15 mm dia light grade upto 7.5 m from earth pit connecting to machinary/ equipment, testing point, all as specified and testing on completion all as per directed.
Note :- (i) The unit rate shall also included for earth work in hard /dense soil , PCC type C-I (1:3:6) chamber , PCC 1:2:4 type B-I cover 50 mm thick reinforced with 8 mm dia TMT bars,150 mm c/c both ways, funnel with watering pipe 20 mm dia medium graded , GI protection pipe light grade 15 mm dia and wire mesh complete in addition to items No. 1(a) to (e) of preamble (notes) under sub heading earthing specified on SI page No. 389 of SSR Part - II.
(ii) Earthing lead and GI protection pipe beyond 7.5 mtrs will be measured and paid separatelly if required under appropriate Schedule.
Note :- (i) Earthing shall be tested as specified in casul 19.137 of SSP PART - I 2009 , to the entire satisfication of Engr-in-Charge. (ii) On teting after complataion of earthing , if the desired earth resistance is not obatined the earthing wiil be re done by the contractor at his on risk and cost to the entire satisfaction of the Engr - in - charge.
S&f angle holder backlite with 1x11 Watt LED Bulb with fixed on hylum sheet including all fixing acessories and making of connection with twin core flexible copper conductor from ceiling rose to fitting complete all as specified and directed.
Taking down celing fan /exhaust fan for refixing after painting , overhauling including greasing oiling etc complete.
Hanging only repaired celing fan /exhaust fan after painting , overhauling , greasing and replacement of U/S componante to make functional including provision of 3 core flexible copper conductor from ceiling rose to fan complete all as specified and directed .
Supply and fix in replacement XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross sectional area 70 sqmm 3.5 core complete all as specified and directed
Excavation in trenches in soft/loose soil , not.exc 1.5 mtr wide and not.exc 1.5 mtr deep and getting out in soft/loose soil for laying of cable/foundation of pole and stay etc in complete as sepecified.
Returning filling including spreading, levelling, watering and well ramming in layers n.exc 25 cm.
Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above ground level from starting point.
M&L for sand cushioning in trenches for protection of LT under ground cable including watering and consolidation.
Supplying and laying un-reinforced precast concrete cable cover class LV Type 1, flat, size 250mm x 150mm x 40mm complete.
Supply and laying GI tube light grade 40 mm bore complete.
Supply and lay pipe uPVC pipe including fittings of size 50 mm (2.0") dia complete all as specified and directed
Supply and lay pipe uPVC pipe including fittings of size 25 mm (1.0") dia complete all as specified and directed
M&L for cutting of existing DI/CI pipe line in position for rectifying leakage and reducing to required length, in position, for insertion of collars or other fittings including necessory exvation and earthwork, dewatering etc,if any involed, complete all as specified and directed for 50 / 100 mm bore of pipes
supply and fix ball valve 25 mm dia including all fittings all as specfied and directed
M&L for point wiring for One light/fan/exhaust fan/buzzer point controlled by one,one way switch with using 1.5 Sqmm (nominal sectional area) multi stranded copper conductor, single core, FRLS PVC insulated & unsheathed cable, 1100 volts grade with and including pVC casing and caping of adequate size fixed on surface with PVC rawl plugs with and including wooden box/sunken type pressed steel terminal boxes of required size of not less than 1.6 mm thick factory made and factory painted with top cover 3mm thick plastic laminated sheet fixed with brass screw and washer with all accessories including single core multi-stranded copper conductor 1.5 sqmm size PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same conduit/casing capping complete NOTE :- (i) Quoted rate shall be deemed to include the cost of cutting chases in walls / pillars /column etc. of any description for concealing the boxes to required depth & making good the disturbed surface in CM 1:4 including finishing the surface to match with the existing surface. (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'. (iii) The quoted rates shall be deemed to be inclusive for provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick laminated sheet fixed with suitable brass screws and cup washers
(a) One light point controlled by one; one way switch.
(b) One fan/exhaust fan point controlled by one, one way switch.
(c) One 3 pin socket out let 5 amp point on the independent board
(c) One 3 pin socket out let 5 amp point on the same board
(d) but with 2.5sq mm size FRLS pvc insulated and unsheathed 1100 volts grade single core stranded (multistrand) copper conductor cable for 3 pin socket outlet 15 amp on independent board.
S&F ceiling rose, surface bakelite, 65X20mm three terminal complete all as specified and directed
S&F switch piano flush button single pole230 / 250 volts one way 5 Amps complete all as specified and directed
S&F socket outlet five pin, 5 Amps, flush type, 230 volts AC circuit complete all as specified and directed. Make: Anchor / Havells / Legrand
S&F switch socket outlet combination, multipurpose, three pin, 15 Amps & three pin 5 Amps controlled by one switch , flush type, 230 volts AC circuit complete all as specified and directed. Make: Anchor / Legrand / Havells
S&F fan regulator electronic, step type, suitable for ceiling fans of any capacity, pre-wired 230 volts AC 50Hz supply 100Watt complete all as specified and directed.
supplying, installing, commissioning and testing of inverter type split air conditioning unit 1.5 Ton indoor / outdoor complete with cordless remote control unit ,High ambient cooling,Adjustable mode and stabliliser free operation with inbuilt with BEE 5 star rating inverter type with CFC refrigerant 1.5 tonne capacity complete and comprising of the following :- a) Refrigerant copper pipe of suction and discharge line with insulation over pipe , condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safety accessories including complete wiring for evaporator & condensing unit with fixing of suitable size of copper cable,b) fixing outdoor unit at suitable unit and supply of bracket of 2 nos for holding outdooer unit and make odd the disturbed surface to match with the existing surface after pluging the holes complete all as specified and directed.
supply and fix Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole SP MCB 20A all as specfied and directed
supply and fix double door SPN DB 8 way all as specfied and directed
supply and fixing MCB SP 63 amps in c series having current rating 10KA complete all as psecfied and directed
supply and fixing MCB SP 32 amps in c series having current rating 10KA complete all as psecfied and directed
supply and fixing MCB SP 6 to 16 amps in c series having current rating 10KA complete all as psecfied and directed
Supply and lay in trench/wall fixing with GI clamp including suitable size casing caping of XLPE 2 core cable of size 16 sqmm all as specfied and directed.
Supply and lay in terench/ wall fixing with GI clamp including suitable size casing caping of XLPE 2 core cable of size 10 sqmm all as specfied and directed.
M/L for Sub main wiring with 2 runs of PVC insulated unsheathed multi stranded single core copper conducter 4 Sqmm drawn through PVC conduit/casing capping including accessaries with 2.5 sqmm PVC insulated earth wire fixed to the existing wall with saddles, screws etc after removing the unserviceable wiring and connecting up ,all as directed. Note: 2 runs of cable and one run earth wire and conduit/Casing & Caping will be measured as one length.
M&L for earthing with copper earth p;late electrode 600mm x600mmx 3.15mm buried direclty in ground vertically to a depth not less than 2.25 metre below ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to copper earth strip 20 x 3mm, (main earthing lead) by means of galvanized bolts, bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
Supply and fix continuity conductor or nain rarthing lead fixed to wall on batten or reces or chases or burued in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as requied 20 x3 mm copper earth strip complete all as specified adn directed.
Supply and fix Anti static flooring of thickness 2 mm width of 2.5 mtr and length of 2.5 mtr complete all as specified and directed.
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of 2.5 % and of capacity 3000VA including fix volatge stablizer to wall with necessary sheet and support all as specfied and directed.
Supply, installation, testing and comissioning 75KVA , 415/415V (fixed ratio), 3 phase, 50 Hz, ONAN cooled oil immersed double copper wound outdoor type isolation transformer complete with first filling of IS: 335 ISI marked filtered & dehydrated transformer oil electrostatic shield between primary &secondary winding and other standard fittings / accessories delta on 415V side and star on 415 V with vector group DYN-II including overload and undercurrent protection, surge protection as per ANSI/IEEE standards C62.41,1991 (IEEE,587 Category A and B) IEC 1000-4 and 1000-5, operating temperature upto 60°C, operating humidity 95% relative (non condensing), efficiency 98%, PCC foundation above ground lever as per manufaturer Drg or as directed by EIC, mounting on wheels including locking arrangement, bypass arrangement with bypass switch, Earth to neutral voltage should be less than one volt complete all as specified and directed by EIC.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc for laying of cables, erection of poles, struts/ stays etc not exceeding 10 sqm on plan and getting out in soft loose soil.
Returning, filling in, including spreading leveling watering and well ramming in layers not exceeding 25 cm in any type of soil.
Removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in soils.
M & L for sand filling in trenches for cushioning of LT cables punning after filling complete as specified and as directed. Note: Punned thickness shall only be measured and paid
Supply and lay un-reinforced precast concrete cable cover , class , LV , Type I flat size 250 x 150 x 40 mm laid dry in treches over under ground cables.
S & F GI pipe, light grade, of size 50 mm dia including necessary fittings laid in trenches/fixed on wall/pole for LT cable protection and taking down the old GI pipe, complete all as speicifed and directed for cable protection .
NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor.
OM SREE MAHADEV TRADERS
M/s Bombay Novelty Stores
JYOTI TRADERS
machine vision plus
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .