Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 CrAccepted-AOC | ₹7.8 Cr | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹8.7 Cr+₹88.5 L (11.4%)Rejected-Finance | ₹8.7 Cr+₹88.5 L (11.4%) | L2 | Rejected-Finance L2 Bidder |
| 3 | Rejected-Technical FLAT NO 104 1ST FLOOR MALATI MANSION NILADRI VIHAR CHANDRASEKHARPUR BHUBANESWAR ODISHA PIN 751021 | KHORDHA | ODISHA | 751021 | - | - | Rejected-Technical Technically not qualified |
Tender Value
Refer Docs
EMD Value
₹19.5 L
Closing Date
20 Jul 2022, 5:00 pmClosed
Executive Engineer, PCM-Dakpathar
Executive Engineer, Project Civil Maintenance-Dakpathar, District- Dehradun.
Treatment of Hill Slope behind the intake of Ichari Dam
2022_UJWB4_45723_1
NCB/06/EE/PCM-DKP/TN/2022-23
Open Tender
Civil Works
Item Rate
547 days
Ichari
Please refer Tender documents.
3 documents required · 3 mandatory
₹23,600
UJVN Ltd., P.N.B. A/c No 0639002100009390
₹19.5 L
Dakpathar
8 May 2023
16 Jun 2022
21 Jul 2022
16 Jun 2022
20 Jul 2022
5 Jul 2022
17 Jun 2022 - 30 Jun 2022
28 Jun 2022
Amount
Excavation in foundation for retaining, breast walls etc, in all types of soils and rocks including all lead, lift and disposal of surplus material as per direction of engineer - in - charge, as per drawing and technical specifications Clause 305.1 of MORD Specifiction
Slip clearance (by manual means) of loose earth and other small loose materials including disposal complete as directed by the Engineer-in-charge.
Cement plum Masonry with 40% plum & 60% 1:3:6 cement concrete including supply of all material, labour, T&P etc. required for proper completion of the work. as per drawings and technical specifications Clause 802, 803, 1202 & 1203 of MORD Specification
Centring and shuttering including strutting, ropping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Providing, drilling, grouting, threading of Anchors (32mm dia, avg. yield strength - 560 N/mm2){(TMT(Fe-500)} including grouting for full length of the drilled hole, all anchor bars, nuts, and base plates epoxy coated, complete, as per site requirement including all cost labour, material and T&P etc. required for proper completion of the work.
Drilling, Supply & installation of PVC Weep hole pipe 90mm dia, drilling by wogan drill or rock rill 120mm dia including cost of PVC Pipe filter media geotextile, labour T&P etc required for proper completion of work as per direction of Engineer-in-Charge including cartage, all labour, material and T&P etc. required for proper completion of the work.
Supply of 9mm thick Cementitous Composite Geotex Carpet (CCGC), including cost of labour, material, transportation and T&P etc. required for proper completion of work as per direction of Engineer-in-Charge.
Laying and fixing of 9mm thick Cementitous Composite Geotex Carpet (CCGC), including cost of hardware for fixing, labour, material, transportation upto the hill above the intake of Ichari Dam and T&P etc. required for proper completion of work as per direction of Engineer-in-Charge.
Supply and Installation of Rock Fall Barrier/Debris flow Barrier system kit of type, Capacity : 2000 KJ, Post to Post Distance – 10m, Height of Barrier – 4m, 4 nos. Sections each of 10m Length, comprising of Ring Nets and Double Twisted hexagonal Mesh including all accessories like u clamps, thimbles, anchorages etc. complete and as per technical specifications, as per direction of Engineer-in-Charge including cartage, all labour, material and T&P etc. required for proper completion of the work.
Supply and Installation of Rock Fall Barrier system kit of type, Capacity : 3000 KJ, Post to Post Distance – 10m, Height of Barrier – 6m, 3 Sections each of 10m Length as per direction of Engineer-in-Charge including cartage, all labour, material and T&P etc. required for proper completion of the work.
Providing and fixing G.I chain link fabric fencing of required width in mesh size 50x50mm including strengthening with 2mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-Charge. as per direction of Engineer-in-Charge including cartage, all labour, material and T&P etc. required for proper completion of the work. Made of G.I. wire of dia 4mm
Disposal of rubbish/Debris outside the nigam's area as per direction of Engineer-in-Charge including cartage, all labour, material and T&P etc. required for proper completion of the work.
Attending minor type of repair etc. for full day by engaging and supplying one suitable Beldar/mazdoor/sweeper for carrying simple type of repairing /cleaning of all work including all T&P etc. complete but excluding cost of material.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer for miscellaneous works of catwalk way, approach stair etc. all complete:
Providing and fixing double scaffolding system (cup lock type) on the exterior side of structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note: - (1) The elevational area of the scaffolding shall be measured for payment purpose.(2) The payment will be made once only for execution of all items for such works.
Supply and installation of Rhomboidal Wire Rope Panels of rope diameter 10mm with steel core with the intersection of joints secured by a double knot connection having minimum tear capacity of 15 kN and mesh opening 400 x 400mm size including the Top and Bottom support Rope, lacing wire or rope required to connect the panels and all accessories such as U clamps, thimbles as shown in drawings and as per technical specifications etc. complete including all lead, lift and machinery.
Supply and installation of Double Twist Wire Mesh Bi Oriented composite with spacing of longitudinal and transversal steel wire ropes at 1.5m interval including the Top and Bottom support ropes, lacing wire or rope required to connect the nets and all accessories such as U clamps, thimbles as shown in drawings and as per technical specifications, etc. complete including all lead, lift and machinery.
Alliance Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .