Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹36.6 LAccepted-AOC | ₹36.6 L Quoted ₹38.3 L | 1 | Accepted-AOC AOC |
| 2 | 2₹42.1 L+₹3.8 L (9.87%)Rejected-Finance B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | ₹42.1 L+₹3.8 L (9.87%) | 2 | Rejected-Finance NOT L1 |
| 3 | 3₹42.4 L+₹4.1 L (10.7%)Rejected-Finance WANIAWAD BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | ₹42.4 L+₹4.1 L (10.7%) | 3 | Rejected-Finance NOT L1 |
| 4 | 4₹43.0 L+₹4.7 L (12.1%)Rejected-AOC FLAT NO 93 POCKET 03 SECTOR 11 DWARKA NEW DELHI 110 075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | ₹43.0 L+₹4.7 L (12.1%) | 4 | Rejected-AOC NOT L1 |
| 5 | 5₹45.3 L+₹7.0 L (18.2%)Rejected-Finance | ₹45.3 L+₹7.0 L (18.2%) | 5 | Rejected-Finance NOT L1 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
16 Feb 2022, 6:00 pmClosed
GE ARMY BHUJ
GE ARMY BHUJ
SPECIAL REPAIRES TO LT EXTERNAL ELECTRIFICATION WORKS AT GANDHIDHAM AND BHUJ MIL STN UNDER GE(A) BHUJ
2022_MES_498863_2
8878
Open Tender
Civil Works - Others
Item Rate
180 days
ARMY AREA BHUJ AND GANDHIDHAM
REFER TENDER
6 documents required · 6 mandatory
₹500
GE ARMY BHUJ
₹98,000
Yes
8 Apr 2022
27 Jan 2022
17 Feb 2022
27 Jan 2022
16 Feb 2022
4 Feb 2022
Amount
S & F GI pipe, light grade, of size 40 mm dia including necessary fittings laid in trenches/fixed on wall/pole for LT cable protection and taking down the old GI pipe, complete all as speicifed and directed for cable protection .
S & F GI pipe, light grade, of size 80 mm dia including necessary fittings laid in trenches/fixed on wall/pole for LT cable protection and taking down the old GI pipe, complete all as speicifed and directed for cable protection .
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc for laying of cables, erection of poles, struts/ stays etc not exceeding 10 sqm on plan and getting out in soft loose soil.
Returning, filling in, including spreading leveling watering and well ramming in layers not exceeding 25 cm in any type of soil.
Removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in soils.
M & L for sand filling in trenches for cushioning of LT cables punning after filling complete as specified and as directed. Note: Punned thickness shall only be measured and paid
Supply and lay un-reinforced precast concrete cable cover , class , LV , Type I flat size 250 x 150 x 40 mm laid dry in treches over under ground cables.
Disconnecting, taking out, removing old existing unserviceable LT underground cable any size complete all as specified and directed .
Supplying ,Laying, jointing and testing new XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed of size 3.5 core 120 sqmm :-.
- do- as per Item 08 here in above but of size 3.5 core 95 Sqmm
- do- as per Item 08 here in above but of size 3.5 core 70 Sqmm
- do- as per Item 08 here in above but of size 3.5 core 35 Sqmm
- do- as per Item 08 here in above but of size 4 core 25 Sqmm
- do- as per Item 08 here in above but of size 4 core 10 Sqmm
- do- as per Item 08 here in above but of size 2 core 10 Sqmm
Disconnecting, taking out, removing old existing unserviceable LT underground cable and Supplying ,Laying, jointing and testing new XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed of size 2 core 10 sqmm :-.
- do- as per Item 14.01 here in above but of size 4 core 25 Sqmm
- do- as per Item 14.01 here in above but of size 3.5 core 95 Sqmm
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed by Accepting officer.
M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron strip as earthing lead of dia 32 x 6mm by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’ NOTE - The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, RCC 1:2:4 type B1 cover 50mm thick reinforced with 8mm dia TMT bars @ 150mm C/C both ways, funnel with watering pipe
(a) Copper Bus Bar 250 A rating for 3 Phase and 200 A for Neutral - 01 Set
(b) Digital Voltmeter 0 to 500 V
(d) LED Indication Lamp for 3 Phase - 01 Set
(e) MCCB 4 Pole 160 Amps 36 KA - 01 Nos (01 No for Incoming)
(f) MCCB 4 Pole 63 Amps 16 KA - 04 Nos ( for Outgoing )
(a) Copper Bus Bar 250 A rating for 3 Phase and 200 A for Neutral - 01 Set
(b) Digital Voltmeter 0 to 500 V
(d) LED Indication Lamp for 3 Phase - 01 Set
(e) MCCB 4 Pole 160 Amps 36 KA - 01 Nos (01 No for Incoming)
(f) MCCB 4 Pole 63 Amps 16 KA - 02 Nos (outgoing)
(g) MCB SPN 32 Amps - 02 Nos (outgoing)
(h) MCB SPN 16 Amps - 02 Nos ( Outgoing)
(i) MCB TPN 32 Amps -01 Nos (street light timer)
(a) Copper Bus Bar 400 A rating for 3 Phase and 200 A for Neutral - 01 Set
(b) Digital Voltmeter 0 to 500 V
(d) LED Indication Lamp for 3 Phase - 01 Set
(e) MCCB 4 Pole 250 Amps 36 KA - 01 Nos (01 No for Incoming)
(f) MCCB 4 Pole 100 Amps 16 KA - 02 Nos (outgoing)
(g) MCCB 4 Pole 63 Amps 16 KA - 03 Nos (outgoing)
(a) Copper Bus Bar 150 A rating for 3 Phase and 200 A for Neutral - 01 Set
(b) Digital Voltmeter 0 to 500 V
(d) LED Indication Lamp for 3 Phase - 01 Set
(e) MCCB 4 Pole 100 Amps 16 KA - 01 Nos (01 No for Incoming)
(f) MCCB 4 Pole 63 Amps 16 KA - 01 Nos (outgoing)
(g) MCB TPN 32 Amps - 01 Nos
(h) MCB SPN 32 Amps - 02 Nos
(a) Copper Bus Bar 400 A rating for 3 Phase and 200 A for Neutral - 01 Set
(b) Digital Voltmeter 0 to 500 V
(d) LED Indication Lamp for 3 Phase - 01 Set
(e) MCCB 4 Pole 250 Amps 36 KA - 01 Nos (01 No for Incoming)
(f) MCCB 4 Pole 63 Amps 16 KA - 05 Nos (outgoing)
(g) MCB SPN 32 Amps - 02 Nos
(h) MCB SPN 10 Amps - 01 Nos
(a) Copper Bus Bar 600 A rating for 3 Phase and 200 A for Neutral - 01 Set
(b) Digital Voltmeter 0 to 500 V
(d) LED Indication Lamp for 3 Phase - 01 Set
(e) MCCB 4 Pole 350 Amps 36 KA - 01 Nos (01 No for Incoming)
(f) MCCB 4 Pole 63 Amps 16 KA - 01 Nos ( for Outgoing )
(g) MCCB 4 Pole 100 Amps 16 KA - 01 Nos ( for Outgoing )
(h) MCCB 4 Pole 250 Amps 36 KA - 01 Nos ( for Outgoing )
(i) MCB TPN 32 Amps -02 Nos (for outgoing)
(a) Copper Bus Bar 100 A rating for 3 Phase and 200 A for Neutral - 01 Set
(b) Digital Voltmeter 0 to 500 V
(d) LED Indication Lamp for 3 Phase - 01 Set
(e) MCCB 4 Pole 63 Amps 16 KA - 01 Nos (01 No for Incoming)
(f) MCB TPN 32 Amps -03 Nos (for outgoing)
(g) MCB SPN 16 Amps - 01 Nos (outgoing)
(a) Copper Bus Bar 300 A rating for 3 Phase and 200 A for Neutral - 01 Set
(b) Digital Voltmeter 0 to 500 V
(d) LED Indication Lamp for 3 Phase - 01 Set
(e) MCCB 4 Pole 200 Amps 36 KA - 01 Nos (01 No for Incoming)
(f) MCCB 4 Pole 63 Amps 16 KA - 05 Nos ( for Outgoing )
Dismantling cross arms of MS channels or angle sections etc complete
Dismantling of insulators any type and any size complete
Dismantling of ACSR of AAC conductors
Supply, fix and testing of automatic street light Digital type of capacity 5 KW equally distributed, three phase with high and low voltage and overload protection consists of 3Nos of contactors, 3 Nos ofincoming MCbs & 3 nos of outgoing MCBs of 16-20 Amps Each & circuit wiring of 10 sqmm. Required illuminance level for swicthing ON is less than or equal to 30 Lux and for swicthing OFF greater than or equal to 10 Lux. The circuit should also have provision for manual operation. sensor along with contactor,MCBs should be enclosed in polemounted enclosure made of rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP 54 complete all as specified and directed .
Supply and fix wiring along with earth wire single core of size 2 x 1.5 sqmm + 1 x 1.0 sqmm earth wire of FR grade PVC insulated enclosed in PVC conduit pipe of suitable dia fitted with suitable clamps complete all as specified and directed.
Supply and fix in repairs Weather Proof PVC Junction Box made out of not less than 2 mm thick of size 250x200x100 mm (approx) complete with hinged door locking arrangement and consisting of 01 No panel mounted connector 4 pole 32 A - 01 No MCB TPN 16 Amps 10 KA - 01 No incl 02 Nos Cable Glands suitable for inserting cable not less than 50 sqmm with 02 No 01 mm GI plate (150x50mm) having two holes as per the size of cable glands, fixed with cable gland for earth connectivity confirming to IP 65 complete including fixing on street light pole with MS Clamps, bolts, nuts and washers all as specified and directed by Engr-in-Charge.
Supply, installation, testing and commissioning weather and vermin proof L.T. feeder pillar box (Main feeder pillar) factory fabricated CPRI appvoved indoor cubicle/KIOSK type totally enclosed made out of 3.15 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation and aluminium bus bar for 3 phase & neutral mounted on epoxy insulator-01 Set including connecting the following (Main feed pillar box)
(a) Copper bus bar, 300 amps TPN -01 set
(b) MCCB, 4 pole 200 amps, 35 KA - 01 (incoming).
(c) MCCB 4 Pole 25 amps 16 KA - 11 , (01 Spare)
(d) MCB SPN 16 Amps - 01
(d) MDB SPN 32 Amps - 01
(g) Indicating lamps ( LED type) ( R-Y-B) -01 (Set of three)
(k) Change Over switch On Load 4 pole 200amps.
Supply , installation, commissioning and testing MCB Distribution board vertical type TPN double door, for mounting DP/ SP/TP MCBs as Incoming / outgoing, factory made, confirming to IS, fabricated out of CRCA sheet , fitted with DIN channel, neutral link and suitable rated bus bar, DBs shall be semi glossy finished with epoxy polyester based powder paint sprayed and backed at high temperature, between powder paint process the sheet steel having to go through the anti rust conditioning in not less than seven tank process to ensure smooth finish and protection against corrosion atmosphere. The DBs shall be double door type with hinged door with locking arrangement. The DP/SP/TP MCB shall be of same make as DB. DB shall also be provided with label marking indicating the incoming and outgoing circuits on all way as specified. The DBs shall be of IP 43 - IK 09 with metal door complete all as specified and directed for DB TPN 4 way.
Supply and fixing 415V, 10 KA 'C' curve miniature circuit breaker (MCB) city TPN 40 AMP, in the MCB DB Complete with connection testing and commissioning.
Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning.
M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth wire 4.0 mm by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to LT Panel Board with & including adequate quantity of charcoal dust and common salt alround earth plate & 20 mm dia GI pipe light grade for earth strip protection for suitable length and GI pipe 15 mm dia light grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed. NOTE: (i) Earth strip and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule. (ii) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, RCC 1:2:4 type B1 cover 50mm thick reinforced with 8mm dia TMT bars @ 150mm C/C both ways, funnel with watering pipe
Abhishek Enterprises
M/s Bombay Novelty Stores
M/S PRADEEP ENTERPRISES
Ashok Electric and Electronics
Pelectricals
zotabrothers
ALBA AC AND REF SERVICES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .