Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.0 LAccepted-AOC | ₹1.0 L | 1 | Accepted-AOC LOWEST |
| 2 | 2₹1.2 LRejected-Finance AROOR P O ALAPPUZHA KERALA 688534 | ALAPPUZHA | ALAPPUZHA | KERALA | 688534 | ₹1.2 L | 2 | Rejected-Finance 2 |
| 3 | 2₹1.2 LRejected-Finance | ₹1.2 L | 2 | Rejected-Finance 2 |
Tender Value
₹1.5 L
EMD Value
₹3,093
Closing Date
9 Feb 2026, 6:00 pmClosed
SECRETARY NANNAMBRA GP
SECRETARY NANNAMBRA GP
MINIMAST LIGHT INSTALLATION IN WARD 9
2026_DP_831158_1
3977093/142
Open Tender
Miscellaneous Services
NANNAMBRA GP WARD 9
Please refer Tender documents.
5 documents required · 5 mandatory
₹555
₹3,093
24 Jun 2026
27 Jan 2026
11 Feb 2026
27 Jan 2026
9 Feb 2026
27 Jan 2026
Electrification
90.15.1.1:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters
90.15.4.8:Supply Conveyance, installation, testing and commissioning of 120W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
OD193778/2025-2026:Steel reinforcement for RCC Work including straightening, cutting, bending, placing in position and binding all complete
90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
OD193783/2025-2026:Supply Conveyance, installation, testing and commissioning of g 25A, 2Pole, AC 1 rated power contactor with 1NO+1NC auxiliary contacts & with AC coil
OD193771/2025-2026:Supply Conveyance, installation, testing and commissioning of 24 Hours Analog Timer for operating automatic ON-OFF function
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD193776/2025-2026:Supply, providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthling system
OD193775/2025-2026:Supplying and Providing and fixing 25 mm X 3mm G.I. strip earth lead from the test joint to the earth plate
OD193774/2025-2026:Supplying and fixing 32 A, 2 Way neutral links mounted on DMC/SMC base with connections, in existing meter board
OD193779/2025-2026:Supplying and fixing 32A, HRC Fuse with HRC Fuse link with connections, in existing meter board
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
OD193770/2025-2026:Supplying and Fixing DIN rail inside the existing MCB DB/ Panel/Meter board etc
OD193768/2025-2026:Supply and installation of dust and vermin proof sintex box ( MB 3425) and to fix kseb meters, fuse unit, CTs, etc as required , including fixing it on existing concrete pillar. Giving connection as required
OD193769/2025-2026:Supply and installation of dust and vermin proof sintex box (3425) and to fix MCB and isolator etc. as required , including fixing it on existing concrete pillar. Giving connection as required.
OD193772/2025-2026:Supply,Conveyance and fixing the following size of GI pipe along with painting 2 coats of synthetic enamel paint over a coat of synthetic enamal paint over a coat of zinc chromate primer etc as required 40 mm dia GI pipe (medium class )
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD193781/2025-2026:Supply , laying and joining of 32 mm or nearest size green flexible PVC Pipe for Submersible Pumps Approved make specials as delivery pipe using required leak proofing materials etc. as required
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
OD193773/2025-2026:Charges for preparation of KSEB test Report for submitting to the concerned KSEB section office
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1396463.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.06 MB
BOQ_1396463.xls
BOQ • 0.34 MB
142viewsbd.pdf
Tender Documents • 1.63 MB
Download all tender documents and submit your bid