Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 2ND FLOOR KALOOR BUSSTAND COMPLEX BUS STAND COMPLEX KALOOR BUSSTAND COMPLEX ERNAKULAM KERALA 682017 | ERNAKULAM | KERALA | 682017 | Admitted-Finance |
| 2 | Rejected-Technical 41 1294 A6 SECOND FLOOR BEEVI COMPLEX C P UMMER ROAD KOCHI ERNAKULAM KERALA 682035 | ERNAKULAM | KERALA | 682035 | Rejected-Technical The firm does not meet the pre-qualification criteria |
Tender Value
Refer Docs
Closing Date
1 Jan 2025, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DGM (SRM)
Ship Repair Materials Department Cochin Shipyard LTD Perumanoor PO
WATCHKEEPING PANEL SYSTEM JOBS (RM.0807)
2024_CSL_221457_1
CSL/SR1/GePNIC/41475/VKD437
Open Tender
Marine Services
Works
60 days
Karwar/CSL/Cochinport
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
14 Jan 2025
26 Dec 2024
2 Jan 2025
26 Dec 2024
1 Jan 2025
26 Dec 2024
26 Dec 2024 - 1 Jan 2025
Amount
Watchkeeping Panel(SERVICE COST)
Refurbishment of main watchkeeper control post in PDCR (Machinery Control Room), Forward and AFt ERCR (Engine Control Room) and Fuel control panels (PUNS). Job Involves: - (a) Renewal SCADA system in PDCR and SPDCR with additional critical data input of all TD Aux, MD auxiliaries, RO plant, Ref plant, HP Air Compressor, DG (RPM, Vacuum, Salinity, Lub oil pressure, Discharge pressure, level etc) (b) Renewal of power supply and commmunication cabling from field to PDCR & SPDCR (1X5 core wire, L 3000 mtr), (OFC L 500 mtr) (c) Renewal of HMI panel with pop up window of all critical parameters/alarm (d) Renewal of all components i.e SMPS, relay and indicator lights as suitable (red/ green/ yellow) Qty-15 each 1.52.1 Removal of the existing panels (Panel Casing). 1.52.2 Gauging of requirement & renewal of Panels. 1.52.3 Light indications for critical instrumentations. 1.52.4 Servicebility checks of all panel indications, electrical. wiring and instrumentation.
TD System (SERVICE COST)
Tachogenerators and RPM indicators of TD auxiliaries (TGs, TDAC, Vertical aux) Job Involves : - (a) Supply and Renewal of Tachogenerator, Matching Module and Voltmewter/ammeter (Qty- 12 each) (b) Calibration of Tachogenerator, Matching Module and Voltmewter/ammeter (Qty- 40 each) (c) Supply and renewal of signal amplification and converter module ( 12 set) (d) Supply and Renewal of Power supply Cable between Tachogenerator and Matching Module, Matching Module to Voltmeter/Ammeter/ PΓ panel/ I/O device (1X5 core wire, L-500 mtr) (e) Supply and renewal of analog / digital indicators with signal conversion unit .- 4nos (f) ) STW of the same post fitment including grounding.
TDAC(SERVICE COST)
1.11.5 When the service life (10000 to 12000 hours) is over, replace the following components:- 1.11.5.1. Pressure relay, type д21k1, Qty - 24 each 1.11.5.2. Electric motors, type aдh-100 and дm160mb4, Qty -04 1.11.5.3. Electric magnet, type эm33-71311, Qty - 12 each. 1.11.5.4 Voltmeter, type m1618t, Qty -10 each 1.11.5.5 Micro switch, type д-311 , Qty - 12 each . 1.11.6 Carry out calibration of feed regulator and complete flushing through of the system.1. Provsion to be made for additional RTD fitment and feed back of temperature, salinity parameters to intigrated panel in PDCR. 2. Renewal of pressure sensors(04) & RPM sensors (04) 3 Renewal of Danfoss pressure relays (24 each) 4. Renewal of voltmeter (10) 5. Renewal of limit switches (10) 6. Renewal of digital condenser level indicator (04)
TG (SERVICE COST)
SR routines of 06 TGs. (1500KW, Qty-06). Work package involves: 3.7.1 Replace the following (where applicable) 3.7.1.1 Thermo-couple 3.7.1.2 Electrical temperature indicator. 3.7.1.3 Tacho-meter transmitter. 3.7.1.4 Ball and roller bearing of pump motor. 3.195.1 Check the emergency protection for proper operation on the running turbo generator as per operating instruction. 3.195.2. Test the grounding (bonding straps) continuity of the devices, replace if necessary 3.195.3. Check all fuses and relays, replace if necessary. Lcp panel 3.195.4. Carry out calibration of each transducer/sensors and meters in the control system.
Watchkeeping Panel(MATERIAL COST)
Refurbishment of main watchkeeper control post in PDCR (Machinery Control Room), Forward and AFt ERCR (Engine Control Room) and Fuel control panels (PUNS). Job Involves: - (a) Renewal SCADA system in PDCR and SPDCR with additional critical data input of all TD Aux, MD auxiliaries, RO plant, Ref plant, HP Air Compressor, DG (RPM, Vacuum, Salinity, Lub oil pressure, Discharge pressure, level etc) (b) Renewal of power supply and commmunication cabling from field to PDCR & SPDCR (1X5 core wire, L 3000 mtr), (OFC L 500 mtr) (c) Renewal of HMI panel with pop up window of all critical parameters/alarm (d) Renewal of all components i.e SMPS, relay and indicator lights as suitable (red/ green/ yellow) Qty-15 each 1.52.1 Removal of the existing panels (Panel Casing). 1.52.2 Gauging of requirement & renewal of Panels. 1.52.3 Light indications for critical instrumentations. 1.52.4 Servicebility checks of all panel indications, electrical. wiring and instrumentation.
TD System (MATERIAL COST)
Tachogenerators and RPM indicators of TD auxiliaries (TGs, TDAC, Vertical aux) Job Involves : - (a) Supply and Renewal of Tachogenerator, Matching Module and Voltmewter/ammeter (Qty- 12 each) (b) Calibration of Tachogenerator, Matching Module and Voltmewter/ammeter (Qty- 40 each) (c) Supply and renewal of signal amplification and converter module ( 12 set) (d) Supply and Renewal of Power supply Cable between Tachogenerator and Matching Module, Matching Module to Voltmeter/Ammeter/ PΓ panel/ I/O device (1X5 core wire, L-500 mtr) (e) Supply and renewal of analog / digital indicators with signal conversion unit .- 4nos (f) ) STW of the same post fitment including grounding.
TDAC(MATERIAL COST)
1.11.5 When the service life (10000 to 12000 hours) is over, replace the following components:- 1.11.5.1. Pressure relay, type д21k1, Qty - 24 each 1.11.5.2. Electric motors, type aдh-100 and дm160mb4, Qty -04 1.11.5.3. Electric magnet, type эm33-71311, Qty - 12 each. 1.11.5.4 Voltmeter, type m1618t, Qty -10 each 1.11.5.5 Micro switch, type д-311 , Qty - 12 each . 1.11.6 Carry out calibration of feed regulator and complete flushing through of the system. 1. Provsion to be made for additional RTD fitment and feed back of temperature, salinity parameters to intigrated panel in PDCR. 2. Renewal of pressure sensors(04) & RPM sensors (04) 3 Renewal of Danfoss pressure relays (24 each) 4. Renewal of voltmeter (10) 5. Renewal of limit switches (10) 6. Renewal of digital condenser level indicator (04)
TG (MATERIAL COST)
SR routines of 06 TGs. (1500KW, Qty-06). Work package involves: 3.7.1 Replace the following (where applicable) 3.7.1.1 Thermo-couple 3.7.1.2 Electrical temperature indicator. 3.7.1.3 Tacho-meter transmitter. 3.7.1.4 Ball and roller bearing of pump motor. 3.195.1 Check the emergency protection for proper operation on the running turbo generator as per operating instruction. 3.195.2. Test the grounding (bonding straps) continuity of the devices, replace if necessary 3.195.3. Check all fuses and relays, replace if necessary. Lcp panel 3.195.4. Carry out calibration of each transducer/sensors and meters in the control system.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .