Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹52.9 CrAccepted-AOC | ₹52.9 Cr | L1 | Accepted-AOC Being Lowest Tenderer |
| 2 | L2₹54.5 CrRejected-Finance | ₹54.5 Cr | L2 | Rejected-Finance Not lowest tenderer |
| 3 | L3₹59.5 CrRejected-Finance | ₹59.5 Cr | L3 | Rejected-Finance Not lowest tenderer |
| 4 | L4₹59.5 CrRejected-Finance | ₹59.5 Cr | L4 | Rejected-Finance Not lowest tenderer |
| 5 | L5₹60.2 CrRejected-Finance 35 B BHERU VILLAS SARDAR CLUB SCHEME AIR FORCE JODHPUR 342 011 RAJASTHAN | JODHPUR | JODHPUR | RAJASTHAN | 342011 | ₹60.2 Cr | L5 | Rejected-Finance Not lowest tenderer |
Tender Value
₹52.3 Cr
EMD Value
₹15 L
Closing Date
4 Nov 2022, 6:00 pmClosed
CE (AF) GANDHINAGAR
CE (AF) CHILODA GANDHINAGAR
PROVISION OF WORK SERVICES FOR PROJECTS GHAGGAR AT AF STN BHUJ
2022_MES_557303_1
87197
Open Tender
Civil Works
730 days
GE (AF) BHUJ
AS PER NIT AND TENDERS DOCUMENTS
9 documents required · 9 mandatory
₹3,000
GE (AF) BHUJ
₹15 L
Yes
CE (AF) CHILODA GANDHINAGAR
1 Dec 2022
12 Oct 2022
5 Nov 2022
12 Oct 2022
4 Nov 2022
28 Oct 2022
13 Oct 2022 - 18 Oct 2022
20 Oct 2022
Amount
NOTE: Schedule ‘A’ Part I to XVII are under Ser No. 1.00 to 17.00. are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lump sum price worked out for Building / Structures as listed in Sch `A’ Part I.
Lump sum price worked out by the Contractor for Excavation & Earth works as listed in Sch `A’ Part II
Lump sum price worked out by the Contractor for Internal Water Supply as listed inSch `A’ Part III
Lump sum price worked out by the Contractor for Internal electrification as listed in Sch 'A' Part IV
Lump sum price worked out by the Contractor for Road/Path/Culvert/Plinth & Display board as listed in Sch 'A' Part V
Lump sum price worked out by the Contractor for Sewage Disposal as listed in Sch `A’ Part VI.
Lump sum price worked out by the Contractor for Area Drainage as listed in Sch `A’ Part VII
Lump sum price worked out by the Contractor for External Water Supply as listed in Sch `A’ Part VIII
Lump sum price worked out by the Contractor for External Electrification as listed in Sch `A’ Part IX.
Lump sum price worked out by the Contractor for Compound Wall/ Fencing with Gate as listed in Sch `A’ Part X.
Lump sum price worked out by the Contractor for Lightening Protection as listed in Sch `A’ Part XI
Lump sum price worked out by the Contractor for DG Set as listed in Sch `A’ Part XII.
Lump sum price worked out by the Contractor for EOT Crane as listed in Sch `A’ Part XIII.
Lump sum price worked out by the Contractor for Electrostatic Discharge System as listed in Sch `A’ Part XIV.
Lump sum price worked out by the Contractor for Demolition and Dismantling as listed in Sch `A’ Part XV.
Lump sum price worked out by the Contractor for Flameproof Fittings as listed in Sch `A’ Part XVI.
Lump sum price worked out by the Contractor for Protective Work for URP Building as listed in Sch `A’ Part XVII.
SCHEDULE 'A' PART - XVIII (MISC ITEMS) (Note : The contractor shall quote his rate for each of these items separately. The estimated rate is left blank since the same is not prepriced by MES)
Supply and fix gate valve (bronze) confirming to IS-9338 for size 80 mm bore with pipe flanged ends, working pressure 1.0MPA for water supply complete with all fixtures such as nut, bolts , washers all as directed by engineer in Charge.
M&L for boring, drilling, threading and tapping on existing GI mains of size 32 mm to 150 mm bore for connecting 25 to 40 mm bore pipe by fixing on clamp made out of MS flat iron of size 40 x 3 mm made to required shape & size with GI socket duly welded, nut & bolts etc. complete all as specified and directed.
M & L for Cutting the existing line up to 150mm dia and inserting Tee 150x150x80mm with connecting items complete all as specified and directed.
Supply only DI fittings like bends (any type, radius and angle) tapers any type (straight /bend, increasing, decreasing or double socket etc) Tee pieces single branch 'Y' junction, double branch cross, collars, caps & plugs for size upto 300mm bore of DI pipe complete all as specified and directed.
Material and labour for construction of valve chamber of size 1050mmx750xxx1000mm with MS sheet cover 3mm thickness along with angle iron frame of size 50 x 50 x 6mm with locking arrangement with necessary fixing materials like hinges, nut/bolts etc and painting with one coat of red oxide and two coats of bituminous black paint including excavation and earthwork in any type of soil, PCC 1:4:8 type D2 for foundation, PCC 1:2:4 typeB1 for benching, 20cm thick PCC block masonry made of PCC 1:3:6 set in CM 1:6, 10mm thick plastering in CM 1:4, pcc BED IN 1:3:6, PCC coping 1:2:4 all as shown on TD drawing CEAA/TD/57 and complete all as specified and directed.
Supply & Fix FRP juction box of size outside dimensions 400 x 300 x 190 mm including connector of 63 Amps & MCB SP 6 Amps - 01 No and fix on pole with and including MS clamps made out of 25 x 3mm MS flat iron, nut, bolts etc. complete.
Supply, fabricate, test and commissioning of LT electrical out door distribution panel board(CPRI Approved) floor mounted cubical type dust proof, weather proof, vermin proof, astehically designed, having at least IP-54 degree of ingress protection, fabricated from 3.15 mm thick CRCA sheet with front and rear opening including bus bar chamber, continuous GI strip earth bus bar 4 strips of Copper bus bar minimum 250 Amps capacity having suitable size cross sectional area, insulated color sleeves, procelain/epoxy insulators, rail channels cable alloy, danger notice board including provision of angle iron frame of size 40 x 40 x 6mm, 30 cm grouted in ground floor and 30 cm above GL duly painted including necessary excavation, foundation, PCC etc complete with locking arrangement duly powder coated of approved color connecting incoming & outgoing cable connection with suitable lugs, nuts, bolts, washers and cable joints, prewired complete with PVC insulated fire retardant copper conductor cable complete The panel shall be comprising of the following:-
Supply, fabricate, test and commissioning of LT electrical out door distribution panel board(CPRI Approved) floor mounted cubical type dust proof, weather proof, vermin proof, astehically designed, having at least IP-54 degree of ingress protection, fabricated from 3.15 mm thick CRCA sheet with front and rear opening including bus bar chamber, continuous GI strip earth bus bar 4 strips of Copper bus bar minimum 160 Amps capacity having suitable size cross sectional area, insulated color sleeves, procelain/epoxy insulators, rail channels cable alloy, danger notice board including provision of angle iron frame of size 40 x 40 x 6mm, 30 cm grouted in ground floor and 30 cm above GL duly painted including necessary excavation, foundation, PCC etc complete with locking arrangement duly powder coated of approved color connecting incoming & outgoing cable connection with suitable lugs, nuts, bolts, washers and cable joints, prewired complete with PVC insulated fire retardant copper conductor cable complete The panel shall be comprising of the following:-
Supply, fabricate, test and commissioning of of LT electrical out door distribution panel board(CPRI Approved) floor mounted cubical type dust proof, weather proof, vermin proof, astehically designed, having at least IP-54 degree of ingress protection, fabricated from 3.15 mm thick CRCA sheet with front and rear opening including bus bar chamber, continuous GI strip earth bus bar 4 strips of Copper bus bar minimum 500 Amps capacity having suitable size cross sectional area, insulated color sleeves, procelain/epoxy insulators, rail channels cable alloy, danger notice board including provision of angle iron frame of size 40 x 40 x 6mm, 30 cm grouted in ground floor and 30 cm above GL duly painted including necessary excavation, foundation, PCC etc complete with locking arrangement duly powder coated of approved color connecting incoming & outgoing cable connection with suitable lugs, nuts, bolts, washers and cable joints, prewired complete with PVC insulated fire retardant copper conductor cable complete The panel shall be comprising of the following:-
Supply, fabricate, test and commissioning of LT electrical out door distribution panel board(CPRI Approved) floor mounted cubical type dust proof, weather proof, vermin proof, astehically designed, having at least IP-54 degree of ingress protection, fabricated from 3.15 mm thick CRCA sheet with front and rear opening including bus bar chamber, continuous GI strip earth bus bar 4 strips of Copper bus bar minimum 100 Amps capacity having suitable size cross sectional area, insulated color sleeves, procelain/epoxy insulators, rail channels cable alloy, danger notice board including provision of angle iron frame of size 40 x 40 x 6mm, 30 cm grouted in ground floor and 30 cm above GL duly painted including necessary excavation, foundation, PCC etc complete with locking arrangement duly powder coated of approved color connecting incoming & outgoing cable connection with suitable lugs, nuts, bolts, washers and cable joints, prewired complete with PVC insulated fire retardant copper conductor cable complete The panel shall be comprising of the following:-
Supply, fabricate, test and commissioning of electrical out door distribution panel board(CPRI Approved) floor mounted cubical type dust proof, weather proof, vermin proof, astehically designed, having at least IP-54 degree of ingress protection, fabricated from 3.15 mm thick CRCA sheet with front and rear opening including bus bar chamber, continuous GI strip earth bus bar 4 strips of Copper bus bar minimum 200 Amps capacity having suitable size cross sectional area, insulated color sleeves, procelain/epoxy insulators, rail channels cable alloy, danger notice board including provision of angle iron frame of size 40 x 40 x 6mm, 30 cm grouted in ground floor and 30 cm above GL duly painted including necessary excavation, foundation, PCC etc complete with locking arrangement duly powder coated of approved color connecting incoming & outgoing cable connection with suitable lugs, nuts, bolts, washers and cable joints, prewired complete with PVC insulated fire retardant copper conductor cable complete The panel shall be comprising of the following:-
Supply, fabricate, test and commissioning of LT electrical out door distribution panel board(CPRI Approved) floor mounted cubical type dust proof, weather proof, vermin proof, astehically designed, having at least IP-54 degree of ingress protection, fabricated from 3.15 mm thick CRCA sheet with front and rear opening including bus bar chamber, continuous GI strip earth bus bar 4 strips of Copper bus bar minimum 100 Amps capacity having suitable size cross sectional area, insulated color sleeves, procelain/epoxy insulators, rail channels cable alloy, danger notice board including provision of angle iron frame of size 40 x 40 x 6mm, 30 cm grouted in ground floor and 30 cm above GL duly painted including necessary excavation, foundation, PCC etc complete with locking arrangement duly powder coated of approved color connecting incoming & outgoing cable connection with suitable lugs, nuts, bolts, washers and cable joints, prewired complete with PVC insulated fire retardant copper conductor cable complete The panel shall be comprising of the following:-
M&L for straight through joint (epoxy) for LT 1100 Volts grade, aluminum conductor including jointing kits, aluminium ferrules and labour complete for making joints and testing complete all as specified and directed.
Cable size 70 to 120 Sqmm, 3.5 core
Cable size 150 to 185 Sqmm, 3.5 core
M & L for road marking with hot applied thermoplastic compound with reflectorising glass beads using mechanical plant on bituminuos surface providing and laying of hot applied thermoplastic compound 1.5mm thick including reflectorising glass beads @ 250grams/sqm area. thickness of 1.5mm of thermoplastic compound is exclusive of surface applied glass beads as per IRC : 35 the finishined surface to level uniform and free from streaks and holes complete all as specified and directed.
M & L for providing and fixing of Cats eye (glow studs) heavy duty integral stem, reflective, PVC with elegant finish of size 100mmX100mm and 20mm high fixed by adhesive to the road surface. The road studs should have reflectors filled on two side of the studs complete all as specified and as directed. make- Protek model no-108RPM or equivalent make & model as approved by the GE.
Supply and fixing illuminating rod made out of 50mm bore MS pipe wall thickness 1.6mm, 850mm long, top 600mm length of pipe dellineated to have retro reflective tape of 100mm wide bands alternate in red and white shade. The bottom 250mm long pipe shall be embedded in and including provision of foundation of size 300mmX300mmX300mm with cement concrete (1:4:8) type D-2 (using 40mm graded aggregate ),MS plate 5mm thick , 60mm dia shall be welded to pipe at top and MS plate 5mm thick 100mm diashall be welded to pipe at bottom, including tarring of embedded MS items and remaining provided with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M & L for providing polythene film 400 micron as per IS 2508 of approved colour and quality laid over fine sand with side and end laps of 15 cms complete all as specified and directed.
M&L for 150 mm thickness (compacted thickness) of WMM (Wet Mix Macadam) in two layers of 75mm thick each layer, as per table 400-12 & 400-13 of MORTH, IRC specification with crushed stone aggregate, of specified gradiant spreading using sensor paver including side form work rolled and consolidated to required gradiant and camber complete all as specified.
M & L for Dry lean Cement Concrete (DLC) of average thickness 150mm with 7 days compressive strength of 10N/mm2 with min cement of 180 to 200 Kg/Cum using grading as per MORTH specification and as per design Mix, spread, rolled and consolidated to required camber and gradient using necessary mechanical sensor paver and tandem vibratory roller of capacity exceeding 8 tonne and not exceeding 12 tonne capacity complete all as specified and as directed.
M & L for 150mm thick pavement quality concrete (PQC) of flexural strength not less than 45 Kg/Sqcm in field using graded aggregate, minimum cement content 400 Kg/cum mixed with non circular synthetic fibre @ 0.25% by weight of cement as directed including formwork for laying in bays complete all as specified.
M&L for forming contraction(dummy) joints upto 40 mm deep x 8 mm wide (cutting by using diamond cutter) and filled with exapended polyureathane foam (armoured board) applying bond breaker tape on top of armour board for complete width of joint including provision of closed cell polyurethene back up rod 10mm dia and sealed with 10mm (minimum depth of sealent above back up rod shall be 10mm) polyurethene/polysulphide sealent conplying with IRC-57 -2006,(10 Years warranty ) primer the site masking tape on edges of joint to prevent spillage of sealent on top surface and to give a neat finish to the sealent and removing the masking tape after sealennt applied complete all as specified.
M & L for providing 400 micron thick HDPE sheet (Virgin quality) of weight 390gm/sqm over tack coat as per specification with specified overlap between adjacnt strip and transverse joint etc including a tack coat of VG-10 at the rate 3.5 kg per 10sqm complete all as specified and as directed.
M & L for forming construction joints 25mm deep x 10 mm wide (cutting by using diamond cutter) and filled with exapended polyureathane foam (armoured board) applying bond breaker tape on top of armour board for complete width of joint including provision of closed cell polyurethene back up rod 10mm dia and sealed with 10mm (minimum depth of sealent above back up rod shall be 10mm) polyurethene/polysulphide sealent conplying with IRC - 57 - 2006,(10 Yrs warranty ) primer the site masking tape on edges of joint to prevent spillage of sealent on top surface and to give a neat finish to the sealent and removing the masking tape after sealennt applied complete all as specified.
M & L for forming expansion joints 25mm wide (cutting by using diamond cutter to full depth of slab) and filled with exapended polyureathane foam (armoured board) applying bond breaker tape on top of armour board for complete width of joint including provision of closed cell polyurethene back up rod 10mm dia and sealed with 10mm (minimum depth of sealent above back up rod shall be 10mm) polyurethene/polysulphide sealent conplying with IRC - 57 - 2006,(10 Yrs warranty ) primer the site masking tape on edges of joint to prevent spillage of sealent on top surface and to give a neat finish to the sealent and removing the masking tape after sealennt applied complete all as specified.
M&L preparing new concrete surface and applying two coats of water base paint in camouflage pattern over a coat of primer
Supply, install, testing and commissioning of Diesel engine driven generating set minimum 62.5 KVA, 3 phase 4 wire, 415 volts,1500 RPM, 50 Hz power supply with power factor 0.8 coupled directly to alternator mounted on a common base plate complete with integral acoustic enclosure having silent features such as modular bolted construction with fabrication on imported CNC torret punch machines, nine tank treatment process with pure polyster based powder coating to ensure long life in all weather conditions and for out door application/ installation, integrated design thereby facilitating /easy handling installation & shifting of the equipment at site. The design of integral acoustic enclosure should be any type approved by national Physical laboratory as per Central Pollution Control Board (CPCB-II) latest norms/regulation with fuel tank, battery and standard accessories and PCC foundation for (acoustic enclosure also 30 CM above ground level) as recommended by manufacturer, vibration pad, sand cushioning around PCC foundation, tools and spares, as provided by manufacturer all as specified and as directed with the following specifications.
(A) ENGINE - 3 cylinders, inline, 4 stroke cycle, Water cooled Natural aspirated, developing 80 BHP (minimum), compression ratiom 1500, governor G2, maximumallowable back pressure 4.5kPa at 1500 RPM under NTP conditions of BS:5514., charging alternator voltage 12V, current 35 Amps, starter motor rated violtage 12v, with battery 12V DC, 88AH, fuel system HSD, fuel tank capacity 150 Liter, oil cooler water cooled radiator capacity 20 Liter water pump type centrigal type gear driven The engine shall be provided with electrical starting arrangement & shall give the electrical output 62.5 KVA at 0.8 power factor, 415Volts at the alternator terminal
(B) ALTERNATOR : single bearing alternator suitable for continuous operation generating minimum 62.5KVA at 1500 RPM, 415Volts , 0.8 power factor (lag) suitable for 50 Hz, 3 phase, 4 wire system, confirming to BS 5000/ IS 4722. The alternator is brushless type, screen protected , revolving field, self excited, self regulated through an AVR. The alternator has the following features:a) ± 1.0% voltage regulation (max.) in static conditions(b) IP: 23 protection with insulation class H (c) Permissible overload of 10% for one hour in 12 hours of operation.
Controller provide configurable time delay of 0-300 sec to start after remote start signal and time delay of 0-600 secs prior to shutdown after stop signal. Engine Protective Functions includes- Configurable alarm outputEmergency stop: Annunciated whenever an emergency stop signal is received by the control(a).Low Lube oil pressure warning and shutdown(b)High engine water temperature warning/ shutdown(c) Low coolant temp warning (d) Sensor failure indication(e)Low and high battery voltage warning (f) Weak battery warning (g) Fail to start shut down(h) Cranking lockout: Control will not allow the starter to engage or to crank the running engine (j) Cyclic cranking : Configurable for the number of starting cycle (1 to 7) and duration of crank and rest periods. (k) Alternator Protective functions includes(l) High and Low AC voltage shut down(m) Under and over frequency shutdown / warning(n) Loss of sensing voltage input shut down Fuel tank: Sub Base Fuel tank of 14 SWG MS sheet of adequate capacity to operate 8 hrs on 100% load .(B) Base Rail: Base Rail with integral fuel tank is provided.Batteries: For electrical control circuit 2 no., 12 Volts batteries for electrical starting of DG set
AMF PANEL OUTDOOR TYPE :- Suitable for minimum 62.5 KVA DG Set factory made out of CRCA Steel 3mm thick Sheet floor mounted type and front operated type, totally enclosed dust, damp and vermin proof, all doors and joints will be suitable gasketed to form dust and vermin proof. The panel shall be powder coated with minimum thickness 50 microns, after elaborate pre-treatment to form a long lasting characteristic. The control panel shall be complete in all respect with fuses, wiring and labels etc, the following shall be incorporated in the AMF Panel :- (a) HRC Fuse with fuse base,Din type 200A-06 Nos (b) MCB,C-Curve,10 KA,DP 20A-01 No (c) MCB,C-Curve,10 KA,SP 6A-2 Nos (d) MCB,C-Curve,10 KA,SP 4A- 12 Nos (e) Current transfrmer,CL-1,5 VA,150 /5A-04 Nos (f) Four pole Contactor, 240 V AC,2 NO +2 NC,430 A, AC3-02 Nos for (DG Set & Commercial) (g) Indicating Lights R ,Y,LED type,240V AC -04 Nos (h) Indicating Lights B,LED type,240V AC -02 Nos (j) Illu Push Button with elements ,LED type -NO/NC-01 No. (k) Mushroom head push button,Press to lock,Turn to release-01 No (l) KW/PF/KWH meter 96 x 96 sqmm ,3 Phase Digital type 415 V AC-01 No.
(m) DC Ammeter 96 x 96 Sqmm,Digital type 0-20 A -01 No. (n) 24 V, 10 A DC Automatic Battery Charger with inbuilt trickle/boost facality-01 No (o) 4 Point Alarm Annuciator with inbuilt Hooter,Test,Accept & Reset Push button. (p) Solid state single element earth fault relay with 2 c/o contact, CTR-400/5A ,Aux supply 230V AC - 1 No. (q) AMF Controller,24 V DC - 01 No. (r) Aux relay,Coil voltage,24V DC,4C/O,14 PIN-24V DC-06 Nos (s) Thermal O/L Relay,with inbuilt SPP Feature.
Design,supply, installation, testing and commissioning indoor type, heavy duty, electrically operated Flame Proof ,Double box girder over head traveling Crane (EOT) designed & manufactured in accordance to IS-3177 of 1999 & IS-807 of 2006 and with flame proof components conforming to IS-2148, class-II capable to handle 10 (ten) ton load (SWL)with centre to centre clear span 8.5 metres; Bay length 178 mtr (+10m approx) ; longitudinal travel limited to 1.5 metre away from the wall on both sides; suitable for operation on 415 volts 3 phase 4 wire AC supply system; with necessary steel supporting structure with clear hook height 4.0 metres from FFL; including all electrical components, control , Cables Safety Control etc, floor operated with moveable pendant control to be operated by means of push buttons from floor level independantly of crab position with protective panel including down shop lead (DSL) trailing cable for CT motion and DSL of fastoon type FRLSH cable for LT motion complete all as specified including painting with fire resistant paint all as per manufacturer's specification all as per standard norms for the technical parameters and including supply and fixing of 50 mm square bar rail.
Design,supply, installation, testing and commissioning indoor type, heavy duty, electrically operated Flame Proof ,Double box girder over head traveling Crane (EOT) designed & manufactured in accordance to IS-3177 of 1999 & IS-807 of 2006 and with flame proof components conforming to IS-2148, class-II capable to handle 10 (ten) ton load (SWL)with centre to centre clear span 9 metres; Bay length 36 mtr ; longitudinal travel limited to 1.5 metre away from the wall on both sides; suitable for operation on 415 volts 3 phase 4 wire AC supply system; with necessary steel supporting structure with clear hook height 4.0 metres from FFL; including all electrical components, control , Cables Safety Control etc, floor operated with moveable pendant control to be operated by means of push buttons from floor level independantly of crab position with protective panel including down shop lead (DSL) trailing cable for CT motion and DSL of fastoon type FRLSH cable for LT motion complete all as specified including painting with fire resistant paint all as per manufacturer's specification all as per standard norms for the technical parameters and including supply and fixing of 50 mm square bar rail.
Design,supply, installation, testing and commissioning indoor type, heavy duty, electrically operated Flame Proof ,Double box girder over head traveling Crane (EOT) designed & manufactured in accordance to IS-3177 of 1999 & IS-807 of 2006 and with flame proof components conforming to IS-2148, class-II capable to handle 10 (ten) ton load (SWL)with centre to centre clear span 9 metres; Bay length 9 mtr ; longitudinal travel limited to 1.5 metre away from the wall on both sides; suitable for operation on 415 volts 3 phase 4 wire AC supply system; with necessary steel supporting structure with clear hook height 4.5 metres from FFL; including all electrical components, control , Cables Safety Control etc, floor operated with moveable pendant control to be operated by means of push buttons from floor level independantly of crab position with protective panel including down shop lead (DSL) trailing cable for CT motion and DSL of fastoon type FRLSH cable for LT motion complete all as specified including painting with ire resistant paint all as per manufacturer's specification all as per standard norms for the technical parameters and including supply and fixing of 50 mm square bar rail.
Supply and fix punched type concertrina coil 1050mm dia betweem two layers of fencing etc complete all as specified and directed. Note: Concertina coil shall be stretched to a maximum of 8 meter length
Supply and install flame proof control panel in cast aluminium alloy LM6 construction with suitable terminals & cable entries, light grey epoxy powder coated, SS hardware Certified by CMRS, Dhanbad for Group. IIA & IIB as per IS/IEC-60079 consisting of (i) SPN 4Way DB with MCB SPN 6-32A - 1No in each DB (ii) MCB SP 5-32A - 2Nos in each DB
Supply and install flame proof control panel in cast aluminium alloy LM6 construction with suitable terminals & cable entries, light grey epoxy powder coated, SS hardware Certified by CMRS, Dhanbad for Group. IIA & IIB as per IS/IEC-60079 consisting of (i) SPN 4Way DB with MCB TPN 32A - 1No in each DB
Supply and install flame proof control panel in cast aluminium alloy LM6 construction with suitable terminals & cable entries, light grey epoxy powder coated, SS hardware Certified by CMRS, Dhanbad for Group. IIA & IIB as per IS/IEC-60079 consisting of (i) TPN 4Way DB with MCB TPN 32A - 1No in each DB (ii) MCB SP 5-32A - 9Nos in each DB
Supply and install flame proof control panel in cast aluminium alloy LM6 construction with suitable terminals & cable entries, light grey epoxy powder coated, SS hardware Certified by CMRS, Dhanbad for Group. IIA & IIB as per IS/IEC-60079 consisting of (i) TPN 4Way DB with MCB TPN 63A - 1No in each DB (ii) MCB TPN 32A - 2Nos in each DB (iii) MCB SP 5-32A - 4Nos in each DB
Supply and install flame proof control panel in cast aluminium alloy LM6 construction with suitable terminals & cable entries, light grey epoxy powder coated, SS hardware Certified by CMRS, Dhanbad for Group. IIA & IIB as per IS/IEC-60079 consisting of (i) TPN 4Way DB with MCB TPN 32A - 2Nos in each DB (ii) MCB SP 6-32A - 4Nos in each DB
Supply and fixing LED light fitting 2x20 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size in flexible steel conduit with flame proof cable glands complete all as specified and directed.
Supply & fix of Flame proof LED light-High Lumen output fitting of 120 Watt with exclusive innovative designed, long life versatile pressure die cast aluminium IP65 flood light luminaire with high power LED as light source complete all as specified and directed.
Supply and fix Exhaust fan 250 mm (10") sweep AC, 240 volts, louvers, plastic body, fixed as per manufacturer instruction, connecting with and including 1.5 Sqmm copper conductor, PVC insulated and PVC sheathed three core cable complete all as specified and directed.
S & F LED batten single tube 1x 20 W (4 feet long) 230V, 6000K Rated CCTenergy efficient with atomic ballast bipin holders starter blocks , diffusers etc complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S & F LED tube of 1X8/10 W (2 feet) 230V,6000k, Taskline AL slim LED batten excellent energy saving and maintenance -free operationHousing made up of extruded aluminium and extruded PC diffuser complete with all accessories and complete all as specified and directed.
S&F LED Building Security light luminaire led 15 W 5700K with aesthetically designed sheet aluminium housing and UV stabilised acrylic cover complete with lamp and internal connection including bracket made of 40 mm dia GI ppe light grade fixed with MS Clamp of suitable size grouted on wall with suitable nos of screws complete all as specified and directed.
M&L for MCB Single pole & neutral 230 volt C curve 10 KA, 6-32 Amps capacity complete all as specified and directed complete all as specified and directed.
M&L for MCB single pole,5 to 30 Amp 240 volt C curve 10 KA complete all as specified and directed.
Tacon Infrastructure Pvt. Ltd.
Parth Infrastructure Pvt. Ltd.
DHARIWAL TRADERS PRIVATE LIMITED
RAGHUSONS INFRA ENGINEERING PVT. LTD
Agarwal Jagdish Construction Company Private Limited
Hariom Projects Pvt Ltd
SOOD ASSOCIATES PVT LTD
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid