Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.1 LAccepted-Finance | ₹31.1 L | L1 | Accepted-Finance Selected |
| 2 | L2₹37.9 LAccepted-Finance | ₹37.9 L | L2 | Accepted-Finance Selected |
| 3 | L3₹56.3 LAccepted-Finance | ₹56.3 L | L3 | Accepted-Finance Selected |
| 4 | L4₹57.4 LAccepted-Finance GROUND FLOOR G 1154 A MANSAROVAR PARK SHAHDARA DELHI 110032 | SHAHDARA | DELHI | 110032 | ₹57.4 L | L4 | Accepted-Finance Selected |
Tender Value
₹58.0 L
EMD Value
₹1.2 L
Closing Date
4 Feb 2026, 12:00 pmClosed
Executive Engineer (E)
O/o EE(E) PWD EMD M-351, R.No.185, Old Sectt Delhi
(Sh- Renovation / Rewiring of Qtr No. 47/11, 17/5, 33/22, D-2/3, 33/4, 33/6, 33/19 and upgradation of kitchen and toilet and other misc. works).
2026_PWD_285781_1
111/2025-26/EMD M-351/EE(E)
Open Tender
Miscellaneous Services
120 days
Rajpur Road
Please refer Tender documents.
10 documents required · 10 mandatory
₹0
₹1.2 L
4 Feb 2026
28 Jan 2026
4 Feb 2026
28 Jan 2026
4 Feb 2026
28 Jan 2026
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc as required.
Group B
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
Group B
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
Group B
Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
2 X 16 sq. mm + 1 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 1.5 sq. mm
3 x 4 sq. mm
3 x 6 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
15/16 amp switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
Bell push
25 A modular SPMCB
6 pin 25 A modular type socket
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.
1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
4 Module (125mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
12 Module (200mmX150mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
1 or 2 Module
3 Module
4 Module
6 Module
8 Module
12 Module
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing Ding dong bell suitable for single phase, 230 volts, complete as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way, Double door
12 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way (4 + 24), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
40 Amp Double pole
63 Amp Double pole
63 A Triple pole and neutral
Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS: 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI ≥80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast/ Extruded aluminium Body including trim
Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS: 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI ≥80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast/ Extruded aluminium Body including trim with Aluminium Reflector
Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS: 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI ≥80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness ≥ 1.20 mm)
Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66, IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supplying & Laying following size XLPE insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade in existing DWC/GI/pipe/on surface or loose for connection and testing etc as reqd.
3 x 10 sq.mm
4 X 16 sq.mm
Supply, Installation, Testing and Commissioning of BEE rated, ceiling fan with squirrel cage induction Motor, class of insulation: B, 3 nos. metal( Aliminium alloy blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body, Power Factor not less than 0.9 , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit of suitable wattage for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as reqd.
1200mm, BEE 3 star rating, service value ≥5.0 to < 5.5 CM/Min/Watt, air delivery 210 CM/Min ( Minimum)
Supplying, Installation, Testing and Commissioning of 200 mm sweep fresh air fan working on 230 +/- 10 V single phase 50 Hz Frequency complete with shutter in existing hole of suitable size making good the same i/c connections, interconnections etc. complete as reqd.
Supplying, Installation, Testing and Commissioning of 300 mm Sweep 900 RPM Heavy Duty ISI Marked Exhaust fan with louvers & shutters in the existing opening, including making good the same, connection, testing, commissioning etc. as reqd.
Supply, Installation, Testing & Commissioning of Battery operated (to power minimum 8Year) RF based ultra low powered wireless water level data top transmitter (minimum 15dBm power) operating in frequency band 865~868mHZ, confirming to EN 300 220 and ingress protection IP68, with scale and corrossion free capcitance based level sensor to measure water level percentage from 0% to 100% (± 5% with 1% resolution for tanks upto 10mtr depth with auto calibration sensor. It should also calculate trend & rate of rise/ fall of water level and transmit the data alongwith water level data. It will have input for detection of conductivity based flow in pipeline and on/off status of motorized valve and send the data wirelessly. It should have a technique to avoid collision of RF signal and minimise corruption of data. It should have CRC check in transmitted data to detect error in block of data. (Underground sump)
Supply, Installation, Testing & Commissioning of Battery operated (to power minimum 8Year) RF based ultra low powered wireless water level data sump transmitter (minimum 15dBm power) operating in frequency band 865~868mHZ, confirming to EN 300 220 and ingress protection IP68, with scale and corrossion free capcitance based level sensor to measure water level percentage from 0% to 100% (± 5% with 1% resolution for tanks upto 10mtr depth with auto calibration sensor. It should also calculate trend & rate of rise/ fall of water level and transmit the data alongwith water level data. It will have input for detection of conductivity based flow in pipeline and on/off status of motorized valve and send the data wirelessly. It should have a technique to avoid collision of RF signal and minimise corruption of data. It should have CRC check in transmitted data to detect error in block of data.(overhead tank)
Supply, Installation, Testing & Commissioning of 230Vac/ 5V DC operated RF signal booster operating in Frequency band 865~868mHZ confirming to EN.300.220 to relay/ transmit the RF signal received from multiple transmitters to further distance with LED based instant indicator. It should have a technique to avoid collision of RF signal and minimise corruption of data. A mechanism should be there to avoid circular transmission of data between repeaters. LED based visual indication should be there to indicate signal strength of received wireless data. It should have RF receiving sensitivity of minimum -125dBm and transmission power of minimum 15dBm. It should be configurable to filter out RF signal of particular transmitters to reduce the transmission signals in Air. It should have shock proof ABS body with IP65 rating and must have suitable mounting arrangements on wall or stand.
Supply, Installation, Testing & Commissioning of 12V DC operated wireless RTU to receive data wirelessly from remote sensor data tansmitters/ RF boosters and push the data to BMS/ controller unit through UART and to the server through 4G/ 5G GSM network. This device will be equipped IOT sim of cellular network service providers. It should have LCD/ OLED screen to display various parameters and status of network/ connectivity. The enclosure should be IP65 rating with suitable mounting arrangements. It should be equipped with wifi module to connect with server through available wifi network. Various settings should be configurable through common web browser using wifi feature.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Finishing with Deluxe Multi surface paint system for interiors / exteriors as per manufacturers specifications : a) Painting Steel work with Deluxe Multi Surface Paint to give an even shade of approved brand and manufacture .
S.I.T.C of 20W LED bulkhead fitting made out of CRCA sheet duly power coated/Cast Aluminium body, confirming to IP66, suitable for operation on 240 V, 50 Hz AC Supply having power factor ≥ 0.90, complete i/c making connection, testing and commissioning etc complete as reqd. (Note:- Contractor shall submit 5 Years gurantee certificate of respective manufacturer along with the fitting).
Supplying, Installation, testing and commissioning of 8-11 Watt LED Mini Bollard fitting made out of CRCA sheet, duly powder coated /Aluminium body, confirming to IP - 65, suitable for operation on 150 V to 270 V,(5500 to 6500K), 50 Hz AC Supply, having power factor ≥ 0.90, CRI > 80, Luminaries efficacy ≥ 70 lumen/watt , Driver efficiency > 85%, L-70 Life 50,000 burning hours. i/c CC foundation of suitable size with foundation bolt complete as required. (Note:- Contractor shall submit 5 Years gurantee certificate of respective manufacturer along with the fitting).
Supply, installation, testing and commissioning of following watt LED Decorative post top fitting with aluminium die cast housing, Polycarbonate / Pamma prismatic clear/frosted diffuser with operating range of 100-270V, PF> 0.95, luminious efficiency > 100 lumens/watt, CCT 3000k-6500k (CCT shall be decided by Engineer-in-charge), IP 65 with 4KV surge protection i/c connections & interconnections etc as required.
SITC of Fancy wall bracket fitting with retrofit LED bulb 7-9 watt complete with all accessories i/c LED bulb etc. directly on wall i/c connections with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and earthing etc as required. (Note:- Contractor shall submit 5 Years gurantee certificate of respective manufacturer along with the fitting). (Sample Appoved by Engineer-in-charge before installation at site).
Supplying, Installation, Testing & Commissioning of minimum 3 watt, IP 65 LED Step / foot light having colour temperature 3000K- 6500K etc complete as required. (CCT shall be decided by Engineer-in-Charge).
Supplying, Installation, Testing & Commissioning of 3 to 7 watt ,IP 65 LED out door 2 way wall light having colour temperature 3000K - 6500K etc complete as required (CCT shall be decided by Engineer-in-Charge)
Supplying, Installation, Testing & Commissioning of SMC pole Box of size 250mm x 200mm x 105mm with hinged cover on surface/ recess/pole complete with aluminium connector strip - 2 Nos, MS Clamp - 2 Nos., 6-32amp. C series SPMCB- 1 No., having IP: 66 protection connection etc. as reqd.
Supplying, installation, testing & commissioning of following capacity water storage vertical /horizontal type geyser working on 230 +/- 10 V single phase 50 Hz Frequency, tank with altra thick super cold rolled steel plates, puff insolation, rated pressure: 8 bar, Temperature range 75 degree C, heating indicator, temperature setting: manual, power consumption: min 2 kw i/c Thermostate, Thermal cut off, mltifactional sefety valve complete with necessary accessories and 25 amp plug top etc, as reqd.
6 ltrs. Rating Minimum 4 star
25 ltrs. Rating Minimum 4 star
SITC of Auto Clean Chimney Curved Glass electrical chimney with decorative frame of steel body structure having width of 600 mm,air suction capacity minimum 1200 cubic Meter/hr, having auto clean , touch sensor, metal blower, metal housing, oil collector, heat auto cleaner, touch panel, curved glass etc i/c providing & fixing 6 inch alu. pipe ( 3 mtr ) , 6 inch cowels & clamp etc as reqd.
SITC Water Pressure Booster Pump 0.5 HP/0.37 kW, 220V AC, 50 Hz, Pipe size: 25X25 mm, Maximum Flow Rate: 2910 Liters Per Hour, Maximum Lifting Height: 22 Metres
S/I/T/C of Surface mounted LED strip (flexible) , 2835 SMD package with a thermal tape with high thermal conductivity, system power: 15 W/metre, luminous flux 1200lm, colour temperature of 4000K, CRI>80, Anodized aluminium extrusion, Opal diffuser, 12V DC, constant voltage driving circuit, electronic control gear. IP20 L-1000m etc. complete as reqd.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.43 MB
111RajpurRoadMiscEIWorkVrsQtrs.pdf
Tender Documents • 2.42 MB
BOQ_378224.xls
BOQ • 0.50 MB
Download all tender documents and submit your bid