Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹15,000
Closing Date
11 Aug 2021, 11:00 amClosed
Manager SRC-Com
Hindustan Shipyard Limited Gandhigram SR Complex Visakhapatnam 530 005
Cleaning, Chipping and Painting of 18Nos Tanks on MV Swaraj Dweep
2021_HSL_86884_1
20/21997/052/2021-22
Open Tender
Miscellaneous Services
Service
21 days
HSL Visakhapatnam
Please refer Tender documents.
8 documents required · 8 mandatory
₹590
Yes
HSL
₹15,000
Yes
26 Aug 2021
2 Aug 2021
11 Aug 2021
2 Aug 2021
11 Aug 2021
2 Aug 2021
Amount
Cleaning, Chipping and Painting of 18Nos of Tanks: The firm is to execute the complete below mentioned SoW as per conditions mentioned in Annexure-A and finally Satisfactoy Operational trials to be shown to SS, Class & HSL.
THE FOLLOWING TANKS TO BE CLEANED FREE OF SLUDGE AND MUD FOR INSPECTION AND IF THERE CHIPPING / PRIMERING & PAINTING, SAME TO BE ATTENDED. ALSO ASSUME ABOUT 5.0 TONS MUD / SLUDGE / CHIPPED RUST TO BE REMOVED FROM THE FOLLOWING TANKS ALTOGETHER TO BE PRESENTED FOR INSPECTION & THEIR RECOMMENDATIONS IF ANY TO BE ATTENDED.
NO-21 ( P ) FW TANK--- (CAP. - 340 CUB M) TEST AND EXAMINATION: a) MUD & RUST REMOVAL : 0.1 MT b) MECHANICAL CHIPPING: 5 % OF THE INTERNALS SURFACE AREA c) PRIMER AREA ( 2 COATS ): 10 % OF THE INTERNALS SURFACE AREA d) FINISH COAT: 100 % OF THE INTERNALS SURFACE AREA
NO-21 ( S ) FW TANK--- (CAP. - 441 CUB M)---TEST & EXAMINATION: a) MUD & RUST REMOVAL : 0.1 MT b) MECHANICAL CHIPPING: 5 % OF THE INTERNALS SURFACE AREA c) PRIMER AREA ( 2 COATS ): 10 % OF THE INTERNALS SURFACE AREA d) FINISH COAT: 100 % OF THE INTERNALS SURFACE AREA
NO-40 ( C ) FW TANK--- (CAP. - 201 CUB M)-TEST: a) MUD & RUST REMOVAL : 0.5 MT b) MECHANICAL CHIPPING: 5 % OF THE INTERNALS SURFACE AREA c) PRIMER AREA ( 2 COATS ): 10 % OF THE INTERNALS SURFACE AREA d) FINISH COAT: 100 % OF THE INTERNALS SURFACE AREA.
TANKS OTHER THAN CSH FOR INSPECTION & REPAIRS : THE FOLLOWING TANKS TO BE CLEANED FREE OF SLUDGE AND MUD FOR SURVEYORS INSPECTION.CHIPPING / PRIMERING & PAINTING, SAME TO BE ATTENDED. ALSO ASSUME 10 TONS MUD / SLUDGE/ CHIPPED RUST TO BE REMOVED FROM THE FOLLOWING TANKS ALTOGETHER .
NO:1 ( C ) WB DB TANK (CAP. - 262 CUB M) : a) MUD & RUST REMOVAL : 1.0 MT b) MECHANICAL CHIPPING: 30% OF THE INTERNALS SURFACE AREA c) PRIMER AREA ( 2 COATS ): 40% OF THE INTERNALS SURFACE AREA d) FINISH COAT: 100 % OF THE INTERNALS SURFACE AREA .
NO-2 ( P ) WB DB TANK (CAP. - 124 CUB M) : a) MUD & RUST REMOVAL : 0.5 MT b) MECHANICAL CHIPPING: 30% OF THE INTERNALS SURFACE AREA c) PRIMER AREA ( 2 COATS ): 40% OF THE INTERNALS SURFACE AREA, d) FINISH COAT: 100 % OF THE INTERNALS SURFACE AREA .
NO-2 ( P ) WB DB TANK (CAP. - 119 CUB M) : a) MUD & RUST REMOVAL : 0.5 MT b) MECHANICAL CHIPPING: 30% OF THE INTERNALS SURFACE AREA c) PRIMER AREA ( 2 COATS ): 40% OF THE INTERNALS SURFACE AREA d) FINISH COAT: 100 % OF THE INTERNALS SURFACE AREA .
NO-3(P) WB DB TANK (CAP. - 180 CUB M) : a) MUD & RUST REMOVAL : 0.5 MT b) MECHANICAL CHIPPING: 30% OF THE INTERNALS SURFACE AREA c) PRIMER AREA ( 2 COATS ): 40% OF THE INTERNALS SURFACE AREA d) FINISH COAT: 100 % OF THE INTERNALS SURFACE AREA .
NO-3(S) WB DB TANK (CAP. - 180 CUB M) : a) MUD & RUST REMOVAL : 0.5 MT, b) MECHANICAL CHIPPING: 30% OF THE INTERNALS SURFACE AREA. c) PRIMER AREA ( 2 COATS ): 40% OF THE INTERNALS SURFACE AREA, d) FINISH COAT: 100 % OF THE INTERNALS SURFACE AREA .
NO-4(P) WB DB TANK (CAP. - 160 CUB M) : a) MUD & RUST REMOVAL : 0.5 MT b) MECHANICAL CHIPPING: 30% OF THE INTERNALS SURFACE AREA. c) PRIMER AREA ( 2 COATS ): 40% OF THE INTERNALS SURFACE AREA, d) FINISH COAT: 100 % OF THE INTERNALS SURFACE AREA .
NO-4(S) WB DB TANK (CAP. - 160 CUB M) : a) MUD & RUST REMOVAL : 0.5 MT b) MECHANICAL CHIPPING: 30% OF THE INTERNALS SURFACE AREA c) PRIMER AREA ( 2 COATS ): 40% OF THE INTERNALS SURFACE AREA d) FINISH COAT: 100 % OF THE INTERNALS SURFACE AREA .
NO-5(P) WB DB TANK (CAP. - 65 CUB M) : a) MUD & RUST REMOVAL : 0.5 MT b) MECHANICAL CHIPPING: 30% OF THE INTERNALS SURFACE AREA c) PRIMER AREA ( 2 COATS ): 40% OF THE INTERNALS SURFACE AREA d) FINISH COAT: 100 % OF THE INTERNALS SURFACE AREA .
NO-5(S) WB DB TANK (CAP. - 65 CUB M) : a) MUD & RUST REMOVAL : 0.5 MT b) MECHANICAL CHIPPING: 30% OF THE INTERNALS SURFACE AREA c) PRIMER AREA ( 2 COATS ): 40% OF THE INTERNALS SURFACE AREA d) FINISH COAT: 100 % OF THE INTERNALS SURFACE AREA .
NO-6A(P) WB DB TANK (CAP. - 50 CUB M) : a) MUD & RUST REMOVAL : 0.3 MT b) MECHANICAL CHIPPING: 40% OF THE INTERNALS SURFACE AREA. c) PRIMER AREA ( 2 COATS ): 50% OF THE INTERNALS SURFACE AREA, d) FINISH COAT: 100 % OF THE INTERNALS SURFACE AREA .
NO-6A(S) WB DB TANK (CAP. - 66 CUB M) : a) MUD & RUST REMOVAL : 0.3 MT b) MECHANICAL CHIPPING: 40% OF THE INTERNALS SURFACE AREA c) PRIMER AREA ( 2 COATS ): 50% OF THE INTERNALS SURFACE AREA d) FINISH COAT: 100 % OF THE INTERNALS SURFACE AREA .
THE FOLLOWING FRESH WATER TANKS to be cleaned for inspection for INTERNAL STRUCTURE CORROSION AND PAINTING CONDITION. ASSUME 10 % AREA REQUIRE SPOT CHIPPIND, PRIMERING( 2 COATS ), AND PAINTING ( 2 COATS). PRIOR PAINTING TANKS TO BE HIGH PRESSURE WATER WASHED AND RINSED WITH FRESH WATER FINALLY. ( PAINTS - SHIP SUPPLY )
NO-22 ( P ) FW TANK--- (CAP. - 340 CUB M) : a) MUD & RUST REMOVAL : 0.1 MT b) MECHANICAL CHIPPING: 5% OF THE INTERNALS SURFACE AREA c) PRIMER AREA ( 2 COATS ): 10% OF THE INTERNALS SURFACE AREA d) FINISH COAT: 100 % OF THE INTERNALS SURFACE AREA .
NO-22 ( S ) FW TANK--- (CAP. - 340 CUB M) : a) MUD & RUST REMOVAL : 0.1 MT b) MECHANICAL CHIPPING: 5% OF THE INTERNALS SURFACE AREA c) PRIMER AREA ( 2 COATS ): 10% OF THE INTERNALS SURFACE AREA d) FINISH COAT: 100 % OF THE INTERNALS SURFACE AREA .
NO-41 ( P ) FW TANK--- (CAP. - 194 CUB M) : a) MUD & RUST REMOVAL : 0.1 MT b) MECHANICAL CHIPPING: 5% OF THE INTERNALS SURFACE AREA c) PRIMER AREA ( 2 COATS ): 10% OF THE INTERNALS SURFACE AREA d) FINISH COAT: 100 % OF THE INTERNALS SURFACE AREA .
NO-41 ( S ) FW TANK--- (CAP. - 173 CUB M) : a) MUD & RUST REMOVAL : 0.1 MT b) MECHANICAL CHIPPING: 5% OF THE INTERNALS SURFACE AREA c) PRIMER AREA ( 2 COATS ): 10% OF THE INTERNALS SURFACE AREA d) FINISH COAT: 100 % OF THE INTERNALS SURFACE AREA .
SRI VENKATA RAMANA SOCIETY
SYAMALA ENTERPRISES
USHODAYA ENTERPRISES
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .