3 TR Ductable AC units at E10B TE BSNL Kurnool
9186494
GEM/2026/B/7411832
Two Packet Bid
Supply of 3 TR Ductable Inverter type Aircooled split AC unit,Installation Testing and Commissionin
Andhra Pradesh; Ntr
Total value wise evaluation
BOQ
11 documents required · 11 mandatory
3 yrs
₹3 L
₹3 L
80%
ACCOUNTS OFFICER (CASH), ACCOUNTS OFFICER (CASH), O/o GMTD, BSNL, Kurnool, (Accounts Officer (cash))
₹18,789
20 Apr 2026
4 Apr 2026
20 Apr 2026
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | Supply of 3 TR Ductable Inverter type Aircooled split AC unit | Supply of 3 TR Ductable Inverter type Aircooled split AC unit with scroll or rotary compressor single circuit refrigerant type with Not less than 36000 BTU per hr having EER of Min 10 BTU per Watthour and Static pressure of min 45 Pascals with copper coils evaporator and condenser as per specification as required Note rate shall be quoted inclusive of GST | 6 | Nos | Cheriala Anjaneyulu 520004,O/o EE(E),BSNL Electrical Division,1 st Floor, Telephone Exchange Building Autonagar, Vijayawada- 520007 | 60 |
| 2 | Installation Testing and Commissioning of 3 TR Ductable type Air cooled split AC unit | Installation Testing & Commissioning ICT of 3 TR Ductable type Air cooled split AC unit as per specification including lifting and positioning of indoor and outdoor units Pre-testing vaccumisation pressure testing with nitrogen Supplying and charging of refrigerant gas Supplying and Laying of power supply cable on surface or recess from outdoor unit to the nearby existing Supply Terminal Box as required Rate shall be quoted inclusive of GST | 6 | Jobs | Cheriala Anjaneyulu 520004,O/o EE(E),BSNL Electrical Division,1 st Floor, Telephone Exchange Building Autonagar, Vijayawada- 520007 | 60 |
| 3 | Providing and laying of refrigerant pipes and other works | Providing and laying of refrigerant connection with copper tubes of suitable gauge and sizes as per manufacturer recommendation for both suction and liquid lines on existing tray/ wall / partition including Supplying and Fixing of all required accessories such as bends elbows couplings including brazing pressure testing Providing and fixing suitable clamps supports and insulating the refrigerant lines with insulation hoses or with nitrile rubber sleeve wrapped with Thermal tape etc including Interconnection cabling between Indoor to Outdoor units complete as required.Rate shall be quoted inclusive of GST | 110 | Mtrs | Cheriala Anjaneyulu 520004,O/o EE(E),BSNL Electrical Division,1 st Floor, Telephone Exchange Building Autonagar, Vijayawada- 520007 | 60 |
| 4 | Supplying and fixing of 25 mm dia of UPVC Pipe | Supplying and fixing of 25 mm dia of UPVC Pipe along with accessories on surface or recess including cutting the wall/partition and making good the same to drain condensate water etc complete as required Rate shall be quoted inclusive of GST | 100 | Mtrs | Cheriala Anjaneyulu 520004,O/o EE(E),BSNL Electrical Division,1 st Floor, Telephone Exchange Building Autonagar, Vijayawada- 520007 | 60 |
| 5 | providing and fixing of suspension round rods | providing and fixing of suitable size MS rods for suspending the indoor units with anchor bolts in ceiling i/c providing double nuts on each suspension rod and making good damages etc. complete as required Rate shall be quoted inclusive of GST | 24 | Nos | Cheriala Anjaneyulu 520004,O/o EE(E),BSNL Electrical Division,1 st Floor, Telephone Exchange Building Autonagar, Vijayawada- 520007 | 60 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_9186494.pdf
GEM_BID
boq_kurnool_3tr_ductable_ac_units_2026-04-02-16-14-54_2ad80e8ab0dee76de3d26a00e353b5b8.pdf
BOQ
boq_kurnool_3tr_ductable_ac_units_2026-04-02-16-14-54_4e0d5e7f07767d5b7a27950969a02d10.csv
BOQ
ATC3TR_53538482-fc1b-462c-befe1775128247761_sudhakarm@bsnl.co.in.pdf
OTHER
list-of-categories-where-trials-are-allowed_1712126171.pdf
OTHER
gtc.pdf
OTHER
ATC3TR_53538482-fc1b-462c-befe1775128247761_sudhakarm@bsnl.co.in.pdf
GEM_OTHER • 0.94 MB
list-of-categories-where-trials-are-allowed_1712126171.pdf
GEM_OTHER • 0.52 MB
gtc.pdf
GEM_OTHER • 0.71 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .