Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 LAccepted-AOC | L1 | Accepted-AOC Being Lowest Tenderer | |
| 2 | L2₹7.3 L+₹31,252.60 (4.49%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest Tenderer | |
| 3 | L3₹7.4 L+₹43,750 (6.28%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest Tenderer | |
| 4 | L4₹7.5 L+₹49,074 (7.04%)Rejected-Finance DOOR NO 4 202 MASJID STREET EPURUPALEM CHIRALA 533166 | CHIRALA | 533166 | L4 | Rejected-Finance Other than Lowest Tenderer | |
| 5 | L5₹7.6 L+₹58,808.20 (8.44%)Rejected-Finance | L5 | Rejected-Finance Other than Lowest Tenderer |
Tender Value
₹9.4 L
EMD Value
₹18,800
Closing Date
13 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) Suryalanka
AGE (I) SURYALANKA MILITARY ENGINEER SERVICES BAPATLA POST -522 102 SURYALANKA
AS PER BOQ AND TENDER DOCUMENT
2022_MES_563664_1
AGE(I)/SL/8494
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
AGE (I) Suryalanka
PLEASE REFER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
AGE (I) SURYALANKA
₹18,800
Yes
24 Dec 2022
17 Nov 2022
15 Dec 2022
17 Nov 2022
13 Dec 2022
30 Nov 2022
18 Nov 2022 - 24 Nov 2022
Amount
M&L for Dismantling concrete poles/ struts, street lights any size including removing of foundation and coping and removing from site for issue to schedule of credit complete all as specified and directed
M&L for dismantling of ACSR/AAC conductor of any size and type from pole complete all as specified and directed
M&L for dismantling of insulator any type and size type from pole complete all as specified and directed
M&L for dismantling of cross arm, channels etc by removing nuts and bolts any type and size complete all as specified and directed
M&L for Dismantling stay assembly set including foundation and making good complete all as specified and directed
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core 70 sqmm complete all as specified and directed
All as per Item No.6 above but cable of size 3.5 core 35 sqmm complete all as specified and directed
All as per Item No.6 above but cable of size 4 core 16 sqmm complete all as specified and directed
All as per Item No.6 above but cable of size 2 core 10 sqmm complete all as specified and directed
S&F in replacement of LT junction box outdoor, single door of size minimum 0.8 x 1 x 0.6 m (i.e 0.8 Mtr height, 1 Mtr width and 0.6 Mtr depth) or suitable higher size made out of CRCA Sheet of 3.15 mm thick with powder coated painting with four numbers of 100 Amps aluminium bars duly insulated on insulators / suitable size Bakelite sheet fixed including making necessary drilling on bus bars for fixing of out going cables upto 50 Sqmm XLPE - 05 Nos with minimum gap as per IE standards and one No MCCB of capacity 63 A, 4 Pole, 415 V 25 KA and suitable size of angle Iron 50 x 50 x 5 mm thick for stand complete ( free space between MCCB / busbar and other connection items should be provided,) including fixing arrangement by excavation, PCC etc for the height as directed danger notice sticker, cable glands, internal wiring with FRLS copper wires of suitable size complete all as specified and directed Note : (a). Contractor should submit the diagram of LT Jn box for approval before placing order. (b) The quoted rate including necessary excavation and PCC work for erection of LT jn box, gland, thimbles etc complete
Excavation in trenches, in soft/loose soil not exceeding 1.5 m deep and not exceeding 1.5 m in wide for laying of cable, RCC Poles/stays and struts etc and getting out including trimming sides and forming bottom surface complete all as specified and directed.
Returning, filling-in, including spreading, watering and well ramming in layers not exceeding 25 cm thick each, in soft /loose soil complete all as specified and directed
M & L for sand cushioning to underground cable including punning down of sand in layer complete all as specified and directed. Note :- Punned down thickness shall be measured for payment
M&L for laying common burnt bricks, sub class 'B', of size 230 x 115 x 75 mm in trenches for cable protection complete all as specified and as directed.
M&L Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting complete all as specified and directed
M&L for Earthing complete with earth galvanized steel plate electrode 600x600x6mm buried directly in ground earth pit not less than 2.25 mtr below ground level with top edge of the plate not less than 1.5 mtr below ground level, surrounded from all sides with mixture of charcoal and common salt and electrode connected with galvanized earth lead GI strip 32X6 by means of bolts, check nut and washers of GI or steel, GI pipe light grade of 40 mm bore as protection pipe, GI strip of length not more than 7.5 mtr and connected to test point. GI pipe 20mm dia medium grade for watering, funnel with wire mesh, PCC pit and RCC (1:2:4) type B-1 for cover with 8 mm dia bar reinforcement both ways @ 140 c/c including excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr as shown on electrical plate No 3 of SSR 2009 complete all as specified and as directed.
M&L for Earthing complete with earth galvanized steel plate electrode 600x600x6mm buried directly in ground earth pit not less than 2.25 mtr below ground level with top edge of the plate not less than 1.5 mtr below ground level, surrounded from all sides with mixture of charcoal and common salt and electrode connected with galvanized earth lead 4 mm GI wire by means of bolts, check nut and washers of GI or steel, GI pipe light grade of 15 mm bore as protection pipe, GI wire of length not more than 7.5 mtr and connected to test point. GI pipe 20mm dia medium grade for watering, funnel with wire mesh, PCC pit and RCC (1:2:4) type B-1 for cover with 8 mm dia bar reinforcement both ways @ 140 c/c including excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr as shown on electrical plate No 3 of SSR 2009 complete all as specified and as directed.
Supply and fix Hot Dip galvanized octagonal poles of height 5 Mtr bottom 130 mm, top 70 mm, 3 mm thick and base plate 200 x 200 x 16 mm including 1 Mtr single arm bracket, M20 x 600 mm J-Type Foundation bolts with zinc coat set of 4 Nos with double nut and double washers and connector 4 pole with MCB connector with single pole 10 Amps MCB and suitable for XLPE cable entry upto size of 25 Sqmm Cable lugs including foundation and earth work as per OEM drawing with PCC complete all as specified and directed. (Note : (a) Contractor should submit the diagram of pole with foundation details as per manufacturer recommendation before placing the order for approval of Engr-in-Charge. (b) The poles should withstand the wind pressure upto 120 Km/Hr
Supply and fixing LED street light fitting with and including individual high power 45 watt LED new generation energy saving and environmental friendly long life LED street light made up of pressure die cast alu with secondary optics, suitable for outdoor use IP 66, connected with connecting cable complete all as specified and as directed
S&F in loop in-out junction box with non metallic FRP junction box suitable of size (Appx 350 x 250 x 150) with connector 4 way and including one MCB SP 6 A, 230V alongwith 2 Nos 'C' Clamps and back clamp made up of 20x3 flat iron and fixing on pole with necessary nuts bolts, washers, 2 Nos PVC cable glands of size not exc 4 core 25 sqmm, Cable lugs as required complete all as specified and as directed.
S&F 3 core 1.5 sqmm PVC Insulated and Round Sheathed Multi Core Bright Annealed Bare Copper Conductor Heavy Duty Industrial Cable of Voltage Grade 1100 Volts as per IS: 694:1990 complete drawn in Rigid PVC Conduit of medium grade including making necessary connection by using proper connecting spares complete all as specified and as directed.
Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat or circular stranded of size 6 Sqmm including taking down old unsv service cable complete all as specified and as directed.
Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat or circular stranded of size 4 Sqmm including taking down old unsv service cable complete all as specified and as directed.
M&L for GI pipe of size 40 mm dia light grade for cable protection under road/concrete/drains etc complete all as specified and as directed.
Cutting existing road/PCC/Drain for laying of cable including necessary earth work, excavation exc 600mm depth but not exc 1 mtr depth, wide exc 450mm but not 800mm including making as existing surface with PCC 1:2:4 type B1 using 20 mm aggregate, thickness of concrete is 200 mm and making good the disturbed surface to match with existing surface complete all as specified and directed.
G V N R CONSTRUCTIONS
DHANA CONSTRUCTIONS
BEST ENGINEERING
KR ENTERPRISES
CIVILEC ENGINEERING WORKS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .