Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹20.2 Laccepted-aoc | ₹20.2 L | accepted-aoc |
Tender Value
₹21.7 L
EMD Value
₹21,740
Closing Date
18 May 2026, 4:00 pmClosed
EE, Polavaram Irrigation Project Left Main Canal Division No 2, Dawlaiswaram
DOWLAISWARAM
Annual maintenance for Operation & maintenance of radial gates, Head sluice, Electrical equipment and Manual Establishment of Bhupatipalem Reservoir Project Head works for the year 2026-27
929448
Tender Notice No. 06/2026-27, Dt: 01.05.2026
OPEN - NCB
Electrical Works
ALLURI SETHARAMA RAJU
8 documents required · 8 mandatory
₹770
₹21,740
2 Jun 2026
4 May 2026
4 May 2026
Cost and supply of Grease for all purposes for gear boxes, bearings, tracks of gates, screw rods etc., for spillway and head sluices.
Cost and supply of Cardium compound for applying to the wire ropes of Spillway Gates.
Supply and transportation of ......... LED Street light Luminaire made of pressure diecast alluminium body with powder coated, having protective toughned glass, Supply Input voltage 120 - 270 V AC, P.F > 0.90, high power LED's having System efficacy > 100 lm/W and junction temprature < 70°C, with Ingrees protection IP66, Luminaire performance complies to IS 10322 (Part 5 / Sec-3), Driver surge protection 4KV, In house additional Surge protection 10 KV with optics distribution , THD<10% at 110 Volts AC, driver efficiency >90%, CCT: 3000K - 5700K, minimum CRI>70, etc., complete. Makes : As per list of recommended brands as category I. (b) 30W @ along the Earth dam & Gallery
(d) 60W @ along the Earth dam & Gallery
Supply of ………., Adjustable, Confirms to IEC 60947-2 and IS 13947-Part 1&2 having Breaking Capacity ………. with thermal magnetic release Panel Mounted.@ Generator Room Makes: Lauritz Knudsen (Formerly L&T)- D shine / Schneider-CVS/Legrand –(DP X3/DRX)/ Siemens- 3VL / Hager-h3/C&S -Winbreak/HPL-Techno (g)250A 3 Pole MCCB,36/35 KA
Supply of ,……... 10KA C/D Curve ISI Mark. Makes : Makes: Legrand-DX3 / Schneider-A9/Hager-h3/ Siemens-5SX4/ Havells STADx / Lauritz Knudsen (Formerly L&T)-AU/Indo Asian-Opti pro/ HPL (Techno) /Anchor (Uno Plus) (a) 6-32A SP MCB @Earth Dam street light poles
(c) 6-32A DP MCB @Hoist bridge
(f) 40-63A TP MCB @Right Gallery Panel
(h) 40-63A FP MCB @Left Gallery panel
Supply of……HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2 @Rope Drum Hoist bridge Makes :Makes: Lauritz Knudsen (Formerly L&T)/ G E / C & S / Standard / HPL / Havells / Siemens / Indo Asian (b)45A to 63A @Generator Room
Supply and Fixing of push button actuators and integral contact block of dia. 22.5 mm including making connection etc. as required@Rope Drum Hoist bridge Makes : As per list of recommended brands. (a)Non luminous type
Supply and Fixing of 240/220 V, LED (22.5 mm dia ) Pilot lamp with integral circuit, terminal block, including connection etc. as required @Rope Drum Hoist bridge (a)Red/yellow/Green colour
PVC /cotton tape Role ( 8 Mtrs)
Supply and Transportation of XLPE/PVC insulated & PVC sheathed armoured cables of 1.1 KV grade with copper conductor as per IS 7098 Part-I -1988 etc complete. Make: Torrent / Universal / Unicab / Havells / KEI /Polycab/Gloster/Orbit/ Paragon/RR Kabel /RPG /Rhino /Pawancab/AKG/LS cable/ Polywires (l) 4C x 6 sq.mm
Supply and fixing of 20-24W, not less than 1100mm length LED batten light with extruded aluminum housing and polycarbonate cover, input voltage AC 220 - 260 Volts, with high power LEDs, having System Efficacy of >=100 lumens/watt , PF>0.9, Surge protection: 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 5700K, minimum CRI>70, etc., complete with earth connection and not less than two years warranty.@Lascar Quarters & Generator Room Makes: a) LUMINAIRE MAKE : Phillips / GE- Venture / Crompton / Wipro / Bajaj / Havells /Jaquar b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG/ Everlight.
Supply of 48" (1200mm) Sweep 5 star rated BLDC (Brush less Direct Current) Ceiling Fan with double ball bearings, input voltage 230V AC converted to 24 V DC, power input not more than 32W , air delivery 210/220 cubic meter/min with remote and without Regulator.@Instrumentation Room Makes: Atomberg(GV2 )/ Halonix(Plasma) /Havells(Efficiencia Neo)/ Crompton(EN Groove)/Superfan(E281)/RJP(Ecowise)
Supply of 3 Core…………ISI marked Flat Copper cable of ISI for Submersible Motors confirming to IS: 694:1990. @ from starter panel to Gallery submersible motor Makes: Finolex / Polycab / Havells/ Lauritz Knudsen (formerly L&T) (c) 4 sq.mm
Supply and making end termination with heavy Alluminium lugs (pin/ ring type) as per IS specification duly crimped with crimping tool, PVC tape etc of following size@Spillway Bridge & Hoist bridge (a) up to 16 sqmm
Supply and Transportation of ……... Three phase open well ISI submersible motor pumpset confirms to IS 14220: 1994.@Gallery . Makes: Makes: Kirloskar / Crompton / Texmo / CRI / 10.00HP (100x75)
Rewinding of ceiling fan motor (starting and running winding) including all necessary material. The motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enameled wire with 'E' class insulation material and making connections etc. as required.@Generator Room & Lascar Quarters (New model ceiling fan) 900/1200 mm sweep
Supply of Semi Skilled category Helper for routine and regular works like taking gauge readings, keeping the reservoir site clean, removal of weeds, ant hills and maintenance of earthen embankment slopes, greasing and oiling of spillway gates, operation of spillway gates & gantry crane, regulation of head sluice gate, operation of diesel generating sets, dewatering of gallery, operation of dam lighting, operation of drinking water motor and other works as directed by the engineer-in-charge 2 Nosx365days = 730
Supply of Electrician ( Licensed ) for maintanance works of spillway gates, gantry crane, Generators, gallary dewarering, lighting system ect. connected to Bhupatipalem Reservoir Project and as directed by the engineer-in-charge 1 Nosx365days = 365
Supply of Electrician ( Licensed ) for maintanance works of spillway gates, gantry crane, Generators, gallary dewarering, lighting system ect. connected to Bhupatipalem Reservoir Project and as directed by the engineer-in-charge 1 Nosx365days = 365
Supply of Watchmen Un-Skilled category for the day and night watch and ward of the Bhupatipalem Reservoir Project Head works 3 Nosx365days = 1095
Clearing thin jungle growth ( more than 50 percent open space ) including bushesupto 30 cm / parthenium and other weeds including burning or disposing off the same as directed etc., complete.
Cleaning drainage gallery, adits, instrumentation galleries etc., by scrubbing / brushing including chiselling and removing leached lime deposit and disposing off all the waste material out side adits in specified location etc., complete with all leads and lifts.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
6DECLARATION.pdf
TENDER_DOCUMENT • 0.91 MB
Booklet.doc
TENDER_DOCUMENT • 0.32 MB
BOQItemswb.xlsx
TENDER_DOCUMENT • 0.17 MB
Schedule A.xls
TENDER_DOCUMENT • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .