Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.3 LAccepted-AOC | ₹28.3 L Quoted ₹58.9 L | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹59.0 L+₹10,000 (0.17%)Rejected-Finance | ₹59.0 L+₹10,000 (0.17%) | L2 | Rejected-Finance Not L1 bidder |
| 3 | Rejected-Technical | - | - | Rejected-Technical Doc related to approval of Sub Contractor against submitted Work Ex doc issued from M/s Arihant Con World were not submitted (The same were required as per PQC Criteria clause 5.2). Form 26AS / TDS certificates not submitted |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
12 Dec 2023, 4:00 pmClosed
Project Head , HURL SINDRI
HURL Sindri, Old FCIL Complex,Sindri, Dhanbad
Signal and Telecommunication (S and T) Maintenance works of In-plant at Railway Yard and Associated facilities for a period of 01 year at HURL Sindri
2023_HURL_781887_1
HURL/Sindri/CnM/23-24/854
Open Tender
Miscellaneous Services
Tender cum Auction
365 days
HURL SINDRI
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹50,000
Yes
2 Jul 2024
21 Nov 2023
13 Dec 2023
21 Nov 2023
12 Dec 2023
21 Nov 2023
21 Nov 2023 - 12 Dec 2023
Amount
Signal & Telecommunication (S&T) Maintenance works of In-plant at Railway Yard & Associated facilities for a period of 12 months at HURL Sindri
AMC of Signal & Telecommunication (S&T) Maintenance works of In-plant
PVC insulated Railway Signalling Indoor Single core cable as per colour coding scheme of Railways conforming to RDSO Specification No: IRS:5-76/89 (Amd. 3) with latest amendment.
16 x 0.2 mm.(Grey)
7 x 0.75 sq.mm.
Desk ape Electronic Magneto Telephone
G.I. Bond wire soft 8 SWG for bonding resistance -132 ohm/Km.
Push Button for Panel Operation (Red,YeIIow,Grey,Black & white-2 nos each)
Lead Acid Low Maintenance Secondary Cell 2V/80 AH as per RDS0 specn.IRS:S- 88/93.(materials should be procured from RDSO approved firm).
Axle Oil
Hydrometer of standard size of Exide make OF similar.
Resin core solder soft.For sophisticated soldering
Cable Railway Signalling Unscreened underground with plain annealed copper conductor, armoured PVC insulated to conform to IRS:5- 63/2014 (Rev.4.0) or with latest amendments. 12 core x 1.5 sq.mm.
Railway underground Jelly filled 6 Quad Telecom Cable as per Spec. No. IRS:TC 30/2005 (Ver. 1) with Amd. 4 or latest amendment having 0.9 mm dia.
Non deteriorating, non indicating type Fuse Cartridge as per IRS-S-78/92 with latest amendment.
LED Main signal as per RDSO spec RDSO/SPM/153/2004 or latest with HMU .( From RDSO approved Firm)for the following; a) RED aspect
b) Yellow aspect
LED aspects for shunt signal with built in current regulator as per RDSO spec RDSO/SPM/153/2004 or latest with amdt-1 or lattes.( From RDSO approved Firm)
ROUTE LED signal lighting unit, 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specification No. RDSO/SPN/153/2011 (rev 4 1) .
Lead Seal & Sealing Wire.
LED with Holder for domino type panel(Red,yellow & white of 10 nos each kind)
Tools & Plants of reputed make:
Cutting Plier 200mm(Taparia Make) insulated.
Round nose Plier 150mm (Taparia Make) insulated.
Screw Driver set with common handle.(Taparia Make)
Digital Multi Meter having (a) 0-1000V AC/De. (b) 0-10A, O0-1000 ohms,(d) 3-1/2 digits.The Multimeter shall be supplied with Rest Probe, Lather cover,battery and is of MOTWANE/MECO/Metrvi(XB-33C) or similar make.
Relay Plug in type, Sale AC-LED: all aspects AC Lamp Proving Relay unit with built in current transformer ape slow to release Neutral Line Relay 4F/4B contacts front and back metal to carbon shall be suitable for working in series with 110 V A. LED Sign Signal rated at 15 W conforming to RDS0 Spen. No.STS/E/Relay/AC lit LED Signal /04-2002. BRS;941A, IRS-S-34 & IRS-S-23/86 (as applicable)
Insulation set for Gauge/Xing tie plates for BG l3 S per IRS-S-40/84. Each set comprising of: Splice plate - 2 Nos. Bushes 6 Nos. Washers 12 Mos.
Insulation set for following & leading P way stretcher bar for BG as per IRS-5-40/84. Each set comprising of: Insulating plate - 2 Nos. Bushes 4 Nos. Washers 4 Nos.
Insulation set for Switch extension pieces (D/P bracket) for Point Machine as per IRS-S- 40/84. Each set comprising of: Side plate LH - 2 Nos Side plate RH - 2 Nos. Bushes - 8 Nos. Washers - 8 Nos. Insulation set for L Bracket. Each set comprising of: Insulation Plate -1 no. Nylon Bush- 2 Nos. Nylon Washer- 2 Nos.
Relay, Non-AC immune, plug-in type, Style ” QN1'. DC Neutral line, 24V, 12F/4B contacts. front and back contacts metal to carbon with plug board, retaining clip & connectors conforming to BRS:930, IRS:S 34 & IRS:S 23 (as applicable). The interlocking code for this unit shall be ABCDE
Relay, Non-AC immune, plug-in type, Style ”QN1'. DC Neutral line, 24V, 8F/8B contacts, front and back comes metal to carbon with plug board, retaining clip & connectors conforming to BRS:930. IRS:S 34 & IRS:S 23 (as applicable). The interlocking code for this unit shall be ABCDF.
Relay, AC Immune, plug-in type, Style “QNA1”. DC Neutral line, 24V, 12F/4B contacts, front and back contacts metal to carbon with plug board, retaining clip & connectors conforming to BRS:931 A, IRS:S 34 & IRS:S 23 (as applicable). The interlocking code for this unit shall be ABDGH.
Relay, AC Immune, plug-in type, Style “QNA1”. DC Neutral line, 24V, 8F/8B contacts, front and back contacts metal to carbon with plug board, retaining clip & connectors conforming to BRS:931A, IRS:S 34 & IRS.S 23 (as applicable). The interlocking code for this unit shall be ABDGH
Relay DC miniature magnetically latched neutral line tractive armature 24V DC 11F/4B Front & Back contacts Metal to Carbon complete with plug board, retaining Clip & connectors to BRS 935A,IRS-S-34.IRS-S-23. style QL1
Fail-Safe Electronic timer, 24 V DC, 120 Sec as per RDSO specification IRS: S-61/2000 (Amd 2) with latest amendments.
Relay AC Immunised, DC miniature , Plug in type, Neutral Line, Slow to Release Tractive Armature 24 V DC 8F/ 4B contact, Front & Back contracts Metal to Carbon complete with plug board, retaining clips and connectors etc. to BRS 933A ,IRS-S-34,IRS-S-23 (as applicable). Style QSPA1.
Fail Safe Electronic Flasher Relay 50 Flashes Per minute (workable on 24V DC) Device 3 Amp. for Railway Signalling as per RDSO Specification No. RDSO/SPN/173/2002 with Amendment No. 1 Latest. (With Galvanic Isolation). Inspection: RDSO Inspection: RDSO
Electrical Point Machine (143 mm throw) heavy duty Nontrailable Rotary Locking type complete with cable terminal box as per IRS-S- 24/2002 (Amd. 1) & Drg. No. RDSO/S - 10800. Machines operate on 110V DC.
Rotary Key Transmitter (RKT) as per Spec. No.: IRS:S-21/2001, Drg. No.: SA-22601 (Alt 4).
Fuse block made of PBT as per RDSO specn. No. IRS:S-75/2006 (Rev.2) & drg.No. SA-23748 (Alt. 4). Non deteriorating fuse links knife edge type with suitable fuse carrier and box.
Excavation of Trench, Depth 1.0 Mtr. & width 0.3 Mtr , in all soils including soft rocky area and clearing of roots of trees, bushes, rocks etc., ballast and reconditioning etc., (including bailing out water and disposal of extra soil) including back Billing with excavated earth and ramming of trenches after cable laying for the following depth and width as given below. The contractor has to conduct detailed site survey of the cade route as per Drg.ND.RITES/SIG/GEN/021-98. Prepare a plan to get approval of the owner's authorised representative, putting white lime powder marking before excavation of earth under supervision of owner's authorised representative. Wherever several cables of different categories have to be laid in the same path, all cables shall be separated with brick through out the length, instead of seperate trench in the concerned area. This work includes : a)Covering of laid cables in trenches by a layer of 50 mm thick Ioose soils before covering by split DWC pipe approximately. b)Disposal of soils, clearing of roots, bushes etc. in all types of soils. c)Cable route markers are to be laid along with the cable route as per instruction of site Incharge.
Transportation & Laying of all apes of cables i.e. Signalling cables of various sizes / Power cables/ 6 Quad cades in the excavated trench as per cable chart & technical specification as Drg. No. RITES/SIG/GEN/021-98. This includes supply of U clamp & anchoring the cable with U clamp at an interval of 25 metres as per Drg. No. CSTE/CON/Cable/81.
Track crossing by excavation of trench, earth work and reinstatement of Track after cable laying, as per the instruction of site Engineer. Cable to be laid through DWC Pipe.
Painting no coats of enamel paint over one coat of Red oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer & paints both of approved quality are to be supplied by Contractor.
Welded Steel Apparatus Cases. NOTE: Location Boxes (Full & Hall to be painted with Anti Corrosive Paints as per IS:9862-1981, one and half feet from the bottom, on all surfaces - Both inside & outside.
Main Signal post with signal unit, Jn. surface complete with Route indicator fittings as per Rlys. standard practice. This includes dependent, Independent shunt Signals also as enclosed above.
Point Machine with ground connections complete (point machine with black enamel only outside & ground connexion with Red oxide).
Lettering/Numbering Df Signals, Points, Apparatus case, TUB, etc.
Charging of lead acid batteries with contractors own battery grade sulphuric acid & distilled water with minimum 3 charge/ discharge cycles. Installation of charge batteries in group there connection & wiring. The sulphuric acid & distilled water to be used for charging shall conform to specn IS 266-1961 & IS 1070-1960. All materials required for charging will be supplied by the contractor.
Any other item (Technical or Non-Technical) which has been covered / not covered in Schedule "B"of woks will be operated from the similar items of accepted valid work-order or contract agreement of RITES or Railways or market rate analysis. (e.g.condenser,diode,resistance etc.etc.)
Bidder Name
Amount in Words
Sukanksha Construtions
M/S U R Enterprise
M/S U R Enterprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .