Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹92.9 LAccepted-AOC 801 VENUS BENECIA PAKVAN DINING LANE OPP RAJPATH CLUB S G HIGHWAY BODAKDEV AHMEDABAD 380053 | AHMADABAD | GUJARAT | 380053 | L-1 | Accepted-AOC Lowest Bidder | |
| 2 | L-2₹93.6 L+₹74,698 (0.80%)Rejected-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L-2 | Rejected-Finance Quoted High | |
| 3 | L-3₹93.7 L+₹79,658 (0.86%)Rejected-Finance PLOT NO 113 GURUSANGAT DARBAR ROAD SINDHI COLONY KHAMLA NAGPUR 440025 | NAGPUR | MAHARASHTRA | 440025 | L-3 | Rejected-Finance Quoted High | |
| 4 | L-4₹96.5 L+₹3.7 L (3.96%)Rejected-Finance C O BABA GULKARI FLAT NO C 57 SHANKARRAO PADHYE APARTMENT WARDHA ROAD SAVITRI VIHAR SOMALWADA NAGPUR 440025 MH | NAGPUR | MAHARASHTRA | 440025 | L-4 | Rejected-Finance Quoted High | |
| 5 | L-5₹97.0 L+₹4.1 L (4.44%)Rejected-Finance 1001 SHIVALIK ABAISE 100 FEET ROAD OPP ANANDNAGAR APARTMENT PRAHALADNAGAR AHMEDABAD AHMEDABAD GUJARAT 380015 | AHMADABAD | GUJARAT | 380015 | L-5 | Rejected-Finance Quoted High |
Tender Value
₹1.1 Cr
EMD Value
₹2.2 L
Closing Date
4 Apr 2022, 3:00 pmClosed
AGM (Engg-Elect)
Birsi Airport, Gondia
Bi-Annual Operation and Maintenance Contract for the E and M Installations, WTP etc at Birsi Airport, Gondia for the Year 2022-24
2022_AAI_108830_1
AAI/Gondia/E-E/2021-22/NIT-07
Open Tender
Miscellaneous Services
Item Rate
730 days
Maintenance/Gondia
As per NIT
4 documents required · 4 mandatory
₹1,180
Yes
Airports Authority of India
₹2.2 L
Yes
9 Jun 2022
8 Mar 2022
5 Apr 2022
8 Mar 2022
4 Apr 2022
16 Mar 2022
8 Mar 2022 - 16 Mar 2022
Amount
Periodical Maintenance of Electrical Installations of operational and non operational area such as GLF System, CCR, CNS installations building, DG Sets with AMF Panels, Mobile DG Sets, Terminal Building, Power Supply Systems, 11KV Sub-Station, Pump Sets, High Mast Towers, Approach Roads & Car Parking Lights, Internal & External E.I of Technical block cum ATC Tower, Power House, Fire station, MT Pool, Water Treatment Plants etc. involving Operation, repairs & maintenance, Faults / breakdown rectifications, ensuring serviceability/Satisfactory working conditions of the system, attending complaints, preventive maintenance on daily / weekly / monthly / Quarterly / half yearly / yearly basis maintenance of records/documentation etc. as per scope of work given in special conditions of contract on all days including Sunday & Holidays. The services of DG Sets, AMF Panels at power House shall be ensured round the clock (i.e. in three shifts daily, each shift of 8 hours) and the services of all others E&M Installations shall be ensured for two shifts (each of 8 hours) daily as required.
Rewinding Servicing repairing of ceiling fan/ wall fan including replacement of bearings if required and to & fro transportation etc complete as required (Dismantle Material belongs to contractor).
1st Year
2nd Year
Rewinding Servicing, repairing of Exhaust fan/ Air Circular fan of size upto 450 mm sweep i/c replacement as bushes/bearings if required and to & fro transportation etc complete as required. (Dismantle Material belongs to contractor)
1st Year
2nd Year
Rewinding of the motors (Capacity from 3 HP and upto 5 HP), Which are suitable to operate on 415V, 50Hz, 3Ø AC supply, with suitable gauge copper wire i/c warnishing, bearing if required etc as required i/c transportation from site to workshop & back to site. (Dismantle Material belongs to contractor).
1st Year
2nd Year
Repair and rewinding of submersible pump motor set up to 5 HP capacity. Job include transportation of motor dismantling and rewinding with the same gage insulated copper wire including replacement of all the internal worn out/defective parts i.e bushes, impellers, sleeves, upper and lower bush sets, thrust bearing, oil seals, rotor grinding and balancing, assembling, testing, transportation etc. complete as required.
1st Year
2nd Year
Lifting & Lowering of submersible pumps of various capacities (up to 5 HP) due to defect in existing pump / pump choked in existing borewell on urgent basis within a short notices including connection of cables jointing of cables etc. with successful testing &commissioning complete as required.
1st Year
2nd Year
Execution of work as per CPWD DSR 2018 (E&M). NOTE: The firm has to quote/upload the percentage above / below (+/- % on the quantity mentioned against BOQ item No. (7) directly in the form of multiplying factor in the rate column as clarified below: For example, “if agency desired to quote 5% above on CPWD DSR-2018 (E&M) rates, the rate column shall be filled as 1.05. If agency desired to quote to 5% below on DSR-2018 rates, the rate column shall be filled as 0.95.”
Inspection, Servicing and Testing of 800A capacity 11 KV Vaccum Circuit Breakers (Make - CGL) including CTS PT wiring, other carrying out tests & preventive maintenance through authorised service agent and submission of test reports complete job as per attached technical specification.
1st Year
2nd Year
Inspection, servicing, setting, calibration and testing of IDMT relays, Make - Easun Reynode, Model - 04574 (set of 2 over current + 1 earth fault) i/c carrying out tests & preventive maintenance through authorised service agent and submission of test reports complete job as per attached technical specification.
1st Year
2nd Year
Inspection, servicing, setting, calibration and testing of auxiliary and tripping relays including carrying out preventive maintenance through authorised service agent and submission of test reports complete job as per attached technical specification.
1st Year
2nd Year
Inspection, servicing & testing of following Air circuit breakers of Capacity up to 1250A including carrying out the testing and preventive maintenance through authorized service agent and submission of test reports complete job as per attached technical specification.
1st Year
2nd Year
Dehydration and filtration of transformer oil at site (Transformer Make: Indotech, Capacity 500 KVA, Oil Capacity 1050 Ltrs.) including testing the BDV and acidity before and after testing, topping of oil and submission of test reports etc. as required for following Transformers complete job as per attached technical specification.
1st Year
2nd Year
Supply of transformer oil of IS: 335/1980 ammended upto date with test report as required.
1st Year
2nd Year
Recharging of pebble and graded sand filter of capacity 10,000 ltrs / Hr. by replacing the sand from existing pressure vessel of size 700 mm dia, 2000 mm height etc. as per site reqirement (NIATAM).
1st Year
2nd Year
Recharging of pebble and graded sand filter of capacity 3000 ltrs / Hr. by replacing the sand from existing pressure vessel of size 400 mm dia, 1250 mm height etc. as per site reqirement (Airport & AAI Colony).
1st Year
2nd Year
Recharging of activated carbon filtration system of capacity 10,000 ltrs./Hr. replacing activated carbon from existing pressure vassel of size 800 mm dia, 2000 mm height etc. as per site requirement (NIATAM).
1st Year
2nd Year
Recharging of activated carbon filtration system of capacity 3000 ltrs./Hr. replacing activated carbon from existing pressure vassel of size 400 mm dia, 1250 mm height etc. as per site requirement (Airport & AAI Colony).
1st Year
2nd Year
Rewinding and servicing of 370W, 0.5HP, Single phase Motor which are suitable to operate on 230V, 50Hz, AC Supply, with suitable gauge copper wire including warshining, bearing etc. as required. Including transportation from site to workshop & back to site. (include less rebate of dismantled copper wire)
1st Year
2nd Year
Supply of 40W, 4 Pin, Single Ended Tubular Ultra Voilet Tube Lamp suitable for single phase 230V, 50Hz, AC Supply.(Similar to Model TUV 36T5 HE 4P SE, Make Philips)
1st Year
2nd Year
Supply of 40 Watt, Electronic Ballast for TUV Fixture Suitable for Single Phase, 240Volt, 50Hz, AC supply (Similar to Model No. HF-P 158TL-D III 220-240V 50/60 Hz, Make Philips)
1st Year
2nd Year
Supply of 40 Watt, 4 Pin, T-5 TUV Lamp Holder suitable for Single Phase, 240Volt, 50Hz, AC supply (Similar to Model No. G10Q 4-PIN, Make Philips )
1st Year
2nd Year
Supply of Aluminium Sulfate (Alum) suitable for water treatement. (KAI(SO4)2-12H2O)
1st Year
2nd Year
Supply of Calcium oxychloride (Bleaching powder) suitable for disinfecting of drinking water. (CAOCl2)
1st Year
2nd Year
Spray Painting of sand filter cylinder,activated carbon filter cylinder and Tube setteler applying two coats of syntetic enamel paint of approved make including cleaning of surface by sand paper and thereafter applying red oxide to obtain even shade etc complete as per satisfaction E-I-C as required.
1st Year
2nd Year
Providing and placing on terrace (at all floor levels) polyethylene water of 5000 Ltr. storage capacity tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes with fittings and the base support for circular tank.
1st Year
2nd Year
Manish Electricals
M/s BHARAT ELECTRIC, NAGPUR
M/s LEESHA ELECTRICALS
CENTRE TAP ENGINEERING
Techno Electricals
S.K ENTERPRISES
SHRADDHA ENGINEERING AND FACILITY SERVICES
CIS GLOBAL INFRATECH PRIVATE LIMITED
PREMIER ENGINEERING TECHNICS PVT. LTD.
Comfort Zone
Ascent Electrification Engineers
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .