Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC H NO 05 AASI BAUG OPP VATSALYA SCHOOL BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L1 | Accepted-AOC Lowest and reasonable | |
| 2 | L2₹14.7 L+₹4.3 L (41.8%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹14.8 L+₹4.4 L (42.4%)Rejected-Finance | L3 | Rejected-Finance Not Lowest |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
26 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Army Bhuj
GE Army Bhuj, Madhapar Road, Bhuj-Kutch, Gujarat- 370 001
REPAIRS / CLEANING OF SEWAGE LINE, SEPTIC TANK, SOAK WELL UNDER AGE B/R-I (ARMY) BHUJ AT MIL STN BHUJ
2021_MES_445829_1
8815/E8
Open Tender
Civil Works
Item Rate
270 days
Bhuj Mil Stn
As Per Tender
7 documents required · 7 mandatory
₹500
GE Army Bhuj
₹30,000
Yes
14 Jul 2021
25 May 2021
28 Jun 2021
25 May 2021
26 Jun 2021
10 Jun 2021
60 days
Amount
Taking out liquid sludge including floating sludge contents from septic tank of any description and in any position and cleaning septic tank up to bottom including walls at any depth from ground level by pumping through sewage disposal pump / honey sucker pump ( as directed by the Engr-in-charge and as on required basis) and removing the liquid sludge outside of the MD land or nearer manhole of civil sewage line in such a manner that there shall be no nuisance and no unhygienic environment complete all as specified and directed. Note: Pump , honey sucker pump and sludge removal van / vehicles shall be arranged by contractor at his own cost and nothing extra shall be governed by the Deptt.
Taking out sedimented sludge left out after taking out and removing liquid sludge/effluent , from septic tank of any description, in any position and of any depth, removing the sludge depositions as directed, cleaning septic tank up to bottom, including walls and removing and disposal of the sedimented/solid sludge at any depth to a distance of n.exc 250 mtr distance and burying in ground complete all as specified and directed by Engr-in-Charge. Note: Pump , honey sucker pump and sludge removal van / vehicles shall be arranged by contractor at his own cost and nothing extra shall be governed by the Depth.
Cleaning of existing chocked/ blocked sewage lines of 150mm bore, of any description and in any position by taking out loose sediment sand, girt, ash, sludge water, rags, fibre or vegetation from the sewage line to any depth from GL including removal of sludge/debris outside of MD L and in such a manner that there shall be no nuisance and no unhygienic environment at the place of disposal complete all as specified and directed Note: Pump , honey sucker pump and sludge removal van / vehicles shall be arranged by contractor at his own cost and nothing extra shall be governed by the Depth.
Cleaning of existing chocked/ blocked sewage lines of 200mm bore, of any description and in any position by taking out loose sediment sand, girt, ash, sludge water, rags, fibre or vegetation from the sewage line to any depth from GL including removal of sludge/debris outside of MD L and in such a manner that there shall be no nuisance and no unhygienic environment at the place of disposal complete all as specified and directed Note: Pump , honey sucker pump and sludge removal van / vehicles shall be arranged by contractor at his own cost and nothing extra shall be governed by the Depth.
Cleaning of existing chocked/ blocked sewage lines of 300mm bore, of any description and in any position by taking out loose sediment sand, girt, ash, sludge water, rags, fibre or vegetation from the sewage line to any depth from GL including removal of sludge/debris outside of MD L and in such a manner that there shall be no nuisance and no unhygienic environment at the place of disposal complete all as specified and directed Note: Pump , honey sucker pump and sludge removal van / vehicles shall be arranged by contractor at his own cost and nothing extra shall be governed by the Depth.
Opening and cleaning of blockage of kitchen/bath traps or WC any pattern and in any position by rodding, manually or mechanically upto 1st manholes as directed by Engr-in-charge and as on required basis) complete all as specified and directed.
Cleaning of blocked manhole of any description and in any position depth n exc 1.5 m deep mechanically or manually by taking off sludge waste /night soil and silted soil from the existing manhole of any size collecting and removal of sludge in sealed container out of the cantonment area in such a manner that there shall be no nuisance and no unhygienic environment at the places of disposal area complete all as specified and directed.
Cleaning of blocked manhole of any description and in any position depth exc 1.5 m but n exc 3m deep mechanically or manually by taking off sludge waste /night soil and silted soil from the existing manhole of any size collecting and removal of sludge in sealed container out of the cantonment area in such a manner that there shall be no nuisance and no unhygienic environment at the places of disposal area complete all as specified and directed.
Cleaning of blocked manhole of any description and in any position depth exc 3.0 m deep mechanically or manually by taking off sludge waste /night soil and silted soil from the existing manhole of any size collecting and removal of sludge in sealed container out of the cantonment area in such a manner that there shall be no nuisance and no unhygienic environment at the places of disposal area complete all as specified and directed.
Excavation in trenches n.exc. 1.5m wide and n.exc 1.5 m in depth for foundation for laying /taking down sewage / water supply lines , forming bottom surfaces to required slope & gradient and n.exc 10sqm on plan and n 'exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed
Excavation in trenches n.exc. 1.5m wide and exc 1.5 m & n exc 3m in depth for foundation for laying /taking down sewage / water supply lines , forming bottom surfaces to required slope & gradient and n.exc 10 sqm on plan and getting out in any type of soil complete all as specified and directed
Demolition and breaking up drain pipes (glazed stone ware, AC or reinforced concrete),150 mm dia pipe of any description and in any position set and jointed in cement mortar AND S&F jointing and testing for reinforced concrete drain pipes, 150mm bore, class NP-2, laid and jointed with collar in CM (1:1) complete all as directed
Demolition and breaking up drain pipes (glazed stone ware, AC or reinforced concrete),200 mm dia pipe of any description and in any position set and jointed in cement mortar AND S&F jointing and testing for reinforced concrete drain pipes, 200mm bore, class NP-2, laid and jointed with collar in CM (1:1) complete all as directed
Demolition and breaking up drain pipes (glazed stone ware, AC or reinforced concrete),300 mm dia pipe of any description and in any position set and jointed in cement mortar AND S&F jointing and testing for reinforced concrete drain pipes, 300mm bore, class NP-2, laid and jointed with collar in CM (1:1) complete all as directed
M&L for concrete bed to drain pipes in cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) including packing under, and haunching against the side of the pipes after they are laid tested for pipes of 150mm dia complete all as specified and directed
M&L for concrete bed to drain pipes in cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) including packing under, and haunching against the side of the pipes after they are laid tested for pipes of 200mm dia complete all as specified and directed
M&L for concrete bed to drain pipes in cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) including packing under, and haunching against the side of the pipes after they are laid tested for pipes of 300mm dia complete all as specified and directed
Demolition of pre-cast concrete block masonry built in cement mortar of any description in any position and M&L for precast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar 1:6 complete Type B-1, 1:5:10 (20mm graded aggregate and 12.50 mm in the ratio complete all as specified and as directed.
M&L for rendering 15mm thick in cement mortar (1:4) on concrete/ fair surfaces of block masonry, finished even and smooth without using extra cement with and including mixing water proofing compound as per manufacturers instructions complete all as specified and as directed. Note: Water proofing compound shall be measured and paid for separately under appropriate item of Sch "A' as supply only on requirement basis
M&L for PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in coping exposed surfaces finished even and smooth using extra cement including necessary form work complete all as specified and directed.
M&L for PCC 1:2:4 type B1(using 20mm graded aggregate) as in benching of surface channels/manholes including fair finishes of surfaces chamfering, throating and weathering and necessary form work complete as specified and directed.
Demolition of RCC manholes covers of any description and in any position AND M&L pre-cast cement concrete 1:2:4 type B1 (using 20 mm graded aggregate) for manholes covers duly engraved "MES" marking including placing in position and set in cement mortar (1:3) complete all as specified and directed.
M&L for mild steel TMT 10mm dia and over as in reinforcement cut to length bent to shape required including cranking etc and binding with MS wire (annealed) not less than 0.9mm dia complete all as directed.
Returning ,filling in including spreading levelling watering and well ramming in layers not exc 25cm thick in soil in any depth complete all as specified and directed.
Removing excavated soil/ materials to a distance not exc 50 mtr and depositing where directed at a level not exceeding 1.50 m above the starting point complete all as directed.
Demolition of cement concrete of any description and in any position (unreinforced) in ground floors/ paving not exceeding 15 cm thick (below or above GL) and disposing rubbish off the premises of cantonment complete all as specified and directed.
M&L for PCC (1:3:6) type C2 using 40mm graded stone aggregate as in foundation of manholes, mass concrete etc. complete all as directed.
M & L Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1) smooth finished, and reforming benching as required for 150 mm dia of pipe complete all as specified and directed.
M & L Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1) smooth finished, and reforming benching as required for 200 mm dia of pipe complete all as specified and directed.
M & L Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1) smooth finished, and reforming benching as required for 300 mm dia of pipe complete all as specified and directed.
S&F Vitreous China, wash down water closet pan "Pedestal pattern" white including connection to drain and to flush pipe and anti syphonic pipe including all joints and making good the disturbed surfaces complete all as specified.
S & F vitreous china squatting pan, Orissa pattern, size 580 x 440 mm white with integral foot rests and connection to trap and to flushing pipe, anti syphonage pipe etc (excluding flushing cistern and flush pipe) complete with provision of lime concrete bedding including & fixing new WC in repair and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed.
Dismantling floor, hearth or wall tiling of any description and in any position including cement mortar bedding (but not backing) and M&L for non skid designer and concept ceramic tiles, joint free, coloured tiles 7mm to 8 mm thick (Square or rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile laid over and includin screed bed or bedding layer of mortar 15 mm thick in cement mortar (1:4 ) complete all as specified and directed.
Dismantling floor, hearth or wall tiling of any description and in any position including cement mortar bedding (but not backing) and M&L for glazed ceramic tiles, coloured tiles, 200mm x 300mm x 7mm thick on vertical faces ie. as in skirting/dado etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles fix over and including 10 mm thick backing coat in cement mortar (1:4) complete all as specified and directed.
Taking down eaves gutters and rain water pipes (any size 75mm to 110mm of any pattern) ,of any description and in any position, including all fittings , heads, shoes, bends, swan necks, etc., (measured overall as fixed along the centre line over fittings and accessories)complete all as specified.
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring jointsfixed on walls complete all as specified and directed
S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring jointsfixed on walls complete all as specified and directed
S&F PVC (SWR) bends, 110 mm bore, any radius with access door complete all as specified and directed.
S&F PVC (SWR) bends, 75 mm bore, any radius with access door complete all as specified and directed.
S&F PVC (SWR) Junction, single, (single T) equal or unequal with access door, 75 mm bore, complete all as specified and directed.
S&F PVC (SWR) Junction, single, (single T) equal or unequal with access door, 110 mm bore, complete all as specified and directed.
S&F PVC (SWR) Junction, single, (single Y) equal or unequal with access door, 75 mm bore, complete all as specified and directed.
S&F PVC (SWR) Junction, single, (single Y) equal or unequal with access door, 110 mm bore, complete all as specified and directed.
S & F grating square 150mm size of PTMT (minimum weight 100) complete all as specified and directed.
M&L for PVC (SWR) vent cowl, 110 mm bore complete all as specified and directed.
M&L for PVC (SWR) vent cowl, 75 mm bore complete all as specified and directed.
Surface dressing n.exc 15 cm deep complete all as specified and directed.
Supply only water proofing compound all as specified and directed. Note :- The retreived materials have been mentioned in the Sch of credit in the tender documents in pdf form. The amount of Sch of credit will be deducted offline from the amount of BOQ at the time of acceptance.
BHAVANI PROVISION STORES
M/s J K Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .