Loading…
Loading…
Tender Value
Refer Docs
Closing Date
5 Jun 2026, 11:00 amDue today
M(SRC-OS)
HSL
OVERHAULING OF HPAC LUB OIL AND AIR COOLERS INTER STAGE COOLERS) ON INS PROJECT
2026_HSL_99581_1
SR COMPLEX/PRODUCTION/OUT SOURCEREQUISITION/2026/145
Open Tender
Miscellaneous Services
30 days
HINDUSTAN SHIPYARD LIMITED, VSP
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
Exempted
2 Jun 2026
2 Jun 2026
5 Jun 2026
2 Jun 2026
5 Jun 2026
2 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Overhauling of HPAC Lub oil and Air Coolers(inter stage coolers) The following coolers to be removed from the position,shifted to workshop,dismantled,chemically cleaned,inspection to be carried out,required tubes to be blanked,pressure tested at shell side and tube side,showned to ship staff,assembled with new gaskets,seals and fasteners,painted,fitted in position,satisfactory operation to be showned to ship staff.all materials and consumables like protectors,testing adaptors,gaskets,ss fasteners,cooper plugs,paints, cooler cleaning chemicals are procure,supply and fitment in contractor scope. Eligibility Criteria for Participating Vendors: Vendors must have past experience in Cooler overhauling works on Defence vessels. The vendor shall submit documentary evidence of their past experience along with the technical bid. Failure to submit the required documents will result in rejection of the offer and disqualification of the vendor from the tender | |||||
| 0.0 | LUBE OIL COOLER,Test pressure shell side: 20 kg/cm2,both tube side:10 kg/cm2 | 2 | NOS | - | - |
| 0.9 | a) AIR COOLERS (1st and 2nd stage coolers), Test pressure shell side: 7 and 21kg/cm2,both tube side:5 kg/cm2
b) AIR COOLERS (3rd,4th and 5th stage coolers),Test pressure shell side: 80,250 and 670 kg/cm2,all tube side:5 kg/cm2
SETS(each set having 2 nos) | 2 | SETS | - | - |
| 0.0 | FRESH WATER COOLER(Plate type),Test pressure both side: 10 kg/cm2 | 3 | NOS | - | - |
| 0.9 | AIR COOLERS(Only pressure test to be carried out ) (3rd,4th and 5th stage coolers),Test pressure shell side: 80,250 and 670 kg/cm2,all tube side:5 kg/cm2 | 1 | NOS | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.12 MB
Tender_documents_TBID_145.pdf
Tender Documents • 0.37 MB
Tender_documents_TS.pdf
Tender Documents • 0.18 MB
BOQ_109168.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid