Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 LAccepted-AOC | L1 | Accepted-AOC Awarded to M/s M.S Electrical and Engineering Works (L-1) which found lowest | |
| 2 | L2₹8.2 L+₹641.98 (0.08%)Rejected-Finance V P O KARSOG TEHSIL KARSOG DISTT MANDI HP | KARSOG | MANDI | HIMACHAL PRADESH | L2 | Rejected-Finance L2 | |
| 3 | L3₹8.9 L+₹72,042.04 (8.84%)Rejected-Finance R O PURANA BAZAR KARSOG PO KARSOG TEH KARSOG DISTT MANDI H P 175011 | MANDI | HIMACHAL PRADESH | 175011 | L3 | Rejected-Finance L3 |
Tender Value
₹9.5 L
EMD Value
₹23,844
Closing Date
11 Mar 2025, 10:00 amClosed
Er. Chander Mani Sharma (XEN ED HPSEBL Karsog)
Office of Sr. Executive Engineer,ED Karsog
Tender for providing SOP for the improvement of LWSS Karsog and its adjoining area to make to the level of NAC by Prov. 63 KVA 22/0.4 KV 22 KV HT line for proposed 63 KVA sub- Station at Mokshdham ( Imla- Bimla ) in Teshil Karsog, District Mandi(HP)
2025_HPSEB_100766_1
184619/DB/2024-25-4816-25 Dated 24-02-2025
Open Tender
Supply and Erection
Item Wise
90 days
Karsog
Please refer tender document
10 documents required · 10 mandatory
₹590
₹23,844
21 Apr 2025
28 Feb 2025
11 Mar 2025
28 Feb 2025
11 Mar 2025
28 Feb 2025
Erection Charges
Add Erection Charges ( Erec of 63 kva dtr, LT bx, MCCBswitch, cable, service cable energy meter ) as per Cost Data 2023-24
Add extra manual carriage charges for an Average Lead 1.000 Km. from Road Head to Site of Work as per Cost Data 2022-23. AVERAGE LEAD -0.560 Kms
Supply Part of Sub Station
Prov. RCC Muff with C:C filling 2000 mm length
Prov. M.S.C.I. X-Arm (100x50x5 mm),Length 2800 mm X 4 Nos.
Prov. C.I. X-Arm (75X40x6 mm) length 2800 mm X 4 Nos. for supporting D O Fuse Unit & G O AB Switch
Prov. C.I. X-Arm (100X50x5 mm) length 460 mm X 2 Nos. for supporting Main Chanel of transformer.
Prov. M.S. A.I X Arm (50x50x6mm) Length 2800 mm x1 for L A's + 2 Nos. Distribution Box.
M.S. Angle Iron (50X50X6 mm), Length: 2800 X 4 Nos.
M.S. Angle Iron (35X35X6 mm), Length: 460 X 2 Nos.
GO AB Switch Unit Handle supporting ( Channel iron (75x40x6 mm), length
Prov. G.O. AB Switch Unit ( 22 kV, 400A, 25kV)
Prov. D.O.Fuse Unit
Prov. Surge Arrester, 18 kV Station Class (Porcilain Type) L.A.
Prov. Stay Set complete
Prov. Pipe Earthing
6 SWG GI wire for earting
Prov. LT Distribution Panel Box with MCCB (40A, 25kA, 4P, 1No.) and SFU (16A, 4 No., rewirable)
Prov. ACSR Cond. 6/1/3.35 mm (50 mm2)
Prov. Half Clamp with Nuts & Bolts (M.S. Flat 50X6 mm)
Prov. Full Clamp with Nuts & Bolts (M.S. Flat 50X6 mm)
Prov. M.S. Nuts and Bolts of various sizes (galvanised/ Coated) (Preferably 16 mm ɸ or more (With Flat & Spring Washers))
Prov. Aluminium. Thimble
Thimble
Prov. Danger Plate ( 203x200x1.6 mm )
Prov. LT Cable (3.5 Core) 120 mm2
a) Prov. Aluminium Paint.
b) Red Oxide
Prov. L.T Switched Capacitors 9 -KVAr for 63KVA (rate per KVAr)
Prov. Chain Link Kencing, Angle Iron, Gate etc. for transformer Fencing. ( As per HPSR )Also include Civil work (Earth work in excavation by mechanical means (hydraulic excavator)/ manual means in foundation trenches or drains ( not exceeding 105 m in width or 10sqm on plan), including dressing of sides and ramming of bottoms, lifts upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50M(All kinds of soil).Providing and lying in position cement, concrete of specified grade excluding the cost of centering and shuttering-All work uotp plinth level :1:4:8(1 Cement: 4sand :8 graded stone aggregate 40mm nominal size). Providing and lying in position cement, concrete of specified grade excluding the cost of centering, reinforcement, finishing and shuttering-All work uotp plinth level :1:1.5:3(1 Cement: 1.5sand :3 graded stone aggregate 20mm nominal size).Steel work welded in built upsections/ framed work, including cutting,hoisting,fixing in position and applying a priming coat of approval steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings,brackets,gates and similar works.Providing and fixing G.I chain link fabric fencing of required width in mesh size 50X50 mm including strengthening with 2mm dia wire or nuts,bolts and washers as required complete as per the direction of Engineere-in-charge. Made of G.I wire of dia 4mm.Providing and fixing ISI marked M.S pressed butt hinges bright finished with necessary screws etc. complete (100X58X1.90 mm).Also providing and fixing ISI marked oxisdised M.S. sliding door bolts with nuts and screws etc. complete:250X16 MM.
Prov.Dead End Clamp (Insulator Accessories )
Erection part of HT Line
Erection of Steel Tubular 9.00 Mtrs.Single Pole Str. a/w allied fitting
Erection of Steel Tubular 11 Mtrs. D/Pole Str. a/w allied fitting
Erection of H.T. Stay Set : Digging of pit, fixing of stay rod, nozzeling & tightening And filling of pit complete in all respect
Earthing :Digging of pit, Fixing of G.I. wire to the earthing system and filling of pit complete in all respect
Fixing of Jumper complete in all respect
Sagging of Conductor 1.00 Km. Single G.I. Wire/ AAAC/ACSR 20/25 mm2 : Laying, Stringing, Sagging & binding with insulator
Sagging of Conductor : 1Km Single ACSR/AAAC 6/1/3.35mm (50 mm2) : Laying, Stringing, Sagging & binding with insulator
Add extra manual carriage charges from Road Head to Site of Work for an Average lead 1.00 Km. as per C.D. 2023-24. AVERAGE LEAD - 0.500 km i.e ( M. Carriae = Line length x lead ) i.e M. Carriage = 0.650*0500 = 0.325Kms
Supply part of HT Line
Prov. RCC Muff with Concrete Filling 2000mm length.
Prov. ACSR Cond.6/1/3.35mm ( 50 mm2)
Prov. G.I.No. 6/ 8 SWG for Earth wire for S/T Pole ( double run through GI wire )
Prov. C.I.X-arm (100x50x5mm), Length(1800 mm ) for D. Pole / Dead pole Str.= 11*1.8 = 19.8 mtr
Prov. C.I. X-arm(100x50x5mm),Length: 2800 mm D.Pole Str. (13 nos * 2.8 = 36.4 mtr)
Prov. A.I.X-arm(100x50x6mm), Length: 3000 mm for Gaurding ( 3*10 = 30 mtr )
Prov. Belt Set (X-Bracing Set)M S A. Iron (50x50x6mm) Length: 1.5 mtr ( 18*1.5 = 27 mtrs )
Prov. Belt Set (X-Bracing Set)M S A. Iron(50x50x6mm) Length: 1.5 mtr ( 18*2.7 = 48.6 mtrs )
Prov. HT Stay Set Complete in all respect i/c Guy Assembly with Helically Fitting
HT Earthing Set complete
Prov. Full Clamp with nuts & bolts M.S. Flat 50x6 mm
Prov. Half Clamp with nuts & bolts M.S. Flat 50x6 mm
Prov. Earth/Eye Hook for Earth Wire
Prov. Danger Plate (250x200x1.6 mm)
Prov. Nuts & Bolts Of various sizes ( Gaivanised/ Coated) ( Preferably 16 mmɸ or more with flat and spring washers)
Prov. Barbed Wire
Prov. Alluminium Paint
Prov. Red Oxide
Prov D.O Fuse unit
Prov.Dead End Clamp (Insulator Accessories )
Erection Part of LT Line
Erection of Steel tubular pole 9mtr Long:Digging Of Pit,Drilling Of Holes In Pole X-Arm ,Erection Of Pole,Erec. Of X-Arm ,Shackle Insulator,Filling Of Pit And Ramming, complete in all respects
Fixing of Jumpers: Fixing of dead structure Jumpers Complete in all respects
Erection of LT Stay Set:-Digging Of Pit,Fixing of Stay Rod,Nozzeling & Tightening complete in all respects
Erection of Earthing Set:-Digging Of Pit,Fixing Of GI Wire To The Earthing System,Filling Of Pit complete in all respects
Sagging of Conductor . Single G.I. Wire/ AAAC/ACSR 20/25 mm2 : Laying, Stringing, Sagging & binding with insulator , complete in all respects
Sagging of Conductor : Single ACSR/AAAC 6/1/3.35mm (50 mm2) : Laying, Stringing, Sagging & binding with insulator complete in all respects
Add Extra manual carriage for average lead from road head to site of work. Average lead= 0.400 Km. ( M. Carriage = 0.4 * 0.08 = 0.032 km )
Supply Part of LT Line
Prov. R.C.C. Muff (2000 mm) with C. C. 1:2:4 for filling
Prov ACSR Cond. 6/1/3.35 mm (50 mm2)
Prov. G.I. Wire 8 SWG Earth wire
Prov. Shackle Insulator
Prov. D-Iron
Prov. L.T Stay Set
Prov. Stay Wire 7/3.15 mm (@6.0 kg per stay set)
Prov. Egg Insulator i/c Starp for Egg Insulator
Prov. Earth Knob
Prov. L.T. Earthing pipe
Prov. M.S. Nuts & Bolts off size@25kg for 3 Ph.
Prov. Alluminium Paint
Prov. PVC Spacer for 3 Ph.
Prov. C.I. X-Arm (75X40x5 mm) ( length 1.5 mtr + 0.2 mtr )
Red oxide of superior quality
Prov Full/Half Clamps [ 2 No for A.I + 1 No for Stay Set]
SATPAL (BID ID -498701)
Koyla Engineering Works (BID ID -500445)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .