Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.6 LAccepted-AOC HOUSE NO1201 NEAR HANUMAN MANDIR AT POST SHEL PIMPALGAON TAL KHED DIST PUNE PIN 410 501 | PALGHAR | MAHARASHTRA | 410501 | ₹14.6 L Quoted ₹15.7 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹18.9 L+₹3.2 L (20.3%)Rejected-Finance OFFICE 4 B JAY TENAMENT MADHUWAN PARK II BEHIND NIRMAL NAGAR RAMESHWAR NAGAR JAMNAGAR 361006 | JAMNAGAR | GUJARAT | 361006 | ₹18.9 L+₹3.2 L (20.3%) | L2 | Rejected-Finance Not lowest bidder |
| 3 | Rejected-Technical GEETA COTTAGE NO 03 HOUSE NO 11 OPP CIVIL AIR PORT BHUJ KUTCH 370001 GUJARAT | KACHCHH | GUJARAT | 370001 | - | - | Rejected-Technical NOT RECOMMENDED AS NOT ENLISTED IN CAT b(ii) |
| 4 | Rejected-Technical VILLAGE BHANADA TEH ABADASA DISTT KUTCH PIN 370645 GUJARAT | KACHCHH | GUJARAT | 370645 | - | - | Rejected-Technical NOT RECOMMENDED AS NOT ENLISTED IN CAT b(ii) |
| Sl No | Description | Qty | Unit | M/s. AMIT ASSOCIATES L1 | NAVIN K LAKHANI L2 |
|---|---|---|---|---|---|
| 1.00 | M & L for maintenance of VCB / RMU11 KV, 400/ 630 /1200 Amps including removal of VCB trolley, cleaning of all copper male and female contact, tightening of all connections, checking of all auxiliary contacts, control wiring, servicing of relays, etc. refixing the VCB trolley to its original position including proper setting of manual/motorize operation of VCB, checking/setting of tripping system, etc complete all as specified and directed by Engr-In-Charge.
Note: (i) Maintenance to be carried out the reps of Authorized person. (ii) After completion test certificate shall be furnished. (iii) Calibration of relay by injecting High voltage through CTS checking the over load system of VCB upto 90% rated load and artificial fault creation and setting of relay by 10 to 15% of rated load removing u/s overload and earh fault relay including connection with power pack. (iv) Opening out the trolly checking the operation of VCB mechanically and electrically through shunt trip coil including energizing of springs automatically including checking of TNC switch. | 8 | Each Job | 14,000 ₹1,12,000 Lowest | 16,000 ₹1,28,000 |
| 2.00 | M & L for taking down carefully Transformer / Isolation transformer/SVR of 100 KVA to 500 KVA and above capacity, any make, any type from pole / plinth/ base, disconnecting HT & LT side connections, earthing strip of transformer, supporting angles, cross arm, shifting / transporting transformer carefully from the site to the workshop opening the top cover of the transformer, bushing, draining of oil from the transformer, lifting the core complete taking out defective coils from the core, cleaning the tank and reassembling the transformer after carrying out the repairs/ replacement of worn out part, ovening the complete unit till to get desired megger value, transporting returning back to the site installing re-commissioning and testing of the transformer at its original place, connecting up HT & LT sides, earthings, supports / cross arms etc all as directed by Engr-In-Charge
Note: Spares, Rewinding of transformer,reinsulating & heating if required will be measured and paid separately under respective Sch'A' items | 2 | Each Job | 16,000 ₹32,000 Lowest | 16,400 ₹32,800 |
| 3.00 | S & F in repair Top cover gasket made up of 5 mm thick cork sheet. | 2 | Each Job | 800 ₹1,600 | 500 ₹1,000 Lowest |
| 4.00 | S & F in repair HT bushing, porcelain vitreous brown body suitable for 11 KV as per IS 3347 complete all as specified and directed by Engr-In-Charge. | 6 | Each | 600 ₹3,600 Lowest | 650 ₹3,900 |
| 5.00 | S & F in repair LT bushing, porcelain vitreous brown body 1100 V grade as per IS 3347 complete all as specified and directed by Engr-In-Charge. | 8 | Each | 580 ₹4,640 Lowest | 800 ₹6,400 |
| 6.00 | S & F in repair HT brass studs along with washers for one terminal 11 KV transformer complete all as specified and directed by Engr-In-Charge. | 6 | Each | 700 ₹4,200 Lowest | 1,050 ₹6,300 |
| 7.00 | S & F in repair LT brass studs along with washers for one terminal 1100 Volts grade transformers complete all as specified and directed by Engr-In-Charge. | 8 | Each | 650 ₹5,200 Lowest | 750 ₹6,000 |
| 8.00 | S & F in repair Breather assembly complete with silica GEL of make Omkar/Kamal complete all as specified and directed by Engr-In-Charge. | 4 | Each | 900 ₹3,600 Lowest | 1,250 ₹5,000 |
| 9.00 | S & F in repair Temp level indicator including its bolts, nuts, gasket etc complete all as specified and directed by Engr-In-Charge. | 4 | Each | 800 ₹3,200 | 650 ₹2,600 Lowest |
| 10.00 | Taking down old / burnt out HT/LT coils and rewinding the same by super enameled copper winding wire / strips of appropriate size of super quality (as per existing material & size of transformer coils) including, insulating, varnishing, heating, keeping coils in position, etc for transformer up to 500 KVA complete all as specified and directed by Engr-In-Charge. | 175 | Kilogram | 1,200 ₹2,10,000 Lowest | 1,620 ₹2,83,500 |
Tender Value
₹15.0 L
EMD Value
₹30,000
Closing Date
21 Aug 2025, 6:00 pmClosed
CWE (AF) BHUJ
CWE (AF) BHUJ KHAVDA ROAD BHUJ KACHCHH PIN 370001
REPAIR/REPLACEMENT OF INSULATORS/HT VCB/RMU PANELS/MAINTENANCE OF TRANSFORMER AND TWO POLE STRUCTURE AND EARTH PITS AND ALLIED WORKS AT AF STN MOTHALA UNDER GE (AF) NALIYA
2025_MES_720508_1
85295/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
NALIYA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) NALIYA
₹30,000
Yes
20 Sept 2025
15 Jul 2025
23 Aug 2025
15 Jul 2025
21 Aug 2025
29 Jul 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .