Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 LAccepted-AOC WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹22.3 L+₹2.4 L (11.9%)Rejected-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L2 | Rejected-AOC Become L2 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
9 Dec 2019, 6:00 pmClosed
GE SOUTH TEZPUR
GE SOUTH TEZPUR MISSION CHARALI
REPAIR/MAINT OF MECHANICAL LAUNDRY PLANT OIL FIRE INCINARETOR AND FIRE HYDRANT WITH ALLIED WORKS AT SAA UNDER GE (S) TEZPUR (3RD CALL)
2019_MES_279882_3
8433
Open Tender
Miscellaneous Services
Item Rate
180 days
GE SOUTH TEZPUR
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE SOUTH TEZPUR
₹40,000
Yes
6 Feb 2020
16 Nov 2019
11 Dec 2019
16 Nov 2019
9 Dec 2019
2 Dec 2019
Amount
Taking up cast iron water pipe line including all fittings laid in trenches heavy class with flanged / socket and spigot ends including all fittings viz, forged steel screwed fittings, flanged, bends, tees, reducers, elbow, clamps, hanger etc and kept in safe custody for reuse / disposal / taking credit the same for the following bore complete all as directed.
150 mm dia
100 mm dia
80 mm dia
Supply and fixing 150 mm nominal bore ERW heavy duty MS pipe of class C as per relavant IS and welding joints with MS coupler ring around the pipes complete as specified and directed.
Supply and fixing 100 mm nominal bore ERW heavy duty MS pipe of class C as per relavant IS and welding joints with MS coupler ring around the pipes complete as specified and directed.
Supply and fixing 80 mm nominal bore ERW heavy duty MS pipe of class C as per relavant IS and welding joints with MS coupler ring around the pipes complete as specified and directed.
Supply and fixing Mild steel bend (any type, radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc) tee pieces single branches 'Y' junction double branch, cross (all socket or socket and spigot) collars, caps and plugs for upto 150 mm bore of pipe complete all as directed.
The Annual Routine check up and preventive maintenance of Mechanical laundry eaquipment such as Washer extractor-02 nos, drying tumbler-02 nos, flat bed press-03 nos, manding machine-01 nos,copressor-01 nos and slucing machine-01 nos through authorise service agency by rep. of (FABCARE) company at 155 BH with the following condition. (a) Routin check up visites for procative and preventive maintenance gidance safty and equipments and also health checkup three times in each machine above given in a year from the work order (b) Guidance for overhauling of the equipments as per the scope, two times in year in each machine
Opening of Front loading type washer extractor 120 Kg capacity and dismantling unit after disconnection of electrical /stremline and taking out of the shaft, pully with others spares for carryout inspection of all bearing, bush, coupling, pully and overhauling the same, rectification the defects including repacement of unserviceable spare parts and assembling the same for smooth running after applying approved grade of grease , gasket nut bolt washer etc. (NOTE :- Spare required will be measured under separate item).
All as per item 7 above but for slucing machine of capacity 30 Kg.
All as per item 7 above but for Dry Tumbler front loading type of capacity 60 Kg.
All as per item 7 above but for flat work iron
Dismantling of Flat work double roll of roller (mending macine) after disconnection of electrical /stremline and taking out of the shaft, pully with others spares for carryout inspection of all bearing, bush, chest cleaning / polishing / refitting complete all as specified and directed. NOTE: Necessary labour /Truck jacks/Heavy hammer / Heavy tools to be arranged by contractor at site for chest loading/unloading from machine without any extra cost.
Supply only under mentioned spares for washer extractor machine / sluicing machine / drying tumbler / Flat bed press / Flat work Ironer including removing unserviceable old one MPD 7-20 A Flat work Ironer complete all as specified.
All as per item 12 above but Guide tape
All as per item 12 above but MPD 7-20 A flat work ironer
All as per item 12 above but Solenoid valve 5/2 way, TG sereies 220 V, AC 12/15 watt, pressure 2-10 Kg/Sqcm media - Air, 1/4" BSP connection.
All as per item 12 above but Steam hose pipe 1"x 650 mm
All as per item 12 above but Indicator light (R,G,B,C) RG
All as per item 12 above but DTC+TC for manding machine
All as per item 12 above but V belt main pully to motor fenner make for washer extractor 120 Kg capacity
All as per item 12 above but PCB computer controller complete set.
All as per item 12 above but Emergency push button.
All as per item 12 above but Pressure switch.
All as per item 12 above but Flexible Hose pipe for drain 4.5"x4'
All as per item 12 above but Mani fold (4 way)
All as per item 12 above but S.S plate for new display/ PCB computer controller for 120 kg washer extractor
All as per item 12 above but Door gasket heat proof with fixing solution.
All as per item 12 above but Butter fly valve pneumatic actuator fitted for 120 kg washer extractor
All as per item 12 above but Nipple 1/4x4 mm
All as per item 12 above but Elbow 3/4x4 mm
All as per item 12 above but Elbow 1/4x4 mm
All as per item 12 above but Elbow 1/8x4 mm
All as per item 12 above but PU pipe 4 mm with flare nut of length 1.5 mtr for Flat bed Press.
All as per item 12 above but Clip(s.s) Nut bolt for drain hose pipe
All as per item 12 above but S.S screw 1/4x 1.5"
All as per item 12 above but V belt main pully to motor fenner make for slucing machine 30 Kg capacity
All as per item 12 above but Steam hose pipe 3/4 x 300 mm nut nipple
All as per item 12 above but V belt main puley to motorsize-2650 HP
All as per item 12 above but Single solenoid valve 1/2" heavy duty
All as per item 12 above but MPD for flat bed press
All as per item 12 above but Push button ON/OFF
All as per item 12 above but Light(red)
All as per item 12 above but Silencer water flow control
All as per item 12 above but Silencer for solenoid valve
All as per item 12 above but FRL combination type ARC-2000, PT - 1/2" max.pressure range 0.5 - 8.5 Kg f/cm square temperature range 5 - 60 degree celcius with brass nut for connection.
All as per item 12 above but High tension stainless steel compressed spring 6" long 1" dia.
All as per item 12 above but Dossing pipe
All as per item 12 above but Ball bearing Braket size 513 including taking out old one.
All as per item 12 above but Ball bearings 1 inch with water seal cover, nut, bolt, jum nut, bearing socket.
All as per item 12 above but Ball bearing 1/2 inch with water seal cover nut, bolt, jum nut, bearing socket.
All as per item 12 above but Timmer (0-15/0-60), 120/250V
All as per item 12 above but Over load relay 4-6 Amp/6-10 A type ML with copper wire / lug / socket for connection.
All as per item 12 above but Power contactor type ML 1.5 with copper wire, lugs, socket for connection.
All as per item 12 above but Power contractor NHD 25 A 4 pole coil voltage 415 V 50 HZ.
Dismantling and taking down the existing electrical induction motor 3 Phase 415 volt of capacity 2 HP,935 RPM from base drive pully after disconnecting all electrical connection, striping out the motor complete for overhauling, servicing the motor winding by any hot compressed air and cleaning the winding with thinner and apply two coats of antimoisture heat resistance insulating varnish and drying up, cleaning the rotor and stator, replacement of defective parts such as bearing, terminal plate and reassembling the motor and refitting the same for smooth running of the machine. Note:spares parts for repair will be measured under separate item as supply only).
All as per item No. 54 above but capacity 30.00 HP.
Taking down motor 30 HP 415 volts, 1460 RPM after disconnecting all electrical connection nut, bolts from base plate and transportation to repair workshop and dismantling the motor stator, removing worn out copper winding, cleaning the stator and rewinding the same with super enamelled copper wire of existing size and specification and vernish the same with antimoisture heat resistance including varnishing and drying up slowly and including replacement of all types insulating tape, terminal plate, cable socket etc and reassembling the same, transporting to site for refixing in existing position for smooth running complete.
All as per item No. 56 above but capacity 2.0 HP capacity motor complete.
Dismantling/removing of ID / FD fan motor after disconnecting all electrical connection, nut /bolts etc from its base, stripping out the motor and blower for repair/overhauling including varnish, greasing after servicing the motor winding, cleaning the rotor stator and reassembling the same and refixing it for smooth running.
The Annual Routine check up and preventive maintenance of oil fired steam boiler 300 kg/h make-Thermax model (a) RXA-04,Sl no-1241,1242 or equivalent as approved by GE through authorise service agency of OEM or Origin (Tharmax) company at 155 BH with the following condition. (a) Routine check up visites for procative and preventive maintenance guidance safty and equipments and also health checkup four times in each boiler in a year from the work order (b) Guidance for overhauling of the equipments as per the scope, two times in year in each boiler. (c) Two Break Down visit
Maintenance and servicing of oil fired steam boiler 300 kg/h make-Thermax model (a) RXA-04,Sl no-1241,1242 with control pannel through authorise service agency of OEM or Origin (Tharmax) company including Dismentling the Steam Boiler for overhauling and taking out of all electrical connection and steam line, lifting up steam coil by chain pulley system with other spare parts for inspection and descaling of boiler coil inner tube by cleaning agent and decorbonise the same for proper passing of steam and overhauling of waterpump, fuel pump and replace the unserviceable spares parts/ defective/wornout parts with new spares such as sequence controller, photo resistor cell,valve sheat assembly, gland washer,nozzle, electrode cap, electrode, HT cable, loocking glass, RTD sensor, Temperature controller, Dial type thrmometer, steam pressure switch, water pressure switch, Hose metalic braded, Ignition Transformer, Packing Kylam, Packing Asbeestos, Fuel pump, water pump,pressure gauge, glove valve, gate valve, pipe, Motor,blower, MCCB, MCB, contactor, Maxclean chemical, Nut bolts, lubricating oil, and Cleaning of strainers with vaccum cleaner, cleaning of POL tank etc all as specified and directed. ( (Note spares required for above maint will be measured and paid separately under relevent items of Schedule):Location: 155 Base Hospital.
Disconnecting of unserviceable water pump for Thermax Boiler Model No RXA -04/10.54 and supply and fixing new water pump Triplex power sprayer, 950 RPM,3HP capacity, complete all as specified and as directed.
Disconnecting of unserviceable Fuel pump for Thermax Model NoRXA -04/10.54 and supply and fixing new fuel pump model-AJ6 AC, complete all as specified and as directed.
Disconnecting of unserviceable water pump motor for Thermax Boiler Model No RXA -04/10.54 and supply and fixing new water pump 3 phase induction motor 0.75 HP capacity, complete all as specified and as directed.
Disconnecting of unserviceable Fuel pump motor for Thermax Model NoRXA -04/10.54 and supply and fixing new fuel pump motor 3 phase induction motor of capacity 0.5 HP, 0.37 KW complete all as specified and as directed.
Supply, install, testing and commissioning water softening plant 1000 LPH for boiler feed water tank hardness less than 5 PPM with Raw water pump of capacity 1000 LPH, Softener of 0.25 mtr dia and 1.2 mtr height, pH dosing pump of capacity 80 Ltr, with necessary civil works including equipments foundation, foundation shed, grouting, V notch fixing, drain trenches, nutralisation pit etc complete all as specified and as directed. Note: Specification shall be as per relavant IS and make shall be approved by HQ CE Eastern Command or E-In C's Branch.
Supply, install, testing and commissioning of 10 zone with LCD display, microprocessor based local control panel suitable for operation on 24 volt DC, comprising of system for audio & visual alarm indication of fire, continous status indications of healthy fire/faulty zones/fire/fault test switches, zone isolation switch with indicators and also test switch for system test, sounder alarm and a switch to reset the whole system with audio viusal indicators complete all as specified and as directed.
Supply and Fix in replacement of ignition transformer input voltage 220//240 Volts,out put voltage 14500Volts ,CT Earthed, Cap 30 MA,frequency 50/60 Hz after taking out old one complete all as directed.
Supply and Fix in replacement of steam Pressure switch for steam boiler with necessary brass fittings/copper wire for connection as per existing complete all as directed.
Supply and Fix in replacement of water Pressure switch for steam boiler with necessary brass fittings/copper wire for connection as per existing complete all as directed.
Supply and Fix in replacement of water Pressure gauge 0-10/0-25/0-42(l) Pre Kg , 63 mm dia 1/4 " BSP bottom connection with adopter complete all as directed.
Supply and Fix in replacement of fuel filter with adopter complete all as directed.
Supply and Fix in replacement of Dial thermometer 0-400 deg celcius /0-600 deg celcius, 100 mm dial 1/2" BSP back connection complete all as directed.
Supply and Fix in replacement of Dial Thermometer 0-120 Deg.C. 63mm dia 1/2" BSP complete all as directed.
Supply and Fix in replacement of Burner nozzle 4.5 GPH 45 Deg Monarch for RXA 04 after taking out old one complete all as directed.
Supply and Fix in replacement of Sequence Contriller MA 810 complete.
Supply and Fix in replacement of Photo Resistor CEM 8205 complete all as specified.
Supply and Fix in replacement of Electrode Cap complete all as specified
Supply and Fix in replacement of Electrode 5" Long complete all as specified
Supply and Fix in replacement of HT Cable complete all as specified
Supply and Fix in replacement of Loocking Glass complete all as specified
Supply and Fix in replacement of RTD Sensor 5mtr Long complete all as specified
Supply and Fix in replacement of Digital Temp indicating controller 0-400Deg C TC-513 complete all as specified and as directed after taking out old one. complete all as specified
Supply and Fix in replacement of pressure gauge 0 to 40 KG G8 MM, 1/4' BSP bottom connection after taking old one.
Supply and Fix in replacement of Hose Metalic Braded 3/8" 40" long after taking old one.
Supply and Fix in replacement of Hose Metalic Braded 1" 1.5 Mtr long after taking old one.
Supply only chemical Maxclean-05. (Make as per E-in-C's branch or HQ CE Eastern Command)
Supply only chemical Maxtrat 3221 for softening plant. (Make as per E-in-C's branch or HQ CE Eastern Command)
Supply only strong acid cation exchange resin – sodium form for softening plant. (Make as per E-in-C's branch or HQ CE Eastern Command)
Supply and Fix in replacement of Packing Kylam complete all as specified.
Supply and Fix in replacement of Packing Asbestos complete all as specified.
Supply and Fix in replacement of solenoid coil 220 volt AC 50 Hz, 1.5 W including taking out old one complete all as specified.
Supply and Fix in replacement of Magnetic coil 220 volt AC after taking out old one complete all as specified.
Supply and Fix in replacement of oil seal (85-102-11) for Hydrolic Air Piston complete all as specified.
Supply and Fix in replacement of PT 100 Sensor complete all as specified
Supply and Fix in replacement of Main contactor 415 V 50 Hz 40 Amps complete all as specified and directed.
Supply and Fix in replacement of steam globe stop valve 25mm dia with hand wheel including necessary fitting suitable for steam line after taking out old one complete all as specified.
Supply and Fix in replacement of steam globe stop valve 20mm dia screw type with hand wheel including necessary fitting suitable for steam line after taking out old one
Supply and Fix in replacement of Globe type non return valve bronze 15/20 mm BSPT 15 nb/20nb bore with necessary fitting suitable for steam line after taking out old one.
Supply and Fix in replacement of Safety relief valve Bronze 25mm Angle type 150-250 PSI as per IBR including necessary fittings.
Supply and fixing the spares for Boiler machine RXA-04/Water Pump /Softener/ Fuel Pump including removing unserviceable old one Gland washer(TN 8) for water pump.
Supply and fixing the spares for Boiler machine RXA-04/Water Pump /Softener/ Fuel Pump including removing unserviceable old one Valve set assembly for water pump.
Supply and fixing the spares for Boiler machine RXA-04/Water Pump /Softener/ Fuel Pump including removing unserviceable old one Oil seal for fuel pump
Supply and fixing the spares for Boiler machine RXA-04/Water Pump /Softener/ Fuel Pump including removing unserviceable old one Oil ring for fuel pump/water pump.
Supply and fixing the spares for Boiler machine RXA-04/Water Pump /Softener/ Fuel Pump including removing unserviceable old one Packing retainer for pump/Boiler
Supply and fixing the spares for Boiler machine RXA-04/Water Pump /Softener/ Fuel Pump including removing unserviceable old one High pressure Metallic braded rubber hose 1/2" x 1 mtr long.
Material and Labur for cutting existing incinerator of size not less than 2.20m x 1.3m x 1.50m outer casing to remove complete lining of unserviceable fire brick work and supply and fix new heat resistant fire brick with fire resistance cement morter conforming to relevant IS complete and making good the cutting portion of outer casing by welding complete all as specified and as directed.
Supply and fixing isolation type smoke detector, duel chember, duel source with 2 radio active sources, having in built LED to indicate fire indication complete with base plate of 1.6mm thick sheet steel mounting box all as specified and as directed.
Supply and fixing glow type of spot / response indicator having two LED indicator in dust light enclosures with mounting base on ceiling / false ceiling / wall including necessary connection, testing and commissioning etc complete all as specified and as directed.
Taking out of jockey pump set from pump foundation after disconnection from motor /suction and delivery pipe and transportation to workshop dismantling the same and segregating of serviceable and unserviceable parts repairing and overhauling the pump set after replacement of defective parts and machine work and re-setting to the existing position connecting motor /all pipe line and commissioning and testing on full load to the entire satisfaction of Engr-in-Charge including two coats of synthetic enamel paint over a coat of primer including preparation of old painted surface all as speicified and directed.
Taking down old battery and supply and fixing DC starting system for diesel engine driven fire pump of capacity 12 volt including power bank lead acid battery of capacity 12 volts180 Ah all as directed.
Taking out of old 12.5 HP jockey induction motor of 3 phase 415 volts 50 Hz from the existing position after disconnecting all electrical cable earthing and pipe line/pump connection and transportation to workshop,dismantling the motor and rewinding the same with existing guage super enamelled copper wire of approved make varnishing the same and heating properly in heat chamber, re-assembling the motor after replacement of DE/NDE bearing terminal box all rusted nut and bolts and install the same to the existing position and apply 2 coats of synthetic enamel paints after successfully repairs and testing complete as specified and directed.
Excavation in trenches n.exc 1.5 mtr wide and n exc 1.5 mtr in depth and getting out in soft/loose for laying cables, etc. complete all as specified and as directed.
Returning, filling including spreading, levelling, watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and as directed.
Spreading and levelling in layers n exc. 25 cm thick and depositing where directed at a level not exceeding 1.5 mtr above ground level from starting point.
Disconnecting electric connection from main supply and taking out air compressor from inside the machanical laundry plant room and re-installed at out side of mechanical laundry plant as per manufacturer instruction and making necessary electrical connection and compressed air supply connection up to required laundry equipments complete all as directed.
SANJEEV ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .