Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.7 LAccepted-AOC HOSUE NO 202 NEW RAM VIHAR COLONY PINTO PARK MORAR GWALIOR 474005 MP | GWALIOR | MADHYA PRADESH | 474005 | ₹28.7 L Quoted ₹28.9 L | L1 | Accepted-AOC Being L1 and reasonable |
| 2 | L2₹32.9 LRejected-Finance | ₹32.9 L | L2 | Rejected-Finance Being other than L1 |
| 3 | L3₹33.6 LRejected-Finance | ₹33.6 L | L3 | Rejected-Finance Being other than L1 |
| 4 | L4₹37.8 LRejected-Finance PITHORAGARH PIN 900 336 C O 56 APO | 900336 | ₹37.8 L | L4 | Rejected-Finance Being other than L1 |
| 5 | L5₹38.4 LRejected-Finance P O BALASAUR ROAD KOTDWAR OPP PRINCE WEDDING POINT DISTT PAURI GARHWAL KOTDWAR UTTARAKHAND 246149 | KOTDWAR | PAURI GARHWAL | UTTARAKHAND | 246149 | ₹38.4 L | L5 | Rejected-Finance Being other than L1 |
| Sl No | Description | Qty | Unit | kumaon and hills strument engnering services L2 | M/s Dev Enterprises L6 | sun shine engineering L5 | KP ELECTRICAL AND AUTOMATION L1 | NV SERVICES L3 | Mahamaya Engineers Services L4 |
|---|---|---|---|---|---|---|---|---|---|
| .05DESCRIPTION OF ITEMS | |||||||||
| 1.00 | Supply ,laying jointing and testing of cable XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches or duct or passing through pipe or fixed to poles walls with suitable cable gland, lugs of cross sectional area 16 Sqmm 4 core complete all as specified and directed. | 1,020 | RM | 160 ₹1.6 L | 195 ₹2.0 L | 80 ₹81,600 | 150 ₹1.5 L | 177 ₹1.8 L | 222 ₹2.3 L |
| 2.00 | All as per ser item No 1 here in before but 25 sqmm 3.5 core | 275 | RM | 190 ₹52,250 | 242 ₹66,550 | 180 ₹49,500 | 190 ₹52,250 | 212 ₹58,300 | 272 ₹74,800 |
| 3.00 | All as per ser item No 1 here in before but 70 sqmm 3.5 core | 70 | RM | 300 ₹21,000 | 525 ₹36,750 | 531 ₹37,170 | 420 ₹29,400 | 440 ₹30,800 | 538 ₹37,660 |
| 4.00 | All as per ser item No 1 here in before but 95 sqmm 3.5 core | 90 | RM | 400 ₹36,000 | 643 ₹57,870 | 650 ₹58,500 | 550 ₹49,500 | 513 ₹46,170 | 668 ₹60,120 |
| 5.00 | All as per ser item No 1 here in before but 240 sqmm 3.5 core | 330 | RM | 1,200 ₹4.0 L | 1,535 ₹5.1 L | 1,300 ₹4.3 L | 1,200 ₹4.0 L | 1,128 ₹3.7 L | 1,522 ₹5.0 L |
| 6.00 | All as per ser item No 1 here in before but 300 sqmm 3.5 core | 300 | RM | 1,600 ₹4.8 L | 1,849 ₹5.5 L | 1,750 ₹5.3 L | 1,400 ₹4.2 L | 1,388 ₹4.2 L | 1,848 ₹5.5 L |
| 7.00 | All as per ser item No 1 here in before but 10 sqmm 2 core | 885 | RM | 140 ₹1.2 L | 130 ₹1.2 L | 120 ₹1.1 L | 80 ₹70,800 | 122 ₹1.1 L | 168 ₹1.5 L |
| 8.00 | Supply and laying in trenches/Floor or fixed to Pole/Wall GI pipe light grade with fitting for protection of cable complete all as specified and directed by the Engineer-in-Charge of following sizes:-
(a)80 mm bore | 30 | RM | 400 ₹12,000 | 580 ₹17,400 | 1,340 ₹40,200 | 300 ₹9,000 | 695 ₹20,850 | 700 ₹21,000 |
| 8.01 | (b)40 mm bore | 60 | RM | 300 ₹18,000 | 350 ₹21,000 | 800 ₹48,000 | 250 ₹15,000 | 375 ₹22,500 | 300 ₹18,000 |
Updated dates
Tender Value
₹40.5 L
EMD Value
₹81,100
Closing Date
17 Nov 2025, 6:00 pmClosed
GE Pithoragarh
GE Pithoragarh Post - Bharkatiya Pithoragarh - 262520
GE/PGH/68 of 2025-26
2025_MES_735244_1
8725/PGH/E8
Open Tender
Miscellaneous Services
240 days
Champawat
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE Pithoragarh
₹81,100
Yes
6 Jan 2026
15 Oct 2025
21 Nov 2025
15 Oct 2025
17 Nov 2025
3 Nov 2025
16 Oct 2025 - 23 Oct 2025
Amount
DESCRIPTION OF ITEMS
Supply ,laying jointing and testing of cable XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches or duct or passing through pipe or fixed to poles walls with suitable cable gland, lugs of cross sectional area 16 Sqmm 4 core complete all as specified and directed.
All as per ser item No 1 here in before but 25 sqmm 3.5 core
All as per ser item No 1 here in before but 70 sqmm 3.5 core
All as per ser item No 1 here in before but 95 sqmm 3.5 core
All as per ser item No 1 here in before but 240 sqmm 3.5 core
All as per ser item No 1 here in before but 300 sqmm 3.5 core
All as per ser item No 1 here in before but 10 sqmm 2 core
Supply and laying in trenches/Floor or fixed to Pole/Wall GI pipe light grade with fitting for protection of cable complete all as specified and directed by the Engineer-in-Charge of following sizes:- (a)80 mm bore
(b)40 mm bore
Excavation in trenches, not exceeding 1.5 m wide and n. exc 1.5 m in depth for laying of cable for in any type of soil and getting out all as specified and directed.
All as per Item No: 9 above but depth exceeding beyond 1.5mtr and not exc 3 metre all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n. exc 25 cm apart for soft/loose soil all as specified and directed.
Removing excavated material to a distance n.exc 50 mtr and depositing where directed at level n.exc 1.5 mtr above the starting point all as specified and as directed.
Material and labour for well burnt bricks,Sub class 'B' bricks, best quality locally available laid flat, dry in trenches for cable protection complete all as specified and as directed.
M & L for dry Sand cushioning in trenches for protection of cable including watering and consolidation all as specified and directed. Note: Punned thickness shall be considerd for measurment purpose.
Material and labour for PCC 1:3:6 Type C-2 (Using 40 mm grade aggregate as in foundation of pole, stay and filling and mass concrete) including providing necessary form work complete all as specified and as directed.
Material and labour for PCC 1:2:4 type B1 set in cement mortar 1:6 using 20 mm grade stone aggregate as in copping of electric pole at site including providing necessary form work complete all as specified and as directed.
M&L for cutting the road/hard standing to a size not exceeding 75cm in depth and 45 cm in width for protection of XLPE cable including making good so as to match existing finishing with PCC 1:2:4 type B1 using 20mm graded stone aggregate for 100mm thick on top incld fair finishing complete all as specified and as directed.
Supply, fixing and erection of steel tubular swaged pole 09 m long, type 410 SP-31, weight not less than 154 kgs, pole should be in one piece only and smooth finishing, ISI marked conforming to IS:2713-1980, complete with all accessories, such as cast iron base plate, finial taper plug, bolts, nuts, screws, washers and drilling of holes for continious GI earth wire as specified including applying two coats of aluminium paint over one coat of red oxide zinc chrome primer and embedded portion shall be painted with two coats of black japan paint after preparation of surface( synthetic enamel paint in red and white strips upto 1.5 mtr height from coping ) complete all as specified and directed. Note:-PCC,Earth work, MS work,cross arms and clamps shall be measured and paid separately.
Supply, fixing and connecting Bus bar box of min size 300mm x 260mm x 165mm manufactured out of 3mm thick MS sheet with hinged door, comprising of TPN aluminium bus bar of capacity 32 Amp 415 Volt fixed on porcelain insulators, making holes on strips for connecting cables and fixed to street light pole with and including 2 nos MS clamp of size 25mmx5mm incl nut ,bolt, washer and incl two coat of synthetic enamel paint over a coat of red oxide primer and including MCB SP 10A, B curve 10kA breaking capacity and cable entry and exit through bottom with double compression copper stainless steel cable glands and gaskets complete all as specified and as directed by the Engineer in charge.
Material and Labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR PT-I including necessary excavation and earth work PCC (1:3:6) type C-1 with 50 mm thick pre cast RCC ( 1:2:4) type B-1 cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar) including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, Contd.....
with funnel and 20 mm bore galvanized iron watering pipe (medium grade) wire mesh, GI lugs, complete in all respect, GI earth wire protected by 15 mm bore (Light grade) galvanized iron pipe and other end connected with main switch board or earthing test point as directed including proper lugs, including disposal of soil to a distance not exceeding 50 mtr and necessary testing on completion complete all as specified and as directed by the Engineer in charge .Note:1. Earthing Installation shall be done in the presence of Engineer in charge.2. Earth resistance shall not exceed 1ohm.
M&L for of PVC insulated weather prof flat three round core copper cable of size 2.5 Sqmm single core laid from junction box to street light fitting through(internally) LT pole all as specified. .
Dismantling ACSR conductor of any size from LT pole and setting a side the serviceable quantity for reuse and removing the unserviceable quantity from site complete all as specified and as directed.
Dismantling and taking down mild steel cross arms, bracings, supports, channels,angles,clamps etc from pole structure segregating serviceable portion and keeping in safe custody for reuse at site and removing unserviceable portion from site complete all as specified and as directed.
Dismantling insulators of any size /type and setting a side the serviceable quantity for reuse and removing the unserviceable quantity from site.
Design,Engineering,Manufacture,Transportation to site,Supply,Install,Testing & Commissioning of factory manufactured outdoor type LT Feeder Pillar Box cum busbar chamber cubical type,suitable size as per oem design, compartmentalized design made from CRCA sheet steel of 3.15mm thick for frame work/load bearing members ,1.6mm thick for doors and covers,3 mm thick for gland plates, floor mounted, IP 56,separate compartments for each switchgears with hinged doors including interlocking, totally enclosed weather,dust ,vermin proof made of angle iron frame 50mm X50mmX6mm with cable entry and exit through bottom with double compression copper stainless steel cable glands and gaskets and front & back side operated double door with proper hinge , all doors and covers shall be fully gasket double lip type to prevent any ingress of dust and rain,cleaning and finishing complete with 7 tank process for powder coating in approved shade,door hinges concealed type,front and back access shall be available for all switchgears for maintenance and replacement, Contd.......
cable termination box and locking arrangement suitable for 3 phase 415 volts 50Hz AC supply with high conduvtivity Aluminium bus bar(0.8A/sqmm) 4 nos of equal size 400 Amp rating,415 volts,3 phase 4 wire supported on FRP,SMC or DMC insulators,CTI as per IS ,a continuous earth bus of size 50mmx6mm GI will be given to the entire length of the panel at bottom ,cable glands with independent plates at bottom for each outgoing and incoming cables and painting panel board complete with two coats of powder coated paint over a coat of red oxide primer with spray painting on internal and external surfaces and shall be complete incld internal wiring using with suitable size of copper conductor cables and aluminium strips for incoming and outgoing connections of all switches/MCB's,/MCCB',Bus bar cable alley .Bus bar shall be insulated with colour code/sleeves /tapes ,R/Y/B for phases & black for neutral, earth busbar shall in green colour, Contd......
Bus bar shall be of continuous rating with fault level of 50KA (1 sec) as per IEC,clearances between phases and live parts shall be as per IS/IEC, danger notice plate shall be fitted on each door back & front,Two earth terminal shall be provided on each side of LT panel board,Panel colour Siemens grey, including bottom base channel of MS section not less than 150mm x 75mmx5.4mm thick (ISMC 150)fabrication shall be done in transportable sections,LT Panel shall be fixed on base frame made of ISMC 150(150mmx75mmx5.4mm),base frame shall be 600mm above ground , base frame four legs to be grouted with PCC 1:3:6 type C2 20mm aggregare (30cm width x 45 cm depth) in post hole, base frame and legs shall be painted with synthetic enamel paint double coat over a coat of red oxide primer and suitable name plate 3mm GI thick name plate with giving detailed designation eg feeder no, equipment tag no, description, rating etc as directed of switch/panel board shall be affixed on top of switch complete Panel to be approved by contractor before installation/fabrication also drawing ofall as specified and directed.LT panel board shall be complete in all respects with and incld the following accessories:- Contd......
(a) MCCB 4 pole ,current rating 250 Amp ,TM based having overload,short circuit release+ spreader,breaking capacity 36KA,Ics=100%Icu,Adjustable overload and adjustable short circuit, at 415V,50Hz( with Rotary operating mechanism for MCCB + Aux Contact)---01No(Incoming) (b) Multifunctional meter ---01No (c) CT'S 400/5 01 Set (d) Indicator lamp RYB :01 Set
Design,Engineering ,manufacture,transportation to site,Supply,install,testing & commissioning of factory LT Panel made outdoor cubical type of suitable size, compartmentalized design made from CRCA sheet steel of 3.15mm thick for frame work/load bearing members ,1.6mm thick for doors and covers,3 mm thick for gland plates, floor mounted, IP 56,separate compartments for each switchgears with hinged doors including interlocking, totally enclosed weather,dust ,vermin proof made of angle iron frame 50mm X50mmX6mm with cable entry and exit through bottom with double compression copper stainless steel cable glands and gaskets and front & back side operated double door with proper hinge , all doors and covers shall be fully gasket double lip type to prevent any ingress of dust and rain,cleaning and finishing complete with 7 tank process for powder coating in approved shade,door hinges concealed type,front and back access shall be available for all switchgears for maintenance and replacement, Contd......
cable termination box and locking arrangement suitable for 3 phase 415 volts 50Hz AC supply with high conduvtivity Aluminium bus bar(0.8A/sqmm) 4 nos of equal size 600 Amp rating,415 volts,3 phase 4 wire supported on FRP,SMC or DMC insulators,CTI as per IS ,a continuous earth bus of size 50mmx6mm GI will be given to the entire length of the panel at bottom ,cable glands with independent plates at bottom for each outgoing and incoming cables and painting panel board complete with two coats of powder coated paint over a coat of red oxide primer with spray painting on internal and external surfaces and shall be complete incld internal wiring using with suitable size of copper conductor cables and aluminium strips for incoming and outgoing connections of all switches/MCB's,/MCCB',Bus bar cable alley .Bus bar shall be insulated with colour code/sleeves /tapes ,R/Y/B for phases & black for neutral, earth busbar shall in green colour, Bus bar shall be of continuous rating with fault level of 50KA (1 sec) as per IEC,clearances between phases and live parts shall be as per IS/IEC, Contd......
danger notice plate shall be fitted on each door back & front,Two earth terminal shall be provided on each side of LT panel board,Panel colour Siemens grey, including bottom base channel of MS section not less than 150mm x 75mmx5.4mm thick (ISMC 150)fabrication shall be done in transportable sections,LT Panel shall be fixed on base frame made of ISMC 150(150mmx75mmx5.4mm),base frame shall be 600mm above ground , base frame four legs to be grouted with PCC 1:3:6 type C2 20mm aggregare (30cm width x 45 cm depth) in post hole, base frame and legs shall be painted with synthetic enamel paint double coat over a coat of red oxide primer,suitable name plate 3mm GI thick name plate with giving detailed designation eg feeder no, equipment tag no, description, rating etc as directed of switch/panel board shall be affixed on top of switch complete complete all as specified and directed.LT panel board shall be complete in all respects with and incld the following accessories:- Contd......
INCOMING:- a) MCCB 4 pole ,current rating 400Amp ,TM based having overload,short circuit release+ spreader,breaking capacity 36KA,Ics=100%Icu,Adjustable overload and adjustable short circuit, at 415V,50Hz( with Rotary operating mechanism for MCCB + Aux Contact)---01No b)Tape wound CTs ratio:400/5A,Class>1,VA>15----03 Nos c)CT shorting Terrminals-------03 No d)LED phase indication lamp(R,Y,B)>230V AC Supply---03 Nos e)LED indication lamp(ON,OFF,TRIP)>230V AC Supply-----03 Nos f) 6A SP MCB 10KA, C series-----03 Nos g) Neutral link h)Multifunction meter --- 01 No Contd......
OUTGOINGS:- a) MCCB 4 pole ,current rating 320Amp , TM based having overload,short circuit release , breaking capacity 36KA, Ics=100%Icu,Adjustable overload and adjustable short circuit at 415V,50Hz ( with Rotary operating mechanism for MCCB + Aux Contact)------01No b) MCCB 4 pole ,current rating 100Amp , TM based having overload,short circuit release , breaking capacity 25KA, Ics=100%Icu,Adjustable overload and adjustable short circuit at 415V,50Hz ( with Rotary operating mechanism for MCCB + Aux Contact)------01No c) MCCB 4 pole ,current rating 63Amp , TM based having overload,short circuit release , breaking capacity 25KA, Ics=100%Icu,Adjustable overload and adjustable short circuit at 415V,50Hz ( with Rotary operating mechanism for MCCB + Aux Contact)------02No
Design,Engineering ,manufacture,transportation to site,Supply,install,testing & commissioning of factory LT Panel made outdoor cubical type of suitable size, compartmentalized design made from CRCA sheet steel of 3.15mm thick for frame work/load bearing members ,1.6mm thick for doors and covers,3 mm thick for gland plates, floor mounted IP 56,separate compartments for each switchgears with hinged doors including interlocking, totally enclosed weather,dust ,vermin proof made of angle iron frame 50mm X50mmX6mm with cable entry and exit through bottom with double compression copper stainless steel cable glands and gaskets and front & back side operated double door with proper hinge , all doors and covers shall be fully gasket double lip type to prevent any ingress of dust and rain,cleaning and finishing complete with 7 tank process for powder coating in approved shade, Contd......
door hinges concealed type,front and back access shall be available for all switchgears for maintenance and replacement,cable termination box and locking arrangement suitable for 3 phase 415 volts 50Hz AC supply with high conduvtivity Aluminium bus bar(0.8A/sqmm) 4 nos of equal size 200 Amp rating,415 volts,3 phase 4 wire supported on FRP,SMC or DMC insulators,CTI as per IS , sheets ,a continuous earth bus of size 50mmx6mm GI will be given to the entire length of the panel at bottom ,cable glands with independent plates at bottom for each outgoing and incoming cables and painting panel board complete with two coats of powder coated paint over a coat of red oxide primer with spray painting on internal and external surfaces and shall be complete incld internal wiring using with suitable size of copper conductor cables and aluminium strips for incoming and outgoing connections of all switches/MCB's,/MCCB',Bus bar cable alley .Bus bar shall be insulated with colour code/sleeves /tapes , Contd......
R/Y/B for phases & black for neutral, earth busbar shall in green colour, Bus bar shall be of continuous rating with fault level of 50KA (1 sec) as per IEC,clearances between phases and live parts shall be as per IS/IEC, danger notice plate shall be fitted on each door back & front,Two earth terminal shall be p[rovided on each side of LT panel board,Panel colour Siemens grey, including bottom base channel of MS section not less than 150mm x 75mmx5.4mm thick (ISMC 150)fabrication shall be done in transportable sections,LT Panel shall be fixed on base frame made of ISMC 150(150mmx75mmx5.4mm),base frame shall be 600mm above ground , base frame four legs to be grouted with PCC 1:3:6 type C2 20mm aggregare (30cm width x 45 cm depth) in post hole, base frame and legs shall be painted with synthetic enamel paint double coat over a coat of red oxide primer, and suitable name plate 3mm GI thick name plate with giving detailed designation eg feeder no, equipment tag no, description, rating etc as directed of switch/panel board shall be affixed on top of switch complete complete all as specified and directed.LT panel board shall be complete in all respects with and incld the following accessories:- Contd......
INCOMING:- a) MCCB 4 pole ,current rating 160Amp ,TM based having overload,short circuit release+ spreader,breaking capacity 36KA,Ics=100%Icu,Adjustable overload and adjustable short circuit, at 415V,50Hz( with Rotary operating mechanism for MCCB + Aux Contact)---01No b)Tape wound CTs ratio:200/5A,Class>1,VA>15----03 Nos c)CT shorting Terrminals-------03 No d)LED phase indication lamp(R,Y,B)>230V AC Supply---03 Nos e)LED indication lamp(ON,OFF,TRIP)>230V AC Supply-----03 Nos f)6A SP MCB 10KA, C series-----03 Nos g) Neutral link h)Multifunction meter --- 01 No Contd.......
OUTGOINGS:- a) MCCB 4 pole ,current rating 63 Amp , TM based having overload,short circuit release , breaking capacity 25KA, Ics=100%Icu,Adjustable overload and adjustable short circuit at 415V,50Hz ( with Rotary operating mechanism for MCCB + Aux Contact)------04No
Design,Engineering ,manufacture,transportation to site,Supply,install,testing & commissioning of factory LT Panel made outdoor cubical type of suitable size, compartmentalized design made from CRCA sheet steel of 3.15mm thick for frame work/load bearing members ,1.6mm thick for doors and covers,3 mm thick for gland plates, floor mounted IP 56,separate compartments for each switchgears with hinged doors including interlocking, totally enclosed weather,dust ,vermin proof made of angle iron frame 50mm X50mmX6mm with cable entry and exit through bottom with double compression copper stainless steel cable glands and gaskets and front & back side operated double door with proper hinge , all doors and covers shall be fully gasket double lip type to prevent any ingress of dust and rain,cleaning and finishing complete with 7 tank process for powder coating in approved shade,door hinges concealed type,front and back access shall be available for all switchgears for maintenance and replacement, Contd......
cable termination box and locking arrangement suitable for 3 phase 415 volts 50Hz AC supply with high conduvtivity Aluminium bus bar(0.8A/sqmm) 4 nos of equal size 500 Amp rating,415 volts,3 phase 4 wire supported on FRP,SMC or DMC insulators,CTI as per IS , sheets ,a continuous earth bus of size 50mmx6mm GI will be given to the entire length of the panel at bottom ,cable glands with independent plates at bottom for each outgoing and incoming cables and painting panel board complete with two coats of powder coated paint over a coat of red oxide primer with spray painting on internal and external surfaces and shall be complete incld internal wiring using with suitable size of copper conductor cables and aluminium strips for incoming and outgoing connections of all switches/MCB's,/MCCB',Bus bar cable alley .Bus bar shall be insulated with colour code/sleeves /tapes ,R/Y/B for phases & black for neutral, earth busbar shall in green colour, Bus bar shall be of continuous rating with fault level of 50KA (1 sec) as per IEC,clearances between phases and live parts shall be as per IS/IEC, Contd......
danger notice plate shall be fitted on each door back & front,Two earth terminal shall be p[rovided on each side of LT panel board,Panel colour Siemens grey, including bottom base channel of MS section not less than 150mm x 75mmx5.4mm thick (ISMC 150)fabrication shall be done in transportable sections,LT Panel shall be fixed on base frame made of ISMC 150(150mmx75mmx5.4mm),base frame shall be 600mm above ground , base frame four legs to be grouted with PCC 1:3:6 type C2 20mm aggregare (30cm width x 45 cm depth) in post hole, base frame and legs shall be painted with synthetic enamel paint double coat over a coat of red oxide primer, and suitable name plate 3mm GI thick name plate with giving detailed designation eg feeder no, equipment tag no, description, rating etc as directed of switch/panel board shall be affixed on top of switch complete all as specified and directed.LT panel board shall be complete in all respects with and incld the following accessories:- Contd.......
INCOMING:- a) MCCB 4 pole ,current rating 320Amp ,TM based having overload,short circuit release+ spreader,breaking capacity 36KA,Ics=100%Icu,Adjustable overload and adjustable short circuit, at 415V,50Hz( with Rotary operating mechanism for MCCB + Aux Contact)---01No b)Tape wound CTs ratio:400/5A,Class>1,VA>15----03 Nos c)CT shorting Terrminals-------03 No d)LED phase indication lamp(R,Y,B)>230V AC Supply---03 Nos e)LED indication lamp(ON,OFF,TRIP)>230V AC Supply-----03 Nos f)6A SP MCB 10KA, C series-----03 Nos g) Neutral link h)Multifunction meter --- 01 No Contd.........
OUTGOINGS:- a) MCCB 4 pole ,current rating 250 Amp , TM based having overload,short circuit release , breaking capacity 36 KA, Ics=100%Icu,Adjustable overload and adjustable short circuit at 415V,50Hz ( with Rotary operating mechanism for MCCB + Aux Contact)------01No b) MCCB 4 pole ,current rating 100 Amp , TM based having overload,short circuit release , breaking capacity 25 KA, Ics=100%Icu,Adjustable overload and adjustable short circuit at 415V,50Hz ( with Rotary operating mechanism for MCCB + Aux Contact)------03No
Design,Engineering ,manufacture,transportation to site,Supply,install,testing & commissioning of factory LT Panel made outdoor cubical type of suitable size, compartmentalized design made from CRCA sheet steel of 3.15mm thick for frame work/load bearing members ,1.6mm thick for doors and covers,3 mm thick for gland plates, floor mounted IP 56,separate compartments for each switchgears with hinged doors including interlocking, totally enclosed weather,dust ,vermin proof made of angle iron frame 50mm X50mmX6mm with cable entry and exit through bottom with double compression copper stainless steel cable glands and gaskets and front & back side operated double door with proper hinge , all doors and covers shall be fully gasket double lip type to prevent any ingress of dust and rain,cleaning and finishing complete with 7 tank process for powder coating in approved shade,door hinges concealed type,front and back access shall be available for all switchgears for maintenance and replacement,cable termination box and locking arrangement suitable for 3 phase 415 volts 50Hz AC supply Contd........
with high conduvtivity Aluminium bus bar(0.8A/sqmm) 4 nos of equal size 400 Amp rating,415 volts,3 phase 4 wire supported on FRP,SMC or DMC insulators,CTI as per IS , sheets ,a continuous earth bus of size 50mmx6mm GI will be given to the entire length of the panel at bottom ,cable glands with independent plates at bottom for each outgoing and incoming cables and painting panel board complete with two coats of powder coated paint over a coat of red oxide primer with spray painting on internal and external surfaces and shall be complete incld internal wiring using with suitable size of copper conductor cables and aluminium strips for incoming and outgoing connections of all switches/MCB's,/MCCB',Bus bar cable alley .Bus bar shall be insulated with colour code/sleeves /tapes ,R/Y/B for phases & black for neutral, earth busbar shall in green colour, Bus bar shall be of continuous rating with fault level of 50KA (1 sec) as per IEC,clearances between phases and live parts shall be as per IS/IEC, Contd.......
danger notice plate shall be fitted on each door back & front,Two earth terminal shall be p[rovided on each side of LT panel board,Panel colour Siemens grey, including bottom base channel of MS section not less than 150mm x 75mmx5.4mm thick (ISMC 150)fabrication shall be done in transportable sections,LT Panel shall be fixed on base frame made of ISMC 150(150mmx75mmx5.4mm),base frame shall be 600mm above ground , base frame four legs to be grouted with PCC 1:3:6 type C2 20mm aggregare (30cm width x 45 cm depth) in post hole, base frame and legs shall be painted with synthetic enamel paint double coat over a coat of red oxide primer, and suitable name plate 3mm GI thick name plate with giving detailed designation eg feeder no, equipment tag no, description, rating etc as directed of switch/panel board shall be affixed on top of switch complete all as specified and directed.LT panel board shall be complete in all respects with and incld the following accessories:- Contd......
INCOMING:- a) MCCB 4 pole ,current rating 250 Amp ,TM based having overload,short circuit release+ spreader,breaking capacity 36KA,Ics=100%Icu,Adjustable overload and adjustable short circuit, at 415V,50Hz( with Rotary operating mechanism for MCCB + Aux Contact)---01No b)Tape wound CTs ratio:250/5A,Class>1,VA>15----03 Nos c)CT shorting Terrminals-------03 No d)LED phase indication lamp(R,Y,B)>230V AC Supply---03 Nos e)LED indication lamp(ON,OFF,TRIP)>230V AC Supply-----03 Nos f)6A SP MCB 10KA, C series-----03 Nos g) Neutral link h)Multifunction meter --- 01 No
OUTGOINGS:- b) MCCB 4 pole ,current rating 100 Amp , TM based having overload,short circuit release , breaking capacity 25 KA, Ics=100%Icu,Adjustable overload and adjustable short circuit at 415V,50Hz ( with Rotary operating mechanism for MCCB + Aux Contact)------02No b) MCCB 4 pole ,current rating 63 Amp , TM based having overload,short circuit release , breaking capacity 25 KA, Ics=100%Icu,Adjustable overload and adjustable short circuit at 415V,50Hz ( with Rotary operating mechanism for MCCB + Aux Contact)------03No
Design,Engineering ,manufacture,transportation to site,Supply,install,testing & commissioning of factory LT Panel made outdoor cubical type of suitable size, compartmentalized design made from CRCA sheet steel of 3.15mm thick for frame work/load bearing members ,1.6mm thick for doors and covers,3 mm thick for gland plates, floor mounted, IP 56,separate compartments for each switchgears with hinged doors including interlocking, totally enclosed weather,dust ,vermin proof made of angle iron frame 50mm X50mmX6mm with cable entry and exit through bottom with double compression copper stainless steel cable glands and gaskets and front & back side operated double door with proper hinge , all doors and covers shall be fully gasket double lip type to prevent any ingress of dust and rain,cleaning and finishing complete with 7 tank process for powder coating in approved shade,door hinges concealed type,front and back access shall be available for all switchgears for maintenance and replacement, Contd.......
cable termination box and locking arrangement suitable for 3 phase 415 volts 50Hz AC supply with high conduvtivity Aluminium bus bar(0.8A/sqmm) 4 nos of equal size 200 Amp rating,415 volts,3 phase 4 wire supported on FRP,SMC or DMC insulators,CTI as per IS ,a continuous earth bus of size 50mmx6mm GI will be given to the entire length of the panel at bottom ,cable glands with independent plates at bottom for each outgoing and incoming cables and painting panel board complete with two coats of powder coated paint over a coat of red oxide primer with spray painting on internal and external surfaces and shall be complete incld internal wiring using with suitable size of copper conductor cables and aluminium strips for incoming and outgoing connections of all switches/MCB's,/MCCB',Bus bar cable alley .Bus bar shall be insulated with colour code/sleeves /tapes ,R/Y/B for phases & black for neutral, earth busbar shall in green colour, Contd........
Bus bar shall be of continuous rating with fault level of 50KA (1 sec) as per IEC,clearances between phases and live parts shall be as per IS/IEC, danger notice plate shall be fitted on each door back & front,Two earth terminal shall be provided on each side of LT panel board,Panel colour Siemens grey, including bottom base channel of MS section not less than 150mm x 75mmx5.4mm thick (ISMC 150)fabrication shall be done in transportable sections,LT Panel shall be fixed on base frame made of ISMC 150(150mmx75mmx5.4mm),base frame shall be 600mm above ground , base frame four legs to be grouted with PCC 1:3:6 type C2 20mm aggregare (30cm width x 45 cm depth) in post hole, base frame and legs shall be painted with synthetic enamel paint double coat over a coat of red oxide primer, and suitable name plate 3mm GI thick name plate with giving detailed designation eg feeder no, equipment tag no, description, rating etc as directed of switch/panel board shall be affixed on top of switch complete all as specified and directed.LT panel board shall be complete in all respects with and incld the following accessories:- Contd.....
INCOMING:- a) MCCB 4 pole ,current rating 160Amp ,TM based having overload,short circuit release+ spreader,breaking capacity 36KA,Ics=100%Icu,Adjustable overload and adjustable short circuit, at 415V,50Hz( with Rotary operating mechanism for MCCB + Aux Contact)---01No b)Tape wound CTs ratio:200/5A,Class>1,VA>15----03 Nos c)CT shorting Terrminals-------03 No d)LED phase indication lamp(R,Y,B)>230V AC Supply---03 Nos e)LED indication lamp(ON,OFF,TRIP)>230V AC Supply-----03 Nos f)6A SP MCB 10KA, C series-----03 Nos g) Neutral link h)Multifunction meter --- 01 No
OUTGOINGS:- a) MCCB 4 pole ,current rating 63Amp , TM based having overload,short circuit release , breaking capacity 25KA, Ics=100%Icu,Adjustable overload and adjustable short circuit at 415V,50Hz ( with Rotary operating mechanism for MCCB + Aux Contact)------03No b) MCCB 4 pole ,current rating 40Amp , TM based having overload,short circuit release , breaking capacity 25KA, Ics=100%Icu,Adjustable overload and adjustable short circuit at 415V,50Hz ( with Rotary operating mechanism for MCCB + Aux Contact)------01No
Design,Engineering ,manufacture,transportation to site,Supply,install,testing & commissioning of factory LT Panel made outdoor cubical type of suitable size, compartmentalized design made from CRCA sheet steel of 3.15mm thick for frame work/load bearing members ,1.6mm thick for doors and covers,3 mm thick for gland plates, floor mounted, IP 56,separate compartments for each switchgears with hinged doors including interlocking, totally enclosed weather,dust ,vermin proof made of angle iron frame 50mm X50mmX6mm with cable entry and exit through bottom with double compression copper stainless steel cable glands and gaskets and front & back side operated double door with proper hinge , all doors and covers shall be fully gasket double lip type to prevent any ingress of dust and rain,cleaning and finishing complete with 7 tank process for powder coating in approved shade,door hinges concealed type,front and back access shall be available for all switchgears for maintenance and replacement, Contd.....
cable termination box and locking arrangement suitable for 3 phase 415 volts 50Hz AC supply with high conduvtivity Aluminium bus bar(0.8A/sqmm) 4 nos of equal size 250 Amp rating,415 volts,3 phase 4 wire supported on FRP,SMC or DMC insulators,CTI as per IS ,a continuous earth bus of size 50mmx6mm GI will be given to the entire length of the panel at bottom ,cable glands with independent plates at bottom for each outgoing and incoming cables and painting panel board complete with two coats of powder coated paint over a coat of red oxide primer with spray painting on internal and external surfaces and shall be complete incld internal wiring using with suitable size of copper conductor cables and aluminium strips for incoming and outgoing connections of all switches/MCB's,/MCCB',Bus bar cable alley .Bus bar shall be insulated with colour code/sleeves /tapes ,R/Y/B for phases & black for neutral, earth busbar shall in green colour, Bus bar shall be of continuous rating with fault level of 50KA (1 sec) as per IEC,clearances between phases and live parts shall be as per IS/IEC, Contd......
danger notice plate shall be fitted on each door back & front,Two earth terminal shall be provided on each side of LT panel board,Panel colour Siemens grey, including bottom base channel of MS section not less than 150mm x 75mmx5.4mm thick (ISMC 150)fabrication shall be done in transportable sections,LT Panel shall be fixed on base frame made of ISMC 150(150mmx75mmx5.4mm),base frame shall be 600mm above ground , base frame four legs to be grouted with PCC 1:3:6 type C2 20mm aggregare (30cm width x 45 cm depth) in post hole, base frame and legs shall be painted with synthetic enamel paint double coat over a coat of red oxide primer, and suitable name plate 3mm GI thick name plate with giving detailed designation eg feeder no, equipment tag no, description, rating etc as directed of switch/panel board shall be affixed on top of switch complete all as specified and directed.LT panel board shall be complete in all respects with and incld the following accessories:- Contd........
INCOMING:- a) MCCB 4 pole ,current rating 160Amp ,TM based having overload,short circuit release+ spreader,breaking capacity 36KA,Ics=100%Icu,Adjustable overload and adjustable short circuit, at 415V,50Hz( with Rotary operating mechanism for MCCB + Aux Contact)---01No b)Tape wound CTs ratio:250/5A,Class>1,VA>15----03 Nos c)CT shorting Terrminals-------03 No d)LED phase indication lamp(R,Y,B)>230V AC Supply---03 Nos e)LED indication lamp(ON,OFF,TRIP)>230V AC Supply-----03 Nos f)6A SP MCB 10KA, C series-----03 Nos g) Neutral link h)Multifunction meter --- 01 No
OUTGOINGS:- a) MCCB 4 pole ,current rating 100 Amp , TM based having overload,short circuit release , breaking capacity 25KA, Ics=100%Icu,Adjustable overload and adjustable short circuit at 415V,50Hz ( with Rotary operating mechanism for MCCB + Aux Contact)------01No b) MCCB 4 pole ,current rating 63Amp , TM based having overload,short circuit release , breaking capacity 25KA, Ics=100%Icu,Adjustable overload and adjustable short circuit at 415V,50Hz ( with Rotary operating mechanism for MCCB + Aux Contact)------02No
Design,Engineering ,manufacture,transportation to site,Supply,install,testing & commissioning of factory LT Panel made outdoor cubical type of suitable size, compartmentalized design made from CRCA sheet steel of 3.15mm thick for frame work/load bearing members ,1.6mm thick for doors and covers,3 mm thick for gland plates, floor mounted, IP 56,separate compartments for each switchgears with hinged doors including interlocking, totally enclosed weather,dust ,vermin proof made of angle iron frame 50mm X50mmX6mm with cable entry and exit through bottom with double compression copper stainless steel cable glands and gaskets and front & back side operated double door with proper hinge , all doors and covers shall be fully gasket double lip type to prevent any ingress of dust and rain,cleaning and finishing complete with 7 tank process for powder coating in approved shade,door hinges concealed type,front and back access shall be available for all switchgears for maintenance and replacement, Contd......
cable termination box and locking arrangement suitable for 3 phase 415 volts 50Hz AC supply with high conduvtivity Aluminium bus bar(0.8A/sqmm) 4 nos of equal size 200Amp rating,415 volts,3 phase 4 wire supported on FRP,SMC or DMC insulators,CTI as per IS ,a continuous earth bus of size 50mmx6mm GI will be given to the entire length of the panel at bottom ,cable glands with independent plates at bottom for each outgoing and incoming cables and painting panel board complete with two coats of powder coated paint over a coat of red oxide primer with spray painting on internal and external surfaces and shall be complete incld internal wiring using with suitable size of copper conductor cables and aluminium strips for incoming and outgoing connections of all switches/MCB's,/MCCB',Bus bar cable alley .Bus bar shall be insulated with colour code/sleeves /tapes ,R/Y/B for phases & black for neutral, earth busbar shall in green colour, Bus bar shall be of continuous rating with fault level of 50KA (1 sec) as per IEC,clearances between phases and live parts shall be as per IS/IEC, Contd........
danger notice plate shall be fitted on each door back & front,Two earth terminal shall be provided on each side of LT panel board,Panel colour Siemens grey, including bottom base channel of MS section not less than 150mm x 75mmx5.4mm thick (ISMC 150)fabrication shall be done in transportable sections,LT Panel shall be fixed on base frame made of ISMC 150(150mmx75mmx5.4mm),base frame shall be 600mm above ground , base frame four legs to be grouted with PCC 1:3:6 type C2 20mm aggregare (30cm width x 45 cm depth) in post hole, base frame and legs shall be painted with synthetic enamel paint double coat over a coat of red oxide primer, and suitable name plate 3mm GI thick name plate with giving detailed designation eg feeder no, equipment tag no, description, rating etc as directed of switch/panel board shall be affixed on top of switch complete all as specified and directed.LT panel board shall be complete in all respects with and incld the following accessories:- Contd.......
INCOMING:- a) MCCB 4 pole ,current rating 160 Amp ,TM based having overload,short circuit release+ spreader,breaking capacity 36KA,Ics=100%Icu,Adjustable overload and adjustable short circuit, at 415V,50Hz( with Rotary operating mechanism for MCCB + Aux Contact)---01No b)Tape wound CTs ratio:200/5A,Class>1,VA>15----03 Nos c)CT shorting Terrminals-------03 No d)LED phase indication lamp(R,Y,B)>230V AC Supply---03 Nos e)LED indication lamp(ON,OFF,TRIP)>230V AC Supply-----03 Nos f)6A SP MCB 10KA, C series-----03 Nos g) Neutral link h)Multifunction meter --- 01 No
OUTGOINGS:- a) MCCB 4 pole ,current rating 100 Amp , TM based having overload,short circuit release , breaking capacity 25KA, Ics=100%Icu,Adjustable overload and adjustable short circuit at 415V,50Hz ( with Rotary operating mechanism for MCCB + Aux Contact)------01No b) MCCB 4 pole ,current rating 63 Amp , TM based having overload,short circuit release , breaking capacity 25KA, Ics=100%Icu,Adjustable overload and adjustable short circuit at 415V,50Hz ( with Rotary operating mechanism for MCCB + Aux Contact)------01No c) MCCB 4 pole ,current rating 40Amp , TM based having overload,short circuit release , breaking capacity 25KA, Ics=100%Icu,Adjustable overload and adjustable short circuit at 415V,50Hz ( with Rotary operating mechanism for MCCB + Aux Contact)------01No
Design,Engineering ,manufacture,transportation to site,Supply,install,testing & commissioning of factory LT Panel made outdoor cubical type of suitable size, compartmentalized design made from CRCA sheet steel of 3.15mm thick for frame work/load bearing members ,1.6mm thick for doors and covers,3 mm thick for gland plates, floor mounted, IP 56,separate compartments for each switchgears with hinged doors including interlocking, totally enclosed weather,dust ,vermin proof made of angle iron frame 50mm X50mmX6mm with cable entry and exit through bottom with double compression copper stainless steel cable glands and gaskets and front & back side operated double door with proper hinge , all doors and covers shall be fully gasket double lip type to prevent any ingress of dust and rain,cleaning and finishing complete with 7 tank process for powder coating in approved shade,door hinges concealed type,front and back access shall be available for all switchgears for maintenance and replacement, Contd.......
cable termination box and locking arrangement suitable for 3 phase 415 volts 50Hz AC supply with high conduvtivity Aluminium bus bar(0.8A/sqmm) 4 nos of equal size 200Amp rating,415 volts,3 phase 4 wire supported on FRP,SMC or DMC insulators,CTI as per IS ,a continuous earth bus of size 50mmx6mm GI will be given to the entire length of the panel at bottom ,cable glands with independent plates at bottom for each outgoing and incoming cables and painting panel board complete with two coats of powder coated paint over a coat of red oxide primer with spray painting on internal and external surfaces and shall be complete incld internal wiring using with suitable size of copper conductor cables and aluminium strips for incoming and outgoing connections of all switches/MCB's,/MCCB',Bus bar cable alley .Bus bar shall be insulated with colour code/sleeves /tapes ,R/Y/B for phases & black for neutral, earth busbar shall in green colour, Bus bar shall be of continuous rating with fault level of 50KA (1 sec) as per IEC,clearances between phases and live parts shall be as per IS/IEC, Contd........
danger notice plate shall be fitted on each door back & front,Two earth terminal shall be provided on each side of LT panel board,Panel colour Siemens grey, including bottom base channel of MS section not less than 150mm x 75mmx5.4mm thick (ISMC 150)fabrication shall be done in transportable sections,LT Panel shall be fixed on base frame made of ISMC 150(150mmx75mmx5.4mm),base frame shall be 600mm above ground , base frame four legs to be grouted with PCC 1:3:6 type C2 20mm aggregare (30cm width x 45 cm depth) in post hole, base frame and legs shall be painted with synthetic enamel paint double coat over a coat of red oxide primer, and suitable name plate 3mm GI thick name plate with giving detailed designation eg feeder no, equipment tag no, description, rating etc as directed of switch/panel board shall be affixed on top of switch complete all as specified and directed.LT panel board shall be complete in all respects with and incld the following accessories:- Contd........
INCOMING:- a) MCCB 4 pole ,current rating 160 Amp ,TM based having overload,short circuit release+ spreader,breaking capacity 36KA,Ics=100%Icu,Adjustable overload and adjustable short circuit, at 415V,50Hz( with Rotary operating mechanism for MCCB + Aux Contact)---01No b)Tape wound CTs ratio:200/5A,Class>1,VA>15----03 Nos c)CT shorting Terrminals-------03 No d)LED phase indication lamp(R,Y,B)>230V AC Supply---03 Nos e)LED indication lamp(ON,OFF,TRIP)>230V AC Supply-----03 Nos f)6A SP MCB 10KA, C series-----03 Nos g) Neutral link h)Multifunction meter --- 01 No
OUTGOINGS:- a) MCCB 4 pole ,current rating 100 Amp , TM based having overload,short circuit release , breaking capacity 25KA, Ics=100%Icu,Adjustable overload and adjustable short circuit at 415V,50Hz ( with Rotary operating mechanism for MCCB + Aux Contact)------01No b) MCCB 4 pole ,current rating 63 Amp , TM based having overload,short circuit release , breaking capacity 25KA, Ics=100%Icu,Adjustable overload and adjustable short circuit at 415V,50Hz ( with Rotary operating mechanism for MCCB + Aux Contact)------02No c) MCCB 4 pole ,current rating 40Amp , TM based having overload,short circuit release , breaking capacity 25KA, Ics=100%Icu,Adjustable overload and adjustable short circuit at 415V,50Hz ( with Rotary operating mechanism for MCCB + Aux Contact)------01No
Design,Engineering ,manufacture,transportation to site,Supply,install,testing & commissioning of factory LT Panel made outdoor cubical type of suitable size, compartmentalized design made from CRCA sheet steel of 3.15mm thick for frame work/load bearing members ,1.6mm thick for doors and covers,3 mm thick for gland plates, floor mounted, IP 56,separate compartments for each switchgears with hinged doors including interlocking, totally enclosed weather,dust ,vermin proof made of angle iron frame 50mm X50mmX6mm with cable entry and exit through bottom with double compression copper stainless steel cable glands and gaskets and front & back side operated double door with proper hinge , all doors and covers shall be fully gasket double lip type to prevent any ingress of dust and rain,cleaning and finishing complete with 7 tank process for powder coating in approved shade,door hinges concealed type,front and back access shall be available for all switchgears for maintenance and replacement, Contd........
cable termination box and locking arrangement suitable for 3 phase 415 volts 50Hz AC supply with high conduvtivity Aluminium bus bar(0.8A/sqmm) 4 nos of equal size 200Amp rating,415 volts,3 phase 4 wire supported on FRP,SMC or DMC insulators,CTI as per IS ,a continuous earth bus of size 50mmx6mm GI will be given to the entire length of the panel at bottom ,cable glands with independent plates at bottom for each outgoing and incoming cables and painting panel board complete with two coats of powder coated paint over a coat of red oxide primer with spray painting on internal and external surfaces and shall be complete incld internal wiring using with suitable size of copper conductor cables and aluminium strips for incoming and outgoing connections of all switches/MCB's,/MCCB',Bus bar cable alley .Bus bar shall be insulated with colour code/sleeves /tapes ,R/Y/B for phases & black for neutral, earth busbar shall in green colour, Bus bar shall be of continuous rating with fault level of 50KA (1 sec) as per IEC,clearances between phases and live parts shall be as per IS/IEC, Contd........
danger notice plate shall be fitted on each door back & front,Two earth terminal shall be provided on each side of LT panel board,Panel colour Siemens grey, including bottom base channel of MS section not less than 150mm x 75mmx5.4mm thick (ISMC 150)fabrication shall be done in transportable sections,LT Panel shall be fixed on base frame made of ISMC 150(150mmx75mmx5.4mm),base frame shall be 600mm above ground , base frame four legs to be grouted with PCC 1:3:6 type C2 20mm aggregare (30cm width x 45 cm depth) in post hole, base frame and legs shall be painted with synthetic enamel paint double coat over a coat of red oxide primer, and suitable name plate 3mm GI thick name plate with giving detailed designation eg feeder no, equipment tag no, description, rating etc as directed of switch/panel board shall be affixed on top of switch complete all as specified and directed.LT panel board shall be complete in all respects with and incld the following accessories:- Contd.......
INCOMING:- a) MCCB 4 pole ,current rating 160 Amp ,TM based having overload,short circuit release+ spreader,breaking capacity 36KA,Ics=100%Icu,Adjustable overload and adjustable short circuit, at 415V,50Hz( with Rotary operating mechanism for MCCB + Aux Contact)---01No b) Tape wound CTs ratio:200/5A,Class>1,VA>15----03 Nos c) CT shorting Terrminals-------03 No d) LED phase indication lamp(R,Y,B)>230V AC Supply---03 Nos e) LED indication lamp(ON,OFF,TRIP)>230V AC Supply-----03 Nos f) 6A SP MCB 10KA, C series-----03 Nos g) Neutral link h)Multifunction meter --- 01 No
OUTGOINGS:- a) MCCB 4 pole ,current rating 100 Amp , TM based having overload,short circuit release , breaking capacity 25KA, Ics=100%Icu,Adjustable overload and adjustable short circuit at 415V,50Hz ( with Rotary operating mechanism for MCCB + Aux Contact)------01No b) MCCB 4 pole ,current rating 63 Amp , TM based having overload,short circuit release , breaking capacity 25KA, Ics=100%Icu,Adjustable overload and adjustable short circuit at 415V,50Hz ( with Rotary operating mechanism for MCCB + Aux Contact)------02No
Note : Tenderers may note that amount of credit Rs 19,042.50 will be deducted from the total amount arrived, at the time of Acceptance of contract.
kumaon and hills strument engnering services (BID ID -3476554)
NV SERVICES (BID ID -3471168)
Mahamaya Engineers Services (BID ID -3471034)
sun shine engineering (BID ID -3476350)
M/s Dev Enterprises (BID ID -3470659)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
BOQ_823315.xls
BOQ • 0.35 MB
tender_docs.pdf
Tender Documents • 2.33 MB
Download all tender documents and submit your bid