Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance D NO 9 947 66 DOCTORS COLONY SHIVAJI PLEM VISAKHAPATNAM 530017 | VISAKHAPATANAM | ANDHRA PRADESH | 530017 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
Closing Date
20 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Azmat Arshi
GE(P)Navy Kalinga
Urgent Repairs/Maintenance to Diesel Generator SET OF Capacity 7.5 KVA at STP at Naval Station Bheemunipatnam Visakhapatnam
2022_MES_524017_1
GE(P)/N/K/JOB/03 of 2022-23
Limited
Miscellaneous Services
Item Rate
30 days
GE(P) Navy Kalinga
Urgent Repairs/Maintenance to Diesel Generator SET OF Capacity 7.5 KVA at STP at Naval Station Bheemunipatnam Visakhapatnam
1 document required · 1 mandatory
₹0
Exempted
21 May 2022
13 May 2022
21 May 2022
14 May 2022
20 May 2022
14 May 2022
30 days
Amount
M&L for repair of 7.5KVA Diesel Engine by dismantling the Sub-assemblies such as fuel pump, fuel injection, wood ward Governor, turbo-charger, radiator, oil cooler, engine heads, rocker arms, self starter, dynamo-engine wiring, terminal contacts and safety controls etc. including replacement of spare parts as required and re-assembling the sub-assemblies after carrying out necessary repairs including testing and commissioning complete all as directed by Engineer-in-charge for the following capacity. Notes: 1. Supply only Spare Parts required shall be measured and paid separately under relevant items of Schedule 'A' 2. Repairs and calibration of Sub-assemblies shall be measured and paid separately under relevant items of Schedule 'A'
M&L for Repair & Calibration of wood ward Governor as per calibration procedure and norms for the following capacity of DG Sets:
M&L for Repair & Calibration of turbo super charger as per calibration procedure and norms as per manufacturer's guide lines including replacement of Turbo supply & discharge hoses and clamps and de-scaling of Turbo charger complete all as specified and directed for the following capacity of DG Sets:
M&L for Repair & Calibration of Fuel Pump & Injectors as per calibration procedure and norms as per manufacturer's guide lines including replacement of unserviceable 'O' rings, Plungers and cups etc.
M&L in repairs dismantiling rusted/defective acoustic enclosure doors hinges and supply and fix new doors hinges of any size including cutting welding brazing complete all as specified and directed ny Engr-in-charge.
M&L for De-scaling of radiator by dismantling the upper & lower tank and cleaning the core pipes with cleaning chemicals, components and arrest the leaking core by brazing/ dummy with lead including cleaning of upper and lower tanks and replacing the upper and lower gaskets and required nuts, bolts, refixing the same including testing and painting complete all as specified and directed for the 7.5KVA DG SET all as specified and directed.
M&L for Maintenance and servicing of alternator of any Make of any capacity by opening the end cover, cleaning the dust and rust formed over the terminals, cleaning with CTC liquid up to the satisfaction and checking of diodes , excitation winding, isolating transformer and AVR panel and applying Dr. beck paint for insulation improvement over the strips/ winding and drying till getting sasfactory insulation resistance complete, and refixing the covers and testing complete all as specified and directed for the following capacity of alternators:
Supply only the following Spare Parts as required during repair of engine Head-reconditioning of capacity 7.5 KVA all as specified and directed.
a)Valve guide Nos-1
b) exhaust valve Nos-1
c) intake valve Nos-1
d) valve spring Nos-1
e) valve lock Nos-1
f) valve set Nos-1
g) gasket kit Nos-1
(h) Lube oil filter Nos-1
(i) fuel filter Nos-1
Supply, replacing,testing & calibrating and commissitoning of hour run meter cum tacho meter,dial type,Analog type,range 0 - 1500 RPM,reselution 50 RPM,control spring cable including inner and outer complete all as directed
Supply, install, testing and comissioning of tubular batteries 12 V, 180 AH including copper terminal lugs complete and replace disconnecting old unserviceable 12V,180AH batteries with copper terminal lugs complete. Make: Exide/Tata green/Amron
Material and labour for maintenance to 7.5 KVA Gen Set for 'B' check after 06 months or 250 hrs running, whichever is earlier as per the recommendations of manufacturer including renewing of necessary filters, Engine oil etc, complete all as per manufacturers instructional manual and all as directed by Engg-in-charge. Note : Engine oil will not be suplied under Sch 'B' for carrying out 'B' check.The quoted rate deemed to be included for the same.
Material and labour for replacement of air cleaner filter to 15 KVAGen Set matching with existing and as per the recommendations of manufacturer all as directed by Engg-in-charge.
Supply only for top up engine oil 15W40 or as per manufacturers recommendations. Make: Servo/ Volvoline/HPCL
supply and fixing in repair Self Starter motor for 7.5 KVA KIRLOSKAR make matching with existing and as per the recommendations of manufacturer .
Dismantaling / Removal of Accoustic doors by cutting and removing out the corodded parts of canopy of DG set 7.5KVA including Supply of materials and labour replacing CRCA sheet 2mm thick and necessary welding brazing grindig etc fixing unserviceble hinges suitable for 7.5kVA DG set with proper aligment and given excellent surface finish by applying enamelled paint with spray gun and necessary stickering for Capacity and make all as specified and directed by Enge-in-charge.
M&L in repairs dismantling unserviceable auto mains failure unit and supply and fix new wirirng harness via 2 Nos connectors on the rear of C7.5D5 AMF unit for CUMMINS 7.5KVA DG set with complete connections for auto on process including replacement of unserviceable part testing and commissioning complete all as specified and directed by Enge-in-charge.
SRIVALLI ENGINEERS
F AND M TECHNOLOGIES
stage.html
html • 0.02 MB
finance_585545.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .