Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 LAccepted-AOC | L1 | Accepted-AOC L1 being accepted | |
| 2 | L2₹4.6 L+₹36,406 (8.62%)Rejected-Finance | L2 | Rejected-Finance L1 been accepted |
Tender Value
Refer Docs
EMD Value
₹9,000
Closing Date
25 Nov 2020, 6:00 pmClosed
Shri HR Sinha AEE
AF Station Suryalanka Bapatla Guntur 522101
REPAIRS MAINT OF DIFFERENT TYPE CAPACITY OF CENTRIFUGAL MONOBLOCK SUBMERSIBLE MOTOR, PUMP, STARTER AND ALLIED ITEMS AT AF STATION SURYALANKA
2020_MES_380369_2
AGE (I) / SL/ TOKEN / 37 OF 2020-21
Open Tender
Civil Works - Others
Item Rate
180 days
AF Station Suryalanka
Please refer Tender documents.
8 documents required · 8 mandatory
₹300
AGE (I) Suryalanka
₹9,000
3 Dec 2020
4 Nov 2020
26 Nov 2020
4 Nov 2020
25 Nov 2020
11 Nov 2020
4 Nov 2020 - 7 Nov 2020
Amount
Disconnecting electric/water connections and removing centrifugal motor from base plate of pumpset and transporting motor to workshop and back after repair, servicing etc and refixing in it's original position, testing and commissioning complete all as specified and as directed for the following capacity :-
20 HP 3 pahse
10 to 12.5 HP 3 phase
5 to 7.5 HP 3 phase
Disconnecting electric/water connections and removing centrifugal/monoblock pumpset and transporting to workshop and back after repair, servicing etc and refixing in it's original position, testing and commissioning complete all as specified and as directed for the following capacity :-
20 HP 3 pahse
10 to 12.5 HP 3 phase
5 to 7.5 HP 3 phase
0.5 to 3 HP 1 phase (Note for Srl item No-1.01, 1.02, 1.03, 2.01, 2.02, 2.03 & 2.04 : Repairs/replacement of parts/winding etc shall be measure and paid separately).
M&L for opening of pump assembly, removing worn out bushes, lockkeys, case rings, air release valve, gaskets and replacing with new items of same capacity/type including necessary machine works at site as required complete all as specified and as directed for the following capacities :-
20 HP 3 pahse
10 to 12.5 HP 3 phase
M & L for rewinding of induction motor by means of cutting and removing existing burnt out winding completely, cleaning and repair of slots and rewinding with new copper wire of existing gauge and size/turns, varnishing with class B insulation, assembling the motor complete, testing at workshop all as specified and as directed for the following capacity :-
20 HP 3 pahse
10 to 12.5 HP 3 phase
5 to 7.5 HP 3 phase
2 HP 1 phase
1 HP 1 phase
0.5 HP 1 phase
S & F in repairs all ball/roller bearings in centrifugal/ monoblock motor and pump of following capacity after taking out broken/wear & tear unserviceable bearing for the following :-
20 HP 3 pahse
10 to 12.5 HP 3 phase
5 to 7.5 HP 3 phase
2 HP to 3 HP 1 phase
1 to 0.5 HP 1 phase
M & L for fixing Rubber/Looza coupling as per sample after taking out old unserviceable one for the following capacity centrifugal pumps including all connected work such as displacement of motor, refixing in same position, motor-pump synchronisation and testing complete all as specified and as directed :-
20 HP 3 pahse
10 to 12.5 HP 3 phase
7.5 HP 3 phase
S & F in repairs stainless steel shaft for centrifugal pump of following capacity after taking out broken/wear & tear/ unserviceable shaft as per the sample & existing type & size for the following :-
20 HP 3 pahse
12.5 HP 3 phase
7.5 HP 3 phase
S & F in repairs impeller in centrifugal pump of following capacity after taking out broken/wear & tear/ unserviceable impeller as per the sample & existing size for the following :-
20 HP 3 pahse
10 to 12.5 HP 3 phase
5 to 7.5 HP 3 phase
3 HP to 1 HP 1 phase
1 to 0.5 HP 1 phase
M & L for preparation of old painted surfaces of centrifugal pump set of following capacity and applying two coats of synthetic enamel paint over a coat of red oxide primer complete and writing of MES/SM No complete all as specified and as directed for the following capacity :-
20 HP 3 pahse
12.5 HP 3 phase
10 HP 3 phase
7.5 HP 3 phase
5 HP 3 phase
S & F in repair floot valve after taking out old unserviceable foot valve from open well/UG sump conforming to relevant IS-4038 PN 0.2 for the following sizes complete all as specified and as directed :-
CI 100mm dia
PVC 100mm dia
PVC 80mm dia
S & F in replacement of ultraflon gland packing of size 6mm to 10mm for centrifugal pumps for different capacity ranging 7.5 to 20 HP complete all as specified and as directed.
S & F in replacement of CI sluice valve, PN 1.6, ISI marked, flanged ends and suitable holes drilled with brass spindle and check nut including rubber gasket 3mm thick nuts, bolts & washers and other necessary machine works as required at site including taking down/removing the unserviceable sluice valve complete all as specified for the following sizes :-
CI 150mm dia
CI 100mm dia
CI 80mm dia
M & L for repairs to 80/100/150mm CI sluice valves refacing, regrinding, repacking stuffing box of sluice valve spindle after cleaning and including re-assembling with 3mm thick gaskets, nuts, bolts, washers and other necessary machine works as required at site complete all as specified and as directed.
S & F in replacement of Fuel pipe of length not exceeding 1 feet alongwith brass end terminals suitable for 12 HP diesel engine complete all as specified and as directed.
S & F in replacement of onload change over switch-Disconnector (conforms to IEC 60947-3, IS/IEC 60947-3, 125A, 415V, 50Hz, 4 pole including removing the old unserviceable change over switch after disconnecting from panel busbar complete all as specified and as directed. (Make : L & T CO21250OOOO or any other equivalent)
Masonry valve chamber 750 x 750 x 75mm for 80mm dia galte valve including excavation and earth work in any type of soil and 100mm thick PCC 1:4:8, type D-2 foundation, brick work in CM 1:6, 15mm thick plastering on internal surface in CM 1:4, PCC 1:3:6, type C-1 as in coping and using 50 x 50 x 6mm angle iron frame & 6mm thick MS plate cover complete with locking arrangement, painting on steel and iron surface with two coats of synthetic enamel paint over a coat of zinc chrome primer complete all as specified and shown on drawing.
Sub Total of Schedule 'A'
Schedule of Credit (Minus) Rs. 5,795.00 B/F from Ser page No. 25. NOTE: Bidder shall insert credit amount as rate Rs. 5,795.00 in Green field under Col-6. If bidder does not insert the amount the same will be deducted from total amount of Schedule 'A' and accordingly total amount of tender will be considered in deciding the lowest tender.
Sub Total of Schedule of Credit
K VENUGOPALA SWAMY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .