Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.8 LAccepted-AOC | L1 | Accepted-AOC Please see summary | |
| 2 | L2₹7.5 L+₹57,610 (8.34%)Rejected-AOC 2ND FLOOR KALOOR BUSSTAND COMPLEX BUS STAND COMPLEX KALOOR BUSSTAND COMPLEX ERNAKULAM KERALA 682017 | ERNAKULAM | KERALA | 682017 | L2 | Rejected-AOC Please see summary |
Tender Value
₹6.7 L
EMD Value
₹16,781
Closing Date
9 Sept 2024, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DGM (Projects)
Dgm ( proj) Travancore titanium products LTD Kochuveli Trivandrum
Installation, testing and commissioning of PMCC and laying of connected cable for Cooling Tower at TTPL.
2024_TTPL_685627_1
PROJ/Cooling tower /PMCC/KV-19 /24-25
Open Tender
Miscellaneous Services
Item Wise
40 days
Travancore Titanium Products Ltd, Trivandrum- 21
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,584
Yes
₹16,781
Yes
9 Dec 2024
14 Aug 2024
10 Sept 2024
14 Aug 2024
9 Sept 2024
14 Aug 2024
14 Aug 2024 - 9 Sept 2024
Cable laying
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Cable tray Instalation
laying and Installation of 300mm size of ladder type FRP cable trays
supply and fabrication of MS items for cable tray errection
Supply, fabricating and installing MS items<br>Supply, fabricating and installing MS Angles 50x50x5mm on floor/ ceiling/ wall including necessary civil work such as grouting, finishing etc. and painting with two coats of primer and two coats of synthetic enamel paint as required for cable tray supports
cable termination
Supplying and making end termination with brass double compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3.5C x 240Sq.mm (AL)
Supplying and making end termination with brass double compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3C x 120Sq.mm (AL)
Supplying and making end termination with brass double compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3C x 16Sq.mm (AL)
Supplying and making end termination with brass double compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3C x 25Sq.mm (AL)
Supplying and making end termination with brass double compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 4C x 4Sq.mm (CU)
Installation ,testing and commissioning of PMCC
ITC ( Installation , testing and commissioning ) of PMCC panel board 3 phase 415 volt floor standing. Panel board dimension 3000mm x 2206mm x 1037mm. (L x H x W) . Drawing and technical parameter of panel board details are attached herewith. Work includes leading the PMCC from storage room to proposed site, PMCC was supplied in two pieces, fixing the panel board safely on proposed site as per electrical standard. Checking the alignment of PMCC and interconnecting its bus bars and control wires as per diagram and make it as single unit. Fixing the panel board on floor by using anchor bolt. Necessary testing shall be performed like IR value of busbar, ACB testing like Timing test, CRM etc and commissioning of PMCC
Earthing
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
Providing and fixing 8swg Cu wire on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 3 mm G.I. strip on surface or in recess for connections etc. as required
Providing and fixing 25 mm X 6mm Cu earth bench heavy duty length 300mm on surface for connections etc. as required.
Supply and laying of ELECTRICAL insulation mat (IS 15652/2006)) size 2mm thickness class A 2mm thickness
cable, local push button station, welding main,juction boxes
Supply and fixing of Weatherproof Start/Stop(2way) Push Button Station With Ammeter, material- cast aluminum alloy , IP 65 as per IS /IEC 6052 92001. Gasket Neoprene, cable entry -3 Nos. 3/4" ET Entry, Start PB- Green Colour,Momentary Type, Stop PB- Red Colour, Mushroom Head, Pad Lockable or Key Lockable type, Ammeter range 0-200 amp ( CT ration 200/1Amp) including all the necessary accessories as required complete with suitable mounting arrangement, Make :Pushtron,Voltech, Tricon or equivalent
Supply of 8C 1.5 sqmm Cu 1.1 KV grade PVC insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date
Supply of 4C 6 sqmm Cu 1.1 KV grade PVC insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date
Supply, installation, testing and commissioning of four pole 40A, 415V isolator in<br>sheet steel enclosure with all accessories as required complete
Supply and fixing of Weatherproof Start/Stop(2way) Push Button Station With Ammeter, material- cast aluminum alloy , IP 65 as per IS /IEC 6052 92001. Gasket Neoprene, cable entry -3 Nos. 3/4" ET Entry, Start PB- Green Colour,Momentary Type, Stop PB- Red Colour, Mushroom Head, Pad Lockable or Key Lockable type, Ammeter range 0-75 amp ( CT ration 75/1Amp) including all the necessary accessories as required complete with suitable mounting arrangement, Make :Pushtron,Voltech, Tricon or equivalent
FRP Enclosure (Juction Box) with terminal blocks , cable entry from bottom 250 x 200 x 155 mm material FRP. Terminal bock 4nos with current carrying capacity 16Amp
DB, MCB Wiring
Supplying and fixing following way prewired TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming andoutgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate,interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/Isolator)4 way ( 4+12), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2X2.5 sq.mm+1X2.5 sq.mm earth wire
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2x4 sq.mm + 1x4 sq.mm earth wire
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A
Supply of LED batten 18 watts cool day light and including all necessary accessories as required complete.Make:- Wipro/ bajaj/philips/crompton
Supply of LED outdoor flood light luminaire. The fixture shall be of IP66 protected, pressure die cast aluminium housing body with optimal heat sink, with system wattage less 45W with rated life of L70 @ 50,000 hours, CRI greater than or equal to 70 & with system lumens greater than 3500 lumen and system efficacy greater than or equal to 95%.Make Wipro/Philips/bajaj/crompton
Supply of 3C 1.5 sqmm Cu 1.1 KV grade PVC insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date
Installation, testing and commissioning of High bay/Mid bay/LED/ FLOOD type fittings on wall/Column/truss/false ceiling using suitable MS clamps, nuts, bolts/ 20mm heavy duty GI chain/ pipe (upto 50cm)etc including connections with 3C 1.5 Sq.mm PVC insulated flexible copper conductor cable and copper lugs etc as required.
Installation, testing and commissioning of pre-wired, LED/ fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single corecable and earthing etc. as required
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .