Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.4 LAccepted-AOC | L1 | Accepted-AOC aoc | |
| 2 | L2₹22.0 L+₹61,866 (2.90%)Rejected-Finance | L2 | Rejected-Finance L1 being accepted |
Tender Value
Refer Docs
EMD Value
₹48,000
Closing Date
17 Nov 2020, 6:00 pmClosed
CWE AF TRIVANDRUM
CWE AF TRIVANDRUM HQ SAC IAF COMPLEX AKKULAM THURUVIKKAL POST TRIVANDRUM 11
SPECIAL REPAIRS TO BLDG NOS T2 TO T9 AT AF STN SURYALANKA
2020_MES_388266_1
CWE(AF)/TVM/SUR/82321
Open Tender
Civil Works
Item Rate
180 days
Suryalanka
As per NIT
7 documents required · 7 mandatory
₹500
AGE I AF Suryalanka
₹48,000
Yes
7 Jan 2021
20 Oct 2020
19 Nov 2020
20 Oct 2020
17 Nov 2020
3 Nov 2020
20 Oct 2020 - 28 Oct 2020
Amount
SCHEDULE 'A'
Taking down cement or cement lime plaster, any description, on brick walls including racking out joints hacking for key scrubbing down with water etc. all as specified and directed.
Demolition of Brick work built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stone work and precast concrete articles complete all as directed.
M&L for rendering 10mm thick on fair faces of brick or concrete in CM 1:6 finishing even and smooth with out using extra cement all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in two layers, first layer 10 mm thick in CM 1:6 and second layer 5 mm thick in CM 1:4 finishing fair and even mixed with WPC as per manufacturer's instructions all as specified and directed. (Note : Supply of water proofing compound shall be measured and paid seperately).
Supply only of integral water proofing compound of approved make all as specified and directed.
M&L for Brickwork with sub-class `B' old size bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:4 all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), and aprons removing serviceable tiles to store and rubbish off the premises all as specified and directed.
M&L for joint free Non Skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15 mm thick screed in cement mortar mortar 1:6 all as specified and directed.
M&L for Non Skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15 mm thick screed in cement mortar 1:6 all as specified and directed.
M&L for Glazed ceramic coloured tiles 300 x 200 size 7 mm thick in vertical surfaces as in dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including 10mm thick backing coat in cement mortar 1:4 all as specified and directed.
Taking down chowkats or frames (without taking off shutters from frame) not exceeding 1.5 sqm each including making good disturbed portions with PCC 1:2:4 type B-0 or in cement mortar 1:4 after removal of frames all as specified and directed.
Taking down chowkats or frames (without taking off shutters from frame) exceeding 1.5 sqm but not exceeding 4 Sqm each including making good disturbed portions with PCC 1:2:4 type B-0 or in cement mortar 1:4 after removal of frames all as specified and directed.
S&F of Pressed steel frames 125 x 60mm size for doors with double rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete,all as specified and directed.
M&L for Plain cement concrete 1:3:6 type C-0 using 12.5 mm graded stone aggregate for filling of hollow portions of door frames etc., all as specified and directed.
S&F of 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides all as specified and directed.
S&F for 35 mm thick second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass,gauze etc. edges of framing plain, chamferred or rounded, fitted with cut and mitred beads for securing glass, wire gauge etc. ; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) fitted to chowkats all as specified and directed.
M&L for powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleats for fixing etc., complete all as specified and directed by Engineer-in-charge.
S&F of powder coated anodised aluminium window and ventilator glazed shutters, side hung type without sash bars aluminium sections weighing 0.55 kg/s (standard aluminium section of DG-2496 of sizes 39.4 x 17.7 mm and 1.2 mm thick (min) including necessary jointing cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No), hinges type B-21, 100mm long (2Nos), suitable handle (1Nos) for each shutter complete all as specified and directed by Engr-in-charge.
S & F of Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples or wooden/aluminium beads all as specified and directed.
S&F of 4 mm thick Sheet Glass, ordinary quality and glazing fixed to windows square exc 0.50sqm in each pane all as specified and directed.
S&F of 4 mm thick Figured glass, pin head type and glazing with aluminium beads all as specified and directed.
S&F 200 mm long Aluminium anodised barrel tower bolts of extruded aluminium section all as specified and directed.
S&F of 100 mm long Aluminium anodised barrel tower bolts of extruded aluminium section all as specified and directed.
S&F of 150 mm long Aluminium alloy handles cast type anodised all as specified and directed.
S&F of 100 mm long Aluminium alloy handles cast type anodised all as specified and directed.
S&F 75 mm long Aluminium butt hinges extruded aluminium alloy with galvanised steel wire pin anodised, type C-22 all as specified and directed.
S&F of 300 mm long aluminium alloy anodised sliding door bolts with hasp and staple (bolt type) and fixing clip of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy all as specified and directed.
S&F of Mild steel 300 mm ,ordinary rat & tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F of factory made PVC Solid Door frame of size 50mmx47mm made out of 5mm plain coloured PVC sheet reinforced with MS Square tube, fixed in opening as per specification and dawings.
S&F of Factory made Solid panel PVC Door Shutter of 30mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail ; Panelling of plain clour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement as per specification
S&F of vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, anti-syphonage pipe, etc., fixed in repairs complete including making good to floor all as specified and directed by Engrineer-in-Charge.
S&F of 10 lit capacity PVC valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, fixed in repairs, all as specified and directed by Engineer-in-Charge.
S&F in repairs Vitreous China wash basin, white, flat back, of size 550x400 mm excluding taps, waste chain and plug and porcelain stopper but including brackets and brass, 32 mm dia chromium plated waste fitting and 40 mm bore PVC waste pipe all as specified and directed by Engineer-in-Charge.
S&F of CP Pillar taps fancy type 15 mm bore, cast copper alloy, with capstan heads screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks and fly-nuts, screwed for iron pipe, all as specified and directed.
S&F in repairs of 20 mm bore Gun-metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed all as specified and directed.
S&F in repairs of Stop valves 15 mm bore, cast copper alloy screwed down high pressure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions, all as specified and directed.
S&F in repairs 15 mm bore Bib taps, chromium plated, cast copper alloy, screwed down, screwed for iron pipe, all as specified and directed.
S&F of PVC connections 15mm size with PTMT nuts of length 450 mm all as specified and directed.
S&F of Towel rail 600 mm long of PTMT minimum weight 190 gms, fixed with and including chromium plated brass screws and wooden / plastic cleats all as specified and directed..
S&F of 20 mm outer dia 3 layer PP-R poly-propylene random copolymer concealed pipes SDR 7.4 (PN-16) UV stabilized and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc., including taking up or down steel tubing and connections all as specified and directed.
S&F of 25 mm outer dia 3 layer PP-R poly-propylene random copolymer concealed pipes SDR 7.4 (PN-16) UV stabilized and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc., including taking up or down steel tubing and connections all as specified and directed.
M&L for Preparing new or previously un treated surfases of wood and wood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer all as specified and directed.
M&L for preparing new or previously untreated surfaces of steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of exterior weather coat paint over a coat of primer all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying three coats of white wash all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer all as specified and directed.
M&L for preparation of old painted surfaces of walls and applying one coat of oil bound distemper all as specified and directed.
S&F of 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls or laid in floors as in soil, waste and pipes including dismantling of old pipes all as specified.
S&F of 110 mm bore PVC (SWR) bends any radius provided with access door, fixed in repairs all as specified.
S&F of 110 mm bore PVC (SWR) junction, single (Single T) equal or unequal provided with access door, fixed in repairs all as specified.
S&F of 110 mm bore PVC (SWR) Vent cowl fixed in repairs all as specified.
S&F of 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls or laid in floors as in soil, waste and pipes including dismantling of old pipes all as specified.
S&F of 75 mm bore PVC (SWR) bends any radius provided with access door, fixed in repairs all as specified.
M&L PVC (SWR) floor trap 75mm dia plain with grating including jointing with solvent cement , fixed in repairs all as specified.
Dismantling of old water tank exc 250 Ltr & n.exc 500 Ltr capacity and removing from store etc complete all as specified and as directed.
S&F rotational moulded polyethylence water storage tanks IS : 12701 - 1996 marked (cylindrical vertical with closed top) of 500 Ltrs capacity with and including 20mm dia Ball brass valve high pressure with polythene float and fly nut screwed for iron pipe or brass and fixed etc complete all as specified and as directed.
Dismantling of asbestos cement (corrugated, semi corrugated etc) sheets in roof covering etc complete all as specified and as directed
Supply and fixed pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws etc complete all as specified, directed and as per manufacturer's instructions.
M&L for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of Fe 550 Mpa as in roof ridge fixed with self tapping screws as specified.
Dismantling of AC sheet plain ceiling boards any type or any thickness including cover fillets etc complete all as spd and as directed.
S&F anodised aluminum snap grid frame work of size 605mm x 605mm for false ceiling and hangers 6mm dia G.I (upto 1200mm length) adjustable level fixed to roof slabs by means of ceiling cleats made out of GI falt 40 x 3mm size 60mm long and expansion hold fasterners 12.5mm dia, 40mm long complete all as spd and as directed.
S&F Gypsum board 12mm thick in ceiling fixed with screws to aluminium snap grid (frame of size 605mm x 605mm) as per manufacturers instructions complete all as spd and directed.
Dismantling of framed roof truss not exceeding 10m span complete all as spd and as directed.
Dismantling of timber scantlings under 40 Sqcm in fillets, rails, runners, purlins unframed work (Runners/battons) complete all as spd and as directed.
S&F rolled mild steel in roof trusses (framed) Fe-290 (Gde-E-165), trussed, purlins, crane gantries, rails and fastenings and heay bracket framing (beam, tee, angle, channel of flat sections) including distance pieces, cleats etc complete all as spd and as directed.
M & L Rolled mild steel sections conforming to Fe-290 (Gde E-165) as in main and cross beams, hip and jack rafters; purlins where connected to common rafters fixed with angle cleats or other connecting plates complete all as spd and as directed.
Demolition of cement concrete in ground floors, not exceeding 15cm thickness (below or above ground level) including removal of demolished material out side MD land complete all as specified and directed by Engr-in-Charge.
M&L 100mm thick cement concrete type D-2 1:4:8 using 40mm graded aggregate as in sub base complete all as specified and as directed.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M35 grade with grey cement and pigment all as specified and directed.
M&L for Sand filling under floors / pavings, below tiles, including watering and consolidation all as specified and directed.
M&L for providing cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in edge restraints, kerbs etc for interlocking tile., complete all as specified and directed by Engineer-in-charge..
Taking down ceiling fan complete removing the down rod of existing length and providing new down rod/ pendent of length not less than 1.5 metre, brass with cord grip pattern, and 0.5Sqmm copper flexible twisted twin cord upto 1.5m length for refixing celing fan all as specified and directed
M&L for point wiring complete with 1.5 Sqmm single core multistranded copper conductor, FRLS, PVC insulated unsheathed cable 1100 volts grade fixed in and including concealed PVC conduit, fitting and accessories, joints boxes including one 1.5 sqmm copper FRLS PVC insulated unsheathed as earth continuity conductor connected in the common earth complete all as specified and as directed including taking down existing point wiring for Light/ Fan/ Exhaust fan/ Independent 5 A Socket/ Security light complete all as specified and as directed.
All as per item No. 75 above but for One 5 pin socket outlet 5 amps on same board controlled by one switch all as specified and as directed.
All as per item No. 75 above but with 2.5 sqmm Single core wiring for Phase, neutral and earth for Independent 15 Amps power socket all as specified and directed
S&F in replacement Modular socket, 6A, 5 pin combination 2 module complete all as specified and as directed.
S&F in replacement modular switch socket combination 16A, 6 pin, 3 module complete all as specified and as directed.
S&F in replacement modular switch one way 6 Amps, 1 module complete all as specified and as directed.
S&F in replacement of modular Fan regulator electronic step type, 120W- 2 module, 240V single phase complete all as specified and as directed.
S&F in replacement modular white cover plate with frame and metal flush box, 2 module complete all as specified and as directed.
S&F in replacement modular white cover plate with frame and metal flush box, 3 module complete all as specified and as directed.
S&F in replacement modular white cover plate with frame and metal flush box, 6 module complete all as specified and as directed.
S&F in replacement ceiling rose, 3 plate PVC/polycarbonate, isolated body complete all as specified and as directed.
S&F in replacement submain wiring with two run of single core cable FRLS PVC insulated sheathed cable 1100 volts grade 4 Sqmm copper multistranded conductor including and drawing into concealed/Surface PVC conduit, fixed on/in wall, ceiling including 4 sqmm FRLS PVC insulated unsheathed multistranded for earth wire connected to earth complete including taking down existing submain wiring complete all as specified and as directed. Note: Three runs of cable and one run of conduit shall be measured as one unit.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point including testing on completion and complete all as specified and as directed by Engr-in-Charge.
S&F MCB DB Double door , SPN 04 way IP 54, fixed to wall in concealed by disturbing the existing wall surface and making good complete all as specified and as directed.
S&F MCB SPN 6-32Amps, C Curve, 10kA complete all as specified and as directed.
S&F MCB SP 6-32Amps, C Curve, 10kA complete all as specified and as directed.
S&F in replacement 4 Feet LED Tube light of 20 Watt with surface and wall mounted Batten,extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver connected upto ceiling rose including taking down exisitng Tube light fitting of any type complete all as specified and as directed by Engr-in-Charge
S&F in replacement 2 Feet LED Tube light of 20 Watt with surface and wall mounted Batten,extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver connected upto ceiling rose including taking down exisitng Tube light fitting of any type complete all as specified and as directed by Engr-in-Charge
S&F lamp holder PVC/Polycarbonate type with cord grip cap suitable for pendant fittings complete all as specified and as directed by Engr-in-Charge.
Supply and lay in trenches/on wall/on pole/in duct /through protection pipe including testing and jointing XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables heavy duty LT cable, 1100 volts grade with aluminium conductor cross sectional area 16 Sqmm 2.0 core size complete all as specified and as directed.
M&L for galvanised steel tubing 25mm light grade, IS-1239 marked with all fittings ISI marked and laid in trenches/road crossing/floor or fixed to pole/wall with all fittings, with required size flat iron clamps, bolts, nuts and washers, pipes complete all as specified and as directed.
Excavation in trenches in soft/loose soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth for laying of cable, RCC poles, stays and struts etc and not exceeding 10 Sqm on plan . and not exceeding 1.5 m in depth and getting out including trimming sides and forming bottom surface complete all as specified.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers n. exc. 25cm thick in soft/loose soil. complete all as specified and as directed. Note: The back fill shall be neatly rolled/ levelled over the trench to a sufficient height to allow for settlement to the required level all as specified in clause 18.56 of SSR Part I
M&L for sand cushioning to underground cable including punning down of sand layer all as specified and directed. Note:- Punned thickness shall only be measured and paid.
M& L for laying common burnt bricks, sub class 'B' of size 230x115x75 cm in trenches for cable protection complete all as specified and as directed.
Supply installation, commissioning and testing of LT Feeder Pillar Box out door type, double door made out of CRCA sheet of 3.15 mm thick with powder coted painting frame made out of angle iron 45 x 45 x 6 mm and four numbers of 100 Amps Aluminum strips / bars duly insulated on insulator/ suitable size Ba kelite sheer, free space between MCCB/ busbar and other connection items should be provided, the space between ground and panel should be 60cm with PCC foundation for LT panel, LT panel should be provided with necessary locking arrangement, danger notice sticker, cable glands, internal wiring with FRLS copper wires and comprising and including the following: Incoming a) MCCB 4 pole, 63 Amps, 10 KA.- 01 No. fixed thermal and magnetic setting type Outgoing a) MCB 2 pole, 6-32 Amps, 10 KA.- 06 No (4 for Bldg, 2 Spare ) b) MCB 4 pole, 6-32 Amps, 10 KA.- 01 Nos c) Intelligent panel meter to measure voltage, current, frequency, power factor, kWH , etc with all connected CTs d)LED indicating lamps with colour Red, Yellow, Blue-01 set
S&F exhaust fan AC single phase 230/240volts of 900rpm complete with louvers of size 300mm sweep complete all as specified and as directed.
Making a circular hole on existing brick wall at height less than 3mtrs from floor, and making good with proper cement plastering, paint to match the surrounding walls for fixing of any sweep ventilating fan. Note: The demolished PCC material should be removed at a distance not less than 50mtrs from site.
Total of Schedule 'A'
K VENUGOPALA SWAMY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .