Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹31.9 LAccepted-AOC B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | ₹31.9 L Quoted ₹33.3 L | 1 | Accepted-AOC AOC |
| 2 | 2₹37.1 L+₹3.8 L (11.5%)Rejected-Finance | ₹37.1 L+₹3.8 L (11.5%) | 2 | Rejected-Finance NOT L1 |
| 3 | 3₹38.6 L+₹5.3 L (15.9%)Rejected-Finance | ₹38.6 L+₹5.3 L (15.9%) | 3 | Rejected-Finance NOT L1 |
| 4 | 4₹39.6 L+₹6.3 L (18.9%)Rejected-Finance 203 NABIL APARTMENT ASHOK NAGAR OPP HATHIKHANA ANAJ MARKET TULSIWADI ROAD KARELIBAUG VADODARA 390018 GUJARAT | VADODARA | GUJARAT | 390018 | ₹39.6 L+₹6.3 L (18.9%) | 4 | Rejected-Finance NOT L1 |
| 5 | 5₹40.8 L+₹7.5 L (22.4%)Rejected-Finance H NO 05 AASI BAUG OPP VATSALYA SCHOOL BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | ₹40.8 L+₹7.5 L (22.4%) | 5 | Rejected-Finance NOT L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
27 Jul 2022, 6:00 pmClosed
GE(ARMY) BHUJ
GE(ARMY) BHUJ
REPAIR/REPLACEMENT TO UNSERVICEABLE INTERNAL WIRING INCLUDING FITTING AND PAINTING OF CEILING FANS,EXHAUST FAN ,GEYSER , AC ,WATER COOLERS,REFRIGERATOR ETC AT MIL STATION GANDHIDHAM
2022_MES_533759_1
8922
Open Tender
Civil Works - Others
Item Rate
270 days
ARMY AREA GANDHIDHAM
REFER TENDER
6 documents required · 6 mandatory
₹500
GE(ARMY) BHUJ
₹60,000
Yes
13 Nov 2022
27 Jun 2022
28 Jul 2022
27 Jun 2022
27 Jul 2022
15 Jul 2022
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including fitting and fixture and such as as switches, sockets ceiling rose,pendent holders,regulators,light fittings any type removing materials to store in safe custody or for credite etc, and making good the disturbed surface of walls and floors etc as directed.
M&L for point wiring with two single core PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm 1100 volts grade in and including PVC casing capping of size 20 to 25 mm with all accessories and one single core PVC insulated unsheathed solid copper cable of size 1.5 Sqmm 1100 Volts grade as earth continuity conductor connected to common earth dolly, switch board complete with PVC rectangular type box heavy duty for mounting the switch socket etc complete as specified for the following :- (a) One light/Fan point controlled by one 5 Amps switch one way complete NOTE :- (i) Quoted rate shall be deemed to include the cost of cutting chases in walls / pillars /column etc. of any description for concealing the boxes to required depth & making good the disturbed surface in CM 1:4 including finishing the surface to match with the existing surface. (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'.
- ditto-- but One bell point controlled by one 5 Amp bell push complete
--dotto-- but one 5 Amp socket point controlled by one 5 Amp switch independent board with cable 2.5 sqmm.
–ditto- but on the same board.
--ditto--' one light point controlled by two Nos two way switchs
All as per item No.02 here-in-before but with two single core PVC insulated unsheathed copper conductor cable of size 2.5 Sqmm 1100 volts grade and one single core PVC insulated unsheathed solid copper conductor cable of size 2.5 Sqmm 1100 Volts grade as earth continuity conductor for 3 pin 15 Amps socket point on independent board complete all as specified and as directed.
All as per item No 02 but wiring in existing PVC conduit/Casing capping cleaning the existing steel terminal boxes and painting with two coat of black bituminous paint over a coat of red oxide primer all as specified for:- (a) One light/fan point controlled by one switch
--ditto-- but one bell point controlled by one 5 Amp bell push complete
--ditto-- but One 5 Amp socket point controlled by one 5 Amp switch independent board with cable 1.5 sqmm.
--ditto-- but on the same board.
All as per item No 08 herein before but using 2.5 sqmm, PVC insulated, stranded copper conductor single core cable for one 3 pin 15 Amp socket out let point on an independent board
M&L for concealed point wiring with two single core PVC insulated & PVC unsheathed stranded copper conductor cable of size 1.5 Sqmm 1100 volts grade in and including making good the distrubed surfaces of wall with clour washing/ distemparing the surface to match the existing including PVC concealed conduict of size 20 to 25 mm with all accessories and one single core PVC insulated & PVC sheathed solid copper cable of size 1.5 Sqmm 1100 Volts grade as earth continuity conductor connected to common earth dolly, switch board complete with MS rectangular type box heavy duty for mounting the switch socket etc complete as specified for One light/Fan point controlled by one 5 Amps switch one way complete. The quoted rates shall be deemed to be inclusive for provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick laminated sheet fixed with suitable brass screws and cup washers
Same as above item No 13 but point wiring for One 5 Amp socket point controlled by one 5 Amp switch on same board with cable 1.5 sqmm.
Same as above item No 13 but point wiring for One 5 Amp socket point controlled by one 5 Amp switch independent board with cable 1.5 sqmm.
All as per item No.13 here-in-before but with two single core PVC insulated & PVC unsheathed copper conductor cable of size 2.5 Sqmm 1100 volts grade and one single core PVC insulated &PVC sheathed solid copper conductor cable of size 2.5 Sqmm 1100 Volts grade as earth continuity conductor including PVC surface / concealed conduict of size 20 to 25 mm with all accessories for 3 pin 15 Amps socket point on independent board complete all as specified and as directed.
S&F switch piano flush type 6 Amp. AC, 240 Volts one way all as directed.
S&F switch piano flush type 15 Amp. AC, 240 Volts one way all as directed.
S&F socket outlet flush type 2 in one 3 pin 5 Amp, AC, 230 volts , complete all as directed.
S&F socket outlet flush type 2 in one 3 pin 15 Amp, AC, 230 volts , complete all as directed.
S&F bell push flush type single pole one way, 5 Amp, AC,230 V all as directed with frame cover
S&F switch socket combination. Multi purpose 6 Pin 6 Amp flush type AC, 230V complete all as directed.
S&F switch socket combination. Multi purpose 6 Pin 16 Amp flush type , AC, 230V complete all as directed.
S&F ceiling Rose, surface, bakelite 65 x50 mm three terminals, AC, 230 Volts complete all as directed.
S&F angle holder backelite with insulated body AC, 230V complete all as directed.
S&F bell electric AC, 230V, Single phase, Dingdong type complete all as directed.
S&F step type electronices fan regulator flush type, 100 watt, AC, 230V, Single phase, complete all as directed.
S&F modular type electronices fan regulator, 100 watt, AC, 230V, Single phase, complete all as directed.
S&F Modular switch 1 way 6A 1 module type all as directed.
S&F Modular switch 1 way 16A 1 module type all as directed
S&F Modular Socket 6A/16A - 2/3 pin combined 2 module all as directed.
S&F Modular Switch socket Combination 16A, 6 pin, 3 module all as directed.
S&F MCB protected socket combination including MCB of capacity 25 Amps with steel sheet/ plastic enclosure with plug top, AC, 230V complete all as directed.
M&L for LED tube light fitting. 1 x20 W flameproof type FLP-WP made of aluminium alloy LM6 complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size, complete all as specified & approved by EIC.
M&L for Switch flame proof rotary type with termination box in LM6, 16A, single pole 250Volt, complete all as specified & approved by EIC.
M&L for Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 26A, 250V, 2P+earth, complete all as specified & approved by EIC.
S&F in repair square recessed / surface/suspended mounting LED slim ceiling light with extruded aluminium housing and milky diffuser of 36 W 2'X 2' slim panel LED driver 240 V ,50 Hz complete all as specified & approved by EIC.
S&F in repair decorative box type fitting with LED tube 18 to 20 watt for 230 volt AC complete including making all connection using 1.5 sqmm copper conductor muilstranded PVC insulated 3 core flexible cable from ceiling rose to fitting drawn through in PVC flexible conduit all as specified & approved by EIC.
Supply and fixing of surface and wall mounted LED batten of capacity 20 Watt LED complete including making all connection using 1.5 sqmm copper conductor muilstranded PVC insulated 3 core flexible cable from ceiling rose to fitting drawn through in PVC flexible conduit complete all as per directed by Engr-in-charge.
S&F in repair LED tube RETRO LED 18 to 20 watt of size 4 ft long complete all as specified & approved by EIC.
M&L for Sleek LED mirror light 10 watt rating with diffuser 2ft long twisted flexible copper wire complete all as specified & approved by EIC.
S&F in repair decorative surface mounting LED dwonlighting with white diffuser 05 watt luminaire for 230 volt AC complete all as specified & approved by EIC.
S&F in repair decorative surface mounting LED dwonlighting with white diffuser 10 watt luminaire for 230 volt AC complete all as specified & approved by EIC.
S&F in repair decorative surface mounting LED dwonlighting with white diffuser 20 watt luminaire for 230 volt AC complete all as specified & approved by EIC.
M&L in repair for submain wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable of size 6 Sqmm 1100 volts grade and one run of PVC insulated unsheathed solid copper conductor cable of size 6 Sqmm 1100 volts grade as earth continuity conductor drawn through in and including rigid non metallic PVC concealed / surface conduit of suitable size on roof/wall/ceiling including making good the disturbed surfaces of wall etc including taking out old unserviceable burnt/damaged sub main wiring from its existing position complete all as directed by Engr-in-Charge (Note : Two run of single core cable and one run of earth wire will be measured as one length and conduit and its accessories is deemed to be included in the unit rate).
M&L in repair for submain wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable of size 4 Sqmm 1100 volts grade and one run of PVC insulated unsheathed solid copper conductor cable of size 4 Sqmm 1100 volts grade as earth continuity conductor drawn through in and including rigid non metallic PVC concealed / surface conduit of suitable size on roof/wall/ceiling including making good the disturbed surfaces of wall etc including taking out old unserviceable burnt/damaged sub main wiring from its existing position complete all as directed by Engr-in-Charge (Note : Two run of single core cable and one run of earth wire will be measured as one length and conduit and its accessories is deemed to be included in the unit rate).
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed flexible two core cable flat or circular of size 6 Sqmm solid aluminium conductor all as specifiied and directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed flexible two core cable flat or circular of size 10 Sqmm solid aluminium conductor all as specifiied and directed.
Taking down old unserviceable main switches/DB’s up to 100 Amps capacity fixed in wall and making good of all disturbed surfaces as per existing .
S&F sheet metal enclosure for DB’s when MCB to be used single pole and neutral double door, 4 way, AC,240 volt with 200 Amp bus bar rating complete all as directed.
S&F sheet metal enclosure for DB’s when MCB to be used single pole and neutral double door, 8 way, AC,240 volt with 200 amp bus bar rating complete all as directed.
S&F sheet metal enclosure for DB’s when MCB to be used single pole and neutral double door, 12 way, AC,240 volt with 200 Amp bus bar rating complete all as directed.
S&F sheet metal enclosure double door (MCB DB) three phase and neutral with 200 Amps rated bus bar TPN, 4 way horizontal type, with provision of MCB incommer, AC, 415 Volt complete all as specified & directed.
S&F sheet metal enclosure double door (MCCB DB) three phase and neutral with 200 Amps rated bus bar TPN, 4 way vertical type, with provision of MCCB incommer, AC, 415 Volt complete all as specified & directed.
S&F MCB single pole, 6 to 32 Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as directed.
S&F MCB single pole, 40 to 63 Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as directed.
S&F MCB DP 32 to 63 Amps 240 Volts, 50 Hz, 10 KA breaking capacity complete all as directed.
S&F MCB Four Pole 40 to 63 Amps 415 Volts, 50 Hz, 10 KA breaking capacity complete all as directed.
S&F MCB Four Pole 100 Amps 415 Volts, 50 Hz, 10 KA breaking capacity complete all as directed.
S&F MCCB 4 pole 100 Amp 415 volts 50 HZ 16 KA breaking capacity complete all as directed.
Material and labour for maintanance/enhancement of earthing resistance of existing earthing complete with necessary excavation and earth work, complete for chemical treatment of existing earth electrode with Benzonite Powder solution (2x25Kg in each bag) sourounding the earth plate to get the earth resistance lessthan 1 ohm. including pouring of salt water as required minor repairs for jointing/ welding as required. including testing of earth pit submission of test result duly signed by user rep. all as directed by Eng-incharge.
S&F Founten light of 5 watt LED of different colours IP 68 protection as required at site Complete all as specefied and directed by Eng -in-Charge. Make :-
S&F for sheet metal enclosures with two pin and earth plug sockets controlled by one No. MCB rating 20 Amps , 240 Volts grade, double door type complete.
M&L , Earthing complete with galvanisedsteel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completionI connected to main board / disribution board complete .Earthing GI lead and GI protection pipe 15 mm dia light grade upto 7.5 m from earth pit connecting to machinary/ equipment, testing point, all as specified and testing on completion all as per directed.Note :- (i) The unit rate shall also included for earth work in hard /dense soil , PCC type C-I (1:3:6) chamber , PCC 1:2:4 type B-I cover 50 mm thick reinforced with 8 mm dia TMT bars,150 mm c/c both ways, funnel with watering pipe 20 mm dia medium graded , GI protection pipe light grade 15 mm dia and wire mesh complete in addition to items No. 1(a) to (e) of preamble (notes) under sub heading earthing specified on SI page No. 389 of SSR Part - II.(ii) Earthing lead and GI protection pipe beyond 7.5 mtrs will be measured and paid separatelly if required under appropriate Schedule.Note :- (i) Earthing shall be tested as specified in casul 19.137 of SSP PART - I 2009 , to the entire satisfication of Engr-in-Charge. (ii) On teting after complataion of earthing , if the desired earth resistance is not obatined the earthing wiil be re done by the contractor at his on risk and cost to the entire satisfaction of the Engr - in - charge.
Taking down carefully ceilling fans of any size, type by disconnecting the wires and dismanting blades and removing fan and blades to contractor,s workshop or site for repair/ overhauling/re winding/painting etc including re fixing after neccesary repair complete all as specified and directed by Engineer-in-charge (Note|-Parts/components will be measured and paid seperately under their respective items)
Description all as per sil item No 65 here in before but for exhaust/cabin fans of any size/make
M&L for servicing/oiling and greasing of fan of any size/type by using appropriate grade of oil/grease and replacing defective parts such as bush, bearing split pin rubber bush hanging clamp capacitor including cleaning for fixing the same as directed by Engineer- in -Charge (Note|-Parts/components will be measured and paid seperately under their respective items)
M&L for rewinding of celling fan 1200mm /1400mm sweep, AC, 230 volts single phase with super enamelled copper winding wire of appropriate size including packing, insulating material soldering varnishing assembling and testing as required complete all as specified and directed
S&F bearing of celling fans for celling fans of 1200/1400mm sweep suitable for different makes /type of fans.
S&F bushes gun metal suitable for celling fans 1200/1400mm sweep/exhaust fan 300 to 450mm sweep/cabin fan of any size complete all as directed by Engr-in-Charge
Rewinding of exhaust fan 300mm to 450mm sweep AC 230 volts single phase with super enameled copper wire of appropriate size including packing insulating material, soldering, varnishing , assembling and testing complete all as specified
Description all as per srl item NO 71 here- in- before but for cabin fan of any size/make.
S&F ball bearing suitable for exhaust fan 300 to 450mm sweep of different make, all as directed.
S&F rubber reel type synthetic rubberwith 14.5mm hole suitable for hooks of celling fans, all as specified and directed by Engr-in-Charge.
S&F nuts, bolts and washers of appropriate size for hanging of celling fan including split pins of galvanished iron 1/8" dia, 2" lengthall as specified and directed by Engr-in-Charge.
S&F top/botton (Set of Two) canopy of required size complete with tightening screws, all as directed.
S&F down rod 30cm long made out of heavy grade MS pipe with necessory threading at both ends holes as required with suitable matching colour of ceiling fan 1200/1400mm all as directed
S&F condenser/capacitor suitable for 230 volts singls phase celling fan 1200mm/1400 sweep of approved make and quilty of capacity 2.5 MFD all as directed
Description all as per item No78 here - in - before but capacity 4 MFD for exhaust fan of approved make and quality
S&F fan blade made out of M S sheet suitable for any make , sweep and colour of celling fans as directed at site by Engr-inCharge
S&F fan blade (set of three), complete with tightening bolts/screws, made of suitable for any make and colour of exhaust fan as directed at site by Engr- in -Cgarge
Description all as per srl item No 87 here - in - before but for cabain fan of any make and size
M&L for Painting of celling fan 1200/1400mm sweep AC 230 volts single phase complete in site or at contractor workshop with synthetic enameled white/maching paint by spraying one coat including filling of cavities after cleaning all dust complete , all as specified and directed by Engineer-in-Charge .
S&F exhaust fan frame made out of MS sheet for any make and size of exhaust fan with suitable size of nuts, bolts lugs and washers complete, all as specified and directed by Engineer-in-Charge .
Painting of exhaust fan 300 to 450 mm sweep AC 230 volts single phase complrtr with synthetic enameled white/grey/matching paint by spraying one coat including filling of cavities after cleaning all dust, all as specified and directed by Engineer-in-charge.
Dismantling of geyser from its location 03/06/25/50Ltrs cap and making leak proof by means of welding of tanks replacement of parts, under item No 2 and one coat of primer for inner tank re-assembling, including packing of glass wool properly replacement of worn out nut bolts washers screws as reqd and re fixing after neccesary repair of complete set to work after one coat of synthetic enamelled paint as directed by Engr-in-Charge.
Supply only of following items for geyser complete.
(a) Apparatus plate heavy duty rubber gasket suitable for 03/06/25/50 Ltr of any size and directed by Engr-in-Charge.
(b) Geyser element 1.5 KW, all as specified. Make :- Theata/Venus
(b) Geyser element 2.0 KW, all as specified. Make :- Theata/Venus
(d) Thermostate switch ISI Marked.
(e) S/S inner tank Capacity 25 Ltrs heavy duty .
(f) S/S Copper inner tank capacity 06 ltr heavy duty .
(g) S/S Copper inner tank capacity 50 Ltr heavy duty .
(h) Indicator lamp of any type/colour.
(i) Top and bottom cover of outer body of any type Geyser suitable for 03/06/25/50 lts capacity including two coats of synthetic enamelled paint and preparation of surfaces. All as specified.
(j) CP connection 450mm long nylon braided and double flat with nut and washers both side complete all as specified.
(k) -do- but of size 300mm long.
(l) Copper flexible cable PVC insulated 3 core 40/.0076 All as specified and directed.
(m) Outer body 50 Ltr capacity Geyser sutaible for exesting make.
(o) Outer body but 25 ltr capacity Geyser sutaible for exesting make.
(p) Pressure release valve ISI marked.
(q) Safty plug of geyser for 25/35/50 Ltr capacity.
(r) Plug top 3pin 15 Amps ISI Marked .
(s) Non return valve 15mm dia pipe brass made ISI marked.
Dismounting, window AC 1.5/2.0 TR to the ground level, transporting to near water point in the complex, taking out the AC from outer cover, washing the unit with soap solution jet followed by clean water jet, drying, wiping, transporting back & re-fixing at original position complete all as specified and directed by Engr-in-Charge.
Servicing of split type AC of capacity 1.5/2.0 TR capacity of any make by washing the outdoor unit condenser coil with soap water jet followed with clean water jet and indoor unit with the help of blower, wipe and clean the unit with dry cloth complete all as specified and directed by Engg-in charge. Note:- Cost of hiring T&P i.e. blower, pressure pump bucket hose pipe deemed to be included.
M&L for servicing of following appliances comprising of through cleaning, lubricating of all moving parts, replacement of wornout screws, bolts etc to make the unit for smooth operation for :-
(a) Water coolers 40 to 150 ltrs cooling capacity.
(b) Refrigerator of 165 to 310 ltrs capacity.
(c) Deep freezers of Upto 425 ltrs capacity.
Taking down defective /unserviceable AC rotary compressor of any make of capacity 1.5 TR and replacing with new rotary compressor of make Tecumseh, Toshiba, Mitsubishi, Hagelin refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge.
Taking down defective /unserviceable AC rotary compressor of any make of capacity 2.0 TR and replacing with new rotary compressor of make Tecumseh, Toshiba, Mitsubishi, Hagelin refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge.
Taking down defective /unserviceable AC reciprocating compressor of make Tecumseh /kirloskar /emerson of capacity 1.5 TR , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge.
Taking down defective /unserviceable AC reciprocating compressor of make Tecumseh /kirloskar /emerson of capacity 2.0 TR , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge.
M&L for checking for leakages, creating vacuum, charging of R-410 gas in the unit to the required pressure complete all as specified and directed by Engr-in-Charge for the following appliances:-
(a) Split type AC 1.5/2 Ton capacity.
(b) Window type AC 1.5/2.0 Ton capacity
(c) Water coolers 40 to 150 ltrs capacity.
(d) Refrigerator of 165 to 310 ltrs capacity.
(e) Deep freezers of Upto 425 ltrs capacity.
Supply and Fixing in replacement starting relay complete all as specified and directed by Engr-in-Charge. for the following appliances:-Make- Hitech
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
(c) Water coolers 40 to 150 ltrs capacity.
(d) Refrigerator of 165 to 310 ltrs capacity.
(e) Deep freezers of Upto 425 ltrs capacity.
Supply and replace capacitors of the following capactities for ACs water coolers, refrigerators, Deep frizers etc as per site requirement.
Supply, installation including brazing, jointing copper tubing superior quality of dia 5/8” completes all as specified and as directed by Engineer-in-charge.
Supply, installation including brazing, jointing copper tubing superior quality of dia 1/2” completes all as specified and as directed by Engineer-in-charge.
Supply, installation including brazing, jointing copper tubing superior quality of dia 3/8” completes all as specified and as directed by Engineer-in-charge.
Supply, installation including brazing, jointing copper tubing superior quality of dia 1/4” completes all as specified and as directed by Engineer-in-charge.
M&L for shifting of split type AC from one location to other location including fixing evaporator unit with gitties/fastner, cutting wall/concrete incl arrangement of T&P for laying copper tubing, positioning condensing unit, laying copper tubing incl brazing work, connecting drain pipe, making good disturbed surface complete all as specified and as directed by engineer-in-Charge. (Note- Any additional copper tubing required for the work is included in the item)
S&F in replacement of wire remote control ( micro- processor) unit suitable make of split type AC 1.5/ 2 TR.
Supply and replace thermostats of of following :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
(c ) Water coolers 40 to 150 ltrs capacity.
(d) Refrigerator of 165 to 310 ltrs capacity.
(e) Deep freezers of Upto 425 ltrs capacity.
Supply and replace overload protector of followings :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
(c ) Water coolers 40 to 150 ltrs capacity.
(d) Refrigerator of 165 to 310 ltrs capacity.
(e) Deep freezers of Upto 425 ltrs capacity.
Preparation of old painted surfaces of the following appliacnes, painting with two coats of synthetic enamel paint by spraying all as directed by Engr-in-charge for :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
(c) Water coolers 40 to 150 ltrs capacity.
(d) Refrigerator of 165 to 310 ltrs capacity.
(e) Deep freezers of Upto 425 ltrs capacity.
Supply and replace condenser unit of the following appliances including making of all connectiions as specified and directed by Engr-in-charge following :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
(c) Water coolers 40 to 150 ltrs capacity.
(d) Refrigerator of 165 to 310 ltrs capacity.
(e) Deep freezers of Upto 425 ltrs capacity.
Supply and replace cooling coil of following :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
(c) Water coolers 40 to 150 ltrs capacity.
(d) Refrigerator of 165 to 310 ltrs capacity.
(e) Deep freezers of Upto 425 ltrs capacity.
Supply and replace magnetic door gasket of refrigerant 165 to 310 Ltrs cpacity.
Supply and replace top cover gasket of water cooler 40 to 150 ltrs capacity.
Supply and replace freeze compartment door/cover of refrigerators upto 310 ltrs of any make.
Supply and replace ice tray with PVC cubicle separater.
Supply and replace cabinet bulb of refrigerators of suitable size and capacity.
Supply and replace internal wiring kit complete sutaible for following :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Water coolers 40 to 150 ltrs capacity.
(c) Split type AC of any make and capcity 1.5/2 ton.
(d) Refrigerator of 165 to 310 ltrs capacity.
(e) Deep freezers of any make & cap 200 to 425 ltrs capacity.
Supply and replace condenser fan motor complete with necessary mounting bracke to and base frames for :-
(a) Window type AC of any make capactiy 1.5 Ton cap.
(b) Water coolers of any make and cap 40 to 150 ltrs capacity.
(c) Split type AC of any make and capcity 1.5/2 ton.
(d) Deep freezers of any make & cap 200 to 425 ltrs capacity.
Supply and replace bottom tray of window type ACs 1.5/2.0 Ton capacity of any make complete all as specified and as directed by Engineer-in-Charge.
Supply and replace heavy duty PVC flexible pipe with necessary jubilee clamps for water cooler/split ACs/Window ACs drains of size :-
(a) 15mm dia bore.
(b) 20 mm dia bore.
S&F in replacement of PCB of split type AC Cap 1.5/ 2 TR as per existing make and model. Complete all as specified and directed by Engrs - in- charge.
M&L, for providing rubber foam heavy duty insulation tube over the existing copper tubing of any length at any location in replacement of worn out insulation including fixing with cable tie, clamping all as required at site, complete all as specified and directed by Engr-in-Charge.
S&F in replacement front grill of window type AC as per sample, complete all as specified and directed by Engr-in-Charge.
S&F, replacement to air filters of split type AC of 1.5/2.0 TR capacity as per existing pattern, complete all as specified and directed by Engr-in-Charge.
S&F in replacement new coling fan motor for window type AC1.5TR/2TR, complete all as specified and directed by Engr-in-Charge.
S&F in replacement new cooling fan motor for split type AC of 1.5/2.0 TR capacity, complete all as specified and directed by Engr-in-Charge.
Supply and fixing new chasis in replacement to worn out chasis of window type AC comprises of bottom cover new cooling coil, condenser coil, motor, blower,propeller fan capillary, filter, outer cover duly powder coated all as specified and as directed by Engineer-in-Charge.Make- Voltas/ LG
Supply and fixing indoor unit of split type AC 2 TR in replacement of worn out unit Comprises of cooling coil, blower, blower motor, swing motor,swing blade filter, PCB, Thermostate, complete all as specified and as directed by Engineer-in-charge. Make- Voltas/ LG
Supply and fixing in replacement to worn out door unit of split type AC of cap 2 TR. comprises of condensor, condenser motor, condensor fan and blade , capacitor, suction, discharge valve, outer cover duly powder coated all as specified and as directed by Engineer-in-Charge.Make-Voltas/ LG.
Supply & Fix in replacement MS stand factory made suitable for condensing unit of split type AC duly powder coated all as specified and as directed by Engineeer-in-Charge.
S&F in replacement Submersible PVC pump for desert cooler 230 volt single phase 50 HZ complete all as specified and directed by Engineer-in-Charge. Make : Khaitan/Universal or equivalent.
S&F in replacement of fan motor copper wound for desert cooler for operation on AC single phase 230 / 250 volts 50 HZ 1440 RPM complete all as specified and directed by Engineer-in-Charge. Make:- Khaitan/ Victor/ Americal/ Universal
Supply & replacement of wood wool pad ( Set of three) heavy duty for desert cooler complete all as directed by Engr-in-charge.
Supply & fixing in replacement of capacitor 4 mfd make Usha/Universal/Epcos
Supply & fixing in replacement desert cooler fan blades made of galvanised iron sheet of appropriate thickness as directed.
Supply & fixing in replacement of old rusted front panel with show grill of desert cooler with new grill made out of GI sheet 22 SWG complete with front show plate with ON/OFF switch for pump & four speed regulator for fan of approved make all as specified and as directed by Engr-in-Charge.
M&L for cleaning after taking down complete body including fitting and fixtures of desert coolers of capacity 4000/5000 cum/hours of any make with wire including removal of all sludge, loose paint dirt etc and preparationand cleaning of surface for painting and applying two coats of synthetic enamenl spray paint inside and outside surfaces and applying two coats rubber seal paint inside the water tank, and rewriting of MES No etc, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of 3 Pin Top, 5 Amp for desert coolers, complete all as specified and directed by Engr-in-Charge.
Taking down defective /unserviceable water cooler (capacity 40 ltrs) reciprocating compressor of make tecumseh/kirloskar/emerson , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuumed for dehydration complete all as specified and directed by Engr-in-Charge.
Taking down defective /unserviceable refrigarator (upto capacity 260 ltrs) compressor of make tecumseh/kirloskar/emerson , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuumed for dehydration complete all as specified and directed by Engr-in-Charge.
Taking down defective /unserviceable Refrigrator (upto capacity 320 ltrs) compressor of make tecumseh/kirloskar/emerson , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuumed for dehydration complete all as specified and directed by Engr-in-Charge.
Taking down defective /unserviceable Deep frizer (capacity upto 425 ltrs) compressor of make tecumseh/kirloskar/emerson , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuumed for dehydration complete all as specified and directed by Engr-in-Charge.
S&F in replacement of water tap for water cooler of capacity 40 Ltrs / 150 Ltrs, complete all as specified and directed by Engr-in-Charge.
M&L for checking the leakage by feeding dry Nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas R-12/22 for water cooler, complete all as specified and directed by Engr-in-Charge.
S & F in replacement of float valve assembly Complete suitable for water cooler of any size/cap Non metallic body complete all as specified and directed by Engr-in-Charge.Make:- Symet/prayag
Servicing of voltage stabilizers AC single phase 2 to 5 KVA of any make by opening of the body, cleaning of internaly, checking and tightening of all terminal connections including replacment of worn out terminal connectors, screws, bolts etc complete as directed by Engr-in-Charge.
S/F in replacement transformer of voltage stabilizer of capacity 5 KVA as per existing complete all as specified and as directed by engineer-in-Charge.
S/F in replacement to electronic control PCB of voltage stabilizer of capacity 5/4/3 KVA all as specified and as directed by Engineer-in-Charge.
S/F in replacement to timer circuit to voltage stabilizer of capacity 5/4/3 KVA all as specified and as directed by Engineer-in-Charge.
Minor repair of internal electrification work such as no electric supply, minor repair of electric fitting and fixture , switch , sockets , MCB,s etc at Mil Stn Gandhigham area round as directed. Note:- Replacement of faulty part not included in the above items .
Notes: - (i) Only Minor repair shall be carried out on spot and other major item shall be measured & paid separately. (ii) Major items replaced as "supply and fixing" under respective item of this schedule shall not be payable under this item.
Ramdev and Sons
SHOBHIT BUILDERS
Ell Ess Contractor
Ahmed B Khatri
NILESH SUBHASH KARALE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .