| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 CrAccepted-AOC | ₹2.7 Cr Quoted ₹2.8 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹3.5 CrRejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON W MUMBAI 400 104 | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹3.5 Cr | L2 | Rejected-Finance NOT LOWEST BIDDER |
| 3 | L3₹3.9 CrRejected-Finance | ₹3.9 Cr | L3 | Rejected-Finance NOT LOWEST BIDDER |
| 4 | L4₹4.1 CrRejected-Finance | ₹4.1 Cr | L4 | Rejected-Finance NOT LOWEST BIDDER |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not recommended as per note 1 of appx A to NIT. The contractor is enlisted in E class ie three class below the eligible criteria |
| Sl No | Description | Qty | Unit | Pneumatic Engineers Pvt. Ltd. L4 | Shree Ayyappa Engineering L2 | BRITE INDUSTRIES L3 | Superior Aircon Pvt. Ltd. L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing and commissioning of Loft/ ceiling mounted Air Handling unit (CSU) of capacity 3.0 TR, having following technical specifications complete all as specified and as directed by Engineer-in-Charge:-
(i) 1200 CFM Capacity (ii) Outer & Inner skin both 0.6 mm Pre-coated GI (iii) Thicknes of Insulated Panels 25/45mm thick CFC Free PUF injected (Density: 40 Kg/ Cum) (iv) Material of Drain Pan, 20 Gauge, SS-304 Tray duly insulated with 13 mm closed cell Nitrile insulation (v) Material of Sump - 18 Gauge, SS-304 (vi) Chilled water/ Hot water Coil :- Copper Tube, GI Casing, tube dia 12.70 mm/ 1/2" Outer dia, Tube Thickness 27 nSWG/ 0.41 mm, Header material MS, Fins Thickness 0.15 mm, Fins material Plain Aluminium, No of Fin per Inch (FPI) (Chilled water)- 11/12 Nos, No of Fin per Inch (FPI) (Hot Water)- 08/10 Nos (vii) Filters are synthetic (non-woven type), efficiency of Pre filter (EU-4) - 90% to 10 microne, efficiency of fine filter (EU-5) - 90% to 05 microne (viii) Blower of dia 225mm RPM-3130, Shaft pully system, flame proof blower induction motor of 1.5 HP, motor pole 2 (for belt driven), pad of 2.4 sq ft., eliminator of 2.4 Sq ft., heating and cooling coil each of 2.4 Sq ft., filters of 2.0 Sq ft., dimension of CSU L x W x H is 2.75 x 0.93 x 0.95m, pump for 200mm pad 0.25 HP and panel thickness 25mm Model ZDS-12 also included connected cables for CSU. | 40 | Each | 1,60,000 ₹64 L | 1,86,300 ₹74.5 L | 2,39,071 ₹95.6 L | 1,50,000 ₹60 L |
| 2.00 | Supply, installation, testing and commissioning of Air Handling unit (AHU) of capacity 25.0 TR having following technical specifications complete all as specified and as directed by Engineer-in-Charge:-
(i) 10000 CFM Capacity (ii) Outer & Inner skin both 0.6 mm Pre-coated GI (iii) Thickness of Insulated Panels 25/45mm thick CFC Free PUF injected (Density: 40 kg/Cum) (iv) Material of Drain Pan, 20 Gauge, SS-304 Tray duly insulated with 13 mm closed cell Nitrile insulation (v) Material of Sump - 18 Gauge, SS-304 (vi) Chilled water/ Hot water Coil:- Copper tube, GI Casing, tube dia 12.70 mm/ 1/2" Outer Dia. Tube thickness 27.0 nSWG/ 0.41 mm, Header material MS, Fins thickness 0.15 mm, Fins Material Plain Aluminium, No of Fin per Inch (FPI) (Chilled water) -11/12 Nos, No of Fin per Inch (FPI) (Hot water) -08/10 Nos (vii) Filters are synthetic (non-woven type), efficiency of Pre filter (EU- 4) - 90% to 10 microne, efficiency of fine filter (EU-5) - 90% to 05 microne (viii) Blower of dia 560mm RPM-1299, Shaft pully system, flame proof blower induction motor of 7.5 HP, motor pole 4 (for belt driven), cooling coil RD 6, heating coil RD 2, pad area 20 Sq ft., eliminator area of 20 Sq ft., heating and cooling coil each of 20 Sq ft., filters of 20 Sq ft., dimension of AHU L x W x H is 4.5 x 1.85 x 2.62m, pump for 200mm pad 0.5 HP and panel thickness 45mm Model ZDS-100 also included connected cables for AHU. | 2 | Each | 8,00,000 ₹16 L | 6,25,700 ₹12.5 L | 7,41,776 ₹14.8 L | 8,00,000 ₹16 L |
| 3.00 | Supply, installation, testing and commissioning of Air Handling unit (AHU) of capacity 35.0 TR having following technical specifications complete all as specified and directed by Engr-in-Charge:-
(i) 14000 CFM Capacity (ii) Outer & Inner skin both 0.6 mm Pre-coated GI (iii) Thickness of Insulated Panels 25/45 mm thick CFC Free PUF injected (Density: 40 kg/Cum) (iv) Material of Drain Pan, 20 Gauge, SS-304 Tray duly insulated with 13 mm closed cell Nitrile insulation (v) Material of Sump - 18 Gauge, SS-304 (vi) Chilled water/ Hot water Coil:- Copper tube, GI Casing, tube dia 12.70 mm/ 1/2" Outer Dia. Tube thickness 27.0 nSWG/ 0.41 mm, Header material MS, Fins thickness 0.15 mm, Fins Material Plain Aluminium, No of Fin per Inch (FPI) (Chilled water) -11/12 Nos, No of Fin per Inch (FPI) (Hot water) -08/10 Nos
(vii) Filters are synthetic (non-woven type), efficiency of Pre filter (EU- 4) - 90% to 10 microne, efficiency of fine filter (EU-5) - 90% to 05 microne
(viii) Blower of dia 710mm RPM-986, Shaft pully system, flame proof blower induction motor of 10 HP, motor pole 4 (for belt driven), cooling coil RD 6, heating coil RD 2, pad area 28 Sq ft., eliminator area of 28 Sq ft., heating and cooling coil area each of 28 Sq ft., filters of 28 Sq ft., dimension of CSU L x W x H is 4.41 x 2.15 x 1.86m, pump for 200mm pad 1.0 HP and panel thickness 45mm Model ZDS-140 also included connected cables for AHU. | 4 | Each | 10,00,000 ₹40 L | 9,09,060 ₹36.4 L | 10,22,399 ₹40.9 L | 11,00,000 ₹44 L |
| 4.00 | Supply, installation, testing and commissioning of Hot Water Generator with following technical specifications:-
(i) 45 KW capacity (ii) Vertical type, 5 KW x 03 Nos x 3 Steps = 45 KW
(iii) Water flow rate 129 Ltr per min (iv) Tempreture Inlet 45 Degree, Outlet 50 Degree (v) Working Pressure 100 PSI, Weight 270 Kg (vi) Water Holding capacity 59 Ltr (vii) Vessel Size 12 inch Dia, Vassel Material- Mild steel, Vassel sheet thickness 6 mm Shell, Panel Sheet Thickness 1.6 mm (viii) Heater is Electric Immersion (Water Resistance), Material of Heater Tube Seamless copper pipe (ix) Test Pressure 250 PSI, Insulation Material Resin bonded fiber glass wool 50 mm Thickness (x) Material Of Cladding Aluminium Sheet 0.63 mm Thickness (xi) Unit Dimension (L x W x H) 31 inch x 21 inch x 43 inch. (Make:- Emerald/ KEPL/ Rapid Cool) | 4 | Each | 1,60,000 ₹6.4 L | 1,47,800 ₹5.9 L | 7,72,156.7 ₹30.9 L | 1,00,000 ₹4 L |
| 5.00 | Taking up or taking down existing 20 mm bore steel tubing and connections complete all as specified and directed. | 290 | RUNNING METRE | 280 ₹81,200 | 50 ₹14,500 | 28 ₹8,120 | 200 ₹58,000 |
| 6.00 | All as per item No.5 above but of size 25 mm bore | 850 | RUNNING METRE | 350 ₹3.0 L | 50 ₹42,500 | 28 ₹23,800 | 250 ₹2.1 L |
| 7.00 | All as per item No.5 above but of size 32mm bore | 40 | RUNNING METRE | 450 ₹18,000 | 50 ₹2,000 | 28 ₹1,120 | 300 ₹12,000 |
| 8.00 | All as per item No.5 above but of size 40 mm bore | 35 | RUNNING METRE | 575 ₹20,125 | 50 ₹1,750 | 28 ₹980 | 350 ₹12,250 |
| 9.00 | All as per item No.5 above but of size 50 mm bore | 180 | RUNNING METRE | 750 ₹1.4 L | 100 ₹18,000 | 28 ₹5,040 | 400 ₹72,000 |
| 10.00 | All as per item No.5 above but of size 80 mm bore | 380 | RUNNING METRE | 1,150 ₹4.4 L | 100 ₹38,000 | 28 ₹10,640 | 450 ₹1.7 L |
Updated dates
Tender Value
₹2.1 Cr
EMD Value
₹2.9 L
Closing Date
27 Mar 2026, 6:00 pmClosed
CWE (AF) BHUJ
CWE (AF) BHUJ KHAVDA ROAD BHUJ KACHCHH PIN 370001
ADDN/ALTN TO CERTAIN INFRASTRUCTURE (CENTRAL AIRCONDITIONING) AT AF STN NALIYA
2025_MES_715203_1
85289/E8
Open Tender
Electrical and Maintenance Works
180 days
NALIYA
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,000
GE (AF) NALIYA
₹2.9 L
Yes
5 Jun 2026
18 Jun 2025
30 Mar 2026
18 Feb 2026
27 Mar 2026
2 Mar 2026
(viii) Blower of dia 225 mm RPM- 3130, Shaft pully system, Flame proof blower induction motor of 1.5 HP, Motor pole 2 (for belt driven), Pad of 2.4 Sq Ft, Eliminator of 2.4 Sq Ft, Heating and Cooling Coil each of 2.4 Sq Ft, Filters of 2.0 Sq Ft, Dimension of CSU LXWXH is 2.75x0.93x0.95 m, Pump for 200 mm Pad 0.25 HP and Panel thickness 25 mm Model ZDS-12 also included connected cables for CSU complete all as specified and directed by Engr-in-Charge.
(3) Pre-Filter having dust filtration capacity 90% efficiency down to 10 microns (synthetic non woven., fire retardant type supported with aluminium & HDPE mush & generally conforming to EU-4 & EU-779 specification) (4) Micro Vee filter having dust proof filtration capacity to 5 micron conforming to EU-7 specifications magne helic gauges be provided to read pressure drop across filter bank. (5) Fan Section fitted with statically & dynamically balanced forward curved blower fan DIDW type suitable to requisite static pressure with belt driven squirrel cage induction motor TEFC 415 V 3 phase 7.5 Hp 50 Hz AC supply insulation 'F Class. The motor shall be energy efficient confirming to IS 12615. Note:- The cost quoted by the contractor includes all above all above (except butterfly valves, Y Strainers, 3 Way Valves & Chilled water pipeline which will be paid separately. However the connection dovetailing, testing & commissioning of AHU as a whole is included in the rate quoted for AHU.
(3)Pre-Filter having dust filtration capacity 90% efficiency down to 10 microns (synthetic non woven, fire retardant type supported with aluminium & HDPE mush & generally conforming to EU-4 & EU-779 specification). (4) Micro Vee filter having dust proof filtration capacity to 5 micron conforming to EU-7 specifications magne helic gauges be provided to read pressure drop across filter bank. (5) Fan Section fitted with statically & dynamically balanced forward curved blower fan DIDW type suitable to requisite static pressure with belt driven squirrel cage induction motor TEFC 415 V 3 phase 7.5 Hp 50 Hz AC supply insulation 'F Class. The motor shall be energy efficient confirming to IS 12615. Note:- The cost quoted by the contractor includes all above all above (except butterfly valves, Y Strainers ,3 Way Valves & Chilled water pipeline which will be paid separately . However the connection dovetailing, testing & commissioning of AHU as a whole is included in the rate quoted for AHU.
S & F in repairs 20mm bore galvanised tubes, 'medium grade', with all fitting and fixed complete to walls and ceilings or laid in floors including taking up or down steel tubing and connections, including cleaning for refixing or removal to store.
All as per item No.4 above but 25mm bore
All as per item No.4 above but 32mm bore
All as per item No.4 above but 50mm bore
All as per item No.4 above but 80mm bore
All as per item No.4 above but 100mm bore
M & L for 20mm bore Hot and cold water pipe lines outside the building all along the wall/roof (with necessary fittings, clamps and vibration isolators but excluding valves/strainers/pressure gauges) adequately supported on rigid supports and duly insulated with pipe sections of Fire retardant quality expanded polystyrene molded pipe section of density 36 Kg per cum and thickness 50 mm ,applied after a thick coat of cold setting adhesive (CRPX compound) rapping with a layer of 120 gm/Sqm polythene faced hessian cloth sheet (vapor barrier seal) (FR grade) and secured with 0.50 mm AL sheet cladding complete with type 3 grade 1 roofing felt strip (as per IS:1322)at the joints and repairing of damage to the building if any as per specifications and as required complete in all respects.
All as per item No.25 Above but 25mm bore
All as per item No.25 Above but 32mm bore
All as per item No.25 Above but 50mm bore
All as per item No.25 Above but 80mm bore
All as per item No.25 Above but 100mm bore
M & L for Aluminium cladding on resin bonded fiber glass wool surface with 22 gauge flame proof Aluminium sheet with all required misc items complete all as specified and directed by Engr-in-Charge.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
85289TENDERDOC.rar
Tender Documents • 26.63 MB
BOQ_800758.xls
BOQ • 2.80 MB