Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹23.0 Laccepted-aoc | ₹23.0 L | accepted-aoc |
Tender Value
₹23.1 L
EMD Value
₹23,064
Closing Date
1 Jun 2026, 5:00 pmClosed
Executive Engineer RPR Division Kandukur
Kandukur
Improvements and strengthening to spillway gates of Rallapadu Project in Lingasamudram Mandal of Prakasam district
937038
TO NO-02/25-26
OPEN - NCB
Civil Engineering Works
SRI POTTI SRI RAMULU NELLORE
4 documents required · 4 mandatory
₹817
₹23,064
16 Jun 2026
25 May 2026
25 May 2026
Supply of Engine Oil for Generators to operate spillway gates as directed by the Engineer-in-Charge
Supply of Cadmium compound as directed by the Engineer-in-Charge
Supply of HSD Oil for Generators to operate spillway gates as directed by the Engineer-in-Charge
Supply of Petrol for consumption of power saw and grass cutter for removal of weeds and shrubs
Supply of Grease to apply for bearings in hoist equipment, trunions and rope drums of additional spillway. as directed by the Engineer-in-Charge
Supply of Electrician for Operation and maintenance of Radial gates, verticle gates, Generators etc., as directed by the Engineer-in-Charge
Supply of Fitter for Operation and maintenance of Radial gates, verticle gates, Generators etc., as directed by the Engineer-in-Charge
Supply of Watchman (Man mazdoor) for the day and night watch and ward of of Radial gates, verticle gates, Generators etc., as directed by the Engineer-in-Charge
Supply and transportation of .45V LED Street light Luminaire made of pressure diecast aluminum body with powder coated as directed by the Engineer-in-Charge
Supply of 160A 4 Pole MCCB, adjustable, confirms to IEC 60947-2 and IS 13947-Part 1 & 2, having Breaking Capacity 25KA with thermal magnetic release Panel Mounted. as directed by the Engineer-in-Charge
Supply of 10.0 Sq mm. ISI marked FRLS/ FRLS-H / HFFR / ZHFR PVC insulated flexible copper cables 1100V grade as per IS: 694/1990 & IS:17048/2018 specification for copper cable.. as directed by the Engineer-in-Charge
Supply and fixing of CT operated direct reading type Ammeter (Analog type (96 mm x 96 mm) Below 500 A) on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.. as directed by the Engineer-in-Charge
Supply and fixing of (0-500) V range Voltmeter Analog type (96 mm x 96 mm) on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.. as directed by the Engineer-in-Charge
Supply of 200A ISI marked 4 Pole Change Over Switch on Load with open Execution as per IS:13947 as directed by the Engineer-in-Charge
Supply of 200A, 415V. Porcelain Rewireable Fuse Units with extension strip. as directed by the Engineer-in-Charge
Supply of Cable root Indicators of size 152mm round / 102mm x 102mm /152mm x 152mm as directed by the Engineer-in-Charge
Supply of Push type button motor starter for A.C Units. as directed by the Engineer-in-Charge
Supply of 2.50 Sq mm. ISI marked FRLS/ FRLS-H / HFFR / ZHFR PVC insulated flexible copper cables 1100V grade as per IS: 694/1990 & IS:17048/2018 specification for copper cable.. as directed by the Engineer-in-Charge
Supply of 1.50 Sq mm. ISI marked FRLS/ FRLS-H / HFFR / ZHFR PVC insulated flexible copper cables 1100V grade as per IS: 694/1990 & IS:17048/2018 specification for copper cable.. as directed by the Engineer-in-Charge
Supply of PVC /cotton tape Role (8 Mtrs). as directed by the Engineer-in-Charge
Supply, fixing and commisioning of gate position indicators for gates of additional spillway of Rallapadu reservoir including cost of materials, labour, machinery etc., complete for finished item of work. As directed by the Engineer -in-Charge
Overhauling and lubrication to the roller cages on both sides the Spillway and Scour sluice gates and ropes of Radial gates including cost of material, labour, machinary etc complete as directed by the Engineer-in-Charge
Cleaning and lubrication to the gates chains on both sides of gates including cost and conveyance of all material, labour etc complete as directed by the Engineer-in-Charge
Cleaning of dry lubricants and lubrication to the Gear Wheel, Pinion bearings etc for Hoist equipment,repairs to sump including cost and conveyance of all material, labour complete as directed by the Engineer-in-Charge
Cleaning of dry lubricants and lubrication to the Gear Wheel, Pinion bearings etc for Hoist equipment for additional spillway including cost and conveyance of all material, labour complete as directed by the Engineer-in-Charge
Fabrication, supply and errection of line shaft flange couplings including cost of materials, labour, machinery, aligning and commisioning complete on hoist platform of radial gates of additional spillway as directed by the Engineer-in-Charge
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
BOQ Kothapeta (1).xlsx
TENDER_DOCUMENT • 0.01 MB
T.Agt.Conditions 26-27.docx
TENDER_DOCUMENT • 0.09 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .