| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.1 CrAccepted-AOC | ₹4.1 Cr Quoted ₹4.3 Cr | L1 | Accepted-AOC L1 |
| Sl No | Description | Qty | Unit | M/S ROY ENTERPRISE L1 |
|---|---|---|---|---|
| 0.00CIVIL WORK : | ||||
| 1.00 | Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed. | 200 | sqm | 20 ₹4,000 Lowest |
| 2.00Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. | ||||
| 2.01 | (a) Depth of excavation not exceeding 1,500 mm. | 265 | cum | 120 ₹31,800 Lowest |
| 2.02 | (b) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring
shoring. | 50 | cum | 209 ₹10,450 Lowest |
| 3.00Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) | ||||
| 3.01 | (a) With earth obtained from excavation of foundation. | 150 | cum | 84 ₹12,600 Lowest |
| 3.02 | (b) With carried earth arranged by the contractor within a radius of 1 km. including cost of carried earth. | 30 | cum | 340 ₹10,200 Lowest |
| 4.00 | Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with
water, ramming complete including the cost of supply of sand.(payment to be made on measurement of finished quantity) By Fine Sand | 55 | cum | 1,435 ₹78,925 Lowest |
| 5.00Hire and labour charges for shoring work (including necessary close plank walling, framing, Eucalyptus/Jhou bulla piling, strutting etc) complete as per direction of the Engineer-in-charge for foundation excavation (vertical surface area in contact with supported earth is to be measured.) (This item should be executed on specific direction of the Enginner in charge). | ||||
Tender Value
Refer Docs
EMD Value
₹5 L
Closing Date
23 Jul 2025, 11:00 amClosed
Sudhir Kumar Ambashta, Chief Engineer
3rd Floor Block A, EMD, Vidyut Bhavan, Salt Lake
Renovation and Modernization of Area Load Despatch Center of WBSEDCL at Salt Lake, Kolkata (Package-1 Civil, PHE, Electrical, AC and Firefighting and FDA System)
2025_WBSED_855312_1
CE / EMD / 2025-26 / e-tender / 14
Open Tender
Support/Maintenance Service
Item Wise
300 days
Area Load Despatch Center of WBSEDCL at Salt Lake
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹5 L
3rd Floor Block A, EMD, Vidyut Bhavan, Salt Lake
30 Oct 2025
29 May 2025
25 Jul 2025
10 Jun 2025
23 Jul 2025
18 Jun 2025
16 Jun 2025
Amount
CIVIL WORK :
Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed.
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.
(a) Depth of excavation not exceeding 1,500 mm.
(b) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring.
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)
(a) With earth obtained from excavation of foundation.
(b) With carried earth arranged by the contractor within a radius of 1 km. including cost of carried earth.
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand.(payment to be made on measurement of finished quantity) By Fine Sand
Hire and labour charges for shoring work (including necessary close plank walling, framing, Eucalyptus/Jhou bulla piling, strutting etc) complete as per direction of the Engineer-in-charge for foundation excavation (vertical surface area in contact with supported earth is to be measured.) (This item should be executed on specific direction of the Enginner in charge).
(a) Depth upto 1.5 m.
(b) For additional depth beyond 1.5 m. and upto 3.00 m
Bailing or pumping out water from foundation trenches. This item should be executed on the specific direction of the Engineer-in-charges when he is satisfied in his absolute discretion, that this has not been necessitated due to any fault on the part of the contractor (Payment, if permitted, will be made on the quantity of water calculated on the basis of initial and final water calculated on the basis of initial and final water level measured before starting and completion of each days work which necessitates a bailing / pumping of water from the trench. The final level of water to be measured, will depend on the level at which the day's work will be taken up. The rate includes any seepage water that may percolate in the trench during pumping)
Post Constructional Measures : (a) Anti-termite treatment to the outside of foundations with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1%concentration) with water by weight including cutting shallow channel by excavating soil along and close to the wall face ensuring uniform dispersal of the chemical emulsion to a depth of 300mm. from the ground level by rodding with 12mm. dia. M.S. rod at 150mm.interval in the channel. 1.75 litres of chemical emulsion per metre length shall be used and a balance quantity of 0.5 litres of the chemical emulsion per running metre shall then be used to treat the back fill earth by directing the spray of the imulsion towards the wall surface. The entire work is to be carried out as per specification laid down in para 4.3.1.1 of code IS-6313 (Part-III) 1981.
(c) Anti-termite treatment to the soil under floor with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with water by weight including drilling vertically 12mm. dia holes at the junction of floor and wall at 300mm. interval to reach the soil below using hand operated pressure pump to squirt chemical emulsion into the pump to squirt chemical emulsion into the holes at the rate of one litre per hole. The holes shall be sealed after operation to match with the existing floor. The entire work is to be carried out as per specification laid down in para 4.3.1.4 of code I.S.-6313 (Part-III)- 1981.
d) Anti-termite treatment to the junction of wood work and masonry walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight including spraying at the points of contact with the adjoining masonry by drilling 6m. dia holes at a downward angle of about 45 degree at the junction of woodwork and masonry and squirting chemical emulsion into these holes at the rate of half litre per hole. The entire work is to be carried out as per specification of Code I.S.-6313 (Part-III)-1981. The shutters are to be sprayed with emulsion. on both sides. All wooden fixtures like almirahs, racks etc. are also to be throughly sprayed with chemical emulsion. (Payment will be made on the basis of outside measurements of doors and windows)
Spot application for insecticides using Aqua base spray for pest (for bugs, cockroaches, silverfish, spider, termites, mosquitoes) to walls and ceiling etc. with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight including spraying the emulsified chemical @ 0.5 litres per sq.m. by a hand operated pressure pump on wall surfaces, ceiling, electrical fixture,electrical lines including drilling holes in?places where source of termite is detected squirting chemical solution into the holes and sealing the holes with cement grout. (Rate is per sq.m. of the floor area while actual work will be all walls ceiling, rack, partition and furniture).
Cutting chase upto 125 x 150 mm. and subsequent mending of damages.
(a) in brick wall [Cement-3.6 Kg/Mtr]
(b) in concrete wall [Cement-3.6 Kg/Mtr
Cutting holes and subsequent mending good damages. (a) Diameter upto 150 mm.
(i) In brick work [Cement-4.0 Kg/Mtr]
(ii) In concrete work (plain or R.C.) [Cement- 3.0 Kg/Mtr]
Cutting holes and subsequent mending good damages. (b) Diameter exceeding 150 mm. but not exceeding 300 mm In brick work [Cement-6.0 Kg/Mtr]
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Labour for laying single brick flat soling including ramming and dressing bed to proper level and filling joints with powdered earth.
Supplying and laying brick Khoa of ordinary bats of size (38 mmx 63 mm)of approved quality in 100 mm layer (loose) filling in gaps with small ones rammed and compact as directed true to level and grade.
Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed.
Cleaning the concrete surface by removing dirt and debris, marking defective locations and removing loose concrete by careful stripping untill hard surface is exposed, cutting the concrete to regular shape, wire brushing the exposed surface and removing debris from site complete as per direction of the Engineer - in - Charge.
Cleaning the exposed reinforcement preferably upto full diameter by wire brush, applying two coats of polymer based rust removing compound left for 24 hours, removing the coating and then applying two (2) coats of polymer modified anti corrosive protective coating formulated to inhibit the corrosion of reinforcement as per manufacturer's pecification]
Removing corroded worn out portion of reinforcement (when the area of bar is damaged by more than 25%) by cutting and replacing the same by a new plain round bar of requisite diameter by binding with required lap / welding with old bar, including cost of reinforcement, complete in all respect including removing unserviceable materials from site as per direction of the Engineer - in - charge. Note : Payment on weight (Kg.) of new reinforcement.
Applying epoxy based reactive joining agent for joining the old concrete with fresh concrete to be applied within manufacturer's specified time as per manufacturers specification. (0.4 Kg / m² of concrete surface).
Extra rate for adding Polyester Fibre anti shrinkage material @ 0.25% by weight of cement [or as per Manufacturer's Specification] as secondary reinforcement to arrest hair crack in concrete including cost of Fibre .
Extra rate for using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturer's specified rate) for concrete of various grades.
Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer's specification for water proofing layer in water tank etc. including cost of cement and water proofing agent) in all floors
Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification.
Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars.
Ground Floor.
1st Floor
2nd Floor
Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m.
Ground Floor.
1st Floor
2nd Floor
Dismantling all types of masonry except cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.
Ground Floor.
1st Floor
2nd Floor
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m
(a) upto 150 mm. thick
Ground Floor.
1st Floor
2nd Floor
(b) above 150 mm. thick
Ground Floor.
1st Floor
2nd Floor
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer- in-charge.
Dismantling tiles in floor,walls and roofs laid in cement mortar including stacking materials within 50m lead for thickness of tiles 10 mm to 25mm
Repairing crack in wall by cement grouting (1 : 2) including widening the crack on the surface (into V section) cleaning and packing the same with cement mortar (1 : 2) and finishing off to match with adjacent surface
Stitching crack in brick wall by carefully cutting out face brick 125 mm. deep into the wall, cleaning the gap and filling up the same with precast cement concrete block carefully set in cement mortar (1:3) including mending good damages and finishing the surface to match with adjacent areas complete as per direction. (i) With plain cement concrete blocks(1:1½:3) with stone chips. (a) Block size 250 x 125 x 75 mm. (Cement-1.85 Kg/No.)
Roof treatment by application of non toxic polyurethane modified acrylic based single component (P U Roof Coat) solvent free, cold applied polyurethane modified elastomeric waterproofing membrane with excellant UV resistant capacity as per ASTM D 6083 (a water based 100%acrylic elastomeric emulsion polymer latex coating used as protective coating for roofs) after preparing the surface by cleaning and repairing the roof cracks by cement & sand mortar (1:4), preferably with antishrinkage mortar (to be paid separately) if any, apply two coats along with a Primingcoat(two coats of P U Roof Coat and one coat of primer coat compatible with main product as per manufacturers specification) and reinforced with or without 20 gsm GeotextileFleece, including the cost of primer coat and basepreparation, tools & Plants but excluding the cost of scaffolding and stagging complete as per direction of Engineer -in-charge. (Note: If Geotextile Fleece not used ,the rate would be reduced by Rs. 5/-per Sqm
6 mm plaster on cement concrete or reinforced cement concrete work with white cement based polymer modified self curing & anti shrinkage mortar of approved make as per the direction of Engineer-In-Charge.
Supplying and application of chemical for post Installed rebar connection by using ETA approved for seismic criteria In rebar connection, Including drilling hole to the required depth by rotary hammer drill, cleaning with brush & jet of clean air,Drilling chemical using serrated noule to eliminate mixing error and in a voidless manner IncludIng charges for all tools & plants. Application to be designed for post Installed rebars as per EC2/TR023 or relevant tested and accepted design guidelines and the design document to be furnished by the manufacturer. The chemical should have ETA approval for seismic criteria . The installation and setting strictly followed by the Superintending Engineer of the respective circle and injection process should be and the setting instructions should be strictly followed as per manufacturer's specifications as approved by EIC prior to drilling along with post· Installed rebar embedment design report. The existing concrete member should be scanned using rebar scanner to avoid hitting existing reinforcement in concrete during drilling.
Notes Rebar grouting Is specifically required for extension and strengthening purpose of old or existing RCCstructural members with new RCCstructural members through rebar fixing chemical Item without breaking beam, coloumn, roof slab, lintel, ceiling etc.
i) Cost of post installed rebaring application with chemical as specified for 8 mm dia per cm of depth
ii) Cost of post installed rebaring application with chemical as specified for 10 mm dia per cm of depth
iii) Cost of post installed rebaring application with chemical as specified for 12 mm dia per cm of depth
iv) Cost of post installed rebaring application with chemical as specified for 16 mm dia per cm of depth
Providing and fixing Scaffolding net of required width made of high density Polyethylene UV stabilized knitted on warp knitting machines having density 100 grams/sqm and shading coefficient minimum 75% around the construction site/ for vertical extension as per requirement including fastening/tying with building/scaffolding pipes or with any other fixtures etc. complete as per direction of Engineer-in-Charge. (One time payment shall be made for providing Scaffolding net from start of work till completion of work including shifting if any. The Scaffolding net shall be the property of the contractor on completion of the work)
Supplying ready mixed concrete of M 25 Grade with well graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu.m of wet concrete produced in computerised batching plant under controlled condition using approved super plastisizer, designing concrete mix following I.S. 10262 and I.S. 456, transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required levels of concreting and then placing the mix in its final location of form work, compacting and curing the same complete as per specification & direction of the Engineer-in-charge including computerised batching plant transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete including cost of hire charge of platform and its supporting staging which would be paid through separate item. [cement to be supplied by the Manufacturer/ supplier] With approved concrete pump At
i) Ground Floor.
ii) First Floor
iii) second Floor
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, as per relevant IS codes. Pakur Variety.
Ground Floor.
1st Floor
Polymer concrete made with water resistant bonding agent of synthetic rubber emulsion as per manufacturer's specification including the cost of cement concrete (2.75 Kg / bag of cement)
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction in foundation and in any floor. Tor steel/Mild steel JSW/JSPL/Shyam/SRMB/BMASL/Electro Steel/SSL
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, as per relevant IS codes. a) Pakur Variety
Ground Floor.
1st Floor
Cement concrete with graded jhama khoa (30 mm size) excluding shuttering. (a) 1:3:6 proportion
i) Ground Floor and foundation.
ii) First Floor
iii) second Floor
Cement concrete with graded stone ballast (40 mm size excluding shuttering) (A) [Pakur Variety] (a) 1:3:6 proportion
i) Ground Floor.
ii) First Floor
iii) second Floor
Brick work with 1st class bricks in cement mortar (1:6)
In Foundation & Plinth
In superstructure
i) Ground Floor.
ii) First Floor
iii) Second Floor
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in
i) Ground Floor.
ii) First Floor
iii) Second Floor
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (a) 25 mm to 30 mm thick wooden shuttering. as per decision & direction of Engineer-In-Charge.
i) Ground Floor.
ii) First Floor
iii) Second Floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary. a) With 1:4 cement mortar 20 mm thick plaster.
Ground Floor.
1st Floor
2nd floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary. a) With 1:6 cement mortar (15 mm) thick plaster.
Ground Floor.
1st Floor.
2nd Floor.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary.(ii) With 1:4 cement mortar(c) 10 mm thick plaster (internal ceiling)
i) Ground floor
ii) First Floor
iii) Second Floor
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc.
Scraping of moss, blisters etc.thoroughly from exterior surface of walls necessitating the use of scraper, wire brush etc.(Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge)
Removing old scales, blisters etc. of interior surface of walls,ceiling by scraping etc. and preparing smooth and even surface with rendering or cement mortar (1:2) (as necessary), to make the surface suitable for receiving distemper. (Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge).
Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) in any floor
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. The rate includes cost of material, labour, scaffolding and all incidental charges(a) One Coat.
Ground Floor.
1st Floor.
2nd floor
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. a) Super Protective 100% Acrylic Emulsion. Two Coat.
Ground Floor.
1st Floor.
2nd floor
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or concrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC.Two Coats Water based interior grade Acrylic Primer in all floors
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) ii) Luxury Quality in all floors
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.in all floors
Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc in all floors
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary (a) On timber or plastered surface : Two coats (with any shade except white) in all floors
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary. a) On steel or other metal surface With super gloss (hi-gloss) - Two Coats (with any shade except white). in all floors
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge.
Cleaning and removing conservancy garbage mixed with rubbish & other filthy materials from the road side flank, drain and compound including sutting, loading, unloading to and from truck or cart by Mathor labour & removing the same to any distance.
Polishing only of old marble or terrazo work with oxalic acid powder using 33 gms/ sq.m. by manual labour / machine where necessary.
Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mm thickness in floor, lobby, stair, landing & treads etc. over 20 mm (av.) thck base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/Sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/Sq.m with necessary pigments including grinding and Granite polishing as per direction of Engineering -in -Charge in Ground Floor. {White cement and Pigment to be supplied by the Agency With Makrana plain pink / Adranga Pink / Garbh Gulabi / Udaypur pink / Udaypur Green / Black Bhaslana Area of each Slab/tile exceeding 0.60 sq.m but not exceeding 1.00 sq.m.
Ground Floor.
1st Floor.
Supplying, fitting, fixing marble slab/tiles, 15 mm. to 18 mm. thick in dado / wall in 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks applying white cement slurry @ 4.4 kg/ sq.m at the back side of marble & pointing in cement mortar (1:2) (1 cement, 2 marble dust) with admixture of pigment matching the stone shades including polishing all complete as per direction of the Engineer-in-charge including cost of materials, labours, scaffolding, staging, curing complete. [White cement, Pigment, brass / copper hooks to be supplied by the Agency] (a) With Makrana plain pink / Adranga Pink / Garbh Gulabi / Udaypur Pink / Udaypur green / Black Bhalsana Area of each slab/tile exceeding 0.6 sq.m but not excedding 1 sq.m.
Ground Floor.
1st Floor.
2nd floor
Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. Area of each Granite slab 0.6 to 1.0 Square meter
Ground Floor.
1st Floor.
Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia,rise etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete. [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] (b) Area of each Granite slab above 1.00 Square meter
Ground Floor.
1st Floor.
Supplying, fitting & fixing 1st quality Ceramic tiles in floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (A) Floor With Polymerised Adhesive and Epoxy grout pointing including spacer- 2 mm ( When Tiles are laid over existing hard ready surface) Area of each tile upto 0.09 Sq.m [using adhesive 3 mm thick] (i) Coloured decorative
Ground Floor.
1st Floor.
Supplying, fitting & fixing 1st quality Ceramic tiles in walls to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(D) Wall With Polymerised Adhesive & Epoxy grout pointing With Polymerised Adhesive and Epoxy grout pointing including spacer- 2 mm ( When Tiles are laid over existing hard ready surface) (a) Area of each tile upto 0.09 Sq.m [using adhesive 3 mm thick] (i) Coloured decorative
Ground Floor.
1st Floor.
Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr's hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor).: Sizes-600 mm x600mm x10 mm with breaking strength > 1500 N
Ground Floor.
1st Floor.
Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile. In any floors
Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In wall/dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile.In any floors.
18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m] at wall
18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m] at dado wall
Extra cost of labour for prefinished and premoulded Nosing to treads of steps, railing, window sill etc. of Kota Stone/marble/granite etc. as per direction of EIC
Supplying, fitting and fixing Black Stone slab used in Kitchen slab, alcove, wardrobe etc. laid and jointed with necessary adhesive Cement mortar (1:2) including grinding or polishing as per direction of Engineer-in -Charge (b) Slab Thickness above 25 mm and upto 37.5 mm Ground floor
Supplying & laying of approved make and brand of scratch proof, flexible & homogeneous P.V.C. Vinyle flooring conforming to IS:3462 - 1982 in required finish, fixed with synthetic acrylic adhesive after preparing the floor, levelling & smothaning when necessary with suitable putty, as per the design & instruction of the Engineer-in-charge.(i) 2 mm thick (Plain)
Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.|. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting of:
(a) Providing at required spacing to form modular framework, pedestals made out of GI tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on to the G.I. Base plate of size 100 mm x 100 mm x 3 mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3.5 mm welded with GI fully threaded stud 16 mm outer diameter with two GI Check nuts screwed on the stud for level adjustment upto 50mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug.
(b) Stringers system in all steel construction hot dipped galvanized of rectangular size 570x20x30x0.80 mm thick having holes at both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as per the architectural drawings, as specified and as directed by the Engineer-in-charge.
(c) Providing and fixing Access Floor panel of 600x600x32 mm medium grade Filled Stee! anti static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Gauges: top 0.6 mmand bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange). The panel should be Corroresist epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyrogrip noncombustible Portland cementitious core mixed with light weight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology upto 1 mm thickness for superior adhesion and Surface flatness within 0.75mm. The panel is to withstand a Concentrated Load of 363 kgs applied on area 25 mm x 25 mmwithout collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and an impact load of 50kg all complete as per the approved manufacturers specification and as per the direction of Engineer-in-charge. All specification must be printed on the side of the panel to ensure the quality of the product.
300 mm Finished Floor Height (FFH)
450 mm Finished Floor Height (FFH).
Repairing cracks in floor with cement mortar (1:2) with necessary pigment to match with existing works, including prior cutting and cleaning the cracks as directed.
50 mm thick interlocking designer concrete paver block M?30 grade for non-traffic zone,buiding premises,garden,parks,domestic drive as per IS: 15658- 2006(over 20-30 mm medium sand bed on 200mm thk bound gnaular /granular base course including cost of sand for sand bed but excluding cost of base course & subgrade preparation.)(ii) Coloured Decorative
Supplying fitting and fixing 600 mm ( ±30 mm) diametre R.B.T (Reinforced Barbed Tape) Concertina fencing on wall top using concertina coils stretched to approx.6 meters length at site clipped with two nos. of horizontal R.B.T strands which will be tensioned and fixed with the vertical M.S angle iron posts by means of security fasteners (such as 'C' clips, R.B.T clips etc.)
Labour for taking out (from fencing) line of wire (galvanised, strand or barbed) including the cost of taking out staples (by cutting or otherwise, as necessary).(Payment to be made on the length of the wire taken out.)
Supplying, fitting galvanised 3 ply 12 gauge / 4 points line of barbed wire in fencing (holes already made in the body of the post) or fixed by staples tightening and fixing the wires in taut condition with straining bolts including the cost of cutting and of lapping joints in the wire as necessary but excluding the cost of galvanised staples,straining bolt and binding wire where necessary.(Payment to be made on the length of individual lines of wire.)
Supplying galvanised straining bolts (with eye at one end with double nuts and washers) fitted and fixed complete. (ii) 12 mm. dia.(a) 200 mm.
Supplying galvanised staples fitted and fixed complete (a) 19 mm. to 25 mm. size
M.S. gate of Jail type as per approved design made of strong M.S.frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge.
Locking arrangement for Jail type doors including supplying fitting and fixing in position complete as per approved design.
M.S. works in brackets made from flats, angles, tees etc. to sizes specialy bent, twisted, forged; making holes drilled and fitted to rafter of trusses with necessary bolts, nuts, washer or screws etc.
M.S. or W.I. ornamental grill or approved design joints continuously welded with M.S., W.I. flats and bars of windows, railing etc fitted and fixed with necessary screws and lugs. (ii) Grill weighing above 16 Kg./sq.mtr and above
In Ground Floor
First floor
Second floor
Taking out heavy iron grated door or window (jail pattern or existing) with locking arrangement after cutting out from walls and refixing the same including mending all damages.
Taking out M.S. or W.I. Grills from wooden frame including cutting lugs from masonry wall and refitting the same and mending good damages after repairs.
Welding in M.S. structural work with gas or electric:
Tack weld.
Continuous weld.
M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-in?charge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural members only in finished work as per IS specified weight. Payment for gusset, bracket, cleat, rivets, bolts and nuts may be make by adding the actual weight of such items with the weight of finished structural members or 7% of weight for finished structural members weighing not less than 22.5 Kg. / m. or 15 % of weight for finished structal members weighing less than 22.5 Kg. / m. may be increased allow for bracket, cleat, rivet, bolts and nuts etc. and no seperate payment being made for these items, as per direction of Engineer In Charge. The rates are considered for a height of erection 8m. / 2nd floor level from the ground. .I) For structural members of specified sections weighing less than 22.5 Kg./m
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground.
Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx)
Wood work in door, window frame, and wall panelling frame work fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). (a) 1st class Best Indian teak.(d) Sal : Local
i) Ground Floor.
ii) First Floor
Plain and finished timber planks in partition, shelves etc. fitted and fixed complete as per design (butt joints) in ground floor.(iv) 32mm thick planks (b) Sishu / Champ / Badam / Gamar / Bhola / Mogra / Hallak
i) Ground Floor.
ii) First Floor
Wall panelling / partition with Melamine faced 3 layered flat pressed wood particle board of approved make and brand as per direction of Engineer - in -Charge of requisite grade bonded with phenol formaldehyde synthetic resin conforming to IS: 848 - 1974 (excluding the cost of supporting frame work and teak wood battens / lipping) Prelaminated particle board conforming to IS: 3087 - 1985 and IS 12823 - 1990. One side decorative laminated (b) Interior Grade 12mm thick in any floor
Supplying, fitting and fixing boiling water proof ply conforming to IS: 710-1977 bonded with phenol formaldehyde synthetic resin conforming to IS: 848-1974 of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in-Charge. [excluding the cost of supporting frame work and teak wood batten/Lipping] In any floor
(iii) 19mm
Partition of teak veneer [1 mm] as per design fitted and fixed complete (excluding the supporting frame work & necessary teak wood battens):(i) 4mm thick commercial quality in any Floor
Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on Particle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of Engineer-in?charge.The rate includes the cost of labour, adhesive and all incidental charges thereof. Glossy/Matt/Suede (i) Thickness of laminate 1.0 mm in
Ground Floor
First Floor
Second floor
Polyurethane Polishing to woodwork with required colour as approved by Engineer-in-Charge with preparing surface including scaffolding and hire charges of compressor machine including cost of filler and hardener material such as P. U. Sealing, P. U. Top coat (Matt/Glossy), Thinner, Spirit etc. and inclusive of all operation, material and labour complete as per direction of Engineer-in- Charge.
Melamine finish coating over polished wooden surface after preparing the surface as per decision and direction of Engineer-in-Charge
Providing and fixing stainless steel soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand to cupboard shutterswith full threaded steel screws including making necessary recess in board and finished etc. complete as per direction of Engineer-in-charge
Supplying fitting and fixing bubble free float glass of approved make and brand conforming to IS: 2835-1987; (Make: MODI GUARD, SAINT GOBAIN) (A) clear, toughened glass conforming to IS: 2553-1992 (part-II)
(i)6 mm thick clear glass
(ii) 8mm thick clear glass
(iii) 12mm thick clear glass
Supplying fitting and fixing bubble free float glass of approved make and brand conforming to IS: 2835-1987. (Make: MODI GUARD, SAINT GOBAIN).
i) 4 mm thick clear glass.
ii) 5mm thick clear glass
iii) 6 mm thick clear glass.
Supplying fitting and fixing Hyfrosted Film of approved quality fitted and fixed complete.
Supplying solid flush type doors of deluxe decorative (both side) quality, conforming to I:S 2202 timber frame consisting of top and bottom rail and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 27.5mm wide battens places both ways in order to made the door of solid core and internal lipping with teak, mahogony or rose wood approved decorative veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing the shutters in position but excluding the cost of hinges and other fittings (a) 35mm thick shutters (single leaf)
Ground floor
First floor
Second floor
Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolithic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria.. (i) 66mm x 90mm
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolithic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. (i) 32 mm thick
Ground floor
First floor
A) Supplying, fitting & fixing fire resistant door frame conforming to IS:3614, tested and certified as per laboratory approved by Engineer-in-charge, of section 143 x 57 mm having built in rebate made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/Sqm) duly filled with vermuculite based concrete mix, suitable for mounting 120 minutes fire rated door shutters. The frame is fitted with intumescent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with back plate bracket and anchor fastener of approved size and make. Rubber door silencers should be provided on striking jamb.
B) Supplying, fitting & fixing fire resistant Door leaf of 46 mm thick fully flush double skin glazed fire resistant door shutters with or without vision lite, of 120 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 18 SWG G.I. sheet (zinc coating not less than 120 gm/ m2) duly filled heat-resistant phenolic resin bonded insulation material (honeycomb craft) and fixing with necessary stainless steel ball bearing hinges of approved make.
For pair of doors astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturer recommendation with a beeding and screw from inside. The glass should be 6mm clear borosilicate fire rated glass of relevant rating. All door and frames shall be finished with polyurethene aliphatic grade paint of approved colour including applying a coat of approved brand fire resistant primer. The door leaf and frame shall have passed minimum 250 hours of salt spray test. Rate should include supply and installation complete as per direction of Engineer-in-charge. i) 2 hour Fire rated door single leaf of size (1200 mm x 2180 mm)
In Ground Floor
In 1st Floor
Supplying, fitting & fixing Surface mounted Crash Bar/ panic Bar of touch pad style, made of heavy duty cast iron/ steel body & latches with SS, BHMA certified & conforming to ANSI A 156.3 for grade-1 (3 hours fire rated) and suitable for surface mounting to wooden/hollow metal/ Al framed door with opening upto 900mm, with maximum operating force 6 kg for unlocking easily & outwardly during emergency, complete in all respect as per direction & satisfaction of Engineer-in-Charge. (Note: To be installed at "FIRE EXIT" only under location specific instruction of Eingineer-in -Charge.) for door opening 1200
Supplying, fitting & fixing asbestos free composite - 3 criteria- fire, heat and smoke check 100 mm thick fire Barrier of customised size & shape to prevent the spread of fire and smoke through vertical service line & utility shaft, having Fire Performance FD120 as per IS:3614 (Part-II) comprising of 4 x 12 mm thick Calcium Silicate boards affixed over internal frame work of 100mmx 50mm chemically treated timber with fire retardant chemicals in vaccum pressureimpregnation vessels under 160 PSI pressure as per IS:401 and kiln seasoned to moisture below 15% as per IS:1141 with 50 mm thick infill of ceramic fibre (density 98 Kg/Cum), vermaculite mix, reinforced by TMT 8 mm bars insertedinto frame both ways with maximum spacing of 300mm c/c supported within the the existing structure through SS anchore clamp of appropriate size, with spacing 300 mm c/c, with provision of cutouts for service & utility lines as per site condition & filling the space around with fire retardent Polyurethane foam and sealing all the joints with silicon sealant as per direction of Engineer-in- Charge complete in all respect including all incidental charges at all floors
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately)
40 mm. x 6 mm., 200 mm. length.
40mm X 6mm, 250mm Length
40mm X 6mm, 125mm Length
Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws:
(i) 50 x 45 x 2.5mm.
(ii) 65 x 45 x 2.5mm
(iii) 75 x 45 x 2.5mm.
(v) 100 x 63 x 3.2mm.
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:
50mm long x 10mm dia. Bolt
100mm long x 10mm dia. Bolt
150mm long x 10mm dia. Bolt
200mm long x 10mm dia. bolt.
225 mm. long x 10 mm. dia bolt
Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete. 250 mm x 16 mm dia bolt
Anodised aluminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: With continuous plate base (Hexagonal/ Round rod) With continuous plate base (Hexagonal/ Round rod)
(i) 75 mm grip x 10 mm dia rod
(ii) 100 mm grip x 10 mm dia rod.
(iii) 150 mm grip x 12 mm dia rod.
Supplying, fitting & fixing Stainless Steel 'D' or 'H' type of size 300 mm to 450mm x 19 mm tubular Handle with Grade 304, CE certified, marked & conforming to EN - 1154, of approved quality of reputed brand as per direction of Eingineer-in-Charge fitted and fixed complete including all incidental charge all floor
Supplying fitting and fixing of Aluminium casted body hydraulic door closer as per I.S.I. with necessary screws.
Supplying 'Godrej' mortice lock chromium plated with keys 6 levers including fitting & fixing complete.
Supplying fitting and fixing Anodised aluminium floor door stopper with necessary screws.
Supplying, fitting and fixing 125 mm. long wooden buffer block.With Sal : Siliguri.
Supplying heavy duty hydraulic double action floor spring along with top pin/set of pivots conforming to IS: 6315 or any approved make as per direction of Engineer in charge.
Providing and fixing of factory made uPVC Sliding window (White Colour) complete, (U value=1.9-1.3 W/m 2 K, flame resistant, self extinguishing, lead free) comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (±0.2 mm) duly reinforced with G.I. section 1.6 mm (±0.2 mm), wherever required. All corners of frame and sash will be fusion welded. After placing 5 mm Clear Annealed glass in the sash, uPVC glazing bead, interlock, EPDM gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window frame will be fixed to the wall with 100mm long and 8mm dia. Fasteners and after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size, of approved quality complete in all respect as per as per approved drawing & direction of Engineer-In-Charge. (Note: Profile manufacturer & Window Manufacturer must be one & same, Only manufacturer Waranty is aceptable)
a) 2 Track 2 Sash window frame of size 67 x 54 mm & Sash of size 64 x 47 mm both having wall thickness of 2.3 ± 0.2 mm
b) 3 Track 3 Sash window frame of size 122 x 54 mm & Sash of size 64 x 47 mm both having wall thickness of 2.3 ± 0.2 mm
Providing and fixing of factory made uPVC casement window (White Colour) (U value=1.9-1.3 W/m 2 K, flame resistant, self extinguishing, lead free) comprising uPVC multi-chambered frame, Sash, & Mullion with having wall thickness of 2.3 mm (±0.2 mm) duly reinforced with G.I. section 1.6 mm (±0.2 mm) made from roll forming process of required length. All corners of frame and sash will be fusion welded. mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's, uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. shall be provided in all frame, sash & mullion, wherever necessary. Thereafter, 5 mm clear annealed glass shall be provided in the sash with the help of uPVC glazing bead and hardware, i.e., stainless steel (SS 304 grade) friction hinges & zinc alloy (white powder coated) casement handles (in window) & 3D Hinges & Multipoint Lock (in door) shall be provided. Window frame shall be fixed to the wall with 100mm long and 8mm dia. Fasteners and after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size, of approved quality complete in all respect as per approved drawing & direction of Engineer-In- Charge. (Note: Profile manufacturer & Window Manufacturer must be one & same, Only manufacturer Waranty is aceptable)
a) i) Casement Window frame of size 45 x 50 mm & Sash / Mullion of size 45 x 78 mm (Window height below 1200 mm & building height below 18 mtr) both having wall thickness of 2.3 ± 0.2 mm
c) Fixed Window frame of size 67 x 62 mm & Mullion (if required) of size 67 x 78 mm both having wall thickness of 2.3 ± 0.2 mm
Providing and fixing of factory made uPVC Louver window (White Colour) (U value=1.9-1.3 W/m 2 K, flame resistant, self extinguishing, lead free) comprising of uPVC multi-chambered with wall thickness of 2.3mm (±0.2 mm ) duly reinforced with 1.6 mm (±0.2 mm) thick G. I. Section made from roll forming process of required length (shape & size according to uPVC profile). Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. Both vertical sides of the frame, adjustable louver mechanism having one lever shall be fitted with the provision of 4 mm glass. Window frame will be fixed to the wall with 100mm long and 8mm dia for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Fasteners and after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size, of approved quality complete in all respect as per as per approved drawing & direction of Engineer-in-Charge. (Note: Profile manufacturer & Window Manufacturer must be one & same, Only manufacturer Waranty is aceptable)
a) Louver Window with provision of Exhaust Fan frame of size 67 x 62 mm & Sash / Mullion of size 67 x 78 mm both having wall thickness of 2.3 ± 0.2 mm
Filling the gap in between aluminium frame & adjacent RCC / Brick/ Stone work by providing weather silicon sealant over 6mm dia backer rod of approved quality as per architectural drawings and direction of Engineer-in-Charge complete. Upto 5 mm depth and 5 mm width in all floors
Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composite door, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In?Charge. (Payment will be made on finished length of the work). II) Coloured
Fixed partitions. II) Coloured (Unsupported length of vertical member upto 1.5 mtr. Height of both ends of vertical member restrained but panels within 0.9 Sq.m)
i) Top , bottom & side member.
ii) Intermediate member.
iii) Glazing clip
Movable door shutter II) Coloured
i) Door frame. (Top & sides)
ii) Shutter :
Top rail.
Bottom rail.
Lock rail
Door vertical.
Glazing clip.
l) Rimless door.
Top & bottom rail
Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units:-
Fully glazed single leaf reamless swing door made of anodized aluminium alloy extrusions fabrication after cutting to proper shape and size, drilling and aligning fitted with heavy duty hydraulic action floor spring with top pin assembly and fitted with inbuilt locking arrangement and all other necessary fittings, fixture, adhesives and joineries, cutting the glass to requisite shape and size mounting the edges for fitting the same with dry set neoprine/EPDM gasket. The rate includes the hire charge of all tools and plants, adhesive, joineries but excludes the cost of extruded aluminium sections, glass, panel boards EPDM gasket, locking arrangement, weather gasket / woolpile, floor spring, top pin, handle, tower bolt etc.
Partly glazed and partly panelled partition or fixed glazing made of extruded and anodised alloy aluminium sections, fabrications after cutting to proper shape and size, drilling and aligning fitted with inbuilt locking arrangement cutting the glass / board (prelaminated / particle / block) to requisite shape and size moulding the edges fitted and fixed glazing clips and dry set neoprine /EPDM gasket, along with all other necessary arrangements for fixing the partition to walls, floors, beams, columns polysulphide sealant for water proofing if necessary complete in all respect as per drawing and specifications and direction of the Engineer in charge. I) For partitions using section of size: b) 101.50mm x 44.45 mm
EPDM gusket of approved make and brand as per direction of Engineer in charge.b) 'U' shaped/ 'T' shaped EPDM gasket for frames.
Supplying of approved make and brand as per direction of Engineer in charge weather gasket / wool pile for door vertical.
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. i) In all Floors
Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work) a) With 0.5 mm thick sheet
Galvanised or painted wind-tie made of M.S. flats, fitted and fixed complete including cost of necessary fittings.(b) Made with 50 mm. X 6 mm. flats
Galvanised iron sheet eaves gutter fitted and fixed with necessary 50 mm X 6 mm M.S flat bar clamps bent to design, bolts, nuts, washers etc. complete. Eaves gutter made of 0.63 mm. sheets.(300mm End lapping) (a) 225 mm. wide gutter
Designing of different customised curved & plain metal craft by laser cutting on different metal sheets of varying thickness for special architectural application as facade/wall panel/ceiling decoration as per design, drawing or as approved standard by the Engineer-in-charge including transportation. (Mode of measurement - linear /peripheral dimension of laser cut area), Aluminium Plate i) 2.0mm thick
Supplying, Fitting & fixing different factory made Metal Craft Sheet (including cost of metal crafting) incluing cost of powder coating (for M.S, Aluminium plate) & finished metal sheet with all fitting accessories complete in all respect as per diection of Engineer-in-Charge. Aluminium Plate i) 2.0mm thick
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid board one side white color and other side of board laminted with PVC foil of minimum 14 micron thickness of approved design pasted with hot melt adhesive for cup boards, work stations and bathroom/kitchen cabinet etc. of required sizes comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel piano hinges/soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel piano hinges/soft close clip on concealed hinges and necessary S.S screws shall be paid separately), Amulya Mica, Alstone or equivalent make. 18 mm thick
Providing and fixing of false celing with powder coated exposed Armstrong make or equivalent G.I. grid suspension system (E-Grid U-1520 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spaceing of 1200 mm c/c) consisting of main runner 3600 mm long. Cross tee 1200 mm / 600 mm long and wall angle. The wall angle shall be fixed on PVC Dash fasteners on the perimeter of the wall by steel screws with distance 300 mm c/c. The main runners to be placed @ 1200 mm. The cross tee 1200 mm will be inserted in the pre-cut slots of main runner at a regular interval of 600 mm to from a modular grid of 1200 mm x 600 mm. Grid of module size 600 mm x 600 mm shall be supported by 6mm dia. G.I. wire from purlins / soffit. 15 mm thick Armstrong make OW Acoustic Board (Mineral Fibre Acoustic Celling Tiles) of approved patern and size 595 mm x 595 mm with NRC value > 0.65 should be placed in the Grid module to from a False Celling. All complete as per the drawing & direction of Engineer-In-Charge. Acoustic False Ceiling (with 15mm thick OW Acoustic Board and E-Grid U-1520) Armstrong Make or equivalent.
P.V.C- False Ceiling : Providing False Ceiling made with framework of steel tube of 40mm x 20mm of not less than 18 gauge,the long and cross section will be welded with each other 1000mm to 1200mm apart the entire framework will be fixed in wall using rawlplug or gutties or screws etc. and suspended from ceiling with M.S flat 19mmx3mm as necessary,the entire frame will be painted with red oxide. PRINTED LAMINATED P.V.C Section 150mm x 12mmx 1.00mm (+/- 0.01mm) of approved quality and colour will be fixed on the frame so that the entire framework will not be visible from below P.V.C Section will be fixed with the frame with the help of self tapping steel screws including all materials and labour charges including fitting,fixing the same and hoisting including mending the damages in all respect and cost of paint as required as per direction of Engineer?in-Charge in all floors
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.in all floors
Providing and fixing, in position concealed G.I. section for wall paneling using board of required thickness fixed on the „W‟ profile (0.55 mm thick ) having a knurled web of 51.55 mm and two flanges of 26 mm each with lips of 10.55 mm, placed @ 610 mm C/C in perimeter channel having one flange of 20 mm and another flange of 30 mm with thickness of 0.55 mm and web of length 27 mm. Perimeter channel is fixed on the floor and the ceiling with the nylon sleeves @ 610 mm C/C with fully threaded self-tapping dry wall screws. Board is fixed to the„W‟ profile with 25 mm countersunk ribbed head screws @ 200 mm C/C., all complete as per the drawing & directions of Engineer-in-Charge, the joints of the boards are finished with specially formulated jointing compound and 48 mm wide jointing tape to provide seamless finish. a) 6 mm thick Multipurpose Cement board - Type-B (High Pressure steam cured, tested as per AS-1530 part 3 & BS-476 Part 4,5,6,7 & 8, density > 1450kg/m3, Bond strength 15 N/sqmm fire resistant, termite proof, moisture resistant) reinforced with cellulose fibre manufactured through autoclaving process as per IS : 14862 & ISO 8336, with fibre cement screws in partition as per drawings and direction of Engineer-in-Charge complete. (The above stated item can be used successfully to cover up efflorescence & damp affected walls to improve the aesthetic view)
Providing and fixing of roller blind with necessary arrangement for fixing of blind complete (including Control unit, ldler, Head rail, Bottom rail, operating chain, Fixing brackets & clamps, roller tube etc as per site requirement and direction of engineer-in?charge.) and fabric with the following specifications: 1) Composition: 3 Ply PVC+1 Ply Fiber Glass Black out 2) Coating: 1 Ply Fiber Glass Blackout 3) Weight: 560Gsm 4) Fabric Width: as per window width 5) Tearing Strength: 64 N Warp, 57 N Weft 6) Thickness:0.36 mm 7) Environmental Certificate: Green Guard Certificate 8) Color: Desired color 9) Other Properties Anti Fungal & Anti Bacterial Fabric all complete of approved quality and make as per the Direction of Engineer in charge.
Supplying & laying of approved make and brand of scratch proof, flexible & homogeneous Toll Coated Non-Woven Digital Print Wallpaper conforming to IS 15418 (2003) in required finish, fixed with synthetic acrylic adhesive after preparing the wall surface, levelling & smothaning when necessary with suitable putty, as per the design & instruction of the Engineer-in-charge.
Supply of Daily Unskilled labour with eight hours of actual work for loading, unloading, shifting of furniture and other ancilliary jobs
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.
(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.
(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia, (SAIL/TATA/RINL),
Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,Part-I. Payment will be made separetly on the basis of actual height based on relevant I.S.Code.A) With Pakur variety. (SAIL/TATA/RINL) 50 user septic tank
Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G . of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete.
Providing and fixing in position 12mm clear float toughened internal Glass partition of approved make with patch fittings for the full height glass partitions as per the direction of the engineer-in-charge. The work to include making necessary template for all the glasses and then cutting the clear float glass to correct size, making all the necessary holes, cuts etc., then toughen the same. (Saint Gobain/Asahi/Modiguard).The cost to include all hardware (PATCH FITTINGS etc) required of Hettich /Godrej/Dorma or approved equivalent make viz., single corner patch, top and bottom corner patch, Floor spring silicon etc. or as per the direction of the engineer-in-charge. The maximum size of each glass shall be 1200mm to 2000mm x 2400mm to 3000mm as per the site requirement. The rate is for a finished item of work etc., complete as directed. Glass partition will be fixed at bottom and top with patch fittings(as required). SS U-channel of 12mm X 25mm to be grouted with the floor.The cost to include the cost of bevelling and smoothening of the exposed edges of the glass. Note: For the Paneling, Full height partitions and low height partitions the work measurement for costing shall be only of the plain visible surface, no extra cost for extrusions or extra frame work required as per drawing will be made. The work done above ceiling, below floor finish level or not directly visible shall not be measured
Fully Glazed Door (Single Shutter): Providing and fixing fully glazed door of 12 mm thick toughened glass (Saint Gobain/Asahi/Modiguard) with pencil polish edges alround with etching patterns and bevelled at edges. The door shall be fixed with Hettich /Godrej/Dorma patch fitting assembily inclusive of top and bottom patches,pivots,automatic hydraulic door closer ,bottom locks,SS brushed handle of 60 cm long and 2.5 cm dia .Lock of approved make etc to be fixed to the door, the edge of the glass to be polished.The work to include making necessary template for all the glasses and then cutting the clear float glass to correct size, making all the necessary holes, cuts etc. as per direction of EIC.
Supplying,fitting and fixing of 6mm thick steel chequered plate over cable trench including cutting to sizes and making hole, etc. including cost of all labour and materials and placing in position over cable trences including incidental charges complete.
PHE WORK :
Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc.
(a) With 'P' trap
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.
Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete.
Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia.
(iv) 750 mm long
Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete.
(iv) Bestolite (solid type) white
Wash basin vitreous china of approved make (without fittings) supplied,fitted and fixed in position on 75mm X 75 mm X 75 mm wood blocks and C.I. brackets including two coats of painting of C.I. brackets.
(ii) 550 mm X 400 mm size
Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia.
Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm.
Supplying, fitting and fixing complete Bottle waste trap (Heavy Quality) (a) Chromium plated Bottle trap 32 mm with 190 mm long connecting pipe and wall flange (Equivalent to Code No. 545 & Model - Tropical / Sumthing Special of ESSCO or similar brand).
Supplying, fitting and fixing Waste fittings complete.
Supplying, fitting and fixing liquid soap container.
(a) Cromium plated.
Supplying, fitting and fixing bib cock or stop cock.
(d) (i) Chromium plated Angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand).
(a) (ii) Chromium plated Bib Cock long body with wall flange with aerator (Equivalent to Code No. 512 & Model - Tropical / Sumthing Special of ESSCO or similar brand).
(a) (i) Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand).
Supplying, fitting and fixing shower of approved brand and make.
(e) Chromium plated double coat Hook (Equivalent to Code No. 35761 & Model - KUBIX of Jaquar or similar).
(f) Hand Shower (Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar).
Supplying, fitting and fixing pillar cock of approved make.
f) (i) CP Pillar Cock with 200 mm extended Lever Handle (Equivalent to Code No. 5031 & Model - FLORENTINE of JAQUAR or similar brand).
f) (ii) CP 2-way bib Cock - 15 mm, supplied, fitted and fixed. (Code No.5041 & Model - FLORENTINE of JAQUAR or similar brand).
Supplying, fitting and fixing water purifier with RO+UV filtration system with necessary fittings of approved make.
Supplying, fitting and fixing towel rail with two brackets.
(a) C.P. over brass
(ii) 25 mm dia. and 600 mm long
Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete.
(i) 635 mm X 395 mm X 420 mm
Supplying, fitting and fixing dome shaped C.P. waste grating for urinals.
Supplying, fitting and fixing porcelain partition wall of approved make of size 618 mm X 310 mm complete in all respect.
Supplying, fitting and fixing C.P. Extension Pipe
Supplying, fitting and fixing C.P. Wall Flange
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992
(A) (i) Single Socketed 3 Meter Length
(B) Fittings
(iii) Door Tee
v) Plain Y
ix) Bend 45º
x) Bend 87.5º
xv) Vent Cowl
xvi) Pipe Clip
xxi) 110mm P Trap
vii) Double Y
Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in-charge. (Payment will be made on centre line measurement of the total pipeline including specials.
(A)Above ground
(ii) 110 mm dia.
(iii) 160 mm dia.
(B)Under ground
(ii) 110 mm dia.
(iii) 160 mm dia.
Supplying, fitting & fixing Aluminium domical grating
Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007
(Q) Ball Valve
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. (ii) CPVC Pipes Class-2,SDR-13.5
For Concealed Work
For Exposed Work
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)
For Exposed Work
20 mm dia
25 mm dia
32 mm dia.
40 mm dia.
50 mm dia.
Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only).
20 mm dia
25 mm dia
32 mm dia
40 mm dia
50 mm dia
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling,15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab, excluding cost of RCC manhole cover and including fixing of manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials.
With Pakur variety. (SAIL/TATA/RINL)
iii) Extra for each additional depth of 150 mm or part thereof beyond initial 600 mm depth.
Constructing Inspection pit to a depth of 1.5 metre (inside), 250 mm thick 1st class brick work (1:4) in all sides over a layer of jhama brick soling and 150 mm thick cement concrete with stone chips (1:3:6) including necessary earth work, fitting and fixing approved type S.W. master trap, constructing masonry invert with cement concrete (1:1.5:3) with stone chips, plastering inside and outside (outside upto 300 mm below G.L.) with 20 mm thick cement plastering (1:4) and neat cement punning, excluding cost of RCC manhole cover and including fixing of manhole cover of approved make with R.C.C. slab of 100 mm thick with cement concrete (1:1.5:3) with stone chips including necessary reinforcement (upto 1%) and shuttering and necessary corbelling brick work (1:4) so that the R.C.C. cover slab rests 150 mm above adjucent G.L., cement plaster (1:4) 10 mm thick on all external surfaces of the top slab as directed complete in all respect and removal of surplus earth with all costs of labour and materials (excluding the cost of master trap only).
(i) 900 mm X 750 mm (inside) chamber
ii) With Pakur (SAIL/TATA/RINL)
Supplying, fitting and fixing in position reinforced cement polymer concrete manhole /gully pit cover with matching frame.As per I.S-12592(M.D)
(ii) 25 MT load bearing capacity round manhole cover provided with two lifter hooks fitted with matching frame of size Cover: 680 mm X 90 mm Frame: 800 mm X 165 mm opening: 500mm Weight: 196 kg (approx)
Supplying, fitting and fixing in position FRP/GRP/ COMPOSITE UV stabilizer Gully Pit Cover with high abrasion surface of 7mm top thicknes, density of 2KG/m³ of approved make with rim of approved make (Heavy type)
(ii) 20 M.T. Gully pit cover (yard gully) with arrangement for opening of size Frame Clear Opening 600 mm X 600 mm. Cover Out to Out 660 mm X 660 mm.
Supplying & laying Double Wall Corrugated (with external annular corrugation and smooth internal walls) High Density Polyethelene Pipes conforming to IS 16098 (Part-II):2013 having Stiffness Class of SN 8 with Ring Stiffness not less than 8.00 KN/Sqm. and Impact Resistance TIR value not more than 10% including necessary jointing materials for non-pressure underground Drainage, Sewerage & Cross drainage application.
150mm internal dia.
200mm internal dia.
250mm internal dia.
400mm internal dia.
500mm internal dia.
Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.)
40 mm dia. medium quality
32 mm dia. medium quality
Supplying,fitting and fixing check valve (horizontal) G.M. tested to 21 kg per sq. cm.
Supplying,fitting and fixing Open well submersible pump having flow of 5 cu. Mtr. Per hour @ 25 mtr head
Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets.
(b) Sink with drain board 1050 mm X 450 mm X 180 mm
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer
(c) 1500 litre capacity
Labour for hoisting plastic water storage tank.
(ii) Above 1500 litre upto 5000 litre capacity.
(a) Upto 1st story from G.L.
(b) Extra for each additional story
Labour for punching hole in plastic water storage tank upto 50 mm dia.
Supplying, installation, testing and comissioning of water cooler with UV protection of Blue star, Eureka Forbs, Voltas, Kent or Equvalent Item Description : Water Storage Tank - 120 Ltr. Capacity with Comfort Level Outlet – 60/ 80 Ltr. Outlet Water Temp - 17 DegC +/-1 DegC UV filtration - Yes No. of Purification Stages – Minimum 3 Storage Tank Material - SS 304 Outer Body Material - Front SS 304, Rest Powder Coated Steel Number of Faucets - 2 Cold + 1 normal With Visual Controls (LED) Cooling off/on switch Water Flow rate through faucet – 1.5 LPM Suitable Stand (MS with powder coated)
Labour for dismantling G.I. pipe with fittings.
(iii) 25 mm
Cutting out section of G.I. water main pipe upto 100 mm.
Dismantling H.C.I. pipe with fittings including melting lead caulked joints.
(iii) 100 mm
Dismantling and refixing bib cock or stop cock.
Dismantling wash basin with brackets with or without waste fittings.
Dismantling sink with brackets with or without waste fittings.
(ii) Above 450 mm and upto 600 mm length
Dismantling pillar cock of wash basin.
Dismantling E.P. or Anglo-Indian W.C.
Dismantling urinal.
Removing sludge from septic tank, soak well etc. by methor labour including disposal of the same outside the compound as directed.
c) Upto 50 users:-
(i) Within a lead of 150 metre
Tracing out underground pipe or pit by opening out test trench including filling it up
Dismantling yard gully with gratings.
Cleaning silt of inspection pit.
Making connection with the existing pit.
Dismantling and refixing drain pipe including cutting trench and refilling the same.
Dismantling & Refixing pit cover
Cleaning silt of inspection pit.
FIRE DETECTION AND FIRE ALARM SYSTEM :
FIRST AID FIRE EXTINGUISHERS
SITC of approved make 6 kg Dry chemical powder (DCP) stored pressure type ABC extinguisher with chromium plated gunmetal nozzle on the top of the fire extinguisher for discharge of liquid & chromium bottom gunmetal union (cap) at the fire extinguisher with handle fixed at the center, complete with bracket fixing screws, spanner & one filling. Extinguisher should bear ISI mark.
SITC of approved make 4.5kg carbon - di - oxide fire extinguisher made of high pressure steel cylinder complete with wheel type valve, with one meter long braided high pressure discharge hose which should have a minimum bursting pressure of 14 kg & fitted with ABS discharge horn & handle on the body fully charged, with ISI make (IS 2878).
SITC of modular type ceiling mounted ABC fire Extinguisher of 10kg capacity for panel rooms.
CONVENTIONAL FIRE DETECTION AND ALARM SYSTEM
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
Supplying, installation, testing & commissioning of heat detector operating at 54°C/57°C with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required.
Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
17.5.3 Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. speaker cable Two pair, 2-core, 1.5 sqmm
Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as reouired.
Exit Signage / Other Signages as per requirement.
Gas based Fire suppression System
SITC of CCOE/PESO Approved Seamless Gas Cylinder and Valve Assembly, 140Ltrs. Capacity, OEM Factory filled with Novec 1230 / Clean Agent / FK5112 (UL / VDS Listed) Suppression Liquid.
SITC of Novec 1230 / Clean Agent / FK5112 (UL / VDS Listed) with Zero Ozone Depleation Potential and very Low Global Warming Potential of 1 with 20 Years Blue Sky Warrantee against any regulatory Bans and restrictions.
SITC of UL/VDS Listed Master Kit for Multi Cylinder System Comprising of Pressure Gauge, Low Pressure Supervisory Switch, Electric Actuator, Pnumatic Actuator, Manual Actuator, Flexible Discharge Hose, Interconnecting Hose etc.
Manifold discharge pressure switch with Release pressure min 3 bar with potential free contact 2 NO/2 NC Ingress protection rate IP54
SITC of Gas discharge Nozzles as per approved hydraulic flow calculations.
SITC of Manifold of M.S. Seamless pipes as per ASTM A 106 Gr. B. Sch. 40 to Be Used for Piping.
SITC of Wall Bracket and Cylinder mounting straps as required to hold the cylinders at wall.
SITC of M.S Seamless pipes as per ASTM A 106 Gr.B, schedule 40 size 50mm with necessary fittings -
SITC of M.S Seamless pipes as per ASTM A 106 Gr.B, schedule 40 size 65mm with necessary fittings.
SITC of M.S Seamless pipes as per ASTM A 106 Gr.B, schedule 40 size 80mm with necessary fittings.
SITC of Bleeder Valve
SITC of Non Return Valve
SITC of Gas release Panel 2 Zone Gas Release Panel AC Power: 230 VAC,60/50 Hz Operating Condition Operating Temperature : 0-49°
SITC of Manual Abort Switch with connecting cables.
ELECTRICAL :
Part-A(Electrical Installation work)
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make: Legrand/Havells/Crabtree/Seimens/L&T) 4 way VTPN DB [I/C: 125A FP MCCB + O/G: 63A TP MCB]
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection. (Make: Legrand/ Havells/ Crabtree/ Seimens/ L&T) 125A FP MCCB
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (Make: Legrand/ Havells/ Crabtree/ Seimens/ L&T) 63A TP MCB
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.[For AC].(Make: Legrand/ Havells/ Crabtree/ Seimens/ L&T) 4 way TPN MCB DB [I/C : 63A FP Isolator+ O/G: (6-32)A SP MCB] (For AC)
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. (Make: Legrand/ Havells/ Crabtree/ Seimens/ L&T) 63A FP Isolator
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (Make: Legrand/Havells,Crabtree/Seimens/L&T)
(6-32) A SP MCB
32A DP MCB
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make:Legrand/ Havells/ Crabtree/ Seimens/ L&T).
2+12 Way SPN MCB DB[I/C: 63A DP Isolator+O/G: 32A DP MCB] (For UPS Main DB)
2+10 Way SPN MCB DB [I/C: 32A DP Isolator+ O/G: (6-32)A SPMCB] (For UPS Sub DB)
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. (Make: Legrand/ Havells/ Crabtree/ Seimens/ L&T)
63A DP Isolator
32A DP Isolator
Supply and delivery of following size 1.1 kV grade PVC/XLPE insulated Armoured (Aluminium core) LT cable. (Make-KEI/ Polycab/ Fenolex/ Havells)
4 core 300 sqmm. (From main supply/ Metering panel to 315A TPN SFU & from 315A TPN SFU to Bus Bar)
4 core 50 sqmm. (From Panel to VTPN DBs)
4 core 25 sqmm. (From Panel to VTPN DBs)
4 core 10 sqmm.( From Panel to, for Pump & B/B chamber for Compound Illumination)
2 core 10 sqmm. (Compound Illumination and where neccessary as per direction of EIC)
Supply of following size L.T. cable, working voltage 1.1 KV grade, heavy duty XLPE insulated, unarmoured, screened, stranded, COPPER distribution power conductor cable.
1C, 16 sqmm. CU
1C, 25 sqmm. CU
1C, 35 sqmm. CU
LAYING OF CABLE- Laying of one No. cable above 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
4core 300 sqmm.
Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
4core 50 sqmm.
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
4 core 10 sqmm.
2core 10 sqmm.
Laying of cable above 3/3.5 core 35 sqmm and upto 3/4 core 50 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
4core 50 sqmm.
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
4 core 10 sq mm
Laying of cable upto 2 core 25 sqmm on wall/surfaceincl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
2 core 10 sqmm.
Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4core
2 core 10 sq mm
Supply & Laying of RCC spun pipe for cable protection :225 mm Dia
GLAND AND FINISHING- Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
4 core 300 sqmm
4 core 50sqmm
4 core 10sqmm
2 core 10sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials
4core 300 sqmm
4core 50 sqmm
4core 10 sqmm
2core 10 sqmm
Supply & fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl.S&F GI connector,6mm dia MS suspender,bolt & nuts ,steel fastener etc.as required of the following size incl. AI paintaing MS (without angle support)
Supply & fixing of perforated GI cable tray bend with perforation not more than 17.5% suspended from ceiling with two nos. suspender & 25*25*3 mm angle iron for supporting the cross member incl.S&F GI connector 6mm dia MS suspender,bolt & nuts ,steel fastener etc.as required of the following size incl. AI paintaing MS
Supply & fixing of perforated GI cable tray tee with perforation not more than 17.5% suspended from ceiling with two nos. suspender & 25*25*3 mm angle iron for supporting the cross member incl.S&F GI connector 6mm dia MS suspender,bolt & nuts ,steel fastener etc.as required of the following size incl. AI paintaing MS
Supply & fixing of perforated GI cable tray cross member with perforation not more than 17.5% suspended from ceiling with two nos. suspender & 25*25*3 mm angle iron for supporting the cross member incl.S&F GI connector 6mm dia MS suspender,bolt & nuts ,steel fastener etc.as required of the following size incl. AI paintaing MS
Supply & fixing of perforated GI cable tray reducer with perforation not more than 17.5% suspended from ceiling with two nos. suspender & 25*25*3 mm angle iron for supporting the cross member incl.S&F GI connector 6mm dia MS suspender,bolt & nuts ,steel fastener etc.as required of the following size incl. AI paintaing MS
Supply & Fixing 240 V, 6/16 A, 3/5 pin Modular type plug socket with 16A Modular type switch, without plug top on 3 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [Sep 16A Plug]. (Make: Legrand/ Havells/ Crabtree/ Anchor)
Supply and fixing 4 nos 6/10A plug socket with 4 nos 6/10A Switch in 12 way PVC Box with Modular Top cover plate for Computer connection with necessary connection with 1.5 sq.mm. PVC cu wire. (Make: Legrand/ Havells/ Crabtree/ Anchor)
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board.
Supplying & Fixing of 10 A Bell Push with necessary connection with 1.5 sq.mm. PVC cu wire. (Make: Legrand/ Havells/ Crabtree/ Anchor)
Supply,fixing & electrical connection (including freight, insurance, incidental charges,Taxes etc) with 25A, 240V Moduler type starter(brand approved by EIC) & 25A,DP Moduler type MCB on 4 moduler type PVC box with moduler top cover plate flushed in wall incl. and making necessary connection with PVC cu wire and earth continuity wire etc. (Make: Legrand/ Havells/ Crabtree/ Anchor)
Supply,fixing & electrical connection (including freight, insurance, incidental charges,Taxes etc) with 32A, 240V Moduler type starter(brand approved by EIC) & 32A,DP Moduler type MCB on 4 moduler type PVC box with moduler top cover plate flushed in wall incl. and making necessary connection with PVC cu wire and earth continuity wire etc. (Make: Legrand/ Havells/ Crabtree/ Anchor)
Supply,fixing & electrical connection (including freight, insurance, incidental charges,Taxes etc) L&T Motor Starter Direct On Line (DOL)
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket, without plug top and switch with 2 Module type PVC box with top cover plate in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make: Legrand/ Havells/ Crabtree/ Anchor)
Supply & Fixing 240 V, 25 A, 3 pin plug top with indicator and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make: Legrand/ Havells/ Crabtree/ Anchor)
Supply & Fixing 250 V, 32 A, 2P+E Pole Industrial Plug & Industrial Wall mounted Socket 2P+E and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make: Legrand/ Havells/ Crabtree/ Anchor)
Supply & Fixing 250 V, 32 A, 3P+N+E Pole Industrial Plug & Industrial Wall mounted Socket 3P+N+E and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make: Legrand/ Havells/ Crabtree/ Anchor)
Supplying & Fixing of 240V, 0.5 W-1W, LED Lamp ( Deep Red colour), B22 base. (Make: Philips/ Crompton/ Havells/ Jaquar)
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works.
20 mm Size
25 mm Size
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
Supply/Delivery with fitting & fixing following 250 Volt, 18 Watt, 4 Ft. long Twin LED Tube complete with LED Poly carbonate tube lamp having at least 110 lumen/watt and cast iron box type fittings or equivalant as per direction of E.I.C. (Make: Philips/ Crompton/ Havells/ Jaquar) Twin LED Tube with fitting (18 Watt)
Extra for suspension exceeding 25 cm with S&F additional 2 no.20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. Length.
Supply, delivery, fitting, fixing & electrical connection (including freight, insurance, incidental charges etc as applicable) of Philips make polycarbonate 18W 2100 lumen LED tube Light including TMC 501 1xTLED fittings
Supply & Fixing 250 volt. A.C. Ceiling fan complete with all accessories (without regulator) 1200 mm sweep (CG-Crompton Greaves-HS Plus / Usha-Technix / Orient Quasar-Pearl White/ equivalent as per choice of Controlling Officer).
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. (Make: Havells/ Crabtree/ Anchor/ Crompton).
Supplying & Delivery of 250 volts, 50 Hz 400mm sweep Wall Mount Fan complete with all accessories including connections as reqd. as per choice of E.I.C. (Make-CG- WM High Speed/equivalent from Orient,Usha,Colour-as per choice of Controlling Officer ). 400 mm Sweep.
Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. Length.
Supply & fixing following LED recessed mounted 2'x2' luminaires fully diffused as per direction of E.I.C. (Make- Philips Cat No. RC740B LED36S/865 W60L60 PSU WH or equivalent model of CROMPTON / BAJAJCrompton/Bajaj//equivalent as per choice of Controlling Officer).
Supply and fixing 240V,12-16W recessed downlight for false ceiling with 700 to 2000 lumen Round/Square LED panel on ceiling and necessary connection as required as to GS.(Philips/CG/Jaquar) as per choice of EIC. [ Dinning ]DN296B LED12S-6500 PSU WH SG or equivalent model of CROMPTON / BAJAJ
Supply & Fixing of circular recessed LED Downlighter , made up of pressure die cast aluminum housing with high efficiency PS diffuser, LED Used shall be SMD type and fixture should have minimum efficacy at System level >=100 lumens/watt with Minimum system Lumens 1000 & max wattage 10W.Similar to Signify DN295B LED10S-6500 PSU WH SG or equivalent model of CROMPTON / BAJAJ.
Supply & Fixing of 10W 300MM LED mirror light will give nominal system lumen output of 1000lm and a minimum system efficacy of 100lm/W. The luminare should have color temperature of 3000K ,CRI≥80, THD <20% and PF ≥0.90. The luminaire shall meet IP20 having MS housing with polycarbonate diffuser for better light distribution., i.e. similar to Philips MERAKI Model No. 582108 or equivalent model of CROMPTON / BAJAJ
Supply & Fixing of Magnetic track with input voltage 24V DC, with maximum weight 2.82 kg. Dimension 2000 mm x 30.5 mm x 53 mm with I connetion module ST307Z IECP, ST307Z 150W PSU driver, ST307Z driver connection module, Supply of 9W magnetic track spot light (including all accessories), with Al housing and PC optical cover, with wide (36 degree beam angle), CRI 90, SDCM≤5, IP20, IK03, CCT 4000K, black housing color, class III safety class, 24V DC input voltage. Similar to Philips make or equivalent model of CROMPTON / BAJAJ
Supply & Fixing of slim, flexible outdoor rated IP68 LED luminaire (with IP 65 Aluminium profile and driver) for uniform white light. The luminaire housing should be of extruded silicone material with frosted silicone lens. The input voltage should be 24V DC and total power consumption each run length of 5m should not be more than 12W/m.CE, CQC certifications and must be BIS certified. Similar to Philips make Unilinear Flex 5m Module, IP 68, Warm White(In meter) or equivalent model of CROMPTON / BAJAJ
Supply & fitting of Linear 1000MM length wall washer, exterior rated 3000K, CRI 80, wall washer light complete with all accessories like leader cable, jumper cable, male-female connector etc; suitable for facade Lighting, dimension not exceeding 1000mm x 55mm x 45mm(Without Bracket) and 1000mm x 105mm x 45mm(With Bracket). The housing material of fixture should be Die-cast aluminium, powder-coated finish with Antiaging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. The system wattage not exceeding 50W and system lumen output of not less than 2460 lumens at 3000K, 16X35 deg ,THD<20 %. Both the fixture and Driver should have separate BIS approval. Similar to Signify Cat:BCP383 M 24LED 30K 220V A2 L100 or equivalent model of CROMPTON / BAJAJ
Supply & fixing of 3000K, CRI≥80 LED wall washing and grazing luminaire (including driver) length 1000mm made of Extruded aluminum with die-cast aluminum end caps, Electrostatically applied polyester powder coating, system wattage 24 Watt with minimum system lumens of 1660 lumens with all channel ON.Both the fixture and Driver should have separate BIS approval. Signify BCP381 24LED 30K 24V 30 L100 IN or equivalent model of CROMPTON / BAJAJ
Supply of IP65 Surface Mounted Downlighter of Maximum 12W with 840 lm (Minimum System Lumen Output). CCT is Warm White. Signify IP65 Downlight or equivalent model of CROMPTON / BAJAJ
Supplying & fixing 12W LED Picture Light fixture. Make-31403 of PHILIPS OR equivqlent model of CROMPTON /BAJAJ / HAVELLS as per direction of EIC.
Supplying & fixing 12W LED Spike light fixture. MAKE -31386 of PHILIPS . OR equivqlent model of CROMPTON /BAJAJ / HAVELLS as per direction of EIC.
Supplying & fixing 5W LED Step Light fixture. MAKE -31435 (IP65) of PHILIPS . OR equivqlent model of CROMPTON /BAJAJ / HAVELLS as per direction of EIC.
Supply of LED Strip (with driver) with 15.5w/m with input voltage 24VDC ±10%, CRI 90, IP20, IK03, Life 30,000 hrs (ta 25°C) @B50L70, Class III electrical, SDCM ≤3, CCT 4000K.Similar to Philips make or equivalent model of CROMPTON / BAJAJ
Supplying and fixing Sheet steel Main Switches on angle iron frame on wall 100/125 Amp 415 V TPN with fuse on L&N Havells
Supplying & fixing Turbo Force 300MM Exhaust Fan Make- HAVELLS or EQU ORIENT/USHA/POLAR as per direction of EIC.
DISTRIBUTION WIRING- Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish (Make: Legrand (Arteor/Myrius)/ Schneider) Make:KEI/Polycab/Fenolex/Havells 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC
Avg run 6 mtr
Avg run 8 mtr
Avg run 10 mtr
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish (Make: Legrand (Arteor/Myrius)/ Schneider) Make:KEI/Polycab/Fenolex/Havells a)2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC
On Board
Average run 7.5 mtr
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes through 25mm/19 mm bore 3 mm thick polythene pipe and by the GI fish wire and making necy. connection as required as per direction of E.I.C. Make:KEI/Polycab/Fenolex/Havells
4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC in 25 mm pipe ( VTPN to TPNDB )
2x6 sqmm+1x 4 sqmm ECC) in 19 mm pipe ( TPNDB to SPNDBs)
2x4 sqmm+1x 2.5 sqmm ECC in 19 mm pipe ( TPNDB to AC)
2x2.5 sqmm+1x 1.5 sqmm ECC in 19 mm pipe ( SPNDB to SB, Composite board)(TPNDB to 15A PP)
3 x 22/0.3 (1.5 sqmm) in 19mm pipe (for Group Controled Stair light & Corridor, down light, Loop box to Gate light & others)
EARTHING- Excavation of soil for installation of Earth Electrode and filling & ramming.
For Soft Soil
Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts.long and 1 x 19/8 stranded GI (Hot Dip) wire (4 Mts. long), 25mm dia x 150 mm long galvanized bolt, double nuts, doublewashers including socketing at both ends of stranded GI (HotDip) wire by crimping sockets/ thimbles and S & F 40 mm diaGI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above groundlevel to an average depth of 3.65 Mts
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages : No. 6 SWG
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
Extra for treatment of soil by using salt & charcoal or coke for plate electrode
SITC of Lightning Conductor- Air terminal :-
S & F Lightning conductor Air-terminals made of 15 mm dia 1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1)
Down Conductor :-
Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles 1100 mm apart incl. mending good the damages to buildingworks
Supply & fixing of GI (Hot Dip) strips 20 mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart incl. mending good damages to building work
Making soldered joints between conductor/ conductor & air terminals by 7/10 stranded GI (Hot Dip) wire incl. supply of jointing materials & painting with 2 (two) coats of Bituminous paint
Making soldered joints between conductor/ down pipes / other metallic objects by 7/10 stranded GI (Hot Dip) wire incl. supply of jointing materials & painting with 2 (two) coats ofBituminous paint
Supply & Fixing of Testing Joints by 20 mm x 3 mm thick GI (HotDip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S & F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as required
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation of overhead reservoir (vertical run)
Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the building works- Length upto 0.5 Mtr
Part-B(A.C Installation)
Supply, installation, testing and commissioning of VRF/VRV indoor units consists of a multirow deep copper cooling coil with aluminium fins, thermostatic expansion valves, blower section with statically and dynamically blanced centrifugal blower with motor, synthetic fibre filters, insulated drain pan, safety control, thermostat etc. The units shall have first charge of R-410A refrigerant, controls, electricals, necessary accessories etc of minimum capacity as below. The units shall run as heat pumps at winters.
2.5 TR 4-way Cassette unit with cordless remote.
2 TR 4-way Cassette unit with cordless remote.
1.3 TR 4-way Cassette unit with cordless remote.
1 TR 4-way Cassette unit with cordless remote.
1.6 TR wall mounted unit.
1.3 TR wall mounted unit.
Supply, installation, testing and commissioning of the following inverter type VRF/VRV outdoor units with compressor, air cooled condenser and fans with R410A refrigerant, controls, electricals, necessary accessories of minimum capacity as below. The units shall run as heat pumps at winters.
Supply, installation, testing and commissioning of inverter split air-conditioning units, each comprising of single outdoor unit and single indoor Hi wall unit. Outdoor condensing units shall comprising of inverter scroll or rotary compressors, air cooled condensers and fans. The units shall have first charge of R-32 refrigerant, controls, electricals, necessary insulated refrigerant pipes, accessories, 5 star rating with cordless remote.
2 TR 4-way Cassette unit with cordless remote., 5-star rating.
1.5 TR Hi wall Unit with cordless remote, 5-star rating.
1 TR Hi wall Unit with cordless remote, 5-star rating.
Supplying, fitting and fixing 2.4 TR Daikin Tower AC, Coil Material: Copper, Model Name/Number: RR71CGXY1A6 without inverter. FVRN71AXV16
Supply, installation, testing and commissioning of Refrigeration Network (Refnet) joints per sets as required.
Supply, installation, testing and commissioning of the following sizes Cu. refrigerant pipes of required thickness duly insulated with 19mm/13mm close cell elastometric nitrite rubber insulation between each set of outdoor and indoor units. Flexible joints shall be proded where pipes passing expansion joints.
34.9 mm outer dia with 13mm thick insulation.
28.6mm outer dia with 13mm thick insulation.
22.2mm outer dia with 13 mm thick insulation.
19.1mm outer dia with 13 mm thick insulation.
15.9mm outer dia with 13 mm thick insulation.
12.7mm outer dia with 13 mm thick insulation.
9.5mm outer dia with 13 mm thick insulation.
6.4mm outer dia with 13 mm thick insulation.
Supply, installation, testing and commissioning of UPVC pipe medium class (For drainage of water from IDU) including bends, sockets, tees etc with 9mm thick Nitrile Rubber insulation.
Supply, installation, testing and commissioning of UPVC pipe medium class for fresh air intake to Cassette unit.
Supplying, fixing, testing & commissioning of aluminium powder coated fresh air intake circular louvre.
Supply, installation, testing and commissioning of Group remote controller with network converter 20 capacity. One at each floor.
VRF loop Cabling 4C x 1.5 Sqmm Flexible Cable with Conduit.
Supply, installation, testing and commissioning of following ODU electrical panel , cubicle wall mounted, indoor type IP:42, factory fabricated with 2 mm thick sheet steel, with copper bus bars, complete with switchgear/mountings cable terminations, inter-connections, on-off starter, indication lamp as required, for 415 volts, 3 phase, 4 wire 50 HZ, AC supply suitable for 35 MVA rupturing capacity ratings of switch gears etc. of incoming and outgoing feeders for 16HP & 22HP capacity ODU, 3 phase and 1no spare.
Supply, laying, testing and commissioning of PVC insulated, PVC sheathed armoured, 1.1 KV grade Copper conductor cables with cable glands on walls /ceiling/ trays etc. as required including necessary hardware required for clamping namely spacers, saddles, screws, nuts, bolts etc. all complete as per tender specification IS:7098 (Part 1) marked , with end termination.
4 Core x 16 sq mm Cu (ODU Panel to ODU)
Supply, installation, testing and commissioning of timer panel with accessories all complete for operating running and stand by AC (2R+1S) in every 8 hrs.
Supply, installation, testing and commissioning of 2.0 TR capacity 5-star rated split type Copper Condensor Inverter Air-conditioning machines with remote , 230 Volt + 5%, 50 Hz, Single phase with installation. (Carrier/Daikin/Blue star/Hitachi/Voltas).
Supply, installation, testing and commissioning of 1.5 TR capacity 5-star rated split type Copper Condensor Inverter Air-conditioning machines with remote 230 Volt + 5%, 50 Hz, Single phase with installation. (Carrier/Daikin/Blue star/Hitachi/Voltas)
ODU Powder coated Angle for Split AC only
DRAIN PIPING: 25MM Thick PVC Drain Piping upto ODU
COPPER CONTROL CABLE: (ISI Cable) - 4 or 3 Core X 2.5 Sqmm
Split AC machines dismantaling charges
Same Machines Re-install & Gas charging
Hiring of Mazdoor (Male)for wire removing etc.
Part-C(L.T Panel)
a) Designing, manufacturing, testing, supplying and erecting at site vertical floor mounting free standing/floor mounting extensible on either side, compartmentalised multitier cubical type panel board made of 14 SWG CRCA MS sheet suitable for 500/415V, 50 HZ, AC, 3 Phase and neutral system having the following features.
i) The panel shall be designed to ensure IP 54 degree of protection and also that the weight of the components is adequately supported without deformation or loss in alignment.
ii) The doors of the cubicle shall be fitted with dust protective neoprene gaskets with fasteners for proper compression of the gaskets.
iii) Busbars shall be of continuous rated Aluminium conforming latest relevant IS up to date adequate for specified rated continuous and short circuit current covered by proper graded colour coded heat shrinkable PVC sleeves. Busbars shall be supported by suitable hylam insulator supports. High tensile bolts and spring washers are to be provided on all busbars and suitable drilled holes for connection. The interconnections between the busbars and the circuit breakers shall be made by continuous rated Aluminium strips suitably covered by proper graded heat shrinkable colour coded PVC sleeves or by unarmoured copper cable. The earth busbar/s shall run through the length of the panel and terminated at two ends.
vi) Adequate cabling space should be available in the panel with cable supports, cable alleys etc. Provision for top/bottom entry and termination of required number of A2XFY/A2X WY cable shall be provided. The position of control switches, push buttons, levers, etc requiring manual operation shall be at a height not exceeding 1850 mm from the finished floor level.
vii) The panel shall also comprise of necessary meters, CTs, protection MCBs fuses, indication lamps, thermal relays, contactors, auto manual switches, lifting bolts, label inscriptions (metallic engraved identification tags) describing the rating of the breakers, name of the feeders etc including all other accessories, complete as per IE Rules and regulations conforming to relevant IS and duly approved and inspected by Client/Consultant. The rate shall include necessary cutting chases and mending good damages during installation. The panel shall have the following major components.
UPS PANEL-2
INCOMER
2 Nos 63 A, 4P MCB ,415V, C curve
OUTGOING
5 Nos 40 A, 4P MCB ,415V, C curve
1 No.Danger Board.
UPS PANEL-1
INCOMER
2 Nos 32 A, 4P MCB ,415V, C curve
OUTGOING
5 Nos 40 A, 4P MCB ,415V, C curve
1 No.Danger Board.
Main LT Panel :
Incoming
Incomer:
2Nos. 250A, 4P, 36kA MP based MCCB with over current, short circuit earth fault release. Each feeder consists of 3Nos. 250/5A, 15VA, CL-1 CT operated Multifunction Meter with RS485, 1No. 6A, TP MCB Protected Digital Voltmeter, 1 set of R,Y B,ON,OFF,TRIP indication lamps with all other accessories. with 2nos Type 1+2, 50kA (SPD)
250A 4P AUTOMATIC TRANSFER SWITCHES (ATS)
1No. 250A, 4P, 36kA MP based MCCB with over current, short circuit earth fault release. Each feeder consists of 3Nos. 250/5A, 15VA, CL-1 CT operated Multifunction Meter with RS485, 1No. 6A, TP MCB with R,Y B,ON,OFF,TRIP indication lamps with all other accessories.
Bus Bar:
320A, 36KA for 1Sec, TP+N+E Aluminium Busbar
Outgoing:
2 No. 160A, 4P, 25kA Thermal Magnetic based MCCB with all accessories and protection
1 No. 80A, TPN, 25kA Thermal Magnetic based MCCB with all accessories and protection
4 Nos. 63A, 4P, 10kA MCB
5 Nos. 40A, 4P, 10kA MCB
8 Nos. 32A, 4P, 10kA MCB
Complete Board as stated above.
Part-D(DG Set)
Supply, Erection, Testing & Commissioning of outdoor sound & weather proof type "Diesel Generator-Set" with anti-vibration mounts, fitting, fixing etc. complete in all respect. The rate shall be inclusive of necessary RCC(1:1.5:3) foundation as per design consideration using M-25 grade of concrete and Fe-415 grade of reinforcement steel suitable for installation of DG-set at 300mm above FGL. Prime duty DG sets with heat exchanger cooled version, with CPCB-IV+ approved acoustic enclosure for outdoor application. Sound level of DG set shall not be more than 75dBA at 01 meter from sound proof canopy. The DG-Set should be provided with following accessories,
DG-SET RATING : 140KVA
MAKE OF ALTERNATOR : ASHOK LEYLAND /KIRLOSKAR/CROMPTON GREAVES/ CUMMINS. STAMFORD/ LEROY SOMER as per direction of EIC.
1500RPM,4-STROKE TURBO CHARGED AFTER COOLED DIESEL ENGINE OF SUITABLE CAPACITY & RATED BHP TO DELIVER THE SPECIFIED LOAD AT NTP COMPLETE WITH STANDARD ACCESSORIES AND SHALL CONFORMING TO ISO:3046,BS:5514.
THE ENGINE IS TO BE ELECTRICALLY STARTED BY AN ELECTRICALLY DRIVEN SELF STARTER OPERATED THROUGH ENGINE BATTERY.
ENGINE LOCAL CONTROL PANEL WITH EQUIPMENTS AND INSTRUMENTS MOUNTED ON THE ENGINE FRAME COMPLETE.
LEAD ACID TYPE HEAVY DUTY STARTING BATTERIES WITH SELF DRIVEN CHARGER UNIT.
RADIATOR OF THE ENGINE WITH SELF DRIVEN FAN AND INNER CIRCUIT WATER PUMPS COMPLETE.
GEAR TYPE LUBE OIL PUMPS, LUBRICATING OIL FILTER, LUBE OIL CENTRIFUGE AND LUBRICATING OIL COOLER
FUEL INJECTION SYSTEM WITH INJECTION PUMP, FUEL FILTER, FUEL PREFILTER AND NOZZLES GOVERNOR ETC.
AMF PANEL
Cubical type floor mounted AMF panel made from 16 SWG Sheet Steel, duly pretreated, powder coated painted and aesthetically finished, suitable for controlling of 140 KVA DG set having following specification:
i) 320A 36 KA MCCB with 0/L, S/C, E/F protection and microprocessor based protection release , UN release etc -
ii)In Built By-Pass switch for rated capacity
iii)On -delay timer for load change over
iv)On-delay timer for engine shut off
v)Engine On-Off switch (Push button type)
vii)Minimum five number indicating lamps to indicate 'mains ON', 'load on mains', Set running', 'load on set' and 'battery charger on'.
viii)Audio visual alarm for 'Low lubricating oil pressure', 'High water temperature, Start failure', and DG over load'.
x)Microprocessor based relay with composite meter for digital display of following.
Generator voltage/AC Mains voltage.
Generator Current in all phases
Frequency
Power Factor
Energy
Indication for alternator supply
Running time indications number of hours of operation and service intervals, service due indications
The AMF panel must be designed to ensure trouble free performance and ensure switching over Electrical Load to DG within 15 (fifteen) second from the instant of mains failure
Complete Board as stated above.
Supply & Laying of "1.1kV grade "Cu. Armoured Control Cable" including terminations as required. The rate shall be inclusive of necessary supporting & clamping arrangement for laying of cables within tray/pipe/trench. The installation shall confirm IS : 1255.1983 & amended upto date.
Supply of 1.1KV 8Cx2.5sqmm XLPE Armoured CU. Cable .
Supply of 1.1KV 12Cx2.5sqmm XLPE Armoured CU. Cable .
Extending the exhaust pipe with 100 mm. dia MS black pipe (Thickness 4 mm) including connection with the existing silencer attached with the flexible coupler and S&F flange, nuts, bolts & washers etc. & necessary fixing materials etc. as required from DG set upto 2.5 Mts high of the near higher installation with Asbestos rope / glass wool insulation and chicken net and Aluminium fol covering, with end cap with high temperature painting (NS)
Making insulation by 2" glass wool including netting arrangement and covered with aluminium daring as per direction of the EIC.
a)100 mm. dia exhaust pipe
b)Residential type silenser pipe
S&F special type MS angle iron bracket support made of 40x40x6 mm. MS angle with flat iron clamp with nuts. bolts & washers etc. for 90 mm. dia (Vertical Run)
S&F rain protection canopy.
Filling of HSD oil for initial refill with transportationThS1
Part-E(UPS Power Supply)
Supply, Installation, Testing and commissioning of 30kVA Online UPS with 30 minutes backup, True online double convertion confirming (VFI-SS-III); can be parallel in (N+ 1) configuration minimum 4 nos
Input
Nominal Voltage- 380/400/415 Vac3Ph +N+PE
Operating Voltage Range - 320 – 476
Input Voltage Range for 100% - '-20/+20 % @ full load (320-476V)
Input Voltage Range for 50% load - ' - 35% @ 50% load (260-476V)
Operating Frequency Range - 45-55 Hz
Power Factor - Unity
Bypass Frequency Range - ± 10%
Harmonic distortion (THDi) - ≤ 3% at rated load
Input auto phase sequence correction - Inbuilt
Output
Output Voltage - 380/400/415 Vac 3Ph +N+PE
Power Factor - Unity
Voltage Regulation - ± 1% (balanced load)
Frequency (Online Mode) - 50Hz ± 10% (with sync mode & adjustable)
Frequency (Battery Mode) - 50Hz ± 0.1 Hz
Harmonic distortion (THDv) - ≤ 2% with Linear Load ≤ 5% with Non-linear load
Isolation Transformer - should be Inbuilt
Crest Factor - 03:01:00
Cold Start - Must available
Overload - ≤ 110% for 60min ≤ 125% for 10min ≤150% for 60 Sec
Efficiency - 94%
Communication
Standard - LCD Display, LED Indication, RS232 port, RS485 port, Dry Contact
Remote monitoring
BMS compatibility
Remote shutdown
Environment
Operating Temperature for UPS - 0 degree C – 40 degree C
Relative Humidity Range - 0-95 % (non-condensing)
Noise Level - Max 65Dba at 100% load and ≤55Dba at 50%
Standards
IEC 6240-1 , IEC6240-2 , IEC6240-3 , CE, ROHS & PEP
BATTERY
Battery Make - Exide/Quanta/Leoch
Battery Type - SMF battery
Minimum Battery VAH - 34272
Charger Capacity for UPS - Long backup charger ( at least upto 20Amps)
Complete set as stated above
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .