Tender Value
Refer Docs
EMD Value
₹6,038
Closing Date
28 Jul 2026, 4:00 pm3d left
ASSISTANT EXECUTIVE ENGINEER,
O/o ASSISTANT EXECUTIVE ENGINEER, PWD ELECTRICAL SUB DIVISION, IDUKKI, PAINAVU P.O, PAINAVU-685603
Running Maintenance Contract of Electrical installation at Muttom Adimaly Devikulam Peermedu Court complex
2025_PWD_819444_4
PWD/BLDG/TR/18791/2025_6_1_1/2
Open Tender
Electrical Works
Percentage
365 days
muttom, Adimaly, devikulam, peerumadu
Please refer Tender documents.
10 documents required · 10 mandatory
₹555
₹6,038
18 Jul 2026
18 Jul 2026
30 Jul 2026
18 Jul 2026
28 Jul 2026
18 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1RMC works | |||||
| 1.001 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C | - | point | 1,689.22 | - |
| 1.002 | OD175693/2025-2026:Dismantling existing ordinary type tube fitting from RB/Chain/Stiff and Supply, Conveyance, Installation, Testing and Commissioning of 1x18W LED pre-wired G13 base Box type single tube light fitting made of CRCA sheet of minimum 0.5mm thickness with powder coated whole body complete with all accessories like wiring, end cap, side holer , knockout etc including single piece LED tube light having the following specification: Double side pin type single piece indoor LED Tube poly carbonate body (cool white at 6500 K temprature ) 1200 mm, T8 I, 18 w with nominal system level lumen pakage of 2100 Lumen, having effiency of minimum 115 lumen/watt, Inbuilt Driver with THD <10%, power factor > 0.95, RoHS compliant, suitable for use 140~280V AC 50 HZ AC supply. The light shall be made by Polycarbonate housing (IP20 protection) with minimum 3 KV surge protection. . The light should have minimum 70% of light at 40000 Hr life time as per LM 79 NABL Accreditation certification. LED used in this light should be from manufacturer of Lumileds/Osram/Cree/Nichia make. Fittings fixed directly on wall or ceiling with existing round block or existing Stiff and giving connection with existing length of 16/0.20mm 3 core copper conductor flex wire and giving connections as required. | - | each | 1,003.88 | - |
| 1.003 | OD199176/2025-2026:Supply, and fixing of cast aluminum bulk head fitting with mesh guard giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. | - | each | 601.37 | - |
| 1.004 | OD175699/2025-2026:Supply and filling of Distilled/Deionized Lead acid battery water (5 Litre Bottle) | - | each | 235.9 | - |
| 1.005 | OD175691/2025-2026:Supply, conveyance, installation, testing and commissioning of 300/305 mm sweep Light Duty Exhaust fan in metal frame working on 230 V A/C in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS. | - | each | 1,706.59 | - |
| 1.006 | OD175704/2025-2026:Dismantling existing ordinary type tube/choke from fittings and Supply, Conveyance, Installation, Testing and Commissioning of 1x18W LED pre-wired G13 base with extruded LED Tube poly carbonate body (cool white at 6500 K temprature ) 1200 mm, T8 I, 18 w with nominal system level lumen pakage of 2100 Lumen having efficiency of minimum 115 lumen/watt, Inbuilt Driver with THD <10%, power factor >0.95, RoHS compliant, suitable for use 140~280V AC 50 HZ AC supply. The light shall be made by Polycarbonate housing (IP20 protection) with minimum 3 KV surge protection. . The light should have minimum 70% of light at 40000 Hr life time as per LM 79 NABL Accreditation certification. LED used in this light should be from manufacturer of Lumileds/Osram/Cree/Nichia make. | - | each | 567.04 | - |
| 1.007 | 1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. | - | each | 99.8 | - |
| 1.008 | 1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required. | - | each | 126.42 | - |
| 1.009 | 1.59:Dismantling of ceiling fan and painting the same with with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins reinstalling the same as required. | - | each | 300.54 | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.27 MB
BOQ_1456355.xls
BOQ • 0.37 MB
NIT.pdf
Tender Documents • 0.02 MB
SBD.pdf
Tender Documents • 1.64 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].