| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹14.6 LAccepted-AOC 203 NABIL APARTMENT ASHOK NAGAR OPP HATHIKHANA ANAJ MARKET TULSIWADI ROAD KARELIBAUG VADODARA 390018 GUJARAT | VADODARA | GUJARAT | 390018 | ₹14.6 L Quoted ₹15.0 L | L-1 | Accepted-AOC Lowest |
| 2 | L-2₹16.2 L+₹1.3 L (8.42%)Rejected-Finance HOUSE NO 120 1 NEAR HANUMAN MANDIR AT POST SHEL PIMPALGAON TAL KHED DIST PUNE PIN 411014 | PUNE | MAHARASHTRA | 411014 | ₹16.2 L+₹1.3 L (8.42%) | L-2 | Rejected-Finance Due to not lowest |
| Sl No | Description | Qty | Unit | NILESH SUBHASH KARALE L2 | FAIZA ENTERPRISE L1 |
|---|---|---|---|---|---|
| 1.00 | Material and labour for spot cheking serviceability of ceiling fan, exhaust fan, wall mounted fan,pedestal fan,and ensure all accessories like splite pin,fan hook,rubber,clamps nut and bolt,down rod etc and refixing the appliances after the checking/servicing or replacement of accessories,as required complete all as specified and directed. Note:-
(i) The work shall be carried out in occupied quarters and the part(split pin,fan hook, rubber bush) replace will be deemed under quoted rates. (ii) The work shall be carried on specific numbered docket issued by Engr-in-Charge/JE and after checking of servicability/repair,contractor shall obtained the sign of the user and return the docket for payment action.
(iii) All tools and plants required for the work shall be arrange by the contractor. | 2,400 | EACH JOB | 77 ₹1,84,800 | 50 ₹1,20,000 Lowest |
| 2.00 | Taking down ceiling fan/Exhaust fan /wall monted fan/pedestal fan of any make and sweep,cleaning externally and internally. Stripping out the fans, examine the unserviceable spares/ burnt winding by testing, cleaning and lubricating bush/ bearings. Refixing the fans in same position after necessary repairs/ servicing including carring out the replacement worn out parts, body covers, screws, spilt pins nuts condensor and flexible wire copper conducter from ceiling fan to ceiling rose etc complete all as specified and as directed. Note:
(i) The parts replaced will be measured under relevant item as "Supply Only" (ii) All tools and plants required for the work shall be arrange by the contractor. | 1,150 | EACH | 190 ₹2,18,500 Lowest | 225 ₹2,58,750 |
| 3.00 | Removing defective winding and rewinding with new super enamelled copper wire of existing gauge and weight as per manufactures design and instructions including insulating materials and varnishing of ceiling fans/flame proof ceiling fan of size 1200/ 1400mm sweap of any make and re-assembling testing including replacement of shaft, repairs/replacement of BLDC PCB as per existing type and model complete and refixing to the location including replacement of flexible copper wire from ceiling rose to ceiling fan complete all as specified and directed. | 850 | EACH | 625 ₹5,31,250 | 610 ₹5,18,500 Lowest |
| 4.00 | All as per serial item number 3.00 here-in-before but exhaust fan/flame proof exhaust fan of size 300/380 mm sweep. | 200 | EACH | 1,000 ₹2,00,000 | 900 ₹1,80,000 Lowest |
| 5.00 | All as per serial item number 3.00 here-in-before but exhaust fan/flame proof exhaust fan of size 400/450 mm sweep. | 50 | EACH | 1,150 ₹57,500 | 980 ₹49,000 Lowest |
| 6.00 | All as per serial item number 3.00 here-in-before but pedestal/Wall mounted/Air circulator fan of size 400/450/600 mm sweep. | 50 | EACH | 1,080 ₹54,000 | 900 ₹45,000 Lowest |
| 7.00 | Supply and fix rubber bush for shackle with bolt, nut and lock pin suitable for Ceiling fan 1200mm / 1400mm sweep complete all as specified and directed. | 150 | EACH | 18 ₹2,700 Lowest | 25 ₹3,750 |
| 8.00 | Supply only following spare parts of ceiling fan of 1200mm / 1400mm sweep,exhaust/wallmounted fans of different make required as per the makes of existing fans as required at site or in winding shop complete all as specified and directed:- | - | - | - | - |
| 9.00 | PVC holder for condenser housing. | 300 | EACH | 13 ₹3,900 Lowest | 15 ₹4,500 |
| 10.00 | Split Pin | 300 | EACH | 0.1 ₹30 Lowest | 1 ₹300 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
29 Nov 2025, 6:00 pmClosed
Garrison Engineer (AF) Naliya No. 1
GE AIR FORCE STATION NALIYA NO 01
REPAIR/REPLACEMENT OF CEILING FAN, EXHAUST FAN, WALL FAN, PEDESTAL FAN AT DOMESTIC AND TECHNICAL AREA AT AF STN NALIYA
2025_MES_739020_1
8076/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Air Force Station Naliya
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE(AF) Naliya No. 1
₹30,000
Yes
20 Mar 2026
8 Nov 2025
1 Dec 2025
8 Nov 2025
29 Nov 2025
22 Nov 2025
Material and labour for spot cheking serviceability of ceiling fan, exhaust fan, wall mounted fan,pedestal fan,and ensure all accessories like splite pin,fan hook,rubber,clamps nut and bolt,down rod etc and refixing the appliances after the checking/servicing or replacement of accessories,as required complete all as specified and directed. Note:- (i) The work shall be carried out in occupied quarters and the part(split pin,fan hook, rubber bush) replace will be deemed under quoted rates. (ii) The work shall be carried on specific numbered docket issued by Engr-in-Charge/JE and after checking of servicability/repair,contractor shall obtained the sign of the user and return the docket for payment action. (iii) All tools and plants required for the work shall be arrange by the contractor.
Taking down ceiling fan/Exhaust fan /wall monted fan/pedestal fan of any make and sweep,cleaning externally and internally. Stripping out the fans, examine the unserviceable spares/ burnt winding by testing, cleaning and lubricating bush/ bearings. Refixing the fans in same position after necessary repairs/ servicing including carring out the replacement worn out parts, body covers, screws, spilt pins nuts condensor and flexible wire copper conducter from ceiling fan to ceiling rose etc complete all as specified and as directed. Note: (i) The parts replaced will be measured under relevant item as "Supply Only" (ii) All tools and plants required for the work shall be arrange by the contractor.
Removing defective winding and rewinding with new super enamelled copper wire of existing gauge and weight as per manufactures design and instructions including insulating materials and varnishing of ceiling fans/flame proof ceiling fan of of size 1200/ 1400mm sweap of any make and re-assembling testing complete and refixing to the location including replacement of flexible copper wire from ceiling rose to ceiling fan complete all as specified and directed.
All as per serial item number 3.00 here-in-before but exhaust fan/flame proof exhaust fan of size 300/380 mm sweep.
All as per serial item number 3.00 here-in-before but exhaust fan/flame proof exhaust fan of size 400/450 mm sweep.
Supply and fix rubber bush for shackle with bolt, nut and lock pin suitable for Ceiling fan 1200mm / 1400mm sweep complete all as specified and directed.
Supply only following spare parts of ceiling fan of 1200mm / 1400mm sweep,exhaust/wallmounted fans of different make required as per the makes of existing fans as required at site or in winding shop complete all as specified and directed:-
PVC holder for condenser housing.
Split Pin
Ball bearing of size No 6201/6202/6203
Gun metal bush as per sample.
Supply and fix Condenser (capacitor) 2.5 MFD, 440 Volts, AC 50 Hz as per IS 1709 suitable for ceiling fan 1200/1400 mm sweep complete all as specified and directed.
Supply and fix Condenser (capacitor) 3.15 MFD, 440 Volts, AC 50 Hz as per IS 1709 suitable for ceiling fan 1200/1400 mm sweep complete all as specified and directed.
Supply and fix Condenser 4 MFD, 440 Volts, AC 50 Hz as per IS 1709 suitable for exhaust fan 300/380/450 mm sweep complete all as specified and directed.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
Tender8076.pdf
Tender Documents • 0.82 MB
BOQ_827499.xls
BOQ • 0.98 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .