Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.8 LAccepted-AOC DOOR NO 15 1 141 BHAVANA ENCLAVE 1 NEAR HOTEL GRAND BAY MAHARANIPETA NOWAROJI ROAD VISAKHAPATNAM 530002 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530002 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹25.9 L+₹3.1 L (13.8%)Rejected-Finance | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹26.7 L+₹3.9 L (17.3%)Rejected-Finance 45 38 15 JAGANNADHAPURAM VISAKHAPATNAM 530 016 | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹27.4 L+₹4.6 L (20.2%)Rejected-Finance | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹28.2 L+₹5.4 L (23.8%)Rejected-Finance D NO 35 14 13 1 R P PETA KANCHARAPALEM VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | L5 | Rejected-Finance Being not L1 |
Tender Value
₹41.5 L
EMD Value
₹83,000
Closing Date
14 May 2020, 6:00 pmClosed
Garrison Engineer Utility-I Visakhapatnam
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
MANNING AND OPERATION AND MAINTENANCE OF HT 11 KV/ LT SUB STN, LT PANELS AT MWC, FLEET OFFICE, TPW, SMHQ, FMU, KUTHAR BLOCK AND CERTAIN MISC WORKS UNDER AGE E/M-I OF GE (U-I) VISAKHAPATNAM
2020_MES_338540_1
8211/E8
Open Tender
Electrical Maintenance Service
Item Rate
330 days
Garrison Engineer Utility-I Visakhapatnam
CLASS D
9 documents required · 9 mandatory
₹500
Garrison Engineer Utility-I
₹83,000
Yes
14 Jul 2020
11 Apr 2020
16 May 2020
11 Apr 2020
14 May 2020
1 May 2020
Amount
Out sourcing to the operation maintenance of HT 11 KV/ LT sub station round the clock in three shifts of 08 hours each for smooth and trouble free operation to the installations all are specified and directed by Engineer-in-charge at MWC (V)
Outsourcing :- One Skilled electrician and One Semi Skilled Electrician per shift of 08 hours
Details of equipments:
HT OCBs-04Nos
Transformer 630 KVA-01 No
Transformer - 100 KVA -01 No
LT Panel -02 Nos
The contractor is responsible for the minor repairs/ maintenance to the OCBs, LT panels under the out sourcing
The contractor is responsible for the cleaning of all indoor substn under this out sourcing
The operators should be liaise with Naval dockyard 11 sub station, 21 sub station, work shop sub station for any major break down/ failure of electric supply
In case any problem occurs which seems not under the control of operator, the same shall be immediately intimated to JE I/c of this area or AGE E/M.
The operator on duty shall be in uniform as directed by Engineer-in-charge / GE.
Out sourcing to the operation maintenance of HT 11 KV/ LT sub station in two shifts per day including Sundays and Holidays (From 0900 Hrs to 1700 Hrs) one shift of 08 hours each for smooth and trouble free operation to the installations all are specified and directed by Engineer-in-charge at TPW 09 Bldg, 08 Bldg, 551/552 Bldg, STS Bldg.
Outsourcing :- One Skilled electrician and One Semi Skilled Electrician per shift of 08 hours
Details of equipments:
551/552 substation
HT VCBs-08Nos
Transformer 750 KVA-02 No
LT Panel -02 Nos
STS substation
HT VCB-01No
Transformer 250 KVA-01 No
LT Panel -01 Nos
08 Bldg substation
HT VCB-01No
Transformer 315 KVA-02 Nos
LT Panel -02 Nos
09 Bldg S/Stn
HT VCB - 02 Nos
Transformer
LT Panel -01 No
The contractor is responsible for the minor repairs/ maintenance to the VCBs, LT panels, HT structures under the out sourcing
The contractor is responsible for the cleaning of all indoor substn under this out sourcing
The operators should be liaise with Naval dockyard sub station for any major break down/ failure of electric supply
In case any problem occurs which seems not under the control of operator, the same shall be immediately intimated to JE I/C of this area or AGE E/M.
The operator on duty shall be in uniform as directed by Engineer-in-charge / GE.
Out sourcing to the operation maintenance of HT 11 KV/ LT sub station in two shifts per day including Sundays and Holidays (From 0900 Hrs to 1700 Hrs) One shift of 08 hours each for smooth and trouble free operation to the installations all are specified and directed by Engineer-in-charge at FMU, SMHQ, Fleet Office SubStn.
Outsourcing :- One Skilled Electrician per shift of 08 hours
Details of equipments:
Fleet Maint Unit
LT Panel -02 Nos
LT Panel -01 No
Fleet Office
LT Panel -01 No
Kuthar Block
LT Panel -01 No
The contractor is responsible for the minor repairs/ maintenance to the LT panels under the out sourcing
The contractor is reponsible for the cleaning of all indoorsubstn under this out sourcing
The operators should be liaise with Naval dockyard sub station for any major break down/ failure of electric supply
In case any problem occurs which seems not under the control of operator, the same shall be immediately intimated to JE I/C of this area or AGE E/M.
The operator on duty shall be in uniform as directed by Engineer-in-charge / GE.
Earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion
All as per Item No 04, but using galvanised iron strip 32×6mm as earthing lead complete all as directed.
Supply& fix aluminium strip 25mmx 6 mm coplete wiyh saddles and fixing screws for fitting the strip
Supply and fix rubber mat of 1Mtr X 2 Mtr X 19 MM thick complete all as directed
Excavating in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for foundation, trenches for laying cables/ pipe line etc. and getting out in soft/loose soil
Removing excavated materials to a distance n. exc. 50m and depositing where directed at a level n. exc 1.50m above the starting point.
Returning, filling in including spreading leveling watering and well ramming in layers not exc 25cm in any type of soil.
Supply and spreading clean dry sand for cable cushioning in trenches complete all as specified and as directed. (Note: Punned thickness only shall be measured)
Supply and laying sub class 'B' bricks of old size (23x11x7cm) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
Cutting & Cleaning of bushes/small plants, at sub stn incl surface dressing and removing debris to distance not exc 50 mtr complete
M & L for painting of surface of any description over 10 cm in width using synthetic enamel paint of one coat by using brush or cloth after preparation of old painted surfaces complete all as directed
M &L Plain cement concrete 1:4:8 type C2 (using 40 mm aggregrate) as in foundations filling mass concrete complete all as specified and directed
M &L for cement concrete PCC 1:2:4 type B1 (using 20 mm aggregrate) as coping of poles complete all as specified and directed
Supply and fix or laid in road crossing/ fixed to poles, GI Pipe of 80 MM size light grade for protection of cable complete all as directed
Supply and fix or laid in road crossing/ fixed to poles, GI Pipe of 100 MM size light grade for protection of cable complete all as directed
Making trench through horizontal earth Boaring for road/ foot path /hard standing/culvert etc for inserting GI protection pipe for drawing of cable and complete all as directed.
Cutting trench through road/ wall to a width of 20cm and depth of 30cm for inserting GI protection pipe for drawing cable and filling back the trench with PCC 1:3:6 type C1 complete all as directed.
M&L for detecting HT/LT UG cable faults located in any stretch / depth with cable fault locator consisting of microprocessor based, identification instrument, cable tracer for exact location of under ground cable routes. Notes:- The rate quoted deemed to be inclusive of rental charges for T&P like entire cable fault locating instrument, charges for operator and transportation etc complete.
Supply and laying or fixing or passing through pipe or in cable ducts, 11000 volts grade XLPE insulated Heavy duty (earthed),screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor 185 sq mm 3 core size including dismantling old one. Make : Havells/ KEI/ Polycab.
Supply and laying or fixing or passing through pipe or in cable ducts, 11000 volts grade XLPE insulated Heavy duty (earthed),screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor 240 sq mm 3 core size including dismantling old one. Make : Havells/ KEI/ Polycab.
Supply and laying or fixing or passing through pipe or in cable ducts, 1100 volts grade XLPE insulated Heavy duty (earthed),screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor 400 sq mm 3.5 core size including dismantling old one. Make : Havells/KEI/Polycab.
Supply and laying or fixing or passing through pipe or in cable ducts, 1100 volts grade XLPE insulated Heavy duty (earthed),screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor 300 sq mm 3.5 core size including dismantling old one. Make : Havells / KEI /Polycab.
Supply and laying or fixing or passing through pipe or in cable ducts, 1100 volts grade XLPE insulated Heavy duty (earthed),screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor 240 sq mm 3.5 core size including dismantling old one. Make: Havells / KEI /Polycab..
Supply and fix cable jointing kit for 11 KV grade cable for outdoor terimination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conducter cable of size 240 sq mm. Make: Birla 3M/ Raychem/ Denson
Supply and fix cable jointing kit for 11 KV grade cable for indoor terimination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conducter cable of size 240 sq mm. Make: Birla 3M/ Raychem/ Denson
Supply and fix cable jointing kit for 11 KV grade cable for outdoor terimination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conducter cable of size 185 sq mm. Make: Birla 3M/ Raychem/ Denson
Supply and fix cable jointing kit for 11 KV grade cable for straight through outdoor heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conducter cable of size 185 sq mm. Make: Birla 3M/ Raychem/ Denson
Supply and fix cable jointing kit for 11 KV grade cable for indoor terimination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conducter cable of size 185 sq mm. Make: Birla 3M/ Raychem/ Denson
Supply and replace MCCB 3 pole, 415 V, adjustable type 630Amps with breaking capacity 36 KA including necessary modification in the panel complete all as specified and as directed. Make: L&T/Havells/Legrand
Supply and replace MCCB 3 pole, 415 V, adjustable type 400Amps with breaking capacity 36 KA including necessary modification in the panel complete all as specified and as directed. Make: L&T/Havells/Legrand
Supply and replace MCCB 3 pole, 415 V, adjustable type 250 Amps with breaking capacity 36 KA including necessary modification in the panel complete all as specified and as directed. Make: L&T/Havells/Legrand
Supply and replace MCCB 3 pole, 415 V, adjustable type 160 Amps with breaking capacity 36 KA including necessary modification in the panel complete all as specified and as directed. Make: L&T/Havells/Legrand
Disconnecting IED of any type/Make from 11kV HT panel, cleaning the contacts , IED configuration , Calibration & Testing of all the measuring & protection devices viz., CTs, Relays and Meters at site. Testing of all the trip functions of the relays after final current settings by simulating fault current by CT secondary injection test set , checking of current transformer , rectification of defects in control wiring for proper tripping of CB during actual system fault conduction through relay & Tripping coil. Adjustment / setting to plug and time multiplier settings of IED to achieve the discrimination in tripping , tune/synchronies upstream breaker relay settings, testing & commissioning.... etc complete all as specified and as directed.
Decarburizing/cleaning complete 11kV HT Bus bar chamber with electrical connections, complete bus bar from the bus bar chamber , Cleaning with CTC and ensure proper decarburizing up to proper megger value , refixing the same after applying Backtol Red solution to the bus bar insulator & checking all the connections , tightening the nuts , bolts complete incl replacement of defective rusted bolts & nuts all as specified and directed.
M/s NATIONAL ENGINEERING CONSTRUCTIONS CO
SAI SAMPATH ELECTRICAL AND ENGINEERING
M/s Sri vinayaka Infra
M/S CHANDRA ENGINEERS AND CONTRACTORS
M/s SS Engineering Enterprises
AYYAPPA CONSTRUCTIONS
Sri Surya Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .