Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹99.6 LAdmitted-Finance | ₹99.6 L | L1 | Admitted-Finance |
| 2 | L2₹1.2 Cr+₹17.5 L (17.6%)Admitted-Finance 7 CANAL VIEW GIANI ZAIL SINGH NAGAR RUPNAGAR PUNJAB 140001 INDIA | RUPNAGAR | PUNJAB | 140001 | ₹1.2 Cr+₹17.5 L (17.6%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical BEEHAMA GANDERBAL SHEIKH ENGINEERS AND CO BEEHAMA GANDERBAL GANDERBAL GANDERBAL JAMMU KASHMIR 191201 | GANDERBAL | JAMMU AND KASHMIR | 191201 | - | - | Rejected-Technical Some documents missing |
| Sl No | Description | Qty | Unit | Shivalik Hydro Pvt.Ltd L2 | PENTEX ENGINEERS AND SUPPLIERS L1 |
|---|---|---|---|---|---|
| 1.00 | Supply, Installation, testing and Commissioning of Duplex Strainers (Manual Cleaning) with 14 Inch inlet, outlet and working pressure of 10 Bars along with valves to control & direct the water flow though either one or both channel. Filtration of 2000 Microns. | 1 | job | 28,32,000 ₹28,32,000 | 24,06,250 ₹24,06,250 Lowest |
| 2.00 | Supply, Installation, testing and Commissioning of Duplex Strainers (Auto Self-Cleaning) with 14 Inch inlet, outlet and working pressure of 10 Bars along with valves to control & direct the water flow though either one or both channel. Filtration of 2000 Microns | 1 | job | 32,82,000 ₹32,82,000 | 10,67,000 ₹10,67,000 Lowest |
| 3.00 | Supply, Design, Installation, testing and Commissioning of 14 Inch Seamless pipeline (in Metres). SCH 40, Thickness- 11 mm, confirming to ASTM A106 Gr.B | 1 | job | 1,08,000 ₹1,08,000 Lowest | 16,23,270 ₹16,23,270 |
| 4.00 | Supply, Installation, testing and Commissioning of SCADA compatible motorised AUTO Open/ Close Gate Valves – 14 inch in the main Penstock tapping input with following specifications as per site & Design requirement: Material: CS. Working Pressure: 6 Bars, Designed Pressure: 25 Bars, ANSI standard according to designed pressure, Class: 300 or higher | 1 | job | 10,89,989 ₹10,89,989 | 6,93,000 ₹6,93,000 Lowest |
| 5.00 | Supply, Installation, testing and Commissioning of SCADA compatible motorised MANUAL Open/ Close Gate Valves – 14 inch in the main Penstock tapping input with following specifications as per site & Design requirement: Material: CS. Working Pressure: 6 Bars, Designed Pressure: 25 Bars, ANSI standard according to designed pressure, Class: 300 or higher | 1 | job | 8,78,789 ₹8,78,789 | 4,95,000 ₹4,95,000 Lowest |
| 6.00 | Supply, Installation, testing and Commissioning of Gate Valves – 14 inch in the main 14 inch pipeline with following specifications as per site & Design requirement: Material: CS. Working Pressure: 6 Bars, Designed Pressure: 20 Bars, ANSI standard according to designed pressure, Class: 150 or higher | 1 | job | 2,00,000 ₹2,00,000 Lowest | 11,26,125 ₹11,26,125 |
| 7.00 | Supply, Installation, testing and Commissioning of Non Return Valves – 14 inch in the with following specifications as per site & Design requirement: Material: CS. Working Pressure: 6 Bars, Designed Pressure: 20 Bars, ANSI standard according to designed pressure, Class: 150 or higher | 1 | job | 3,00,000 ₹3,00,000 Lowest | 4,82,625 ₹4,82,625 |
| 8.00 | Supply, Installation, testing and Commissioning of 10 inch seamless pipeline in the individual unit header (in metres)- SCH 40, Thickness- 9mm, confirming to ASTM A106 Gr.B | 1 | job | 87,897 ₹87,897 Lowest | 6,18,750 ₹6,18,750 |
| 9.00 | Supply, Installation, testing and Commissioning of 10 Inch control Gate valves- 03 NO. with following specifications as per site requirement: Material: CS. Working Pressure: 6 Bars, Designed Pressure: 20 Bars, ANSI standard according to designed pressure, Class: 150 or higher | 1 | job | 89,848 ₹89,848 Lowest | 2,60,233 ₹2,60,233 |
| 10.00 | Supply, Installation, testing and Commissioning of flow meters and relays at different locations to transmit the flow data and low flow alarms to SCADA in Control Room | 1 | job | 98,999 ₹98,999 Lowest | 1,78,200 ₹1,78,200 |
Tender Value
₹1.3 Cr
EMD Value
₹2.6 L
Closing Date
28 Apr 2026, 4:00 pmClosed
Executive Engineer
Executive Engineer GD LJHP
Replacement of existing duplex strainers of the cooling system with modern duplex strainers and SCADA compatibility along with disposal mechanism
2026_SPDC_307429_1
NIT no. 01 of 2026-27 dated 06-04-2026
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
150 days
Gantmulla Baramulla
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
Yes
Chief Pay And Accounts Officer Baramulla
₹2.6 L
Online
8 Jun 2026
7 Apr 2026
30 Apr 2026
7 Apr 2026
28 Apr 2026
13 Apr 2026
13 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation, testing and Commissioning of Duplex Strainers (Manual Cleaning) with 14 Inch inlet, outlet and working pressure of 10 Bars along with valves to control & direct the water flow though either one or both channel. Filtration of 2000 Microns. | - | job | - | - |
| 2 | Supply, Installation, testing and Commissioning of Duplex Strainers (Auto Self-Cleaning) with 14 Inch inlet, outlet and working pressure of 10 Bars along with valves to control & direct the water flow though either one or both channel. Filtration of 2000 Microns | - | job | - | - |
| 3 | Supply, Design, Installation, testing and Commissioning of 14 Inch Seamless pipeline (in Metres). SCH 40, Thickness- 11 mm, confirming to ASTM A106 Gr.B | - | job | - | - |
| 4 | Supply, Installation, testing and Commissioning of SCADA compatible motorised AUTO Open/ Close Gate Valves – 14 inch in the main Penstock tapping input with following specifications as per site & Design requirement: Material: CS. Working Pressure: 6 Bars, Designed Pressure: 25 Bars, ANSI standard according to designed pressure, Class: 300 or higher | - | job | - | - |
| 5 | Supply, Installation, testing and Commissioning of SCADA compatible motorised MANUAL Open/ Close Gate Valves – 14 inch in the main Penstock tapping input with following specifications as per site & Design requirement: Material: CS. Working Pressure: 6 Bars, Designed Pressure: 25 Bars, ANSI standard according to designed pressure, Class: 300 or higher | - | job | - | - |
| 6 | Supply, Installation, testing and Commissioning of Gate Valves – 14 inch in the main 14 inch pipeline with following specifications as per site & Design requirement: Material: CS. Working Pressure: 6 Bars, Designed Pressure: 20 Bars, ANSI standard according to designed pressure, Class: 150 or higher | - | job | - | - |
| 7 | Supply, Installation, testing and Commissioning of Non Return Valves – 14 inch in the with following specifications as per site & Design requirement: Material: CS. Working Pressure: 6 Bars, Designed Pressure: 20 Bars, ANSI standard according to designed pressure, Class: 150 or higher | - | job | - | - |
| 8 | Supply, Installation, testing and Commissioning of 10 inch seamless pipeline in the individual unit header (in metres)- SCH 40, Thickness- 9mm, confirming to ASTM A106 Gr.B | - | job | - | - |
| 9 | Supply, Installation, testing and Commissioning of 10 Inch control Gate valves- 03 NO. with following specifications as per site requirement: Material: CS. Working Pressure: 6 Bars, Designed Pressure: 20 Bars, ANSI standard according to designed pressure, Class: 150 or higher | - | job | - | - |
| 10 | Supply, Installation, testing and Commissioning of flow meters and relays at different locations to transmit the flow data and low flow alarms to SCADA in Control Room | - | job | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
TDforreplacementofduplextrainers.pdf
Tender Documents • 0.76 MB
BOQ_997404.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .