Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical As per TEC |
| 2 | Accepted-Technical | Accepted-Technical As per TEC |
| 3 | Accepted-Technical | Accepted-Technical As per TEC |
| 4 | Rejected-Technical | Rejected-Technical As per TEC |
Tender Value
₹14.9 L
EMD Value
₹30,000
Closing Date
2 Sept 2026, 3:00 pmClosed
S Manibala
RO AMARAVATHI
Supplying Fixing of street lights in the warehouse campus at CW Nidamanuru
2026_CWC_289083_1
CWC/RO-Engg. /AMRVT/26-27/NIT.07
Open Tender
Electrical Works
Works
45 days
NIDAMANURU
Please refer Tender documents.
7 documents required · 7 mandatory
₹590
Central Warehousing Corporation
₹30,000
8 Oct 2026
27 Aug 2026
3 Sept 2026
27 Aug 2026
2 Sept 2026
27 Aug 2026
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- All work up to plinth level: 1:1½:3 (1 cement :1 ½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (Main 3 phase DB). (At security post for controlling street lights automatically)-MDB
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A (in Three phase MDB) (INCOMER TO MAIN DB)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(Single pole and neutral) (Main DB outgoings)(To control 2 groups of street lights each)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(Triple pole and neutral) (Main DB outgoings)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.=0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (120 WATTS)
Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (3X1.5)
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63mm dia (OD-63 mm & ID-51 mm nominal)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (25 MM)
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Description
Supply of 6.0 m hot-dip galvanized octagonal pole fabricated in single piece from 3 mm thick HT steel plate for shaft conforming to BSEN-10025 or Equivalent with bottom dia 130 mm, top dia 70 mm, with base plate 220 × 220 × 12 mm, including Galvanizing of Shaft as per IS 2629, along with smart pack terminal box with door size 400 × 100 mm with provision for fixing connector & MCB, and 1.0 m long single-arm bracket, etc., complete with necessary bolts, nuts, cable entry gland, lifting sockets and protective packing, delivered to site.
Supplying and fixing of astronomical digital timer and 25A, with 2 nos. of 4 pole AC contactor inside existing Security Room Main DB for automatic street light control, including all connections, testing and commissioning (At the Main DB feeder of street lights)
SITC of Type 2 SPD with system voltage of 415 V, 4 pole, Nominal discharge current of 20 to 40 kA and Maximum discharge current of 40 to 60 kA
SITC of AmiciSmart 3-Phase Automatic Over/Under Voltage Protector 63A with Over-Current, Phase-Loss & Phase-Imbalance Protection, Auto-Reconnect and Synchronous & Asynchronous Mode (220VAC, White)
Supply & testing of XLPE insulated aluminium conductor steel armoured power cable of 1.1 KV grade confirming to IS :7089 (part 1) 1988 or latest amendment and as per instructions of official-in-charge. 3 X 16 sq. mm.
Supply & testing of XLPE insulated aluminium conductor steel armoured power cable of 1.1 KV grade confirming to IS :7089 (part 1) 1988 or latest amendment and as per instructions of official-in-charge. 3 X 10 sq. mm.
Description
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- All work up to plinth level: 1:1½:3 (1 cement :1 ½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-incharge.
Steel Reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete at alll levels : TMT Bars of Fe grade 500 D or more
Centering and Shuttering including strutting, propping etc. and removal of form for:
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 50 mm dia
Total Amount (in Rs.)
Total Amount (in Rs.)
Total Amount (in Rs.)
Items of works
All Items of Elelctrical works based on DSR Elelctrical 2025
Market Rate-Electrical
All Items of Civil works based on DSR 2023
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.63 MB
NIT07NIDAMANURUPRICEBIDFIANL.xls
Other Document • 0.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .