EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX RAJ BAGH
Revival, Restoration, Preservation and Maintenance of Astan Alya Syed Hussain Qumi RA Architecture N Heritage at Saidpora Zaingeer Baramulla B.W.O Electric work
2026_PWDJK_316539_1
NIT No.82//2026-27 Dt/17/07/2026
Open Tender
Electrical Works
Percentage
Saidpora Zaingeer Baramulla
Please refer Tender documents.
4 documents required · 4 mandatory
₹200
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹10,000
17 Jul 2026
17 Jul 2026
25 Jul 2026
17 Jul 2026
24 Jul 2026
17 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Wiring for Light point/Fan point/Exhaust fan/Bell point with (P+N+E) 3x1.5 sq.mm FRLS-H PVC insulated Multi strand Copper conductor single core cable, (Havells Lifeguard/Polycab Green/Anchor Fireguard/ Apar/ Eq Make) in surface/recessed Conduits laid in slabs (Including Cost of Conduit 25mm) with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified/Schneider Zencelo/ Havells Crabtree/ Legrand Arteor/Anchor roma plus/ABB Tvisha (anti bacterial)/Eq.Make & & items shall be approved before execution of work by SDO. | 48 | Point | 1,189 | ₹57,072 |
| 2 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required,ISO/IEC Certified of Schneider Zencelo/ Havells Crabtree/ Legrand Arteor/Anchor roma plus/ABB Tvisha (anti bacterial)/Eq.Make & shall be approved before execution of work by SDO. | 5 | No. | 402 | ₹2,010 |
| 3 | Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells Lifeguard/Polycab Green/Anchor Fireguard/Apar/ Eq Make) including Copper thimbles for terminating/originating | 120 | Meter | 373 | ₹44,760 |
| 4 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified /Schneider Zencelo/ Havells Crabtree/ Legrand Arteor/Anchor roma plus/ABB Tvisha (anti bacterial)/Eq.Make& shall be approved before execution of work by SDO. | 8 | No. | 659 | ₹5,272 |
| 5 | Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells Lifeguard/ Polycab Green/Anchor Fireguard/Apar/ Eq. Make) | 75 | Meter | 311 | ₹23,325 |
| 6 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Schneider Zencelo/ Havells Crabtree/ Legrand Arteor/Anchor roma plus/ABB Tvisha (anti bacterial)/Eq.Make & shall be approved before execution of work. | 5 | No. | 757 | ₹3,785 |
| 7 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor (Havell Lifeguard/Polycab Green/Anchor Fireguard/Apar/ Eq. make.), single core cable in surface/ recessed medium class PVC conduit as required. | - | - | - | - |
| 8 | 2 X 1.5 sq. mm +1 X1.5 sq. mm earth wire for replacement of old damaged wire | 200 | Metre | 104 | ₹20,800 |
| 9 | 2 X 2.5 sq. mm +1 X 2.5 sq. mm earth wire replacement of old damaged wire | 200 | Metre | 145 | ₹29,000 |
| 10 | Supply/Installation/Testing and Commissioning of 18W + LED recess light (Commerical Type) light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Philips/Havell's/Wipro/Halonix Make. | 22 | No. | 1,350 | ₹29,700 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.50 MB
BOQ_1032531.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .